| 1 | L1₹25.3 LAccepted-AOC 117 BHAISAHIYA TOLA GANESHGANJ MIRZAPUR UTTAR PRADESH 231001 | MIRZAPUR | MIRZAPUR | UTTAR PRADESH | 231001 | L1 | Accepted-AOC Acceptance of Contract | |
| 2 | L2₹27.4 L+₹2.1 L (8.34%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC Ok | |
| 3 | L3₹28.2 L+₹2.9 L (11.5%)Rejected-AOC 00 KAMALWAGANJA ROAD NEAR HANUMAN MANDIR HARINAGAR SHIV PURAM PHASE 1 HALDWANI NAINITAL UTTARAKHAND 263139 | NAINITAL | UTTARAKHAND | 263139 | L3 | Rejected-AOC Ok | |
| 4 | L4₹28.8 L+₹3.5 L (13.9%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | L4 | Rejected-AOC Ok | |
| 5 | L5₹29.6 L+₹4.3 L (17.0%)Rejected-AOC | L5 | Rejected-AOC Ok |
| Sl No | Description | Qty | Unit | KRISHANA ELECTRIC WORKS L7 | Balraj and Co L5 | M/s badrinath Traders L2 | JS CONSTRUCTION COMPANY L9 | Mani Control System L10 | M/S Durvish Mourya L6 | prabhawati shanti automobiles L1 | M/s Kamal Traders L4 | Meher enterprises L8 | M/S K K ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth in soft/loose soil for laying/taking out under ground cable and getting out the excavated soil complete all as directed. | 337 | Cum | 100 ₹33,700 | 130 ₹43,810 | 120 ₹40,440 | 300 ₹1,01,100 | 200 ₹67,400 | 80 ₹26,960 | 120 ₹40,440 | 80 ₹26,960 | 250 ₹84,250 | 50 ₹16,850 Lowest |
| 2.00 | Returning, filling in trenches including spreading, leveling, watering and well roaming in layers not exceeding 25 cm thick in soft/loose soil after cable laid and testing complete all as directed. | 220 | Cum | 20 ₹4,400 | 40 ₹8,800 | 30 ₹6,600 | 100 ₹22,000 | 15 ₹3,300 Lowest | 30 ₹6,600 | 35 ₹7,700 | 20 ₹4,400 | 40 ₹8,800 | 25 ₹5,500 |
| 3.00 | Removing the excavated soil to a distance not exceeding 50 m and depositing where directed at a level not more than 1.5 m above the strutting point complete all as directed. | 117 | Cum | 20 ₹2,340 | 50 ₹5,850 | 30 ₹3,510 | 100 ₹11,700 | 5 ₹585 Lowest | 30 ₹3,510 | 25 ₹2,925 | 20 ₹2,340 | 60 ₹7,020 | 25 ₹2,925 |
| 4.00 | Supply and filling sand in trenches around under ground cable (sand cushion) complete all as directed. | 81 | Cum | 450 ₹36,450 | 800 ₹64,800 | 500 ₹40,500 | 600 ₹48,600 | 300 ₹24,300 | 300 ₹24,300 | 390 ₹31,590 | 500 ₹40,500 | 900 ₹72,900 | 200 ₹16,200 Lowest |
| 5.00 | Material and labour for un-reinforced precast concrete cable cover LV type I, flat size 250 mm X 150 mm X 40 mm as protection to underground cable laid dry and flat adjoining each other complete all as directed. | 6,600 | Each | 25 ₹1,65,000 | 18 ₹1,18,800 | 18 ₹1,18,800 | 20 ₹1,32,000 | 15 ₹99,000 Lowest | 25 ₹1,65,000 | 17 ₹1,12,200 | 20 ₹1,32,000 | 35 ₹2,31,000 | 15 ₹99,000 Lowest |
| 6.00 | S&F double wall corrugated pipe for laying of electric cable of size 50mm outer diameter and 38mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. | 500 | RM | 60 ₹30,000 | 85 ₹42,500 | 70 ₹35,000 | 100 ₹50,000 | 120 ₹60,000 | 80 ₹40,000 | 70 ₹35,000 | 150 ₹75,000 | 75 ₹37,500 | 50 ₹25,000 Lowest |
| 7.00 | S&F double wall corrugated pipe for laying of electric cable of size 63mm outer diameter and 51mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed. | 990 | RM | 70 ₹69,300 | 115 ₹1,13,850 | 100 ₹99,000 | 140 ₹1,38,600 | 150 ₹1,48,500 | 90 ₹89,100 | 80 ₹79,200 | 180 ₹1,78,200 | 110 ₹1,08,900 | 60 ₹59,400 Lowest |
| 8.00 | Material and Labour for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping of poles/stays including form work and dismantling of existing PCC complete all as directed. | 1 | Cum | 1,000 ₹1,000 | 4,500 ₹4,500 | 3,000 ₹3,000 | 6,000 ₹6,000 | 1,500 ₹1,500 | 300 ₹300 Lowest | 3,799 ₹3,799 | 5,000 ₹5,000 | 4,000 ₹4,000 | 3,500 ₹3,500 |
| 9.00 | Material and Labour for cement concrete 1:4:8 type D2 ( using 40 mm graded stone aggregate) for foundation of pole/stay including form work and dismantling of existing PCC complete all as directed. | 1 | Cum | 1,000 ₹1,000 | 4,000 ₹4,000 | 3,000 ₹3,000 | 5,000 ₹5,000 | 1,500 ₹1,500 | 350 ₹350 Lowest | 3,400 ₹3,400 | 5,000 ₹5,000 | 3,000 ₹3,000 | 3,000 ₹3,000 |
| 10.00 | Material and Labour for galvanised steel tubes light grade 40 mm bore dia with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as directed. | 18 | RM | 250 ₹4,500 | 250 ₹4,500 | 100 ₹1,800 Lowest | 250 ₹4,500 | 150 ₹2,700 | 250 ₹4,500 | 190 ₹3,420 | 250 ₹4,500 | 240 ₹4,320 | 210 ₹3,780 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Jul 2025, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
REPAIR AND MAINTENANCE OF STREET LIGHT, POST LIGHTS INCLUDING CONNECTED WORKS IN SOUTH CAMPUS UNDER GE IMA DEHRADUN. OF OTM AND MD ACCN UNDER GE IMA DEHRADUN.
2025_MES_716760_1
GE/IMA/T-51 OF 2025-26 9565/E8
Open Tender
Electrical and Maintenance Works
Item Rate
GE IMA Dehradun
As per tender documents
6 documents required · 6 mandatory
₹500
Yes
₹90,000
Yes
22 Aug 2025
25 Jun 2025
23 Jul 2025
26 Jun 2025
16 Jul 2025
9 Jul 2025
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth in soft/loose soil for laying/taking out under ground cable and getting out the excavated soil complete all as directed.
Returning, filling in trenches including spreading, leveling, watering and well roaming in layers not exceeding 25 cm thick in soft/loose soil after cable laid and testing complete all as directed.
Removing the excavated soil to a distance not exceeding 50 m and depositing where directed at a level not more than 1.5 m above the strutting point complete all as directed.
Supply and filling sand in trenches around under ground cable (sand cushion) complete all as directed.
Material and labour for un-reinforced precast concrete cable cover LV type I, flat size 250 mm X 150 mm X 40 mm as protection to underground cable laid dry and flat adjoining each other complete all as directed.
S&F double wall corrugated pipe for laying of electric cable of size 50mm outer diameter and 38mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
S&F double wall corrugated pipe for laying of electric cable of size 63mm outer diameter and 51mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
Material and Labour for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping of poles/stays including form work and dismantling of existing PCC complete all as directed.
Material and Labour for cement concrete 1:4:8 type D2 ( using 40 mm graded stone aggregate) for foundation of pole/stay including form work and dismantling of existing PCC complete all as directed.
Material and Labour for galvanised steel tubes light grade 40 mm bore dia with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as directed.
Material and Labour for galvanised steel tubes light grade 50 mm bore dia with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as directed.
Material and Labour forbracket for street light galvanised steel tubes light grade 40 mm bore dia length 1.20RM including welding, bend to shape and fixed with 2 SET 40X3MM FI clamp including nuts and bolts complete all as directed.
Fixing only LED street light fittings of any wattage capacity including taking down existing fitting of any type and in any position complete all as directed.
S&F driver for LED street light 60 Watt alongwith necessary connections complete all as directed.
S&F driver for LED street light 70 Watt alongwith necessary connections complete all as directed.
S&F driver for LED street light 90 Watt alongwith necessary connections complete all as directed.
S&F driver for LED street light 120 Watt alongwith necessary connections complete all as directed.
Supply and fix LED flood light fitting 50 watt cool/warm white as per requirement with not less than 100 LPW energy saving and enviromental friendly long life exclusive innovative made up of pressure die cast aluminium housing IP 66 with high power LED as lightnig source, suitable for highlighting archtectural features or area lighting also suitable for rough services/ installations including taking down existing fitting of any type and in any position complete all as directed. Make:Philips, Havells Crompton
Supply and fix LED flood light fitting 120 watt cool/warm white as per requirement with not less than 100 (Lumans per watt) LPW energy saving and enviromental friendly long life exclusive innovative made up of pressure die cast aluminium housing IP66 with high power LED as lightnig source and secondary lenses, suitable for highlighting archtectural facade and general purpose lighting including taking down existing fitting of any type and in any position complete all as directed. Make:Philips, Havells Crompton,
Supply and fix LED flood light fitting 150 watt cool/warm white as per requirement with not less than 100 LPW energy saving and enviromental friendly long life exclusive innovative made up of pressure die cast aluminium housing IP66 with high power LED as lightnig source and secondary lenses, suitable for highlighting archtectural facade and general purpose lighting including taking down existing fitting of any type and in any position complete all as directed. Make:Philips, Havells Crompton
Supply and fix LED flood light fitting 200 watt cool/warm white with not less than 100 LPW energy saving and enviromental friendly long life exclusive innovative made up of pressure die cast aluminium housing IP66 with high power LED as lightnig source and secondary lenses, suitable for highlighting archtectural facade and general purpose lighting including taking down existing fitting of any type and in any position complete all as directed. Make: Philips, Havells Crompton
Supply and fix post top light fitting 25 watt energy saving and enviromental friendly long liife aesthetically designed with symmetrical light distribution, spun aluminiun landscape luminaire with high power LEDs as light source, suitable for pole dia 76 mm (max) including taking down existing fitting of any description complete all as directed. Make: Philips, Havells Crompton
Supply and fix pole mounted LT junction box, Water proof and fire proof, sheet moulding compound (SMC) box of inside size 250 mm x 200 mm x100 mm deep complete with 4 nos terminal end aluminium strip of 20 x 4 mm size fixing cable end terminal and 3 nos MS bolts and nut of size 8 mm dia x 30 mm long and MCB mounting rail with 6 Amp MCB SP duly welded with box fixed on plle with MS clamp 25 mm x 3 mm MS strip duly painted and testing including taking down existing complete all as directed. Make: Sintex/ Hensel/ Shalabh
Supply and fix non mattalic shock proof and rust proof pole mounted junction box of size 140mm x 140mm x 90mm for garden lighting system complete with all accessories and including MCB SP 6 Amp, 100 Amp rated heavy aluminium bus bar mounting on shaddle, 2 terminals, pole clamp with nut bolts etc with necessary mounting arrangement in the junction box with pole all as specifed and directed.Make: Sintex Industries Ltd/ Supreme Industries/ Naithani Plastic Moulding Works.
Material and Labour for bus bar chamber pedestal type of size 75 cm x 60 cm x 40 cm out door dust & vermin proof front opening made out of 2.0 mm thick MS sheet duly painted and consisting with aluminium bus bar 3 phase and neutral 4 Nos 250 Amp fixed on insulators and one MCCB FP 160 Amp, 25 KA rupturing capacity including fixed in PCC 1:3:6 using 20 mm graded stone aggregate and MS stand including danger plate etc including taking down existing LT feeder bus bar complete all as directed.
Supply and fix street light control panel 415 Vatt AC, outdoor type, pole/flour mounted made from 2.00 mm thick MS sheet min size 50 cm x 40 cm x 12 cm deep complete with 4 Nos mounting bolts of size 10 mm dia x 50 mm long fixed with 20 mm x 4 mm size MS strip with astronomical timer, contactor of 65 Amp rating 3 phase 1 Nos, MCB TPN 63 Amp of capacity 01 Nos, of capacity 12 KW including taking down existing panel complete all as directed. Make: Havells, L&T, Legrand.
Supply and fix street light control panel 415 vatt AC, outdoor type, pole/flour mounted made from 2.00 mm thick MS sheet min size 50 cm x 40 cm x 12 cm deep complete with 4 Nos mounting bolts of size 10 mm dia x 50 mm long fixed with 20 mm x 4 mm size MS strip with astronomical timer, contactor of 65 Amp rating Single Phase 1 No MCB SPN 63 Amp 12 KW including taking down existing panel complete all as directed Make: Havells, L&T, Legrand.
Taking out existing old damaged / unserviceable LT UG cable, PVC/XLPE insulated any size, steel strip /wire armoured multistranded aluminium conductor cable from trench /duct /pipe. etc of any sizes complete all as specified and as directed.
Supply and fix XLPE cable insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade confirm to relevent IS, cross-sectional area 120 sq mm 3.5 core complete all as directed.
All as per item No 29 above but size 95 Sqmm 3.5 core
All as per item No 29 above but size 70 Sqmm 3.5 core
All as per item No 29 above but size 50 Sqmm 3.5 core
All as per item No 29 above but size 16 Sqmm, 4 Core
All as per item No 29 above but size 10 Sqmm, 4 Core
All as per item No 29 above but size 6 Sqmm, 4 Core
Material and Labour for cable jointing kit for 1100 V grade cable for indoor/outdoor End joint heat shrinkable type complete with jointing material suitable for 16 to 50 sq mm 3.5/4 core PVC/XLPE insulated and sheathed armoured cable complete all as directed. Make: Denson/M Seal/Cabseal.
All as per item No 36 above but Size 70 to 150 sq mm 3.5/4 core
Material and Labour for cable jointing kit for 1100 V grade cable for straight through joint heat shrinkable type complete with jointing material suitable for 16 to 50 sq mm 3.5 core PVC/XLPE insulated and sheathed armoured cable complete all as directed. Make: Denson/M Seal/Cabseal.
All as per item No 38 above but size 70 to 150 Sqmm, 3.5 core
Material and Labour for painting of (9 meter long steel) street light pole complete with one coat of synthetic enamel aluminium paint and preparation of surface including writing of pole Nos with black enamelled paint not less than 100mm height complete all as directed.
Supply and fixing in renewal LT Pole (s) of old u/s digital 24 Hr timer suitable for street light control panel AC complete all as directed. Make : L&T cat part No. 67DDT0 or equivalent model in Siemens, Legrand.
Material and labour for MCB SPN 63 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as directed. Make: Legrand, L&T, ABB, Schneider, C&S.
Material and labour for MCB TPN 63 Amps, 415 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as directed. Make: Legrand, L&T, ABB, Schneider, C&S.
Material and Labour for PVC wire with copper conductor 1100 Volts grade Cross section area of size 1.5 Sq mm 3 Core laid in trenches/pole complete all as directed. Make:Gloster/Havells/Polycab
Material and Labour for steel tubular swaged pole 9 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, including painting with anti corrosive paint internally complete and externally complete with two coat of synthetic enamel aluminium paint over a coat of red oxide primer and preparation of surface including marking of pole Nos with black paint complete all as directed.
Material and labour for MCCB 100 Amps,4 pole 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having including taking out existing unserviceable MCCB complete all as directed. Make: Legrand, L&T, ABB, Schneider.
Material and labour for MCCB 125 Amps, 4 pole 415 volts with rupturing capacity 16 KA with thermal magnetic release and adjustable overload setting having including taking out existing unserviceable MCCB complete all as directed. Make: Legrand, L&T, ABB, Schneider.
Supply and fix LED bollard light 10 Watt IP 65 cool/warm white as per requirement pressure die cast powder coated housing PC diffuser of model matching with site requirement including all fixing arrangement,PCC work and elect connections complete all as specified and directed.
M&L Earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised iron strip 25×4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron and protected with 40 mm dia light grade GI pipe all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6 mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10 mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) 40 mm thick cover, reinforced with 8 mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40 mm dia GI light grade earth lead protection pipe etc complete all as specified and directed.
Material and labour for MCB SP 6-32 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs complete all as directed. Make: Legrand, L&T, ABB, Schneider, C&S.
M/s badrinath Traders (BID ID -3360445)
M/S K K ENTERPRISES (BID ID -3361267)
M/s Kamal Traders (BID ID -3360990)
Balraj and Co (BID ID -3360360)
M/S Durvish Mourya (BID ID -3360798)
KRISHANA ELECTRIC WORKS (BID ID -3353332)
Meher enterprises (BID ID -3361155)
JS CONSTRUCTION COMPANY (BID ID -3361257)
Mani Control System (BID ID -3358712)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .