Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC THE LOWEST BIDDER | |
| 2 | L2₹28.7 L+₹99,600 (3.59%)Rejected-Finance D NO 58 22 34 9 PYDIMAMBA NILAYAM BUTCHIRAJUPALEM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹34.0 L+₹6.2 L (22.5%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | Rejected-Technical H1 7 8 IT PARK ROAD NO 4 IPIA KOTA RAJ 324005 | KOTA | RAJASTHAN | 324005 | - | Rejected-Technical Please see TSC | |
| 5 | Rejected-Technical | - | Rejected-Technical Please see TSC |
Tender Value
₹36.6 L
EMD Value
₹73,200
Closing Date
1 Jul 2025, 6:00 pmClosed
GE(I)CG VIZAG
GE (I) (CG) Vizag, Military Engineer Services, CGWO Building, C/o Fleet Mail Office, Visakhapatnam, PIN-530011
COMPREHENSIVE MAINTENANCE OF VARIABLE REFRIGERANT FLOW AIR CONDITIONING AT HQ CGC AND SPORTS COMPLEX AT VISAKHAPATNAM
2025_MES_714123_1
GE(I)CG/VIZ/TOKEN 20 OF 2025-26
Open Tender
Miscellaneous Works
Item Rate
365 days
VISAKHAPATNAM
DETAIL AS PER NIT OF THE TENDER
9 documents required · 9 mandatory
₹500
GE(I)(CG) VIZAG
₹73,200
Yes
5 Aug 2025
12 Jun 2025
3 Jul 2025
12 Jun 2025
1 Jul 2025
25 Jun 2025
Amount
Comprehensive Maintenance of VRF AC casseets mounting set of the following capacities which include replacement of filter, warn out parts, charging of refrigerant, Electric connection, MCBs, Control System, fault finding and its rectification to ensuring the system work in entire satisfaction of Engr-in-Charge of Out door unit 22 HP - 01 Nos, 24 HP - 01 Nos & 28 HP - 02 Nos, connecting pipe lines and connected Indoor units of BLUE STAR Make complete all as specified and directed.
Comprehensive Maintenance of VRF AC casseets mounting set of the following capacities which include replacement of filter, warn out parts, charging of refrigerant, Electric connection, MCBs, Control System, fault finding and its rectification to ensuring the system work in entire satisfaction of Engr-in-Charge of Out door unit 16 HP - 04 Nos, 20 HP - 03 Nos & 22 HP - 02 Nos, connecting pipe lines and connected Indoor units of LG Make complete all as specified and directed.
Comprehensive Maintenance of VRF AC casseets mounting set of the following capacities which include replacement of filter, warn out parts, charging of refrigerant, Electric connection, MCBs, Control System, fault finding and its rectification to ensuring the system work in entire satisfaction of Engr-in-Charge of Out door unit 12 HP - 07 Nos & 10 HP - 01 Nos, connecting pipe lines and connected Indoor units of MITSUBISHI Make complete all as specified and directed.
Comprehensive Maintenance for 02x Air Handling Units (AHU PAC AH500/250, Make- Mitsubishi) including periodic preventive maintenance, inspection, cleaning of filters, blower, and coils, lubrication of moving parts, checking electrical connections, belt alignment, vibration analysis, and overall performance monitoring, fault finding and its rectification to ensuring uninterrupted and efficient operation of AHUs entire satisfaction of Engr-in-Charge all as specified and directed.. Note for item 1 to 4 :- a) The Maintenance of the VRF ACs/ AHU shall be done through OEM or firm authorised by the OEM only. b) The parts being replaced/repaird shall be genuine and from original equipment manufacturer (OEM) and approved by GE . Cost of parts/ routine material required for above mentioned maintenance is deemed to be included in the quoted rate. c) All software update required for smooth functioning of VRF ACs shall be undertaken by OEM only. d) Periodical Servicing of each VRF Acs/ AHU to be carried out by company technician and records/logbook shall be maintained at Engr-in-Charge. e) The compressor will be checked for its proper functioning and if any defect is found, the same will be repaired/replaced. f) Safety control such as pressure cut outs will be tested for proper functioning and in case of any mal functioning, they will be either repaired or replaced accordingly. g) The PCB of the IDU & ODU will be tested for proper functioning and in case of any malfunctioning, they will be either repaired or replaced accordingly. h) Nitorgen pressure testing, vaccumaizing and gas charging, if necessary. j) Air filter will be inspected and cleaned or replaced, if necessary k) The comprehensive maintenance work of ACs/ AHU shall be carried out by OEM only. Tenderers shall upload the MoU between contractor & OEM alongwith tender documents during submission of tenders otherwise bid shall be liable to reject in technical evaluation by the TIA if MoU not found submitted/uploaded during bid submission. The documents of MoU between contractor & OEM shall be Registered/ Notarised. l) The work are mentioned above shall deemed included in qouted rate.
P VENKATA RAO (BID ID -3342264)
Sri Jaya Surya Techs (BID ID -3342610)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .