Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Dec 2022, 6:00 pmClosed
CE SHILLONG ZONE
HQ CE SHILLONG ZONE, SPREAD EAGLE FALLS, SHILLONG MEGHALAYA, 793011
CONSULTANCY SERVICE FOR PROVN OF TECH ACCN FOR CENTRAL STERILE SERVICE DEPARTMENT CSSD, OT, ICU, NICU, LABOUR ROOM, 20 BEDDED ACUTE MALE AND FEMALE WARD EACH AT MH SHILLONG
2022_MES_563361_1
CESZ/SHL/ OF 2022-23
Open Tender
Consultancy Services
Item Rate
180 days
SHILLONG
ALL AS PER NIT AND TENDER DOCUMENTS
2 documents required · 2 mandatory
₹500
GE SHILLONG
₹40,000
Yes
9 Mar 2023
16 Nov 2022
15 Dec 2022
16 Nov 2022
13 Dec 2022
1 Dec 2022
Amount
CONSULTANCY SERVICE FOR PROVN OF TECH ACCN FOR CENTRAL STERILE SERVICE DEPARTMENT (CSSD), OT, ICU, NICU, LABOUR ROOM, 20 BEDDED ACUTE MALE AND FEMALE WARD (EACH) AT MH SHILLONG including following 1. Site clearance and area development 2. Preparation of site plan, incl layout of Bldg and external services as per tentative site plan enclosed. 3. DPR for bldg incl internal services. a) RCC framed Structure for Tech Accn for various department and ward at MH Shillong. Line plan for G+4 bldg enclosed. Appx Plinth area – 6316.41 Sqm. b) RCC framed Structure Pump House, approx plinth area – 105.00 Sqm. c) RCC framed Structure AC plant room approx plinth area – 119.20 Sqm. d) RCC Retaining wall as per site requirement. 4. Topographical survey, contour MAP in 3m x 3m grid and leveling, approx area 10000 Sqm on total Station. 5. Sub- Soil investigation for design as per IS code IS:1892, IS:1904, IS:2911 Part -I (Section 1 -4), IS:15284 (Part-I & II), IS:1892, E-in-C’s Branch guildlines and SOP (available with HQ CESZ) and ground condition. 6. Preparation of Arch working drg based on tentative line plan provided by HQ CESZ. Prepare drg in Auto CAD (drg formats) duly signed by registered Arch. 7. Analysis of Structural design and preparation Structural drgs as per IS : 456-2000, SP : 34, SP:38, IS : 1893:2016, IS :13920-2016, IS: 875-1987, IS : 800-2007, IS: 4326-2013, SP: 16, IS : 1080-1985, IS : 1904-1986, IS : 2950 Part I 1981, IS : 6403-1997, IS : 15284 Part -I 2003 and other relevant BIS codes. The area in under Seismic Zone V. The analysis and design shall be carried out under latest version of STADD Pro.
8.The following strl details shall be adopted for design of Bldg/ Retaining wall:- a) RCC - M-25 (Design Mix) b) Reinforcement - Fe-500D (TMT Bars) c) Seismic design- Zone V d) SBC of soil - As per soil investigation e) Wind Speed-as applicable f) Temp range - As applicable g) Roof slope - As shown on roof line plan 9. For design of UG Sump a) RCC - M-30 (Design Mix) b) Reinforcement - Fe-500D (TMT Bars) c) Seismic design- Zone V d) IS Code for RCC 6670, 2009 Part I to IV and other relevant BIS Codes. e) Exposure of concrete - severe condition 10. Preparation of BOQ & Yardstick of all the bldg, UG Sump, retaining wall, Boundary wall etc, including all internal and external services. 11. Complete quantity of earth work cutting and filling required in the work to be estimated with detail including level sheets. 12. Air Conditioning: Consultancy for preparation of DPR of following items of wks. a) Recce of entire MH and study of proposed new MH bldg for provision of Central Air condition to OTs and other facilities. b) Designing of Air Conditioning System including designing of AC plant heat load calculation, design, layout and fixing arrangements of supply & return air ductings, design and layout of chilled & condensed water pipelines, capacity & location of cooling tower, make-up tank, expansion tank of AC plant etc to make the AC system 100% functional. c) The AC system should be designed considering 100% Air change for ultra-sterile zone of super-speciality OTs. d) The chilled water pump & condensed water pump should be planned in such a way that one main & one stand -by pump should be there in the system. There should be 50% standby compressor in the system. e) For variable air-conditioning load of MH, VRF system may be considered. 13. Lift :-Designing of electrically operated automatic control stretcher cum passenger lift and service lift of speed 0.36 m/s and 0.75 m/s as per Scales of Hospital Accommodation 2003, NBC-2016 & IS 14665-1:2000 and any other relevant standards. 14. Fire Fighting :-Designing of wet riser type fire fighting system as per NBC-2016, IS-3844:1989 and any other relevant standards suitable for multi-storied MH Bldg.
15. Medical Gas Pipeline System (MGPS) :- Designing of medical gas pipeline system as per NFPA 99/ISO 8573-1/ISO 14971/EN ISO 7396/HTM 2022/HTM 02 01 Standard (as per latest amendments) or any other relevant standards. 16. 3D digital modeling of MH bldg (G+4 Configuration). Note: For any specification, authorization of work services etc. required for preparation of DPR, contact HQ CE Shillong Zone. However tentative area and Scope of work enclosed.
Renaissance Arch Consultant Pvt Ltd
GEO DESIGNS AND RESEARCH PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .