Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.2 LAccepted-AOC H NO 312 B D C OPP PLOT NO 23 TRANSPORT AREA SECTOR 26 CHANDIGARH | CHANDIGARH | CHANDIGARH | CHANDIGARH | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹32.4 L+₹5.2 L (19.0%)Rejected-AOC | L2 | Rejected-AOC Other Than Lowest Bidder | |
| 3 | L3₹33.1 L+₹5.9 L (21.6%)Rejected-AOC | L3 | Rejected-AOC Other Than Lowest Bidder | |
| 4 | L4₹35.7 L+₹8.5 L (31.1%)Rejected-AOC HM 324 PHASE IX SAS NAGAR MOHALI PB | L4 | Rejected-AOC Other Than Lowest Bidder | |
| 5 | L5₹38.5 L+₹11.3 L (41.6%)Rejected-AOC 411 STREET NO 4 PANCHVATI NAGAR BATHINDA 151001 | BATHINDA | PUNJAB | 151001 | L5 | Rejected-AOC Other Than Lowest Bidder |
Tender Value
₹43.2 L
EMD Value
₹86,400
Closing Date
15 Oct 2024, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N Area Pin-160003
SPL REPAIR TO ROOF TREATMENT IN ALL OTM BLDG NO P-1/1, P-1/2 , P-1/3 , P-10/1, P-10/2 AND P-10/3 AT K AREA UNDER GE CHANDIGARH
2024_MES_674995_1
GE/CHD-59/2024-25
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
Class D category a(i) for contractor enlisted in MES
7 documents required · 7 mandatory
₹500
GE Chandigarh
₹86,400
Yes
13 Dec 2024
18 Sept 2024
17 Oct 2024
18 Sept 2024
15 Oct 2024
3 Oct 2024
18 Sept 2024 - 24 Sept 2024
Amount
Taking up or down steel tubing 15 mm bore and connections, including cleaning for complete all as specified and directed.
Taking up or down steel tubing 20 mm bore and connections, including cleaning for complete all as specified and directed.
S&F tubes 15 mm, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including clamps and screws fixed on rawal plugs Complete all as specified.
S&F tubes 20 mm, `medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including clamps and screws fixed on rawal plugs Completeall as specified.
Re-fixing only tubes, any grade, to walls and ceilings or laying in floors 15 mm, `medium grade' galvanised, with all fitting and fixed clamps and screws fixed on rawal plugs Complete all as specified.
Re-fixing only tubes, any grade, to walls and ceilings or laying in floors 20 mm, `medium grade' galvanised, with all fitting and fixed clamps and screws fixed on rawal plugs complete all as specified.
Disconnecting existing tanks of capacity 500 ltr to1000ltr setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified.
Dismantling water tanks of capacity exc. 500 but not exc1000 litres complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks of 1000 litre capacity (cylindrical vertical with closed top triple layer) hoisted and fixed in repair position all as specified in SSR Part-I nd including tank nipple etc complete all as specified and directed.
S&F for GI tank nipple cast iron 20mm dai suitable for HDPE water tank (Minimum weight 15 mm-38gms/20mm-45gms /25mm- 65gms)specified and directed.
S&F for GI tank nipple cast iron 15mm dai suitable for HDPE water tank (Minimum weight 15 mm-38gms/20mm-45gms /25mm- 65gms)specified and directed.
M&L for 20mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Minimum weight 15mm-142gms/ 2 0 m m - 2 1 0 g m s . / 25mm-455gms/ 40mm - 690 gms)complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 15 mm bore dia complete all as specified and directed.
S&F in repair Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed for 20 mm bore dia complete all as specified and directed.
Dismantling of 110mm/75mmPVC (SWR) Pipes of any size and description fixed in wall , jointed in cement mortar and taking out of trenches, if required complete all as specified and directed.
S&F for in repair 110mm dia PVC rain water pipe pressure rating not less than 6 Kg/SQ Cm, ISI Marked fixed to wall set in cement mortar with and including MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc complete all as specified and directed.
S&F 110 mm PVC (SWR) pipes bends any radius fixed in repair complete all as specified and directed.
Demolition of RCC tank or stone/boulders masonary,bricks etc, built in Cement mortar or cement lime mortar including all quoins,arches,pillers etc but excluding ashlar facing etc including removing to out of MOD land complete all as specified.
Demolition of Brick tiles or terracing tiles, single layer on roofs etc complete all as specified and directed
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof)
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed
M&L for cleaning the surface and made free of dirt, foreign particle, laitance followed by grinding all protrusions to make surface modulated. Thereafter, inspection for crack on the surface caused by thermal expansion contraction. Cutting the grooves with suitable cutter machine in "v" groove filled with repair mortar/micro concrete/General purpose grout as recommended proportionally as per recommendation of manufacture. supplying and applying high performance Hybrid Polyurea elastomeric waterproofing coating cold applied of spray applied liquid membrane with an elongation of 500-600% and tensile strength of 11-13N/sqm as per ASTM D 2370, crack bridging ability of 3.5mm as per ASNZ 4548, shore A hardness of Min. 60 as per ASTM D 2240 having. The system includes final base preparation, epoxy primer application of 1:1 (Resin: Hardener) with 100% water dilution and application of hybrid polyurea polyurethane in two coats in 6Hrs intervalat a total minimum consumption of 1.8kg per sqm etc. The application should be done by company's authorized applicator. Graco sprayer by a company authorized applicator. Company back warranty of 5year's is to be given by company. High Performance Hybrid Polyurea elastomeric waterproofing coating of Smartcare Ultron. Resin is one of the component of Ultron primer, which is two component water based epoxy system, it is classified as SR-B2, 0 according to EN 13813 having properties like color of Pale yellow, viscosity 900mpa.s, density 1.15kg/l and adhesion of >3N/sqm. Hardener is one of the component of PU Magnum Primer, which is a two component epoxy system, it is classified as SR-B2, 0 according to EN 13813, having properties like color of pale yellow, viscosity 37000mpa.s, density 1.08Kg/l and adhesion of 3N/Sqm complete all as specified and directed. Make :- Asian , Berger, Dulux or Equivalent as approved by GE.
M&L for Brushing neat cement slurry with 3.0 kg of cement per sq.m, complete all as specified and directed.
M&L for providing cement concrete PCC 1:2:4( Type B-1) using 20 mm graded aggregate as in fillets at corners specialy provided in roof curb of fill the depresion and mantain etc semelar work complete all as specified and directed.
M&L nominal mix cement concrete 1: 2:4 (20 mm Graded agg) type B-1 as in padding in roof rough finish complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified.
M&L Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6) complete all as specified.
Repairing the edges of concrete chajjas, facias, slabs, columns ,beams (Height upto 2nd floor roof) & the like by providing PCC (1:2:4) type B-0 including all necessary form work and/or provision of rendering 15 mm thick (average thickness) in cement mortar (1:3), after applying a coat of cement slurry @ 3 kg/ Sq. m of surface, finished even and fair, surface area not exceeding 450 mm wide, in patches including two coat of cement base paint over a coat of primer ,including taking down swoolen/damaged plaster or concrete complete all as specified.
Supply only water proofing compound ISI marked complete all as specified.
S&F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed .
M&L for preparing new untreated steel or iron surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer, all as specified and directed by Engr-in-Charge.
M&L for rendering 15 mm thick cement plaster on brick work or concrete surfaces in cement mortar (1:4) finished fair complete all as specified and directed.
jaswant singh (BID ID -3139888)
pankaj and company (BID ID -3132011)
M/S MATLOOB AHMED (BID ID -3132816)
SHRI GANESH CONSTRUCTION CO. (BID ID -3139459)
M/s Super Trading Corporation (BID ID -3139400)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .