Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC M/S R R AND COMPANY IS THE LOWEST BIDDER, HENCE ACCEPTED | |
| 2 | L2₹31.7 L+₹68,025 (2.19%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹36.5 L+₹5.5 L (17.7%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹32.1 L
EMD Value
₹64,200
Closing Date
21 Dec 2023, 6:00 pmClosed
Garrison Engineer Kota
Dadwara Complex, Military Station Kota - 324002
SPECIAL REPAIR IN OR BATHROOM AND TOILETS OF BLDG NO T-03 (TOTAL-21 NOS) AND PROVN OF PARKING SHED INFRONT OF BLDG NO P-03 AND NEAR BLDG NO P-102 IN NORTHERN SECTOR AT MIL STN KOTA
2023_MES_603972_2
8734/E8
Open Tender
Civil Works
Item Rate
183 days
KOTA
Contractor shall be enlisted with MES in Class D and above and category a(i) subject to satisfactory remarks wrt performance in respect of works in hand as reflected in Work Load Return (WLR) or any other report circulated by competent engineer a
8 documents required · 8 mandatory
₹500
GE KOTA
₹64,200
Yes
30 Jan 2024
1 Dec 2023
23 Dec 2023
1 Dec 2023
21 Dec 2023
9 Dec 2023
1 Dec 2023 - 6 Dec 2023
Amount
Demolition/Dismantling of existing roof treatment, any type from RCC roof slab including lime concrete/PCC padding over roof, removing layer of bitumen under lime concrete/PCC padding, cement mortar, felt etc and cleaning the surface by hacking to receive plaster and removing demolished materials outside MD land, complete all as specified and directed.
Taking down cement plaster of any description and thickness on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
Taking down chowkhat or frames not exc 1.50 Sqm each with shutters (with out taking off shutters from the frame), complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and pavings n.exc 15 cm thickness (below or above GL) and removing rubbish from premises, complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, any thickness incl hooks and ridge as retrieved from site complete all as specified and directed.
Dismantling floor, hearth or wall tiling/ terrazzo including cement mortar bedding (but not backing), removing tiles and rubbish off the premises, complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work & precast concrete articles, complete all as specified and directed.
M&L brick work with old size pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggreate), 75 mm thick as in plinth protection/Path/PCC paving etc including finishing the surface even & smooth without using extra cement, with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where dirtected and providing 6 mm wide joints throughout the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three parts of fine sand by weight), complete all as specified & directed.
M&L for 100mm thick PCC 1:2:4 mix, type B2 (using 40mm graded crushed stone agg) as in path/hard standing etc, finishing surfaces even and smooth without using extra cement, laid in panels, complete all as specified and directed.
M & L for providing cement concrete 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in surface channels and drains and benching & including finishing the top as required shape, even and smooth without using extra cement & incl necessary formwork complete all as specified and directed. Note :- Forming fair finished channel shall be measured and paid separately under respective item of the BOQ.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement & including forms, moulds mitred/stopped ends etc complete all as directed. Note :- Measurment shall be taken only for inner girth.
M&L for PCC 1:4:8 type D-2, using 40 mm graded crushed stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2, using 40 mm graded crushed stone aggregate, as in foundation, filling, mass concreting etc, complete all as specified and directed.
S&F rolled mild steel pipe or other sections as in posts, framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc conforming to Fe-410W, Grade-E-250, quality 'A' complete all as specified and directed.
S&F rolled mild steel for roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410W, Grade-E-250, quality 'A' complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, wall cladding etc, fixed to iron/wooden members with self drilling zincoulium coated metal screws having cap with rubber and metal washers, complete all as specified and directed.
M&L for PCC 1:2:4 mix type B-0 (using 12.5 mm graded crushed stone agg) for roof padding, leveling course to receive floor finishes etc, complete all as specified and directed.
M&L brushing neat cement slurry with 3.00 kg cement per Sqm, complete all as specified and directed.
M&L for applying 15 mm thick screed in CM 1:4 on roof slabs with using liquid water proofing compound as per manufacturer's instructions, complete all as specified and directed. (Liquid WPC shall be measured and paid separately).
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm.
Item 22.00 Contd........ (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Cost of above aspects is deemed to be included in quoted rates.
BLANK
Supply only approved liquid water proofing compound, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt of extruded section 150 mm long and fixed, complete all as specified and directed.
S&F aluminium handles, cast type, anodised 150 mm size, complete all as specified and directed.
S&F 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21, complete all as specified and directed.
S&F in renewal of 'D' type tubular towel rail 60 cm long, brass chromium plated, 20 mm dia, complete fixed with stainless steel screws, complete all as specified and directed.
S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium frame for doors, windows, ventilators & partition etc., with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F Powder coated (thickness of powder coating minimum 50 micron) anodised aluminium window and ventilator shutters, side hung without sash bars, aluminium sections weighing 0.55 kg/m & including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 No.), suitable handle (1 No), complete all as specified and directed. Note :- Wire cloth & Glass pane shall be measured and paid for separately.
Supply, fabricated & fixing Powder coated (thickness of powder coating minimum 60 micron) anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge.
Supply only 5.5mm thick sheet glass ordinary quality, cut to size as required at site, complete all as specified and directed. (Cost of fixing of glass shall be deemed included in the unit rates under respective items.)
Supply only stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, complete all as specified and directed. (Note: cost of fixing of wire cloth shall be deemed included in the unit rates under respective items.)
S & F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as applicable to item 08095 given in SSR Part – II (2020).
S & F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppy and fixing in the frame at site complete all as per specifications and drawings as applicable to item 08080 given in SSR Part–II.
S & F of framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with including either hooks and hinges or steel hanging door fittings (excluding of steel sheeting or other covering running rails and guides) and hanging also fastening and fixing, conforming to Fe-290 Grade-E-165, complete all as specified and directed.
S&F mild steel framed work as in grills, grating etc. with end of bars shouldered and/or riveted, or forged into spikes: framed guard bars: barred iron doors: ladders: cages, frame balusters: walk ways: railing: frame work of water tanks and similar works conforming to Fe-290 Grade-E-165, complete all as specified and directed.
S&F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240, complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, wall cladding etc, fixed to iron/wooden members with self drilling zincoulium coated metal screws having cap with rubber and metal washers, complete all as specified and directed.
S&F welded steel wire fabric weight per square metre not exc 4 kg, fixed to wood or steel members, complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 type D-2, using 40 mm graded crushed stone aggregate, as in sub base of floors, etc., finished surface even & fair to receive floor finishes/ screed complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block any shape and size made with grey cement and pigment, confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, laid over and including 25 mm thick sand cushioning, complete all as specified and directed.
M&L precast (factory casted) cement concrete kerb stone casted in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate with plain or interlocking joints (as directed) including weathering, slightly rounded or chamfered angles, placing in position, set and jointed in CM 1:4, complete all as specified and directed.
M&L for 25mm thick plain cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in flooring /sub base finished surface even & fair to receive floor finishes/ screed complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
M&L for machine cut kota stone slab as in flooring 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and mirror polishing by applying wax polish, laid over and including 20 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for machine cut kota stone slab as in skirting, dado, risers etc, 20 to 25 mm thick and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding, rubbing and mirror polishing by applying wax polish, laid over and including 15 mm thick rendering in CM 1:4, complete all as specified and directed.
M&L black granite (of any type) slab 18-20 mm thick, table rubbed and mirror polished by applying wax polish as in cooking platform, jambs, cills, pillars, tread, risers, platform for WHB etc including bull nosing to exposed outer edges, set in CM 1:4 bedding and pointing with white cement mixed with pigment and provn of hole for gas pipe, laid over and including 20 mm thick screed bed in CM 1:6, complete all as specified and directed. Note :- Granite stone slab shall be laid in single piece with rounding of edges and a grove shall be provided beneath the projection portions of slab.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on stone masonry surfaces or other than fair faces of brick work in cement mortar 1:6, surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick on stone masonry surfaces or other than fair faces of brick work in cement mortar 1:4 with using liquid water proofing compound, surface finished even and smooth without using extra cement, complete all as specified and directed. (Liquid WPC shall be measured and paid separately).
M&L for preparing new steel surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of red oxide zinc chrome primer, complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying 3 mm thick wall care putty as per manufacturer's instructions and over it applying two coats of distemper oil emulsion over and including a coat of alkali resistant primer, complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint over and including a coat of white wash, complete all as specified and directed.
M&L for applying two coats of white wash with using putty to fill depressions etc., after preparation of old previously treated plastered surfaces of ceiling, complete all as specified and directed.
S&F in renewal of HDPE PVC connection 450 mm long suitable for 15 mm GI pipe with two PTMT nuts and rubber washers complete all as specified and directed.
S&F in renewal of vitreous china wash hand basin, white, counter top type, size 550x400 mm, excluding chain and plug, taps and porcelain stopper but incl PVC waste pipe of 32 mm bore, suitable size of waste fittings, one pair of 600 mm long cast iron brackets, complete all as specified and directed.
S&F in renewal of shower rose, chromium plated brass, 125 mm size with swivel joint, screwed to iron pipe or for union of 15 mm dia, complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 15 mm bore pipes complete all as specified and directed.
Taking up or down existing GI tubing and connections, including making good the disturbed surface for 20 mm bore pipes complete all as specified and directed.
Supply, fixing, laying & testing 15 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to walls, ceilings or floors, complete all as specified and directed.
Supply, fixing, laying & testing 20 mm bore galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket, reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed to walls, ceilings or floors, complete all as specified and directed.
Dismantling existing water storage tank of any description of capacity exc. 500 ltr but n.exc. 1000 ltr, complete all as specified and directed.
S&F in position rotational moulded polyethylene water storage tanks 1000 lts capacity, white colour (cylinderical vertical with closed top) hoisted and fixed in position, complete all as specified in SSR Part I and as directed. Note:- PVC tank shall be ISI marked and having three layers.
S&F of 20 mm dia ball brass valve, high pressure with polythene float and fly nut, screwed down for iron pipe, complete all as specified and directed.
S&F in renewal of 20 mm bore stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for union complete all as specified and directed.
S&F in renewal of stop valves 15 mm nominal bore, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfllly handles, screwed both ends for iron pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in renewal of bib taps, cast copper alloy, with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket complete all as specified and directed.
S&F in renewal of pillar taps 15mm dia, cast copper alloy, with capston heads, chromium plated, fancy type, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
S&F in renewal of angle valve 15 mm bore cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed, complete all as specified and directed.
S&F in renewal of vitreous china squatting pan Orissa pattern size 580 x 440 mm white with front or back inlet, integral foot rest incl providing lime concrete bedding and connecting to flusing cistern, complete all as specified and directed.
S&F vitreous china wash down water closet pan (pedestal pattern) white with 'P' or 'S' trap front or back inlet & including connection to drain or out going pipe and to flushing pipe, antisyphonage pipe etc., & including plastic seat cover white with flat bottom and mild steel chromium plated or aluminised hinging device, complete all as specified and directed.
S&F in renewal of 10 Ltr capacity PVC low level flushing cistern, top push type with inlet ball valve, PVC float, brackets & including superior quality PVC flush pipe of 32 mm dia, complete all as specified and directed.
S&F in renewal of vitreous china half stall type urinals, bowl type, flat back of size 465x355x265mm, white with grating and union for discharge pipe, including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back with white cement & incl PVC waste pipe of 32 mm bore, suitable size of waste fittings complete all as specified and directed.
S&F in renewal of grating doom of 140 mm dia, made of PTMT with or without waste hole (Minimum weight 50 gm), complete all as specified and directed.
BLANK
Dismantling cast iron or reinforced concrete drain pipes 100 mm bore alongwith fittings and accessories, jointed in CM and taking out from walls, floors or from trenches, if required, complete all as specified and directed.
Dismantling cast iron or reinforced concrete drain pipes 75 mm bore alongwith fittings and accessories, jointed in CM and taking out from walls, floors or from trenches, if required, complete all as specified and directed.
S&F cast iron (sand cast) soil, waste and vent pipe 100 mm bore in any length with or with out ears with cement joints laid in trenches or in floors, complete all as specified and directed.
S&F cast iron (sand cast) soil, waste and vent pipe 75 mm bore in any length with or with out ears with cement joints laid in trenches or in floors, complete all as specified and directed.
S&F 100 mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured), complete all as specified and directed.
S&F 75 mm bore CI bend (any radius), diminishing pieces or tapers (larger bore measured), complete all as specified and directed.
S&F cast iron (sand cast) soil, waste and vent pipe 100 mm bore in any length with or with out ears with cement joints fixed to walls, complete all as specified and directed.
S&F cast iron (sand cast) soil, waste and vent pipe 75 mm bore in any length with or with out ears with cement joints fixed to walls, complete all as specified and directed.
S&F CI branch pieces 100 mm dia single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and directed.
S&F CI branch pieces 75 mm dia single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches with oval access door complete all as specified and directed.
Demolition and breaking up drain pipes 150mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested, for 150mm bore of pipe complete all as specified and directed.
M&L 150 mm bore salt-glazed stoneware drain pipes laid in trenches and jointed with cement joints, complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil, each not exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm around foundation concrete as ordered, watering and removing surplus soil to a distance not exceeding 50 m and making good surface, complete all as specified and directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep for foundation etc or for shafts, column footings or for laying cables etc not exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in excavated soil including spreading, levelling, watering and well ramming in layers not exc 25 Cm, complete all as specified and directed.
M&L Moorum or red bajri filling in floor or paving, laid in layers not exceeding 15 Cm thick, spread, leveled and rammed including watering, complete all as specified and directed.
M&L hardcore (broken stone) of gauge not exc 63 mm, deposited spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Removing excavated materials (soil) not exc 50 m distance and depositing where directed at a level not exc 1.5 m above the starting point, complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for reuse or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Dismantling unserviceable main switch/DBs incl wooden board and deposit to MES store yard including making good disturbed surface of wall complete all as specified and directed.
Taking down sub main wiring /XLPE cable of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surface, complete all as specified and directed.
M&L for Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 1.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface including providing wooden rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surfaces, complete all as specified and directed for the following: - One light/ceiling fan/exhaust fan/bell buzzer point controlled by one, one way switch of 5/6 Amps. Note :- Cutting chases (if required) and making good to match with the adjoining surface shall be included in the unit quoted rate.
All as per item No 103.00 (here-in-before) but one 5 Pin, 5/6 amps socket outlet point on independent board, controlled by one, one way 5/6 Amp switch.
All as per item No 103.00 (here-in-before) but one 5 Pin, 5/6 amps socket outlet point on same board, controlled by one, one way 5/6 Amp switch.
M&L Point wiring with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable of size 2.5 Sqmm, with PVC insulated (FRLS) unsheathed multi stranded copper conductor cable FRLS of size 2.5 Sqmm as earth continuity wire to be drawn in and including PVC casing capping not less than 20 mm width with all accessories and fittings, fixed on surface for one socket outlet 15 amp on independent board including providing wooden/PVC rectangular block for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover and making good disturbed surface, complete all as specified and directed.
S&F switch piano flush type 5/6 Amps, 230 volts, single pole, one way, ISI marked, complete all as specified & directed.
Supply and fixing switch socket combination, 5/6 and 15/16 Amps, 230 volt, multi pin, flush type universal, complete all as specified and directed.
Supply and fixing socket outlet, 5/6 Amps, 230 volt, five pin, flush type universal, complete all as specified and directed.
S&F PVC/polycarbonate lamp holder, angular/batten type with back plate, ISI marked complete all as specified & directed.
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65x 50mm, 3 terminals, complete all as specified & directed.
S&F in renewal of wall mounted 18 watt LED Tube light fittings, batten type with bipin holders, powder coated steel with internally prewired, complete all as specified and directed.
S&F in renewal of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.
M & L in renewal of street/road light GI mounting bracket made out of steel tube, medium grade, 40 mm dia (or higher size to suit the opening of the fitting) 1.50 mtr long by hydraulic pressed mechine bend to require arc shape and fixed to pole with 02 Nos MS flat iron clamps of suitable size fixed with bolts, nuts and washers including drilling holes and grouting with the same for fixing bolts as required & incl duly painted with two coat of aluminum paint over a coat of aluminum red oxide primer and fixing with lights fittings on the existing old street light poles complete all as specified and directed. Note :- Cost of Necessary tools and plants such as ladders, hydra for renewal of mounting brackets, light fittings, nuts, bolts etc shall be deemed to be included in the unit rate quoted.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volt, 10 KA 'C' curve including all accessories, complete all as specified and directed.
S&F MCB, 6 to 32 Amps, Single Pole & Neutral, 240 Volt, 10 KA 'C' curve including all accessories, complete all as specified and directed.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 8 ways, Double door, complete all as specified and directed. Note for items of MCB DB - (1) The unit rate includes for cutting the brick/stone walls to accommodate DB to make flush to wall. (2) The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface.
M&L for MCB DB made of sheet steel phosphatised, powder painted with bus bar 200 A, neutral link, earth bar and Din rail, 240 Volts SPN with 4 ways, Double door, complete all as specified and directed.
S&F of sub main wiring with two runs of single core PVC insulated and unsheathed FRLS multistranded copper conductor cable of size 6 Sqmm LT, 1100 volts grade, drawn through and including 20 mm dia PVC non metallic surface conduit with accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc. and fittings and one run of 6 sqmm single core multistranded FRLS copper conductor cable green colour as earth continuity conductor, complete all as specified & as directed. Note :- Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm dia shall be measured as one run length. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the PVC conduit.
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized iron earth wire of 4 dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15 mm bore light grade GI tubing for protection of earth wire, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling and taking out old earthing complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 5 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth wire upto 7.5 m. Any variation below or above shall be measured and paid for separately under relevant item of this Sch ‘A’.
L P Singh and Co.
M/S MOHINI ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .