Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 18 398A MUNDAKAYAM MUNDAKKAYAM MUNDAKAYAM KOTTAYAM KERALA 686513 | KOTTAYAM | KERALA | 686513 | Admitted-Finance |
| 2 | Admitted-Finance 2 SBC 1 THEJASWINI BUILDING PHASE 1 TECHNOPARK THIRUVANANTHAPURAM 695581 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695581 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Technically not qualified |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
25 Mar 2023, 11:00 amClosed
Manager Projects
KEL Kochi
SUPPLY, TESTING, INSTALLATION AND COMMISIONING AND MAINTENANCE OF CUSTOMIZED CONTAINER CABIN, BOOM BARRIER AND SURVELLIANCE SOLUTION AT MUTHANGA, PATTAVAYAL, THOLPETTY, WAYANAD DISTRICT
2023_KEL_566759_1
KRO/ BDC/1363/2023
Open Tender
Civil Works - Others
Item Rate
360 days
KEL Kochi
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹50,000
Yes
27 Mar 2023
16 Mar 2023
27 Mar 2023
16 Mar 2023
25 Mar 2023
16 Mar 2023
16 Mar 2023 - 23 Mar 2023
Amount
Supply, Testing, Installation & Commissioning and Maintenance of Customized Container Cabin,Boom barrier and Surveillance Solution at WAYANAD (THOLPETTI)
Base Frame: Consists of Bottom Side Rails, Cross Members and Longitudinal Spacing Member welded as Sub-Assembly. Angle Sections to seat Floor of Marine-grade Plywood. a. Side Bottom Rail: Gauge> Outer & Longitudinal Geometry> Outer: ISMC 125mm; Longitudinal Spacing Member: Cold-formed Channel Section Assembly>Side Rail Longitudinal Joint Sections, fully welded; inner angle sections stitch-welded to accept floor board b. Cross Member: Gauge> ISMC 125mm. 14 nos; Geometry> ISMC MS Channel Section. Assembly> Continuous welding to bottom side rails on one side of cross member and longitudinal spacing sections c. Cladding Sheet below Plywood Floor: Gauge>1mm thick galvanised. Assembly>Spread over d. Floor: Gauge> 18 mm Thickness Marine Grade Plywood + Vinyl. Assembly> Floor board fixed to the cross members with electro-zinc plated screws. All joints between each board and periphery of the floor sealed with elastic butyl sealant.
Side Walls: Assembly of Longitudinal side panels. Trapezoidal Corrugated sections panels for Side Walls. Cut-out edges on Side Walls for Door and Windows provided with channel sections to accept pre-fab aluminium windows and door. No of windows: 4 No of doors: 2 a. Panel: Gauge: 1.2mm CR Sheets; Geometry: Shallow Trapezoidal corrugated section; Assembly> Butt-welded to form one panel; Features: Fully corrugated b. Top side Rail: Geometry> 60 x 60 x 2.9 mm thick square tube c. Vertical & horizontal sections for doors & windows: Geometry> Formed Channel Sections / Rolled Hollow Sections. d. Panelling: Double side Laminated MDF Board Thickness: 8mm
End Walls: Trapezoidal Corrugated sections panels for front and rear ends. End Assembly comprises top member, corner posts and end bottom member with panels fully welded to these members. Corner fitting with aperture at four edges for lifting the container.a. End Top Member (End Header): Geometry> 60 x 60 x 2.9mm thick square tube; Assembly> Fully welded at corner posts, panels, and roofb. Corner Post: Gauge> 100x100x8mm angle Geometry> Formed Sections; Assembly> Fully welded at panels and corner fittings.c. End Bottom Member (End Sill): Geometry> Channel Section ISMC 125.d. Corner Fittings: Geometry> ISO dimensions; Assembly> Fully-welded at panels and corner fittings.e. Panel: Similar as side panel.
Roof: Corrugated Sheets with Stiffeners or with Side/End make-up section, fully welded to end Top member and Top side rail with necessary camber for water drainage. a. Roof Sheet: Gauge>1.2 mm; Geometry>. Corrugated Panel b. Make-up sections: Gauge>0.46 mm; Geometry> Formed hat section to accept slope of, Aluminium corrugated roofing sheet c. Assembly: Forming a continuous roof sheet, welded joints at longitudinal and transverse edges, lapped to the end Top member and Top side Sq.tube
Lining Members: Provided on the sides, ends, and roof to accept internal insulation and panelling. Stitch-welded to form grid structure. a. Gauge>1.2 mm; Geometry> Formed angular sections
Painting Scheme: After full assembly and welding, the unit shall be acid cleaned, coated with corrosionresistant primer at all steel surface areas. Base/floor will be bitumen-coated. a. Exterior: Zinc Rich Primer; Intermediate coat; Top Coat b. Interior: Zinc Rich Primer; Intermediate Coat c. Underside: Zinc Rich Primer; Bitumen Undercoat. d. Superstructure Finish: Saten Enamel Spray Paint e. Under-structure Finish: Black Bitumen Pain
Door(s) and Windows: The following fitments will be made. a. External Security Door> Steel Hinged Door b. No. of Doors: 2 (two) c. Internal Door> Aluminium Half Glass Doord. No. of Doors: 1 (one) e. Internal Door> Aluminium sliding Half glass doorf. No. of Doors: 2 (two)g. Window: Sliding window-Alu.frame with Glass panelh. No. of Window: 4 (four)
Insulation & Interior Panelling a. All internal panels (sides and roof) except floor provided with Thermocol insulation of 25mm Thickness. b. Same will be panelled using MDF with 8 mm
Electricals: External Weatherproof Power Input Socket, Distribution Box with Isolator, Mini-Circuit Breakers, ELCB. PVC Insulated Cables in Conduits or Casing-and-Capping
Toilet/Bathroom: European Style WC with cistern , Health Faucet, Water Faucet, Towel Rod, Soap Dish, Wash basin, Mirror, Brush holders
Furniture: i. Bed: 190x90cm – 3nos. ii. Table 2nos
Manually operated Customized Boom barrier (13 m length,3"-2.5"-2" diameter ).Specifications:Mounting posts are made of 4 inch MS C channels and 13m booms are made by 3,2.5,2 inch MS Pipes with additional protection given by providing 2x1 inch square tubes.Supporting post is made of 4 inch Single C channel and Weight basket is made of 1x1/4 inch L channels with inside dimensions of 2x2 feet.Boom barrier is coated with two layers of epoxy primer paints and Red& White metal paints.Sign boards and reflective stickers are fixed on both side of the Boom barrier.RCC Footing Measurements:.65mx.65mx.80m M25 Concrete for Mounting Post and .30mx.30mx.30m M25 Concrete for Supporting Post.
Camera Mounting Cross bar with 5 inch * 7M vertical and 4 inch *13M horizonal posts connected by a T flange.Specifications:Poles are made of 5 inch diameter with medium gauge,7m tall GI post on both sides of the road ,fixed in ground with concrete footing. Cross bar is made of 4 inch dia with medium gauge GI Pipe,fixed at a height of 6m from ground on 7m tall vertical posts.Two layers of epoxy primer and paints will be applied.RCC Footing Measurements: .80mx.80mx1m M25 Concrete for Camera mounting cross bar footing.
Single phase KSEB Connection with One year bill Payment (Initial connection charge 15000/- and Twomonth Bill Amount 20000/-(Approximate)
Internet Connection with One year Bill Payment
Charges for Providing Water Connection from nearest Water Sources. (Includes Water pump,Pvc pipes and Plumbing accessories)
Split Inverter type AC 1 ton.Specifications;AI Dual inverter, AI Convertible 6 in 1 Cooling,Artificial Intelligence Cooling Mode, ADC Sensor ,4 Way Swing, HD Filter with Anti Virus Protection. Provides One year warrenty and two year service support
LED Flood Light 100W.Specification:240 volts,100 wattage,9000 lumen,White colour,Electric corded,IP65 Waterproof and IK07 Mechanical shock ratings,Elegant and Power saving and integrated design,no bulb replacements plus 70% light output maintenance to 30000 hours
Wall mountable Fan.Specifications:Electric Spind Cabin 300mm Ultra High Speed 3 Blade,air delivery of 4800 CMM,Boasting high speeds of up to 2000rpm.Equipped with a powerful motor and aerodynamically desidned blades,this cabin fan delivers effective cooling
LED Tube Light, 20W LED Cool Day Light Batten. Specifications:Better lumens and longer lamp life,High efficacy and lower power consumption,No UV or IR radiations as it does not contain mercury
2.5 sqmm PVC Insulated Wire
1.5 sqmm PVC Insulated Wire
5MP Varifocal camera(3.6 to12mm),1/2.8-in.5 MP Progressive scan CMOS Sensor,2592x1944 at 20 fps max resolution,3.6mm to 12mm motorized verifocal lens,true wide dynamic range(120dB) and 2D/3D noise reduction,Max IR Length 80m,Smart IR,IP67 Ingress protection,Dual power input,24VAC OR 12VDC
Outdoor CAT6 cable
1.5 sqmm 3core flexible wire
8 chanel NVR/4k,2 SATA HDD Slot Max 12TB 12 VDC
4 TB surveillance HDD
2.5 sqmm Armoured cable
25mm HDPE hose
6core OFC
4 U rack with PDU
32 inch LED monitor
CAT 6 indoor cable
2 KVA/24V,1760 Watts 2 battery system(24DC) UPS,DSC Based intelliPure Sinewave UPS, LED&LCD Display indications,PWM Controlled Multistage Charging,Smart overload sense,short circuit and over temperature protection ,With 200AH (2 nos)Battery
Media converters, PoE Switches, Network Switches, JB/Pannel boxes,RJ45 Jacks,IP67 JB,AC DB, Conduit and electrical fittings,Switch with socket /box, Trenching and all accessories required for the completion of the Project.
Professional charges for Testing and Commissioning
Supply, Testing, Installation & Commissioning and Maintenance of Customized Container Cabin,Boom barrier and Surveillance Solution at WAYANAD (MUTHANGA)
Base Frame: Consists of Bottom Side Rails, Cross Members and Longitudinal Spacing Member welded as Sub-Assembly. Angle Sections to seat Floor of Marine-grade Plywood. a. Side Bottom Rail: Gauge> Outer & Longitudinal Geometry> Outer: ISMC 125mm; Longitudinal Spacing Member: Cold-formed Channel Section Assembly>Side Rail Longitudinal Joint Sections, fully welded; inner angle sections stitch-welded to accept floor board b. Cross Member: Gauge> ISMC 125mm. 14 nos; Geometry> ISMC MS Channel Section. Assembly> Continuous welding to bottom side rails on one side of cross member and longitudinal spacing sections c. Cladding Sheet below Plywood Floor: Gauge>1mm thick galvanised. Assembly>Spread over d. Floor: Gauge> 18 mm Thickness Marine Grade Plywood + Vinyl. Assembly> Floor board fixed to the cross members with electro-zinc plated screws. All joints between each board and periphery of the floor sealed with elastic butyl sealant.
Side Walls: Assembly of Longitudinal side panels. Trapezoidal Corrugated sections panels for Side Walls. Cut-out edges on Side Walls for Door and Windows provided with channel sections to accept pre-fab aluminium windows and door. No of windows: 4 No of doors: 2 a. Panel: Gauge: 1.2mm CR Sheets; Geometry: Shallow Trapezoidal corrugated section; Assembly> Butt-welded to form one panel; Features: Fully corrugated b. Top side Rail: Geometry> 60 x 60 x 2.9 mm thick square tube c. Vertical & horizontal sections for doors & windows: Geometry> Formed Channel Sections / Rolled Hollow Sections. d. Panelling: Double side Laminated MDF Board Thickness: 8mm
End Walls: Trapezoidal Corrugated sections panels for front and rear ends. End Assembly comprises top member, corner posts and end bottom member with panels fully welded to these members. Corner fitting with aperture at four edges for lifting the container.a. End Top Member (End Header): Geometry> 60 x 60 x 2.9mm thick square tube; Assembly> Fully welded at corner posts, panels, and roofb. Corner Post: Gauge> 100x100x8mm angle Geometry> Formed Sections; Assembly> Fully welded at panels and corner fittings.c. End Bottom Member (End Sill): Geometry> Channel Section ISMC 125.d. Corner Fittings: Geometry> ISO dimensions; Assembly> Fully-welded at panels and corner fittings.e. Panel: Similar as side panel.
Roof: Corrugated Sheets with Stiffeners or with Side/End make-up section, fully welded to end Top member and Top side rail with necessary camber for water drainage. a. Roof Sheet: Gauge>1.2 mm; Geometry>. Corrugated Panel b. Make-up sections: Gauge>0.46 mm; Geometry> Formed hat section to accept slope of, Aluminium corrugated roofing sheet c. Assembly: Forming a continuous roof sheet, welded joints at longitudinal and transverse edges, lapped to the end Top member and Top side Sq.tube
Lining Members: Provided on the sides, ends, and roof to accept internal insulation and panelling. Stitch-welded to form grid structure. a. Gauge>1.2 mm; Geometry> Formed angular sections
Painting Scheme: After full assembly and welding, the unit shall be acid cleaned, coated with corrosionresistant primer at all steel surface areas. Base/floor will be bitumen-coated. a. Exterior: Zinc Rich Primer; Intermediate coat; Top Coat b. Interior: Zinc Rich Primer; Intermediate Coat c. Underside: Zinc Rich Primer; Bitumen Undercoat. d. Superstructure Finish: Saten Enamel Spray Paint e. Under-structure Finish: Black Bitumen Pain
Door(s) and Windows: The following fitments will be made. a. External Security Door> Steel Hinged Door b. No. of Doors: 2 (two) c. Internal Door> Aluminium Half Glass Doord. No. of Doors: 1 (one) e. Internal Door> Aluminium sliding Half glass doorf. No. of Doors: 2 (two)g. Window: Sliding window-Alu.frame with Glass panelh. No. of Window: 4 (four)
Insulation & Interior Panelling a. All internal panels (sides and roof) except floor provided with Thermocol insulation of 25mm Thickness. b. Same will be panelled using MDF with 8 mm
Electricals: External Weatherproof Power Input Socket, Distribution Box with Isolator, Mini-Circuit Breakers, ELCB. PVC Insulated Cables in Conduits or Casing-and-Capping
Toilet/Bathroom: European Style WC with cistern , Health Faucet, Water Faucet, Towel Rod, Soap Dish, Wash basin, Mirror, Brush holders
Furniture: i. Bed: 190x90cm – 3nos. ii. Table 2nos
Manually operated Customized Boom barrier (13 m length,3"-2.5"-2" diameter ).Specifications:Mounting posts are made of 4 inch MS C channels and 13m booms are made by 3,2.5,2 inch MS Pipes with additional protection given by providing 2x1 inch square tubes.Supporting post is made of 4 inch Single C channel and Weight basket is made of 1x1/4 inch L channels with inside dimensions of 2x2 feet.Boom barrier is coated with two layers of epoxy primer paints and Red& White metal paints.Sign boards and reflective stickers are fixed on both side of the Boom barrier.RCC Footing Measurements:.65mx.65mx.80m M25 Concrete for Mounting Post and .30mx.30mx.30m M25 Concrete for Supporting Post
Camera Mounting Cross bar with 5 inch * 7M vertical and 4 inch *13M horizonal posts connected by a T flange.Specifications:Poles are made of 5 inch diameter with medium gauge,7m tall GI post on both sides of the road ,fixed in ground with concrete footing. Cross bar is made of 4 inch dia with medium gauge GI Pipe,fixed at a height of 6m from ground on 7m tall vertical posts.Two layers of epoxy primer and paints will be applied.RCC Footing Measurements: .80m x .80m x1m M25 Concrete for Camera mounting cross bar footing.
Single phase KSEB Connection with One year bill Payment(Initial connection charge 15000/- and Two month Bill Amount 20000/-(Approximate)
Internet Connection with One year Bill Payment
Charges for Providing Water Connection from nearest Water Sources.(Includes Water pump,Pvc pipes and Plumbing accessories)
Split Inverter type AC 1 ton.Specifications;AI Dual inverter, AI Convertible 6 in 1 Cooling,Artificial Intelligence Cooling Mode, ADC Sensor ,4 Way Swing, HD Filter with Anti Virus Protection. Provides One year warrenty and two year service support
LED Flood Light 100W.Specification:240 volts,100 wattage, 9000 lumen,White colour,Electric corded, IP65 Waterproof and IK07 Mechanical shock ratings, Elegant and Power saving and integrated design, no bulb replacements plus 70% light output maintenance to 30000 hours.
Wall mountable Fan.Specifications:Electric Spind Cabin 300mm Ultra High Speed 3 Blade,air delivery of 4800 CMM, Boasting high speeds of up to 2000rpm. Equipped with a powerful motor and aerodynamically desidned blades, this cabin fan delivers effective cooling.
LED Tube Light, 20W LED Cool Day Light Batten.Specifications:Better lumens and longer lamp life,High efficacy and lower power consumption,No UV or IR radiations as it does not contain mercury
2.5 sqmm PVC Insulated Wire
1.5 sqmm PVC Insulated Wire
5MP Varifocal camera(3.6 to12mm),1/2.8-in.5 MP Progressive scan CMOS Sensor,2592x1944 at 20 fps max resolution,3.6mm to 12mm motorized verifocal lens,true wide dynamic range(120dB) and 2D/3D noise reduction,Max IR Length 80m,Smart IR,IP67 Ingress protection,Dual power input,24VAC OR 12VDC
Outdoor CAT6 cable
1.5 sqmm 3core flexible wire
8 chanel NVR/4k,2 SATA HDD Slot Max 12TB 12 VDC
4 TB surveillance HDD
2.5 sqmm Armoured cable
25mm HDPE hose
6core OFC
4 U rack with PDU
32 inch LED monitor
CAT 6 indoor cable
2 KVA/24V,1760 Watts 2 battery system(24DC) UPS,DSC Based intelliPure Sinewave UPS, LED&LCD Display indications,PWM Controlled Multistage Charging,Smart overload sense,short circuit and over temperature protection ,With 200AH (2 nos)Battery
Media converters,PoE Switches,Network Switches, JB/Pannel boxes, RJ45 Jacks, IP67 JB, AC DB, Conduit and electrical fittings, Switch with socket /box, Trenching and all accessories required for the completion of the Project.
Professional charges for Testing and Commissioning
Supply, Testing, Installation & Commissioning and Maintenance of Customized Container Cabin, Boom barrier and Surveillance Solution at WAYANAD (PAATAVAYAL)
Base Frame: Consists of Bottom Side Rails, Cross Members and Longitudinal Spacing Member welded as Sub-Assembly. Angle Sections to seat Floor of Marine-grade Plywood. a. Side Bottom Rail: Gauge> Outer & Longitudinal Geometry> Outer: ISMC 125mm; Longitudinal Spacing Member: Cold-formed Channel Section Assembly>Side Rail Longitudinal Joint Sections, fully welded; inner angle sections stitch-welded to accept floor board b. Cross Member: Gauge> ISMC 125mm. 14 nos; Geometry> ISMC MS Channel Section. Assembly> Continuous welding to bottom side rails on one side of cross member and longitudinal spacing sections c. Cladding Sheet below Plywood Floor: Gauge>1mm thick galvanised. Assembly>Spread over d. Floor: Gauge> 18 mm Thickness Marine Grade Plywood + Vinyl. Assembly> Floor board fixed to the cross members with electro-zinc plated screws. All joints between each board and periphery of the floor sealed with elastic butyl sealant.
Side Walls: Assembly of Longitudinal side panels. Trapezoidal Corrugated sections panels for Side Walls. Cut-out edges on Side Walls for Door and Windows provided with channel sections to accept pre-fab aluminium windows and door. No of windows: 4 No of doors: 2 a. Panel: Gauge: 1.2mm CR Sheets; Geometry: Shallow Trapezoidal corrugated section; Assembly> Butt-welded to form one panel; Features: Fully corrugated b. Top side Rail: Geometry> 60 x 60 x 2.9 mm thick square tube c. Vertical & horizontal sections for doors & windows: Geometry> Formed Channel Sections / Rolled Hollow Sections. d. Panelling: Double side Laminated MDF Board Thickness: 8mm
End Walls: Trapezoidal Corrugated sections panels for front and rear ends. End Assembly comprises top member, corner posts and end bottom member with panels fully welded to these members. Corner fitting with aperture at four edges for lifting the container.a. End Top Member (End Header): Geometry> 60 x 60 x 2.9mm thick square tube; Assembly> Fully welded at corner posts, panels, and roofb. Corner Post: Gauge> 100x100x8mm angle Geometry> Formed Sections; Assembly> Fully welded at panels and corner fittings.c. End Bottom Member (End Sill): Geometry> Channel Section ISMC 125.d. Corner Fittings: Geometry> ISO dimensions; Assembly> Fully-welded at panels and corner fittings.e. Panel: Similar as side panel.
Roof: Corrugated Sheets with Stiffeners or with Side/End make-up section, fully welded to end Top member and Top side rail with necessary camber for water drainage. a. Roof Sheet: Gauge>1.2 mm; Geometry>. Corrugated Panel b. Make-up sections: Gauge>0.46 mm; Geometry> Formed hat section to accept slope of, Aluminium corrugated roofing sheet c. Assembly: Forming a continuous roof sheet, welded joints at longitudinal and transverse edges, lapped to the end Top member and Top side Sq.tube
Lining Members: Provided on the sides, ends, and roof to accept internal insulation and panelling. Stitch-welded to form grid structure. a. Gauge>1.2 mm; Geometry> Formed angular sections
Painting Scheme: After full assembly and welding, the unit shall be acid cleaned, coated with corrosionresistant primer at all steel surface areas. Base/floor will be bitumen-coated. a. Exterior: Zinc Rich Primer; Intermediate coat; Top Coat b. Interior: Zinc Rich Primer; Intermediate Coat c. Underside: Zinc Rich Primer; Bitumen Undercoat. d. Superstructure Finish: Saten Enamel Spray Paint e. Under-structure Finish: Black Bitumen Pain
Door(s) and Windows: The following fitments will be made. a. External Security Door> Steel Hinged Door b. No. of Doors: 2 (two) c. Internal Door> Aluminium Half Glass Doord. No. of Doors: 1 (one) e. Internal Door> Aluminium sliding Half glass doorf. No. of Doors: 2 (two)g. Window: Sliding window-Alu.frame with Glass panelh. No. of Window: 4 (four)
Insulation & Interior Panelling a. All internal panels (sides and roof) except floor provided with Thermocol insulation of 25mm Thickness. b. Same will be panelled using MDF with 8 mm
Electricals: External Weatherproof Power Input Socket, Distribution Box with Isolator, Mini-Circuit Breakers, ELCB. PVC Insulated Cables in Conduits or Casing-and-Capping
Toilet/Bathroom: European Style WC with cistern , Health Faucet, Water Faucet, Towel Rod, Soap Dish, Wash basin, Mirror, Brush holders
Furniture: i. Bed: 190x90cm – 3nos. ii. Table 2nos
Manually operated Customized Boom barrier (13 m length,3"-2.5"-2" diameter ).Specifications:Mounting posts are made of 4 inch MS C channels and 13m booms are made by 3,2.5,2 inch MS Pipes with additional protection given by providing 2x1 inch square tubes.Supporting post is made of 4 inch Single C channel and Weight basket is made of 1x1/4 inch L channels with inside dimensions of 2x2 feet.Boom barrier is coated with two layers of epoxy primer paints and Red& White metal paints.Sign boards and reflective stickers are fixed on both side of the Boom barrier.RCC Footing Measurements:.65mx.65mx.80m M25 Concrete for Mounting Post and .30mx.30mx.30m M25 Concrete for Supporting Post.
Camera Mounting Cross bar with 5 inch * 7M vertical and 4 inch *13M horizonal posts connected by a T flange.Specifications:Poles are made of 5 inch diameter with medium gauge,7m tall GI post on both sides of the road ,fixed in ground with concrete footing.Cross bar is made of 4 inch dia with medium gauge GI Pipe,fixed at a height of 6m from ground on 7m tall vertical posts.Two layers of epoxy primer and paints will be applied.RCC Footing Measurements:.80mx.80mx1m M25 Concrete for Camera mounting cross bar footing.
Single phase KSEB Connection with One year bill Payment(Initial connection charge 15000/- and Two month Bill Amount 20000/-(Approximate)
Internet Connection with One year Bill Payment
Charges for Providing Water Connection from nearest Water Sources.(Includes Water pump,Pvc pipes and Plumbing accessories)
Split Inverter type AC 1 ton.Specifications;AI Dual inverter,AI Convertible 6 in 1 Cooling,Artificial Intelligence Cooling Mode, ADC Sensor ,4 Way Swing,HD Filter with Anti Virus Protection. Provides One year warrenty and two year service support
LED Flood Light 100W.Specification:240 volts,100 wattage,9000 lumen,White colour,Electric corded,IP65 Waterproof and IK07 Mechanical shock ratings,Elegant and Power saving and integrated design,no bulb replacements plus 70% light output maintenance to 30000 hours.
Wall mountable Fan.Specifications:Electric Spind Cabin 300mm Ultra High Speed 3 Blade,air delivery of 4800 CMM,Boasting high speeds of up to 2000rpm.Equipped with a powerful motor and aerodynamically desidned blades,this cabin fan delivers effective cooling.
LED Tube Light, 20W LED Cool Day Light Batten.Specifications:Better lumens and longer lamp life,High efficacy and lower power consumption,No UV or IR radiations as it does not contain mercury
2.5 sqmm PVC Insulated Wire
1.5 sqmm PVC Insulated Wire
5MP Varifocal camera(3.6 to12mm),1/2.8-in.5 MP Progressive scan CMOS Sensor,2592x1944 at 20 fps max resolution,3.6mm to 12mm motorized verifocal lens,true wide dynamic range(120dB) and 2D/3D noise reduction,Max IR Length 80m,Smart IR,IP67 Ingress protection,Dual power input,24VAC OR 12VDC
Outdoor CAT6 cable
1.5 sqmm 3core flexible wire
8 chanel NVR/4k,2 SATA HDD Slot Max 12TB 12 VDC
4 TB surveillance HDD
2.5 sqmm Armoured cable
25mm HDPE hose
6core OFC
4 U rack with PDU
32 inch LED monitor
CAT 6 indoor cable
2 KVA/24V,1760 Watts 2 battery system(24DC) UPS,DSC Based intelliPure Sinewave UPS, LED&LCD Display indications,PWM Controlled Multistage Charging,Smart overload sense,short circuit and over temperature protection ,With 200AH (2 nos) Battery
Media converters,PoE Switches,Network Switches,JB/Pannel boxes,RJ45 Jacks,IP67 JB,AC DB,Conduit and electrical fittings,Switch with socket /box,Trenching and all accessories required for the completion of the Project
Professional charges for Testing and Commissioning
EXCLUSIVE OF GST
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
5.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
MCB/ELCB/DB - L&T/LEGRAND/SCHNEIRDER or equivalent
Cables & wires - Finolex/KEI/POLYCAB/RPG/V-GUARD
Switches/Sockets/Regulators - SCHEIDER/ABB/HAVELS/LEGRAND or equivalent
Cable Glands & Sockets - REPUTED MAKE , Cosmos
Indicating Lamps - TEKINIC/RISHUB/STC, L&T, Schneider or equivalent
Ceiling/Exhaust fan: Havells, Orient, Usha, Crompton Greaves, Bajaj
KALLOOR ELECTRONICS AND LIGHTING PVT LTD
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .