| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.7 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹5.8 L+₹9,747.96 (1.71%)Accepted-Finance | 2 | Accepted-Finance L2 | |
| 3 | 3₹6.1 L+₹41,211.78 (7.24%)Accepted-Finance | 3 | Accepted-Finance L3 |
| Sl No | Description | Qty | Unit | NITISH SHARMA L2 | Rajat Soni L1 | amandeep kalia govt contractor L3 |
|---|---|---|---|---|---|---|
| 1.00Tile Re-terracing on roof for Officer & Sub ordinate rest house, and work shop building | ||||||
| 1.01 | Dismantling of floor tiles at any floor of the
building, laid in cement mortar including
dismantling of cement concrete base and
disposal of malba at a suitable place within a
distance of 100 Mtrs of the complex complete in
all respect (Ref Pb CSR 2020- 30.95 ) L/R | 436.42 | Sqm | 114 ₹49,751.88 | 113.5 ₹49,533.67 Lowest | 120 ₹52,370.4 |
| 1.02 | Waterproofing treatment of RCC structures ( after making the surface clean, dry & free from all internal voids or honey combs ), with Zycosil
/ equivalent water proofing Solution (1 litre of
Zycosil / equivalent & 20 litres of potable water
stirred first &2 litres of Zycoprime / equivalent
added and stirred (total 23 litres)) using two coats till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls.(Ref Pb CSR 2020- 13.88 ) T/R | 436.42 | Sqm | 255 ₹1,11,287.1 | 248.1 ₹1,08,275.8 Lowest | 270 ₹1,17,833.4 |
| 1.03 | Supply & Fixing Fiber Glass Coated Mesh with
thickness of 45 Gsm for the waterproofing of roof terraces, bathrooms , Water tanks, etc. The
surface to be levelled, finished, made smooth
before fixing of Fiber Glass Mesh,complete in all
respect as per manufactures specification and as
per directions of Engineer-in-Charge.(Ref Pb CSR 2020- 13.90 ) T/R | 436.42 | Sqm | 125 ₹54,552.5 Lowest | 125 ₹54,552.5 Lowest | 140 ₹61,098.8 |
| 1.04 | Tile terracing laid dry over roof consisitng of one
layer of tiles 22.86x11.43x3.83 including grouting
with cement sand mortar 1:4 top surface to be left clean after wire brushing (Ref Pb CSR 2020- 13.17) T/R | 432.1 | Sqm | 410 ₹1,77,161 | 407.5 ₹1,76,080.75 Lowest | 430 ₹1,85,803 |
| 1.05 | Cement concrete 1:2:4 gola 10cm x 10cm
concave quadrant along junction of roofs with
parapet wall finished smooth, where specially
specified. (Ref Pb CSR 2020- 13.55) T/R | 202.1 | Mtr | 69 ₹13,944.9 | 67 ₹13,540.7 Lowest | 80 ₹16,168 |
| 1.06 | Top Khurra 0.6mx0.6m for rain water pipe in
25 mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 (Ref Pb CSR 2020- 13.45) T/R | 12 | Nos | 101 ₹1,212 | 99 ₹1,188 Lowest | 115 ₹1,380 |
| 1.07 | Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes single socketed
(working pressure 4kgf /cm²) conforming to IS:
4985, including fixing with MS clamps. U-PVCpipes (working pressure 4 kgf. / sqcm)
pipe 110 mm dia. (Ref Pb CSR 2020- 13.74 a (i)) T/R | 30 | Mtr | 266 ₹7,980 | 264 ₹7,920 Lowest | 280 ₹8,400 |
| 1.08 | Providing and fixing 110 mm dia.U.P.V.C bend
for Rainwater pipe as per IS:14735 including
jointing complete as per specification sand to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend (Ref Pb CSR 2020- 13.75a) T/R | 6 | Nos | 143 ₹858 | 142 ₹852 Lowest | 150 ₹900 |
| 1.09 | Providing and fixing 110 mm dia. U.P.V.C
Coupling/Sockete for Rain water pipe as per
IS:14735 including jointing complete as per
specifications and to the entire satisfaction of
Engineer- in- charge.UPVC 110 mm Coupling /Sockets (Ref Pb CSR 2020- 13.76a) T/R | 6 | Nos | 90 ₹540 | 87 ₹522 Lowest | 90 ₹540 |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
17 Feb 2026, 3:00 pmClosed
SR XEN BBMB Jagadhri
Sr XEN O and M Division BBMB Jagadhri
Renewal and Replacement of roof by ReTerracing of tiles and waterproofing treatment R and R of Sanitary fixtures on various Non Residential buildings at 220 KV GSS BBMB Jagadhri
2025_BBMB_260348_1
ENIT 07/2025-26 Dated 16.01.2026
Open Tender
Civil Works
Works
45 days
BBMB Jagadhri
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹6,000
Yes
26 Feb 2026
17 Jan 2026
19 Feb 2026
17 Jan 2026
17 Feb 2026
17 Jan 2026
17 Jan 2026 - 17 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Tile Re-terracing on roof for Officer & Sub ordinate rest house, and work shop building | |||||
| 1.01 | Dismantling of floor tiles at any floor of the
building, laid in cement mortar including
dismantling of cement concrete base and
disposal of malba at a suitable place within a
distance of 100 Mtrs of the complex complete in
all respect (Ref Pb CSR 2020- 30.95 ) L/R | - | Sqm | 113.77 | - |
| 1.02 | Waterproofing treatment of RCC structures ( after making the surface clean, dry & free from all internal voids or honey combs ), with Zycosil
/ equivalent water proofing Solution (1 litre of
Zycosil / equivalent & 20 litres of potable water
stirred first &2 litres of Zycoprime / equivalent
added and stirred (total 23 litres)) using two coats till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls.(Ref Pb CSR 2020- 13.88 ) T/R | - | Sqm | 248.62 | - |
| 1.03 | Supply & Fixing Fiber Glass Coated Mesh with
thickness of 45 Gsm for the waterproofing of roof terraces, bathrooms , Water tanks, etc. The
surface to be levelled, finished, made smooth
before fixing of Fiber Glass Mesh,complete in all
respect as per manufactures specification and as
per directions of Engineer-in-Charge.(Ref Pb CSR 2020- 13.90 ) T/R | - | Sqm | 125.36 | - |
| 1.04 | Tile terracing laid dry over roof consisitng of one
layer of tiles 22.86x11.43x3.83 including grouting
with cement sand mortar 1:4 top surface to be left clean after wire brushing (Ref Pb CSR 2020- 13.17) T/R | - | Sqm | 407.7 | - |
| 1.05 | Cement concrete 1:2:4 gola 10cm x 10cm
concave quadrant along junction of roofs with
parapet wall finished smooth, where specially
specified. (Ref Pb CSR 2020- 13.55) T/R | 1 | Mtr | 68.47 | ₹68.4 |
| 1.06 | Top Khurra 0.6mx0.6m for rain water pipe in
25 mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 (Ref Pb CSR 2020- 13.45) T/R | - | Nos | 100.08 | - |
| 1.07 | Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes single socketed
(working pressure 4kgf /cm²) conforming to IS:
4985, including fixing with MS clamps. U-PVCpipes (working pressure 4 kgf. / sqcm)
pipe 110 mm dia. (Ref Pb CSR 2020- 13.74 a (i)) T/R | - | Mtr | 265.48 | - |
| 1.08 | Providing and fixing 110 mm dia.U.P.V.C bend
for Rainwater pipe as per IS:14735 including
jointing complete as per specification sand to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend (Ref Pb CSR 2020- 13.75a) T/R | - | Nos | 142.22 | - |
| 1.09 | Providing and fixing 110 mm dia. U.P.V.C
Coupling/Sockete for Rain water pipe as per
IS:14735 including jointing complete as per
specifications and to the entire satisfaction of
Engineer- in- charge.UPVC 110 mm Coupling /Sockets (Ref Pb CSR 2020- 13.76a) T/R | - | Nos | 88.49 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
Tendernotice_2.pdf
PDF • 0.37 MB
BOQ_301096.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .