The Chief Engineer, Sports Kerala Foundation
Jimmy George Indoor Stadium, Vellayambalam, Thiruvananthapuram
Chalakkudy Indoor Stadium-Balance Works-Maple Wood Flooring -Retender
2023_SKF_552039_5
192/SKF/CE/2022-23
Open Tender
Civil Works - Others
Item Rate
150 days
Trissur
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,950
Yes
₹50,000
Yes
19 Jun 2023
8 Jun 2023
19 Jun 2023
8 Jun 2023
17 Jun 2023
8 Jun 2023
Amount
Maple wood Flooring (CPWD)
od281138/2022_2023 : Supply and Installation of imported maple wood of thickness 21mm with resilient SPF<br>pine wood sleepers 70mmX45mm treated with anti termite solution fixed with 19 mm thick EPDM rubber<br>Pads stapled through two wings at 350mmx350mm over the vapour barrier at 350mm in 1 direction. The rate<br>is inclusive of game line marking and polishing of floor including machine sanded with drum sander - three<br>times – i.e. coarse, medium & fine grade sandpaper. Grinding and sanding using belt sander with dust<br>containment system using 36 & 60 Grit initially and then using 80 & 120 Grit followed by filling of gaps with<br>fillers along with 120 grit sand powders to fill the gaps. Apply two component of water based<br>polyurethane lacquer for sportive wooden floor coat of DIN certified. The sides of court shall be covered by<br>the wooden reaper with an expansion of 12-15 mm between wooden floor & tiled area. The work has to be<br>executed based on detailed specification, methodology, drawings etc as per the direction of Engineer in<br>charge. Sample of wooden floor shall be placed before the technical sanction authority for approval.
2.34.1 : Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos / Lindane emulsifiable concentrate of 20%
2.35.2.1 : Diluting and injecting chemical emulsion for POST -CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion):Along the external wall below concrete or masonry apron using chemical emulsion @2.25 litres per linear metre including drilling and plugging holes etc:With Chlorpyriphosl Lindane E.C.20% with 1% concentration
Joinery & Painting works (CPWD)
15.57 : Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
od279836/2022_2023 : Providing and fixing anodised aluminium louvers (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design or pattern, with approved standard section and fixed to the existing window frame with CP brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised alumnium standard section around the opening, all complete as per requirement and direction of engineer- in-charge. (only weight of grill to be measured for payment).
13.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.111.1 : Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
Electrification work
od320959/2022_2023 : Supply and installation of 125A, 4 pole On-Load Change Over Switches with SS Enclosure and others accessories as required.
90.12.7.45 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 70 sq mm
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.15.4.3 : Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.15.4.7 : Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.12.7.1 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
90.6.5.5 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 2.50 sq mm
90.12.7.38 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 4 sq mm with factory made clamp
od320997/2022_2023 : Supply and installation of pre-wired 20W LED batten fitting complete with all accessories and tube etc directly on ceiling/wall, including connection with 1.5sqmm FRLS PVC insulated,copper conductor single core cable and earthing<br>etc as required.Make: Phillips, Crompton greaves, Bajaj, Lucker or Approved by<br>engineering in charge
od323571/2022_2023 : Supply and fixing of syntex box (150mm x 150 mmx100mm) including connector ,MCB rails and neutral links for giving connection with accessories complete as required
od320998/2022_2023 : Engaging Electrician as per the direction of Engineer in Charge.
Fire fighting
od320236/2022_2023 : Supply, installation, testing and commissioning of gun metal fire hydrant valve single head oblique type with 63mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80mm pipe flange,valve conforming to IS:5290 complete with blank cap,chain, GI nuts, bolts, gasket etc as per technical specification.
od320269/2022_2023 : Supply of Controlled Percolated Hose conforming to IS: 636, 63mm dia, 15 Mtrs length with Aluminium 63 mm pair of male and female couplings With ISI Mark etc
od320270/2022_2023 : Supply of Aluminium Branch Pipe, 63mm female instantaneous inlet, male threaded outlet, With ISI Mark complete with hexagonal base nozzle.
od320811/2022_2023 : Supply and installation of 12v 180Ah battery
od320812/2022_2023 : Supply of Sprinkler, 68 degree Celsius, pendent, normal response, standard coverage, chrome finish for spare.
od320813/2022_2023 : Supply of Addressable heat detector for spare.
od320814/2022_2023 : Supply of Addressable manual pull station type for spare.
od320815/2022_2023 : Supply and installation of 12v 42 Ah Battery
od320816/2022_2023 : Refilling of existing Fire extinguishers
od320817/2022_2023 : Supply and installation of charger for diesel engine pump controller, 12 Volts 10 Amps.
od320843/2022_2023 : Supply and refilling of coolant for diesel engine driven pump
od320845/2022_2023 : Supply and refilling of diesel for diesel engine driven pump
od321274/2022_2023 : Replacement of ammeter in main pump control panel and diesel engine controller.
od321275/2022_2023 : Charges for removal and re-installation of Alarm check valve upside down for proper working including piping works.
Bidder Name
FREEWILL INFRASTRUCTURE PVT LTD
stage.html
html • 0.02 MB
finance_857424.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .