Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC FLAT NO 1 GURUKRUPA APARTMENT BEHIND TELEPHONE EXCHANGE DEHUROAD PUNE | PUNE | PUNE | MAHARASHTRA | 412101 | L1 | Accepted-AOC H S Takhi accepted L1 | |
| 2 | L2₹31.8 L+₹4,331.85 (0.14%)Rejected-Finance CITY SURVEY NO 111 15 9 VIJAYA NAGAR KALEWADI PUNE 411 017 | PUNE | MAHARASHTRA | 411017 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹33.7 L+₹2.0 L (6.42%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹35.2 L+₹3.5 L (10.9%)Rejected-Finance FLAT NO 20 AMBEDKAR ROAD DEHU ROAD PUNE 412101 D 101 CESC INDEX NO D 101 HQ CESC PUNE | NA | NA | 412101 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹36.0 L+₹4.3 L (13.5%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
25 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Dehu Road, Pune
GE Dehu Road, Pune
SPL REPAIR TO GOVT MD ACCN AT SHIVAJI ENCLAVE BLOCK NO P806 OF OD TALEGAON PROVN OF FOL DUMP VOLLEY BALL COURTS AT KLP FOR CERTAIN UNIT UNDER AGE BR WEST AT GE DEHU ROAD
2023_MES_591778_1
8741
Open Tender
Civil Works
Item Rate
270 days
GE Dehu Road, Pune
Pl refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Dehu Road, Pune
₹90,000
Yes
27 Jan 2024
27 Apr 2023
27 May 2023
27 Apr 2023
25 May 2023
11 May 2023
Amount
Taking out existing water proofing treatment including cement plaster(any no of layers) on roof surfaces, cleaning the surfaces and removing the debris outside MOD land complete all as specified and as directed.
Extra over rendering for work in isolated width such as in bands, sunk pannels, cornices, skirting sides of slabs, parapet sides and top drip moulds etc and similar work not exc 15 cm width or girth complete all as specified and directed.
M/L for cleaning the plastered / concrete surfaces with wire brushes and applying water proofing treatment as under :- (a) Provide 10 mm thick plaster in CM (1:6) (b) Apply one coat of oil bituminous primer @ 0.20 kg/Sqm over concrete surface. (c) Laying APP Polimerised modfied membrane not less than 3 mm thick and weighing not less than 3.5 kg per Sqm by torch applicaton method. (d) The overlap for APP membrane shall be 75 mm on longitudinal direction and 100 mm on transverse direction (e) Finally applying a coat of solar reflective bitminous aluminium paint @ 0.15 Kg/Sqm over the membrane. (i) 'Moply FP' of M/s Texsa (I) Pvt Ltd. (ii) 'Hyperplast' pf IWL India Ltd. (iii) 'Super thermpay' manufactured by M/s Shalimar tar product (iv) 'Hydroflame' of M/s Hydrotech Ltd.
Disconnecting of existing tanks, setting aside (or lowering if required) for repairing, cleaning etc and hoisting if required. reconnecting and refixing in position (cleaning , repairing etc would be measured separately)
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe spouts for connecting inlet, outlet, over flow and washout pipes all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing of 15 mm bore of pipe complete all as specified and as directed.
Taking up or down steel tubing and connections including cleaning for refixing of 20 mm bore of pipe complete all as specified and as directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth
M & L for 15 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
M & L for 20 mm bore GI pipe medium grade with all fittings and fixtures and fixed to wall, ceiling, floor complete all as specified and as directed.
S & F in repairs ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore and fixed (minimum weight 210 gms ) complete all as specified and as directed.
S & F in repairs 15 mm dia stop valves cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or union fixed in repair for 15 mm dia GI pipe all as specified and as directed.
S & F in repairs 15 mm dia stop valves concelaed type cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or union fixed in repair for 15 mm dia GI pipe all as specified and as directed.
S&F in repairs 15 mm dia chromium bib taps plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15mm dia pipe complete all as specified and as directed.
S & F in repairs 15 mm dia Brass cromium plated shower rose of 125 mm long leg complete all as specified and as directed.
S&F in repairs grating round 100 mm size of PTMT (Minimum weight 25gms.) complete all as specified and as directed.
S& F repairs stainless steel Sinks 1 mm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar overall size 495mm x 420 mm bowl size 410 mm x 330 mm x 160 mm complete including fixing cantilever brackets and connecting union to waste pipe and coupling complete all as specified and as directed.
S & F in repairs for PVC connection pipe 15mm dia with PTMT nuts of length 450mm complete all as specified and as directed.
S&F as in repairs PVC low level flushing cistern white 10 litre capacity incl PVC inlet pipe with brass check low level full both sides alongwith PVC flush pipe 32mm dia jointed to WC and handle incl brackets all as directed.
S&F repair plate rack made of stainless steel 0.63 mm thick kitchen including fixing overall size 915mm x 915mm x 255 mm all as specified and directed.Make Nirali/Silver shine/Jindal
S&F vitreous china squatting pan ORRISA PATTERN size 580x440mm white with integral foot rests excluding flushing cistem & fush pipe fixed in repairs complete all as specified and as directed. .
Dismantling / taking down AC waste/vent pipes fixed to walls with all fittings/ accessories 100 mm dia pipes all as specified and directed by Engineer-in-Charge.
S&F, PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls, or laid in trenches bore of pipe 110 mm dia complete all as specified and directed by Engineer-in-Charge.
S&F,110 mm dia PVC (SWR) bends, any radius with access door complete all as specified and directed by Engineer-in-Charge.
S&F, 110 mm dia PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish all premises all as specified and directed.
M & L non skid coloured ceramic tiles 7 to 8 mm thick area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm , in floors, etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match. Including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete.
M&L for non-skid coloured tiles 8mm thick (square/rectangular) polished area of each tile 0.36 sqm but n exc 0.42 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm th screed bed in CM 1:6 complete all as specified and as directed.
Ditto as per item No 29 above but on skirting over 10 mm th rendering in CM 1:4 complete all as specified and as directed.
M & L Glazed ceramic tiles in vertical surface 450mm x300x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles incl backing coat 10mm thick in CM 1:4 all as direced.
Dismantling of stone slabs and tiles of any description or thickness in floors aprons laid and bedded and pointed in cement mortar complete all as specified and as directed.
M&L for Marble work green marble 18 to 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with green marble shade complete all as specified.
M&L machine cut cuddapah stone slab flooring 20-25mm thick over and including cement screed based 15 mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl cutting polishing and rubbing complete all as specified and as directed.
Demolition of cement concrete ( unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M & L for cement concrete Type C2 1:3:6 (using 40mm graded aggregates) as in plinth protection 75 mm thick finished top surface even and smooth without using extra cement complete all as specified and as directed.
M & L for 100 mm thick Cement concrete type D-2 1:4:8 (40 mm graded aggregate) as in sub base complete all as specified and as directed.
M & L for precast concrete interlocking paver block rubber moulded any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade with grey cement and pigment over 25 mm thick sand cushion complete all as specified and as directed.
Taking down chowkhats or with shutter (without taking off shutter from the frames) & removing from site exc. 1.5 Sqm but n. exc. 4 Sqm each.
–Ditto- as item No 39 above but n.exc. 1.50 sqm each
Taking down shutters of any description exc. 1 sqm and not exc. 2 sqm each
Taking down steel window / ventilator of any size
Cutting holes in brick walls exc half brick but n exc one brick, built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required -depth of embedded portion of holdfast or lugsmeasured from the face of jamb into the wall - exc. halfbrick but n exc. one brick.
S&F for pressed steel door frames with one or more rebates incl necessary fixing lugs, hinges, lock strike plates of size 125 X 60mm
S&F for pressed steel door frames with one or more rebates incl necessary fixing lugs, hinges, lock strike plates of size 105 X 60mm
M/L for PCC 1:2:4 type B1 in door frame filling all as specified and directed.
S&F factory made 35 mm thick plain framed paneled shutter (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with Commercial veneered on both faces the size of rail and style as per IS-1003 ( Pt-I) kiln seasoned and Chemically pressed of 2nd class hard wood.
S & F factory made 35 mm thick glazed & skeleton shutter of 2nd class hard wood open rebated and prepared to receive gauge (divided into squares with sash bars) edges of framing plain chamfered or rounded, fitted without & fitted beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I Sec-8 clause 8.23 (a) and fitted to chowkhats complete all as specified.
S&F aluminium powder coated window sliding type (3 track) with frame size100x35x1.2mm and shutter 39.40x17.70x1.2mm with two glass shutter & one mesh shutter incl necessary jointing cleats cleats, glazing clips, rubber packing,and locking arrangement powder coated aluminium snap beading screws with 4mm plain float glass & 0.56 mm dia SS wire mesh, fittings etc complete all as specified.
S&F aluminum powder coated ventelator shutter with frame with or without sash bars of aluminum section weighing 0.55 Kg per Sqm including necessary joining clits , glazing clips, rubber packing, alu. Snap beading , screws, aluminum fittings, suitable handles complete .
S&F in repairs curtain rod 25 mm dia powder coated fancy type complete with side knobs all as specified and directed.
S&F in repairs brackets fancy type powder coated for 25 mm dia curtain rod complete all as directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing
S&F factory made PVC solid panel door shutter 30mm thick (style) connecting of frame made out of MS tube for top and bottom rail. MS frame shall be coverd withheat moulded plain coour PVC 'C' channel having a PVC sheet strips of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail of either side and as gap insert for toprail and bottom rail panellinn of plain colour PVC to be fitted in the ms frame welded/ sealed in the stiles and rail with suitable PVC sheet and loading and jointed together with solvent cement, supplying and fixing in the frame at site all as directed by Engineer -in -charge.
S & F galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.00mm complete all as specified and directed.
S & F 150 mm size extruded aluminium alloy handles,fabricated type anodised.
S & F aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 150mm
S & F aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 100mm
S& F 100 mm Butt hinges, stainless steel, bright polished and fixed, type B-11 all as specified and directed
S & F aluminium alloy , anodised , sliding door bolt with hasp , staple (bolt type) & fixing clips of sheet, cast or extruded section & fixing bolts & sliding bolts of extruded section or cast aluminium alloy & fixed - length of bolt 250 mm
S&F in repairs floor door stopper with overall length of cover plate is 150 mm, of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor.
Dismantling of boarding, any description and fixed in any position with nails complete all as specified and directed.
Dismantling timber fillets under 40 Sq.cm in section unframed work , in any position complete all as specified and directed.
S & F in repairs pre-laminated particle board 25mm thick exterior grade prelaminated one side with deocrative choice lamination & other side balancing white lamination, fixed with screws to timber frame work incl 6mm thick teak wood lipping patti complete.
S & F 30 mm thick Second class hard-wood Boarding fixed with nails in any situation complete all as specified and directed.
S & F of 2nd class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails sectional area exc 13 & not exc 25 sqcm complete all as specified and directed.
S&F in repairs continuous Piano type hinges mild steel bright finish or electrogalvanised (width of flap 40 mm when open) complete.
S & F of 100 mm size brass hasp and staple safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
M&L for rendering cement plaster 10 mm thick in CM 1:6 on fair faces of brick walls finished even and smooth w/o using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick plaster on new concrete surfaces in CM 1:6 with sagol finish.
M & L for Rendering 05 mm thick cement plaster on concrete surface of ceiling in cement mortor 1:3 shall be even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering cement plaster 15 mm thick in CM 1:4 on fair faces of brick work or conrete wall surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M & L for Preparation of newly plastered surfaces of wall and appling two coats of oil bound distemper on walls over a coat of primer on plastered surfaces complete including 3mm thick wall care putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coat of white washing complete all as specified and as directed.
M & L for Preparation of newly plastered surfaces of wall and appling two coats of cement base paint on walls over a coat of primer on plastered surfaces complete all as specified and as directed.
M&L for preparation and applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden surfaces n exc 10cm width or girth complete all as specified
M&L for complete removal of existing treatment from old decorated surfaces of wall and applying two coats of distemper oil emulsion over and including a coat of primer plastered complete all as specified and directed by Engineer - in - Charge.
Complete removal of existing treatment from old decorated surfaces of walls and applying two coats of cement base paint over and including a coat of primer complete all as specified and directed by Engineer - in - Charge.
M&L applying one coat of white wash on old decorated surfaces of ceiling including preparation of surfaces complete all as specified & directed by Engineer-in-Charge.
M&L preparation of old painted wooden surfaces of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified & directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in Sunken portion exe 15 cm thickness (below or aboveground level) complete all as specified and directed.
M & L cement conrete 1:7:12 type F2 (uisng 40mm graded aggregate) as in sunken filling complete all as specified and directed.
Providing and carrying out water proofing treatment to toilet ,sunken slabs ,wet areas etc,after proper surface prepration ,carry out cementitious ingection grouting at leakage point using Cebex 100 plasticised expanding grouting admixture ,application of polymer modified at slab wall junction using Nitoband SBR latex screed modifier cum bonding agent and application ot two coats of brushbond RFX two part acrylic polymer modified cementitious elastomeric waterproof and protective coating etc,complete including 15 mm thick cement plaster in CM 1:4 all tools and plants as per manufacturer's specification paint complete all as specified and directed.
Surface dressing n exc 15 cm deep and getting out in hard dense soil complete all as specified and as directed by Engineer -in- Charge
Removing excavated material (SOIL) exc. 250 m but n exc. 500 m and depositing where directed
Supply and filling of approved earth / moorum filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and directed
Rolling and consolidating formation surfaces in cutting by 8 to 12 Tonne power Roller complete all as specified & as directed
M & L 100 mm thick PCC 1:2:4 mix, type B-2 (40 mm graded stone aggregate) complete all as specified and as directed by Engineer-in-Charge
Supply and fixing 2 volleyball poles (Make Cosco of Equivalent) with Net standard size and height with cement concrete as per direction of Engineer-in-Charge
Supply, installation and finishing of Synthetic sports flooring system consisting of 5 layer system with Acrylic latex to subfloor followed by primer layer to improve bonding of acrylic paint with subfloor and smoothing subfloor following by Dual layers of 100% acrylic base colour coat followed by Top colour coat to protect flooring against UV rays final overline marking with Acrylic paint complete all as specified and as directed by Engineer-in-Charge
Surface dressing n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts etc. not exc. 10 Sqm on plan, not.exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
M & L Cement Concrete Type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass concrete, etc
M & L for hard core of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in hard/dense soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M&L Treating the AntiTermite Treatment for bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L Treating the AntiTermite Treatment for top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L Treating the AntiTermite Treatment for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3 , using 20 mm graded stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3, using 20 mm graded stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3, using 20 mm graded stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for providing reinforced cement concrete 1:1.5:3, using 20 mm graded stone aggregate, as in chajjas and the like complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Ditto as per item No 13 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders complete all as specified and directed.
M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed.
M & L for use and waste of form work to chullah hoods, chajjas, troughs and similar items including edges in rough finished surface of concrete complete all as specified and directed.
M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed.
M&L Brickwork using old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
Supply only integral water proofing compound.
M & L for 75mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in sub basecomplete all as specified and directed.
M&L for two coats of oil bound distemper paint on new plastered surfaces of walls including 3mm thick wall putty on plastered wall surface incl prepration of surfaces and priming with alkali resistant priming paint complete all as specified & directed by Engineer-in-Charge.
M&L two coats of white wash to new plastered surfaces on ceiling including preparation of surfaces complete all as specified & directed by Engineer-in-Charge.
S&F 125 mm MS, Butt hinges,medium weight cold rooled fixed with screw or welding complete.
S & F of 250 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt or cast aluminium alloy complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not exc 10 cm width or girth & applying 2 coats of synthetic enamel paint over a coat of red oxide primer. complete all as specified and directed.
M & L Cement Concrete Type B2 1:2:4 (40 mm graded aggregate) in foundations, filling and mass concrete,toewall etc complete all as specified
M&L for Earth Spreading and levelling in layers n exc. 25 cm thick well ramming including watering as required
M&L for 150 mm thick Cement concrete flooring, hardstanding type B-2,1:2:4 (40mm graded aggregate) complete all as specified and directed
M&L applying two coats of cement base paint with silicone additives on external surfaces of wall including primer and preparation of surfaces as per manufacturers instruction all as specified and directed by Engineer-in-charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil.
Finishing surface of concrete roads, pavements etc by brooming complete all as specified and directed.
M & L for forming Forming Construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A'
M & L for forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound grade 'A' complete all as specified and directed.
E/M portion
Taking down carefully copper/aluminium point wiring (light, fan, socket or ower) complete,(fittings such as switches, ceiling roses,pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc.
Taking down unserviceable submain wiring alongwith batten/PVC/steel conduits etc and making good disturbed surfaces of walls/ floors to match the existing surfaces all as specified
Taking down unserviceable main switches ,DBs alongwith teak wood boards etc and making good disturbed surfaces of walls/ floors to match the existing surfaces all as specified
Taking down old point wiring & M&L for point wiring with 1.5 sqmm multistranded copper conductor cable of PVC insulated and unsheathed type alongwith 1.5sqmm PVC insulated unsheathed single stranded copper conductor cable for continous earthing in & incl casing / caping or PVC Pipes & accessories having ISI marked surface type to be fixed with proper screws/(MS steel strips if required) including hard PVC boards of suitable sizes & making arrangement for fixing switches, sockets, switch socket combination, fan, regulator setc for Note:- Screws used for fixing PVC boards, casing & caping ceilling rose square blocks etc should be nickel cadmium screws:-
a) One light point controlled by one one way switch
b) One light point controlled by one two way switch
c) One Fan/Exhaust fan point controlled by one switch
d) One switch socket 5 pin 5 Amps flush type on same board.
e) One switch socket 5 pin 5 Amps flush type on Independent board.
f) One bell/ buzzer point controlled by one push button on the same board with other switches or independent
- do - all as per item No 04 above but with 2.5 sqmm (36/0.3mm) FR cable for one socket 5 pin 15Amps flush type on independent board with including earthwire complete.
S & F Switch piano flush type single pole one way 230V 6Amps
S & F Switch piano flush type single pole two way 230V 6Amps
S & F Socket outlet 2 in 1 , 3 pin 5 Amps flush type 230V S.P. multipurpose type
S & F Switch socket combination flush type multi purpose 5A/16A, 5 in 1controlled by one switch 230V.
S & F ceiling rose surface PVC 50 mm dia three terminals including PVC mounting block, white/lvoury /Urea finish.
M&L in repair for stepped type electronic fan regulator flush type on the existin phenolic laminated sheet etc as required for ceiling fan 230 volt AC supply, 50HZ 1200/1400 mm sweep
S & F Bell push, flush type, 5 amp, 230V
S & F Bell ding dong type 230V
M&L submain wiring with 2 single core PVC insulated multistranded flexible copper conductor 1100Volts grade (FRLS) cables 4.sqmm and 1 run 2.5 Sq mm PVC insulated multistrand cu conductor cable (FRLS) of green colour for continious earthing drawn through PVC surface/concealed PVC conduit of suitable size and with all accessories all as directed and specified by Engr-In-charge.( Note: Two runs of 4 sqmm, one run of 2.5 sqmm copper conductor and one run of surface/concealed PVC conduit of suitable size and with all necessary fixing accessories and making good disturbed surface area shall be measured as one length.)
M & L for earthing complete with galvanised steel earth plate electrode 60cm ×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel,earth wire protected by GI pipe 15 mm dia 'light grade' including charcoal dust, common salt, excavation & earth work, PCC Pit with 1:3:6 type C-1, 40 mm thick RCC cover in 1:2:4 type B-1 reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handles 12 mm dia, PGI funnel & GI watering pipe 'light grade' 20 mm bore all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
M & L MCB DB SPN sheet metal double door enclosure mounted on teak wood board of suitable size for mounting MCB 230 Volts with 200 Amps rated bus bar 8 way
S & F MCB SPN 5-40 amps, 240Volts 10KA
S & F MCB SP 5-40 amps, 240Volts 10KA
S&F LED lights fitting 1x20 Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete
S&F LED light fitting mirror type with high out put diffuser 2 feet 10 W 220 V AC decorative type with driver holder & LED lamp including connecting up with 3 core flexible copper conductor cable of suitable sixes complete.
Taking down ceiling fan 1200/1400 mm sweep / exhaust fans including disconnection of electric connection and removing the blades in safe for reinstalling
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fix in repair LT indoor panel board made up of 2 mm thick MS Sheet duly powder coated with closing and locking arrangement as per suitable size fixing on wall with wooden plank of 18 mm thick inside panel including taking down and refixing existing electronic energy meter with replacemnt of following new items :- (a) MCB DB TPN 4 way double door -01 No (b) Isolator 4 pole 100A-01 No (incomming) (c) Isolator DP 40A- 05 No (out going)
S & F LED light fitting for building security/street light fitting 1x 20 w, 230 V,complete with all accessories internally pre-wired and including connecting up with 2.5 sqmm twin core flexible copper cable for connection from ceiling rose to fitting including LED light and GI bracket medium grade of 1.2 meter shaped to 120 degree for fixing of fitting on wall with clamps and Make : Bajaj / philips / Crompton
S & F exhaust fan AC single phase 230 V,300 mm sweep, heavy duty with louvers, metal body, blades, Insulation Class A including capacitor complete all as specified and directed by Engineer-in-charge( including making hole on exixting wall and making good surface of wall with necessary PCC Work and plaster etc.) . Make :-Model : Ventil Air-DB 300 mm of Havells and equavalant of GEC/Bajaj/ CG/ Khaitan/ Usha
Dismantling /disconnecting LT cables of any size with accessories. Old unserviceable of any type broken or damaged cables fitting on poles / laid in trenches and keeping aside for further disposal.
Supply & Laying cable XLPE insulated screened PVC bedded ,galvanized steel strip or wire armoured ,electric power cable heavy duty 1100 volts grade with strandad aluminum conducter of 25 sq. mm X 4 core :- Make :- Havells/ Polycab/ Gloster
M/S RENUKA CONSTRUCTIONS
DR J S CHADHA AND SONS
Santhi Enterprises
Dinesh Constructions
Ganesh Sonajirao Garje
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .