| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.7 LAccepted-Finance | ₹5.7 L | 1 | Accepted-Finance L1 |
| 2 | 2₹5.8 LAccepted-Finance | ₹5.8 L | 2 | Accepted-Finance L2 |
| 3 | 3₹6.1 LAccepted-Finance | ₹6.1 L | 3 | Accepted-Finance L3 |
| Sl No | Description | Qty | Unit | NITISH SHARMA L2 | Rajat Soni L1 | amandeep kalia govt contractor L3 |
|---|---|---|---|---|---|---|
| 1.00Tile Re-terracing on roof for Officer & Sub ordinate rest house, and work shop building | ||||||
| 1.01 | Dismantling of floor tiles at any floor of the
building, laid in cement mortar including
dismantling of cement concrete base and
disposal of malba at a suitable place within a
distance of 100 Mtrs of the complex complete in
all respect (Ref Pb CSR 2020- 30.95 ) L/R | 436.42 | Sqm | 114 ₹49,751.88 | 113.5 ₹49,533.67 | 120 ₹52,370.40 |
| 1.02 | Waterproofing treatment of RCC structures ( after making the surface clean, dry & free from all internal voids or honey combs ), with Zycosil
/ equivalent water proofing Solution (1 litre of
Zycosil / equivalent & 20 litres of potable water
stirred first &2 litres of Zycoprime / equivalent
added and stirred (total 23 litres)) using two coats till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls.(Ref Pb CSR 2020- 13.88 ) T/R | 436.42 | Sqm | 255 ₹1.1 L | 248.1 ₹1.1 L | 270 ₹1.2 L |
| 1.03 | Supply & Fixing Fiber Glass Coated Mesh with
thickness of 45 Gsm for the waterproofing of roof terraces, bathrooms , Water tanks, etc. The
surface to be levelled, finished, made smooth
before fixing of Fiber Glass Mesh,complete in all
respect as per manufactures specification and as
per directions of Engineer-in-Charge.(Ref Pb CSR 2020- 13.90 ) T/R | 436.42 | Sqm | 125 ₹54,552.50 | 125 ₹54,552.50 | 140 ₹61,098.80 |
| 1.04 | Tile terracing laid dry over roof consisitng of one
layer of tiles 22.86x11.43x3.83 including grouting
with cement sand mortar 1:4 top surface to be left clean after wire brushing (Ref Pb CSR 2020- 13.17) T/R | 432.1 | Sqm | 410 ₹1.8 L | 407.5 ₹1.8 L | 430 ₹1.9 L |
| 1.05 | Cement concrete 1:2:4 gola 10cm x 10cm
concave quadrant along junction of roofs with
parapet wall finished smooth, where specially
specified. (Ref Pb CSR 2020- 13.55) T/R | 202.1 | Mtr | 69 ₹13,944.90 | 67 ₹13,540.70 | 80 ₹16,168 |
| 1.06 | Top Khurra 0.6mx0.6m for rain water pipe in
25 mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 (Ref Pb CSR 2020- 13.45) T/R | 12 | Nos | 101 ₹1,212 | 99 ₹1,188 | 115 ₹1,380 |
| 1.07 | Providing and fixing on wall face unplasticised
Rigid PVC rain water pipes single socketed
(working pressure 4kgf /cm²) conforming to IS:
4985, including fixing with MS clamps. U-PVCpipes (working pressure 4 kgf. / sqcm)
pipe 110 mm dia. (Ref Pb CSR 2020- 13.74 a (i)) T/R | 30 | Mtr | 266 ₹7,980 | 264 ₹7,920 | 280 ₹8,400 |
| 1.08 | Providing and fixing 110 mm dia.U.P.V.C bend
for Rainwater pipe as per IS:14735 including
jointing complete as per specification sand to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend (Ref Pb CSR 2020- 13.75a) T/R | 6 | Nos | 143 ₹858 | 142 ₹852 | 150 ₹900 |
| 1.09 | Providing and fixing 110 mm dia. U.P.V.C
Coupling/Sockete for Rain water pipe as per
IS:14735 including jointing complete as per
specifications and to the entire satisfaction of
Engineer- in- charge.UPVC 110 mm Coupling /Sockets (Ref Pb CSR 2020- 13.76a) T/R | 6 | Nos | 90 ₹540 | 87 ₹522 | 90 ₹540 |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
17 Feb 2026, 3:00 pmClosed
SR XEN BBMB Jagadhri
Sr XEN O and M Division BBMB Jagadhri
Renewal and Replacement of roof by ReTerracing of tiles and waterproofing treatment R and R of Sanitary fixtures on various Non Residential buildings at 220 KV GSS BBMB Jagadhri
2025_BBMB_260348_1
ENIT 07/2025-26 Dated 16.01.2026
Open Tender
Civil Works
45 days
BBMB Jagadhri
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹6,000
Yes
26 Feb 2026
17 Jan 2026
19 Feb 2026
17 Jan 2026
17 Feb 2026
17 Jan 2026
17 Jan 2026 - 17 Feb 2026
Tile Re-terracing on roof for Officer & Sub ordinate rest house, and work shop building
Dismantling of floor tiles at any floor of the building, laid in cement mortar including dismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect (Ref Pb CSR 2020- 30.95 ) L/R
Waterproofing treatment of RCC structures ( after making the surface clean, dry & free from all internal voids or honey combs ), with Zycosil / equivalent water proofing Solution (1 litre of Zycosil / equivalent & 20 litres of potable water stirred first &2 litres of Zycoprime / equivalent added and stirred (total 23 litres)) using two coats till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls.(Ref Pb CSR 2020- 13.88 ) T/R
Supply & Fixing Fiber Glass Coated Mesh with thickness of 45 Gsm for the waterproofing of roof terraces, bathrooms , Water tanks, etc. The surface to be levelled, finished, made smooth before fixing of Fiber Glass Mesh,complete in all respect as per manufactures specification and as per directions of Engineer-in-Charge.(Ref Pb CSR 2020- 13.90 ) T/R
Tile terracing laid dry over roof consisitng of one layer of tiles 22.86x11.43x3.83 including grouting with cement sand mortar 1:4 top surface to be left clean after wire brushing (Ref Pb CSR 2020- 13.17) T/R
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (Ref Pb CSR 2020- 13.55) T/R
Top Khurra 0.6mx0.6m for rain water pipe in 25 mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 (Ref Pb CSR 2020- 13.45) T/R
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4kgf /cm²) conforming to IS: 4985, including fixing with MS clamps. U-PVCpipes (working pressure 4 kgf. / sqcm) pipe 110 mm dia. (Ref Pb CSR 2020- 13.74 a (i)) T/R
Providing and fixing 110 mm dia.U.P.V.C bend for Rainwater pipe as per IS:14735 including jointing complete as per specification sand to the entire satisfaction of Engineer- in- charge. UPVC 110 mm bend (Ref Pb CSR 2020- 13.75a) T/R
Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm Coupling /Sockets (Ref Pb CSR 2020- 13.76a) T/R
12.5 mm thick cement plaster 1:4 (Ref Pb CSR 2020- 15.9) T/R
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. (Ref Pb CSR 2020- 11.4(i) T/R
Officer Rest house Room No 1 & 2 Toilet
Dismantling Sanitary fixtures such as Eurpoean/Indian/Orissa W.C., PVC / China ware cistern, Wash Hand Basin, Urinal Pot, Sinks and CP Fittings and disposal of dismantled material within a distance of 100 Mtr. complete in all respect as required by Engineer-in-Charge. (Ref Pb CSR 2020- 30.88 (a ) L/R Eurpoean/Indian/Orissa W.C.,
Wash Hand Basin / Urinal Pot (Ref 30.88 (c)
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. Size 630mmx 500mm (above counter oval) (Ref Pb CSR 2020- 30.32viii ) T/R
Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.Chinaware extended wall mounted E W.C. with matching chinaware cistern and seat cover complete in all respect. (Ref Pb CSR 2020- 30.3b ) T/R
Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. C.P. brass Bib cock long nose/ long body foam flow without flange (Ref Pb CSR 2020- 30.65A(i) ) T/R
Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P.brass 15mm stop cock Male and female end (Ref Pb CSR 2020- 30.66-a ) T/R
Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect .PVC tube connection of size 15 mm x 600 mm with PTMT nut (Ref Pb CSR 2020- 30.72h ) T/R
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B-75mm o/d SWR UPVC pipe lines laid complete (Ref Pb CSR 2020- 30.74iii B (d)) T/R
Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) BClass including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete.15mm i/d (Ref Pb CSR 2020- 28.35a ) T/R
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
Tendernotice_2.pdf
PDF • 0.37 MB
BOQ_301096.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid