Divisional Engineer-(Electrical), Tirumala
ATO
Replacement of existing life over, defective tube light fittings with new linear LED batten fittings at marketting godown, Nandakam,KKC,Sevasadan-2, PAC-4 dining hall in ESD-North,Tirumala
925534
10/DE(Elec)Tml/TTD/2026-27
OPEN - NCB
Electrical Works
TIRUPATHI
7 documents required · 7 mandatory
₹286
₹20,200
22 May 2026
23 Apr 2026
23 Apr 2026
Supply of Linear LED Batten with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 125 lm/W. System wattage should not exceed 35W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a colour temperature of 6500K and CRI>80. Driver of the luminaire shall have THD < 10% and PF > 0.95. The luminaire housing should be made of CRCA with a PC glossy diffuser. The driver shall comply to IEC 60598, IEC 62384 , IEC 61347-2-13, IEC 61547, EMI- CISPR15 standards. Make: Philips BN308C LED40S-6500 L12O PSU WH/TTD approved Brands
Fixing of given Tube light luminaire / PL fitting on wall / Ceiling / Trusses / Channels on PVC/ TW round blocks / Epoxy insulator / 3"x2"x1" TW reaper with all accessories, labour charges and giving necessary connections.
Dismantling of existing fixture's such as 2' /4' tube light fitting / PL fitting with out causing any damage to the fittings etc., (Note: The dismantled above material are to be returned to concerned section officer by the contractor at his cost)
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
Supply of Linear LED Batten with a nominal system lumen output of 4000 lumens and a minimum system efficacy of 125 lm/W. System wattage should not exceed 35W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a colour temperature of 6500K and CRI>80. Driver of the luminaire shall have THD < 10% and PF > 0.95. The luminaire housing should be made of CRCA with a PC glossy diffuser. The driver shall comply to IEC 60598, IEC 62384 , IEC 61347-2-13, IEC 61547, EMI- CISPR15 standards. Make: Philips BN308C LED40S-6500 L12O PSU WH/TTD approved Brands
Fixing of given Tube light luminaire / PL fitting on wall / Ceiling / Trusses / Channels on PVC/ TW round blocks / Epoxy insulator / 3"x2"x1" TW reaper with all accessories, labour charges and giving necessary connections.
Dismantling of existing fixture's such as 2' /4' tube light fitting / PL fitting with out causing any damage to the fittings etc., (Note: The dismantled above material are to be returned to concerned section officer by the contractor at his cost)
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
(Rupees Eighty lakhs six thousands six hundred sixty nine and paise eighty only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQ 10.xls
TENDER_DOCUMENT • 2.00 MB
NIT 10.docx
TENDER_DOCUMENT • 0.16 MB
NIT 10.xlsx
TENDER_DOCUMENT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .