Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC D NO LIG 98 RAJEEV NAGAR KURMANNAPALEM VISAKHAPATNAM 530 048 | VISAKHAPATANAM | ANDHRA PRADESH | 530048 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹25.2 L+₹2.4 L (10.7%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L2 | Rejected-Finance Being not L1 bidder | |
| 3 | L3₹26.4 L+₹3.6 L (16.0%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L3 | Rejected-Finance Being not L1 bidder | |
| 4 | L4₹29.7 L+₹6.9 L (30.3%)Rejected-Finance | L4 | Rejected-Finance Being not L1 bidder | |
| 5 | L5₹31.9 L+₹9.2 L (40.2%)Rejected-Finance | L5 | Rejected-Finance Being not L1 bidder |
| Sl No | Description | Qty | Unit | GVR ENGINEERING WORKS L6 | RATNA ENTERPRISES L8 | MSN ENGINEERING WORKS L2 | SRIESWARI ENTERPRISES L3 | SATYAMEGHA ENGINEERS L5 | ALPHA ENGINEERING CONSTRUCTIONS L7 | MONITOR ENGINEERING WORKS L1 | SUPREET CONSTRUCTIONS L10 | SRI VINAYAKA INFRA L4 | ANAND ENTERPRISES AND ENGINEERS L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed. | 420.35 | Cum | 220 ₹92,477 | 180 ₹75,663 | 189 ₹79,446.15 | 210 ₹88,273.5 | 200 ₹84,070 | 190 ₹79,866.5 | 193 ₹81,127.55 | 302 ₹1,26,945.7 | 170 ₹71,459.5 Lowest | 170 ₹71,459.5 Lowest |
| 2.00 | Returning, filling in trenching with soil and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed. | 228.14 | Cum | 80 ₹18,251.2 | 120 ₹27,376.8 | 80 ₹18,251.2 | 100 ₹22,814 | 60 ₹13,688.4 Lowest | 100 ₹22,814 | 123 ₹28,061.22 | 75 ₹17,110.5 | 100 ₹22,814 | 110 ₹25,095.4 |
| 3.00 | Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. | 192.22 | Cum | 70 ₹13,455.4 Lowest | 120 ₹23,066.4 | 100 ₹19,222 | 100 ₹19,222 | 150 ₹28,833 | 120 ₹23,066.4 | 153 ₹29,409.66 | 100 ₹19,222 | 170 ₹32,677.4 | 100 ₹19,222 |
| 4.00 | M&L sand cushioning with clean and dry stone crushed stone dust in trenches for protection of UG cable and including punning down complete all as specified and directed.
Note:- Punned thickness of stone dust coushioning shall only measured and paid. | 137.57 | Cum | 625 ₹85,981.25 | 700 ₹96,299 | 850 ₹1,16,934.5 | 600 ₹82,542 Lowest | 1,000 ₹1,37,570 | 700 ₹96,299 | 1,053 ₹1,44,861.21 | 1,050 ₹1,44,448.5 | 800 ₹1,10,056 | 650 ₹89,420.5 |
| 5.00 | Supply & laying sub class 'B', class designation 75 bricks of old size, laid over sand cushioning along alignment of cable as protection to cable in trenches including taking out old bricks complete all as specified and directed.
Note : Sand cushioning will measured and paid seperately. | 14,768 | Each | 6 ₹88,608 | 7 ₹1,03,376 | 7 ₹1,03,376 | 7 ₹1,03,376 | 6 ₹88,608 | 5 ₹73,840 Lowest | 5 ₹73,840 Lowest | 5 ₹73,840 Lowest | 9 ₹1,32,912 | 6 ₹88,608 |
| 6.00 | S&F for GI pipe light grade 40 mm bore galvanised steel tubing, light grade with necessary fittings, laid under road crossing, for cable protection including taking down existing un-serviceable GI pipe of any description complete all as specified and directed. | 50 | RM | 350 ₹17,500 | 350 ₹17,500 | 400 ₹20,000 | 400 ₹20,000 | 400 ₹20,000 | 300 ₹15,000 | 253 ₹12,650 | 635 ₹31,750 | 220 ₹11,000 Lowest | 310 ₹15,500 |
| 7.00 | All as per Sl. Item No. 6.00 here in before but of size 50 mm | 24 | RM | 425 ₹10,200 | 500 ₹12,000 | 600 ₹14,400 | 550 ₹13,200 | 500 ₹12,000 | 400 ₹9,600 | 293 ₹7,032 | 770 ₹18,480 | 250 ₹6,000 Lowest | 540 ₹12,960 |
| 8.00 | All as per Sl. Item No. 6.00 here in before but of size 80 mm | 24 | RM | 600 ₹14,400 | 620 ₹14,880 | 800 ₹19,200 | 650 ₹15,600 | 750 ₹18,000 | 800 ₹19,200 | 363 ₹8,712 Lowest | 1,000 ₹24,000 | 430 ₹10,320 | 710 ₹17,040 |
| 9.00 | M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC 1:3:6 or bituminous mix as per existing & matching with the surroundings complete all as specified and directed.
Note : Rate quoted shall deemed to inclusive of road cutting of any description, earth work excavation and making good on top with 100 thick PCC complete. | 11 | RM | 400 ₹4,400 | 1,500 ₹16,500 | 600 ₹6,600 | 150 ₹1,650 Lowest | 1,000 ₹11,000 | 300 ₹3,300 | 2,563 ₹28,193 | 1,000 ₹11,000 | 1,100 ₹12,100 | 1,300 ₹14,300 |
| 10.00 | Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 25 Sqmm x 4 Core, laid in trenches / duct / on pole including taking down existing un-serviceable cable complete all as specified and directed. | 400 | RM | 190 ₹76,000 | 235 ₹94,000 | 150 ₹60,000 Lowest | 200 ₹80,000 | 230 ₹92,000 | 220 ₹88,000 | 193 ₹77,200 | 283 ₹1,13,200 | 150 ₹60,000 Lowest | 190 ₹76,000 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
27 Oct 2025, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/ MAINT OF LT FEEDER PILLAR BOXES, LT UG CABLES AND CONNECTED WKS OF LT DISTR SYSTEM INCL ATTENDING FUSE OFF CALL AT INS DEGA UNDER AGE E/M NO-II OF GE (U-I) VISAKHAPATNAM
2025_MES_733932_1
8781/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Utility-I
₹84,000
Yes
12 Dec 2025
6 Oct 2025
29 Oct 2025
6 Oct 2025
27 Oct 2025
21 Oct 2025
Amount
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
Returning, filling in trenching with soil and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry stone crushed stone dust in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness of stone dust coushioning shall only measured and paid.
Supply & laying sub class 'B', class designation 75 bricks of old size, laid over sand cushioning along alignment of cable as protection to cable in trenches including taking out old bricks complete all as specified and directed. Note : Sand cushioning will measured and paid seperately.
S&F for GI pipe light grade 40 mm bore galvanised steel tubing, light grade with necessary fittings, laid under road crossing, for cable protection including taking down existing un-serviceable GI pipe of any description complete all as specified and directed.
All as per Sl. Item No. 6.00 here in before but of size 50 mm
All as per Sl. Item No. 6.00 here in before but of size 80 mm
M&L for cutting the tarmac / hard standings in road and excavating trenches across the road in size not exceeding 0.45 m wide and 0.6 m depth for laying cable including refilling earth & making good top surface of the disturbed portion with 100mm thick PCC 1:3:6 or bituminous mix as per existing & matching with the surroundings complete all as specified and directed. Note : Rate quoted shall deemed to inclusive of road cutting of any description, earth work excavation and making good on top with 100 thick PCC complete.
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 25 Sqmm x 4 Core, laid in trenches / duct / on pole including taking down existing un-serviceable cable complete all as specified and directed.
All as per Sl. Item No. 10.00 here in before but for cable of size 35 sqmm x 3.5 Core
All as per Sl. Item No. 10.00 here in before but for cable of size 50 sqmm x 3.5 Core
All as per Sl. Item No. 10.00 here in before but for cable of size 70 sqmm x 3.5 Core
All as per Sl. Item No. 10.00 here in before but for cable of size 95 sqmm x 3.5 Core
All as per Sl. Item No. 10.00 here in before but for cable of size 120 sqmm x 3.5 Core
All as per Sl. Item No. 10.00 here in before but for cable of size 150 sqmm x 3.5 Core
All as per Sl. Item No. 10.00 here in before but for cable of size 185 sqmm x 3.5 Core
All as per Sl. Item No. 10.00 here in before but for cable of size 240 sqmm x 3.5 Core
All as per Sl. Item No. 10.00 here in before but for cable of size 300 sqmm x 3.5 Core
All as per Sl. Item No. 10.00 here in before but for cable of size 400 sqmm x 3.5 Core
M&L for removing electrical connections of 3 / 4 pole Air circuit breaker of capacity 800 to 1600 Amps, 415 V, 50 HZ of any make, strip opening of the ACB, inspecting the parts for serviceability / overhauling complete and carrying out following repairs / maintenance :- a) Cleaning insulation parts including bushings with CTC solution. b) Checking alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual. c) Checking the bolts, nuts, washers, cotter pins and all terminal connections are in place and tight, replacing worn-out parts. d) Checking arc chutes for damage and replacing damaged parts. e) Cleaning and lubricating the operating mechanism with light machine oil (SAE-20 or 30) for pins and bearings and with a non-hardening grease for wearing surfaces, adjusting breaker operating mechanism all as per manufacturer's instructional manual, replacing the same if there is excessive wear and tear. f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. g) Replacing worn or burned contacts, Checking control device free for operation. h) Checking after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional. Note : (i) The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts / bolts / washers / pins etc. (ii) Major spares like contacts, shunt trip coil, relays, CTs etc if replaced, shall be measured & paid separately.
S & F auxilary contact block of make as per OEM & suitable for air circuit breakers of capacity 800 to 1600 Amps including taking down existing un-serviceable auxilary contact complete all as specified and directed.
S & F motor of make as per OEM & suitable for air circuit breakers of capacity 800 to 1600 Amps including taking down existing un-serviceable motor complete all as specified and directed.
S & F Trip alarm contact of make as per OEM & suitable for air circuit breakers of capacity 800 to 1600 Amps including taking down existing un-serviceable trip alarm contact complete all as specified and directed.
S&F Under Voltage releaseType MV, 415 V of make as per OEM and suitable for ACB of any capacity including taking down existing un-serviceable under voltage release all as specified and directed.
S & F shunt release (110 / 220 V DC or 240 / 415 V AC) of make as per OEM & suitable for ACB of 800 to 1600 Amps capacity cincluding taking down existing un-serviceable shunt release complete all as specified and directed.
S&F Insulation barrier of make as per OEM and suitable for ACB of any capacity including taking down existing un-serviceable insulation barrier complete all as specified and directed.
S&F in repairs Earth fault release Type EF 2 (30%, 40%, 50% In) of make as per OEM and suitable for ACB of any capacity including taking down existing un-serviceable earth fault release complete all as specified and directed.
S&F in repairs racking interlock of make as per OEM and suitable for ACB of any capacity including taking down existing un-serviceable racking interlock complete all as specified and directed.
S&F MCCB 3 pole 400 Amps, breaking capacity 36 kA, Ics = 100% Icu, thermal megnatic release type with adjustable overload setting (0.8-1.0 ln), adjustable short circuit setting (6-10 lr) including necessary modification in the panel & taking down existing un-serviceable MCCB complete all as specified and as directed.
All as per Sl Item No. 30.00 above but 3 pole 250 Amps breaking capacity 36 KA
All as per Sl Item No. 30.00 above but 3 pole 200 Amps breaking capacity 25 KA
All as per Sl Item No. 30.00 above but 3 pole 160 Amps breaking capacity 25 KA
All as per Sl Item No. 30.00 above but 3 pole 125 Amps breaking capacity 16 KA
All as per Sl Item No. 30.00 above but 3 pole 100 Amps breaking capacity 16 KA
All as per Sl Item No. 30.00 above but 4 pole 200 Amps breaking capacity 25 KA
All as per Sl Item No. 30.00 above but 4 pole 160 Amps breaking capacity 36 KA
S&F MCCB 4 pole 400 Amps, breaking capacity 36 kA, Ics = 100% Icu, microprocessor release type with adjustable overload setting (0.4-1.0 ln), adjustable short circuit setting (1.5-10 lr) including necessary modification in the panel & taking down existing un-serviceable MCCB complete all as specified and as directed.
All as per Sl Item No. 38.00 above but 4 pole 250 Amps breaking capacity 36 KA
All as per Sl Item No. 38.00 above but 4 pole 160 Amps breaking capacity 25 KA
S&F MCB SPN 40 to 100 Amp, 10 kA, 415V 'C' curve including taking down un-serviceable MCB complete all as specified and as directed.
Detecting LT UG cable faults located in any stretch / depth with sophisticated cable fault locator consisting of microprocessor based pre-locator system, HV surge generator, fault pin point surge wave receiver, cable identification instrument, cable tracer for exact location of under ground cable routes complete all as directed. Note:- The rate quoted shall deemed to inclusive of arrangement of serviceable necessary fault locator equipment to find cable fault and including its transportation charges, loading & unloading, service engineer charges Etc., complete.
M&L straight through cable joint kit, heat shrinkable type complete with jointing materials and accessories, suitable for 1.1 KV, 3.5 core XLPE aluminium conductor cable of size 25 to 50 Sqmm including taking down existing un-serviceable joint kit complete all as specified and directed.
All as per Sl Item No. 43.00 here in before but suitable for cable of size 3.5 core 95 to 120 Sqmm
All as per Sl Item No. 43.00 here in before but suitable for cable of size 3.5 core 150 to 185 Sqmm
All as per Sl Item No. 43.00 here in before but suitable for cable of size 3.5 core 240 to 300 Sqmm
M&L with replacement of canopy, door, body angle iron support etc. of existing LT feeder pillar box, body made out of 3.15 mm thick CRCA sheet and support of angle sections as per existing, duly power coated with one coat of synthetic enamel paint over a coat of primer with removable door hinges, neoprone gasket and locking arrangement, including welding work for fixing the door complete all as directed. Note:- Unit rate quoted shall deemed to include hinges, locking arrangement, neoprone gasket etc reqd for LT feeder pillar box.
M&L for preparation of external surfaces of LT panel of size from 1000mmx1000mmx400mm to 1200mmx1200mmx500mm by scraping complete removal of old rusted paint with steel brush, brooming, rubbing and cleaning including spray painting with two coat of synthetic enamel paint including one coat of red oxide primer on external surface and marking feeders complete all as specified and as directed by Engineer-in-Charge.
S&F in repair aluminium lugs to cable end suitable for cable of size of 10 to 50 sqmm complete all as specefied and directed.
All as per Sl item No. 49.00 here in before but suitable for cable of size of 70 to 120 sqmm
All as per Sl item No. 49.00 here in before but suitable for cable of size of 150 to 240 sqmm
All as per Sl item No. 49.00 here in before but suitable for cable of size of 300 to 400 sqmm
M&L earthing complete with galvanised steel earth plate electrode of size 60 cm x 60 cmx 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to earth lead of galvanised iron strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point including dismantling existing un-serviceable earthing complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:2:4 type B1 chamber, RCC 1:1.5:3, type A1 cover slab, 50 mm thick reinforced with 8 mm dia TMT bar @ 140 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, Main earthing lead from earth electrode to test point upto 7.5 m length, 20 mm bore medium grade GI watering pipe, 40 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
All as per Sl item No. 53.00 here in before but using Copper plate 60 cm x 60 cm x 3.15 cm thick electrode and 20 x 3 mm copper strip as earthing lead complete all as specified and ditected.
S&F earth continuity conductor or main earthing lead using 32 x 6 mm Copper strip, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation with saddles and fixing screws etc. for roof conductors and down conductors above ground etc. as required complete all as specified and directed.
M&L for Maintenance and attending complaints / breakdowns at INS Dega and Dega Vihar area comprising of LT panels, over head lines / underground LT cables up to main distribution boards at buildings including day to day maintenance of LT panels / Perimeter lights for smooth & trouble free LT power supply including rectification of minor defects to electrical controls gear / accessories as directed by Engr-In -charge. Note : Unit rate quoted shall deemed to be inclusive of the following:- (a) Attending minor repairs / breakdowns without involving any new (major) materials. (b) Rate quoted shall deemed to include cost to provide tools for attending break down and minor materials like lugs, PVC tapes, including issue / maintaining Job Cards and Complaint registers etc. (c) Major repairs / Break downs involving S&F of materials such as cables, Joints, MCCBs etc are outside the scope of this item and shall be measured and paid separately. (d) Contractor should ensure to carry out the work through qualified Technician / Electrician and assisted by the helper. Necessary tools & plants and transportation charges are deemed to be included in the unit rate quoted. (e) On completion of the task /attending break down, necessary Job card duly signed by the stake holder shall be submitted to Engr-in-Charge.
S&F multifunction meter, digital type (displaying A, V, PF, Hz, KVA, KW, KVAR, KWh, Karsh etc.) Class 1/0.5 with RS485 port for communication in Modbus protocol, accuracy class-1, e-navigator, including taking down old un-serviceable multifunction meter complete all as specified and as directed.
M&L aluminium busbar of suitable size including taking down existing un-serviceable busbar complete all as specified and as directed
M&L copper busbar of suitable size including taking down existing un-serviceable busbar complete all as specified and as directed
Clearing away all bushes, small plants, grass, vegetation, saplings, shrubs, brushwood, undergrowth, roots upto root level including surface dressing n.exc 15 cm deep around and surroundings areas of E/M installations (i.e.Two Pole / Four structures, LT Panels, outdoor-substation yards, pump house & Misc E/M installations etc) and removing rubbish / debris upto a distance of not less than 50 metres outside the periphery of the area under clearance complete all as directed.
M & L for excavating existing cable of size 70 to 300 Sqmm, 3.5/4 core & taking out from its loop of length 3 to 5m, cleaning, cutting of old termination at end and reconnecting the same along with termination at ends with new aluminium lugs of suitable size and refilling of cable trench with existing sand and bricks complete all as directed. Note: The rate quoted shall deemed to inclusive of necessary earth work, excavation, sand coushioning and Bricks for cable protection.
MSN ENGINEERING WORKS (BID ID -3459671)
SRIESWARI ENTERPRISES (BID ID -3459797)
SRI VINAYAKA INFRA (BID ID -3460649)
SATYAMEGHA ENGINEERS (BID ID -3460085)
GVR ENGINEERING WORKS (BID ID -3458902)
ALPHA ENGINEERING CONSTRUCTIONS (BID ID -3460191)
RATNA ENTERPRISES (BID ID -3459144)
ANAND ENTERPRISES AND ENGINEERS (BID ID -3460792)
SUPREET CONSTRUCTIONS (BID ID -3460406)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
8781Tender.pdf
Tender Documents • 0.84 MB
BOQ_821789.xls
BOQ • 1.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .