Loading…
Loading…
Tender Value
₹20.8 L
EMD Value
₹24,600
Closing Date
16 Feb 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
Superintending Engineer PGVCL RAJKOT CITY CIRCLE
Construction of Lift at Rajkot City Division -1@ Old Power House Campus under Rajkot City Circle.
272314
RCC /TECH/E-TENDER/2025-26/149
Open
Civil Works - Others
Rajkot
12 documents required · 12 mandatory
₹1,475
SE, Rajkot City Circle office PGVCL
₹24,600
3 Feb 2026
3 Feb 2026
3 Feb 2026
16 Feb 2026
3 Feb 2026
Name of Work : Construction of Lift at Rajkot City Division -1 @ Old Power House
Campus under Rajkot City Circle
ITEM QTY PER RATE AMOUNT
Excavation for foundation upto 1.5 m depth including
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil 2.00 Cmt 210.42
Excavation for foundation up to 1.5M depth including
sorting out and stacking of useful materials and disposing of
the excavated stuff upto 50M. Lead. (B)Dense or hard soil. 2.00 Cmt 269.87
Excavation for foundation upto 1.5 m depth including
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(C)
Hard Murrum 2.00 Cmt 460.53
Excavation for foundation upto 1.5 m depth including
sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(D)
Soft rock not requiring Blasting 2.00 Cmt 552.75
Excavation for foundation upto 1.5 m depth including
5 sorting out and stacking of useful materials and
disposing off the excavated stuff upto 50 Meter lead.(E)
Hard rock 2.00 Cmt 1031.41
Excavation for foundation for depth from 1.5 m to 3.0 m
6 including sorting out and stacking of useful materials
and disposing off the excavated stuff upto 50 Meter
lead. (D) Soft rock not requiring Blasting 3.00 Cmt 576.18
Excavation for foundation for depth from 1.5 m to 3.0 m
7 including sorting out and stacking of useful materials
and disposing off the excavated stuff upto 50 Meter
lead.(E) Hard Rock 3.00 Cmt 1071.04
Providing and laying controlled cement concrete M.150 for
8 curing complete excluding cost of formwork and
reinforcement for reinforced concrete work in (A)
Foundations, footings,Base of columns and Mass concrete 1.00 Cmt 3952.22
Filling available excavated earth ( excluding rock ) in
9 trenches, plinth, sides of foundation etc. in layers not
exceeding 20 cm. in depth consolidating each deposited
layer by ramming and watering. 12.00 Cmt 136.11
Filling in foundation and plinth with murrum or selected soil
10 in layers of 20 Cm. thickness including watering ramming
and consolidating etc. complete. 1.00 Cmt 296.70
Providing and laying in position Ready Mixed M-250 grade
concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in
transit mixer for a lead up to 10 kms having continuous
agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying,
Including the cost of centering shuttering finishing and
reinforcement including cost of admixtures in recommended
proportions as per IS: 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge.
Without Fly Ash (Min cement level as per latest IS 456 shall
be maintained) (Cement level 450 kg )........... For
Foundations, footings, Base of columns and Mass
concrete 3.00 Cmt 6131.79
Providing and laying in position Ready Mixed M-250 grade
concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in
transit mixer for a lead up to 10 kms having continuous
agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of laying,
Including the cost of centering shuttering finishing and
reinforcement including cost of admixtures in recommended
proportions as per IS: 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge.
Without Fly Ash (Min cement level as per latest IS 456 shall
be maintained) (Cement level 450 kg ).......... For Walls,
from top of foundation at All Floor Level 32.00 Cmt 8716.64
Providing and laying in position Ready Mixed M-250 grade
concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in
transit mixer for a lead up to 10 kms having continuous
agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work including
13 pumping of R.M.C. from transit mixer to site of laying,
Including the cost of centering shuttering finishing and
reinforcement including cost of admixtures in recommended
proportions as per IS: 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength
and durability as per direction of the Engineer - in - charge.
Without Fly Ash (Min cement level as per latest IS 456 shall
be maintained) (Cement level 450 kg )..... for Slab at All
Floor Level 2.00 Cmt 7753.39
Providing TMT bar FE 500/500D reinforcement for R.C.C.
14 work including bending, binding and placing in position
complete_Ground Floor 1800.00 Kg 76.52
Providing TMT bar FE 500/500D reinforcement for R.C.C.
15 work including bending, binding and placing in position
complete_First Floor 800.00 Kg 77.61
Providing TMT bar FE 500/500D reinforcement for R.C.C.
16 work including bending, binding and placing in position
complete_Second Floor 800.00 Kg 78.70
Providing TMT bar FE 500/500D reinforcement for R.C.C.
17 work including bending, binding and placing in position
complete_Third Floor 600.00 Kg 79.79
Providing TMT bar FE 500/500D reinforcement for R.C.C.
18 work including bending, binding and placing in position
complete_Fourth Floor 800.00 Kg 81.97
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in foundation
and plinth in Cement Mortar 1:5. (1- Cement : 5 -fine
sand)_Fly Ash Bricks_Fourth Floor 6.00 Cmt 5845.55
Providing 10MM thick cement plaster in single coat on
Brick/concrete walls for interior plastering level finished
even and smooth in Cement Mortar 1:3 (1-Cement :3-
Sand)_Fourth Floor 8.00 Smt 269.82
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for interior
plasteringand finished even and smooth in (i) Cement
mortar 1:3 (1-cement:3-sand) _Ground Floor 42.00 Smt 187.11
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for interior
plasteringand finished even and smooth in (i) Cement
mortar 1:3 (1-cement:3-sand) _First Floor 27.00 Smt 212.59
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for interior
plasteringand finished even and smooth in (i) Cement
mortar 1:3 (1-cement:3-sand) _Second Floor 27.00 Smt 238.07
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for interior
plasteringand finished even and smooth in (i) Cement
mortar 1:3 (1-cement:3-sand) _Third Floor 17.00 Smt 263.55
Providing 15mm thick cement plaster in single coat on
Rough (Similar)side of single or half brick walls for interior
plasteringand finished even and smooth in (i) Cement
mortar 1:3 (1-cement:3-sand) _Fourth Floor 12.00 Smt 289.03
20mm thick sand faced cement plaster on walls upto height
26 10 metres above ground level consisting of 12mm thick
backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick
finishing coat of C.M. 1:1 (1-cement : 1-sand) etc. complete. 147.00 Smt 329.18
Providing and laying broken China Mosaic Flooring for
terrace using 12mm to 20mm broken pieces of glazed tiles to
be laid over cement mortar 1:3 to plain or slope and to be
tempered to bring mortar crème out upto surface using white
cement including rounding off junctions and extending them
up to 15cm along the wall, clearing with water and oxalic
acid etc. as directed by EIC. 6.00 Smt 771.98
Wall painting (two coats) with plastic emulsion paint of
approved brand and manufacture on undecorated wall
surface to give an even shade including throughly brushing
the surface free from mortar droppings and other foreign
matter and sand papered smooth.- For Wall 115.00 Smt 87.85
Wall painting (two coats) with plastic emulsion paint of
approved brand and manufacture on undecorated wall
surface to give an even shade including throughly brushing
the surface free from mortar droppings and other foreign
matter and sand papered smooth.- in ceiling 8.00 Smt 93.75
Applying two coats of birla (white cement based) or asian or
equivalent and two coats of primer of approved brand and
manufacture on new wall surface to give an even shade
including thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand papered smooth. 115.00 Smt 40.19
Applying One coat of primer of approved brand and
31 manufacture on new wall surface to give an even shade
including thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand papered smooth. 147.00 Smt 28.00
Finishing wall with weather proof exterior emulsion paint
APEX of Asian Paint on wall surface (two coats) to give an
32 required shape even shade after thorughly brushing the
surface to remove all dirt and remains of loose powdered
materials etc. complete 130.00 0.00 140.00
33 Lift/Elevator
(A) GENERAL DESCRIPTION OF LIFTS.
[1] GEAR LESS LIFT DRIVE (MRL) comprising of High
Starting torque Lift 3 phase 440 V A. C. Permanent Magnet
Synchronous motor of proper rating with high efficiency
shall be used.[2] Micro processor based / PLC, ACVVVF,
vector control drive with encoder feedback closed loop
system shall be used for lift car and door operation which
shall be full collective selective operation hall call demand
response, UP/DOWN hall stops, Main, Up/ Down
Contactor with overload and phase reversal relay and safety
[3] Car with M S platform with bracings of adequate size
and to sustain the impact load cabin + passenger with safety
factor of fire for steel and side panels of Stainless steel of
sheet of grade 304 duty. Car ceiling will be S.S. finishes
with aesthetic appearance with LED ceiling lights. Car
flooring shall be of anti skid PVC with choice of colour of
engineer in charge. Car doors shall be of stainless steel grade
304, hairline finish with centre opening / telescopic
automatic doors. Car panel will also be S.S. 304 finished
with emergency stop device, mechanical door safety device,
facility of auto/ attended mode. All car panel buttons and all
floor switches must be with brail language as per lift act.
[4] All landing doors must be fire rated for 2 hour shall be
fully automatic centre opening/ telescopic opening made of
hairline finish steel grade of 304 with key holes and infrared
curtains with Unlocking facility from outside
[5] Appropriate battery operated emergency light in the car
along with alarm switch shall be provided. Also, Emergency
Light & Fan should start immediately without any Time
Delay as soon as power fails.
[6] Digital scrolling indicator system for up-down arrow
along with floor position indicator shall be provided inside
the car and at all floors.
[7] Full height infra red curtain with multiple cross /
crossing light beams shall be provided.[8] Automatic Rescue
Device (ARD) shall be provided accordingly of passenger
capacity with Manual Rescue Operation ( Manual Cranking
[9] Audio visual indication in the lift car showing over
loading shall be provided such that doors kept open till
excess load is removed.
[10] Spring buffers/PU Buffers shall be provided.
[11] Car fan as per passenger capacity with automatic sleep
timer shall be provided.
[12] Voice annunciator with suitable music shall be
provided in lift car.
[13] Self diagnostics system for operational and safety
parameters shall be provided in control panel.
[14] Mechanical over speed governor with governor
calibration as per actual site parameters and submission of
calibration certificate submission, door key holes in the floor
doors, fireman switch shall be provided.
[15] Lift machine hoisting arrangement in the lift machine
room and monkey ladder for lift pit should be provided by
the lift agency, along with the other steel structure works,
foundations for the machine etc…
[16] In the hoist way fascia plate shall be provided without
any extra cost, where ever required as / if directed by
engineer in charge.
[17] Permanent wiring with necessary safety devices like
RCCB in all circuit, Over Voltage Under Voltage protection
and THD eliminator in circuit for lift machine room and lift
well with proper numbers of light points, with fixtures,
exhaust fan and plug points shall be provided by the agency.
Only 3 phase Power Supply shall be made available by
department in lift machine room. Necessary Earthing as per
Lift Act/Rules shall be arranged by Lift Agency.
[18] Any civil/ electrical works for additional and alteration
in lift shaft and machine room related to erection of lift shall
be made by lift agency without any extra cost.
(granite/marble fixing around all landing door openings are
not in lift agency’s scope.)
[19] Agency has to provide all working drawings and
documents and liaison services for obtaining all necessary
permission from lift inspector and other authorities.
[20] acrylic transparent licence/display A4 size holder in lift
[20A] As per statutory requirement of Govt. Of Gujarat lift
& escalator act 2000, lift agency has to provide
1. Car top safety barricade
2. Push & talk communication system.
3. Fireman's switch operation at Ground Floor.
4.carrying out third party lift inspection during/after lift
erection and provide report by third party authorized by
concern licensing authority 5.agency has to provide third
party insurance upto completion of free maintenance period
and submit the document for the same.
[21] Car Panel Operating Buttons with floor position
indicator/buttons must be of Auto Glow type clearly visible
when view from inside cabin.
[22] For Physically Handicapped person Full Length
Handrails of hairline finish steel grade of 304 should be
provided at appropriate height on the Rear & Side Wall
Panels in Lift Car.
Supplying, Erecting, Testing & Commissioning the
passenger / stretcher lift having following main features:
Passengers, Ground plus 2 upper floors with Rated Speed
of 1.0 m/sec. (B) With General Specification attached
herewith. Cat.III 1.00 Nos 1223040.00
(B) Bidder's Offer _____% Above/Below of (A)
(C) Grand Total (C = A + B)
(C) Grand Total (C = A + B)
(D) Goods & Service Tax ( D = C x GST in % Prevailing or Applicable )
(E) Grand Total Including GST ( E = C + D )
(E) Grand Total Including GST ( E = C + D )
Final Offer with GST In Word:
I / WE HERE BY AGREE TO CARRY OUT ABOVE SAID WORK AT______%
(A) WITHOUT THE
RS.(IN COST MENTIONED AS ABOVE AND THUS THE AMOUNT
(B)WITH GST RS.(IN FIGURE)______________________.
Signature of contractor with seal CHIEF ENGINEER (MATERIAL),
PGVCL, CORPORATE OFFICE,
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
01 Tender Documents.pdf
02 Schedule-B of Lift RCD-1.pdf
Download all tender documents and submit your bid