Construction of Art and Craft Room, Computer Room, Library Room and Science Room at High School Aripal.(S.No 721,722,723,725)
2025_PWDJK_296280_1
131/EEA/RNB of 2025-26/7096-7106 Dated 25-11-2025
Open Tender
Civil Works
Percentage
120 days
tral
as per nit
4 documents required · 4 mandatory
₹1,600
Executive Engineer rnb division Awantipora
₹1.6 L
25 Nov 2025
25 Nov 2025
12 Dec 2025
25 Nov 2025
11 Dec 2025
26 Nov 2025
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: all kinds of soils
Providing & Laying of stone soling (dully hand packed) including watering dressing and ramming with all carriages loading un-loading and stacking etc complete
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
P/L in position specified grade of reinforced cement cencrete excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. 1:1.5:3 graded stone agg. 20mm nominal size
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (TMT bars of grade Fe-500D or more.)
Supplying and fixing of following sizes of medium class PVC condult( Anchor/Ravindra/Eq. make)along with accessorles in surface/recess Including cutting the wall and making good the same in case of recessed condult as required, with cement plaster, wall putty, paint,complete.
Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position Imported wood
Providing & fixing panelled or panelled & glazed shutters for doors & windows and clerestory windows including ISI marked black enamelled M.S Butt hingeswith necessary screws excluding panelling Imported wood 30mm thick.
Brick work with FPS bricks of class designation 75 in super structure upto floor V level cement mortar 1:6 (1 cement, 6 coarse sand)
Providing & fixing 3.5 mm Thick Glass panes i/c necessary beading and nails complete as directed.
12mm Cement Plaster of mix 1:6(1 cement:6 coarse sand)
6 mm cement plaster to ceiling of mix 1:3(1 cement: 3 fine sand)
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick.
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws 30 mm thick.
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work. Including applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Providing & filing of stone dust including watering and ramming incl. all carriages complete
Providing & fixing of 40x5mm flat iron hold fast 40cm long including fixing to frameswith 10mm dia bolts nuts & wooden plugs and embedding in cement concrete block 30x10x5cm 1:3:6mix (1cement:3coarse sand:6 graded st agg)20mm nominal size.
Filling available excavated earth (excl. rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
Centring and shuttering incld. Strutting, proping etc & removal of form work for Founadtions, footings, bases of columns for mass concrete.
Centring and shuttering incld. Strutting, proping etc & removal of form work for suspended floors, roofs, landings, balconies & access plateform
Centring and shuttering incld. Strutting, proping etc & removal of form work for Lintel, Beams etc
Centring and shuttering incld. Strutting, proping etc & removal of form work for colums, pillars, piers, abts, posts and strats
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. i/c soffits / eaves board Welded
Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing ridges of hips of width 60cm overall width plain GS sheets fixed with polymer coated J or L hooks bolts & nuts 8mm dia GI limpet & bitumen washers complete 0.50mm thick with zinc coating not less than 275g/sqm
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm
Providing and Fixing of L Drop of Standard make i/c Locking system complete
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Provding & fixing 04 layer 18 gauge (304)plain stainless steel railing of approved make i/c master pillar and boster on alternate steps or equlant i/c welding, polishing as per directions of engineer incharge complete
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing 75 mm dia PVC B Class
PVC collar 75 mm
P/F of PVC floor trap with Jali
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-incharge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc
PN-16 pipe, 25mm OD(SDR-7.4)
External work including trenching, refilling etc PN-16 pipe , 32mm OD (SDR-7.4)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) overand including priming coat with water thinnable cement primerork
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40mm C.P. brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the walls wherever required : Size 600x450x200 mm
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
P/F man hole 1' x 1' i/c brick work , plaster, polishing complete as per directions of EIC incl cover with frame
Dry rubble masonry with hard stone iusing quarry stone including all carriages complete.
Providing and fixing uplasticized PVC connection pipe with brass unions 45 cm length 20 mm nominal bore
Carriage of materails By Mech.Transport, from source to site of work
Stone agg. for an avg lead of 15 km
Sand from for an avg lead of 20 km
Bricks from for an avg lead of 35 km
ELECTRIFICATION
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor (Havell life guard/Polycab/ Finolex/ Anchor/eq. standard make as desired by engineer Incharge) single core cable in surface / recessed medium class PVC condult, with modular switch (Anchor roma plus/Legrand Mylinc /SSK NV/schneider Livia /ABB Tvisha make.), modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable etc, as required.
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without Independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor (Polycab Green/Fenolex/ Salzer/RR/eq. standard make as desired by engineer incharge) single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC Insulated copper conductor single core cable etc. as required.
Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire FRLS PVC insulated copper conductor (Havell life guard/Polycab/ Finolex/ Anchor/eq. standard make as desired by engineer Incharge) single core cable in surface/recessed medium class PVC. condult
Supplying and fixing sultable size Gl box with modular plate and cover in front on surface or in recess, Including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, modular plate, suitable Gl box, connections etc. as required. Modular Switch & Socket:- (Anchor roma plus/Legrand Mylinc/SSK NV/schneider Lelva /ABB Tvisha make make.)
Wiring for lighting circults/6-10 amp power plugwith 2X2.5 sq. mm FRLS PVC Insulated copper conductor (Havell life guard/Polycab/Finolex/Anchor/eq. standard make as desired by engineer Incharge ) single core cable in surface/recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size Gl box with modular plate and cover In front on surface or In recess, Including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential büildings). Modular Switch & Socket:- (Anchor roma plus/Legrand Mylinc/SSK NV/schneider Livia /ABB Tvisha make.)
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, Including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc., as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC Insulated copper conductor (Havell Ilfe guard/Polycab/ Finolex/ Anchor/eq. standard make as desired by engineer Incharge), single core cable In surface/ recessed medium class PVC conduit as required
c) space for 12 way MCB's
(b)2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Sub Head-2-Fixtures and Fittings
Supply installation testing and commissioning of 15 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 THD<10%, CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V.The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The Job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which Includes replacement of fixtures of crompton/Helonix/Havell make /sample to be approved before Installation..
S/F testing and comm. of 20 Watt 4 ft. wall mounted LED bätten with powdered coated aluminium housing & integrated electronic driver with THD<10%. (commercial series) Helonix/ wipro/ Havell make/ eq. standard make as directed by engineer Incharge.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, decorative ceilin
g fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos, canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and Including iron hook complete. USHA/orient/Crompton make ( sample to be approved before installation)
Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc/ABB Tivsha/schneider Livia/Havell Coral make.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, (Havell/ legrand/ Shinider/SSK make) 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, Interconnections, powder painted Including earthing etc.as required. (But without MCB/RCCB/Isolator)
2+14 way, Double door
(a) 2 X6 sq. mm +1 X 6 sq. mm earth wire
b) 40-63amp DP MCB
5/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ ABD equivalent make as directed by engineer Incharge.
Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode, 80mm dia. connecting the plate with main control board by8- 10 SWG G.I wire with 1/2" dia. Full thread brass nut and bolt and washers. Refiling of pit with chemical compound.
S/L, testing and commissioning of PVC XLPE Insulated alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer Incharge and making end termination with brass compression gland and aluminium lugs of required size.
c)25 sq.mm 2 core
Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel, floor/wall mounted, vermin and dust proof, Indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears,, Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required. As per approved design, size may vary as per site requirement)
Normal INCOMING:
Providing and fixing of following protection equipments and other allied accessories Including connections, inter connections, with suitable size of PVC Insulated copper conductor cable including earthing etc. as required.
b) 2 No. of Aluminium Bus Bar of 200 Amp.
a)125A 2P MCCB 25 KA Including spreader links including spreader links, Icu=ics=100% (Adjustable thermal and Adjustable magnetic release) Legrand/Shinider/Semlens/ABB make.
OUTGOING:
c) 40-63amp DP MCB
c) Digital meters and phase Indicators -1 set.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
BOQ_959912.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .