| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.7 L+₹73,602.09 (4.33%)Rejected-AOC 65 MATA KA MANDIR RAM NAGAR COLONY SHAHJAHANPUR 242001 UP | SHAHJAHANPUR | SHAHJAHANPUR | UP | 242001 | L2 | Rejected-AOC L2 |
Tender Value
₹16.3 L
EMD Value
₹32,540
Closing Date
6 Aug 2020, 6:00 pmClosed
GE 871 EWS
GE 871 EWS C/O 56 APO JOSHIMATH
PROVN OF ADDITIONAL DUST PROOF STORE AND AC ROOM FOR STORAGE OF OIL AND LUBRICANT AND PROVN OF PCC ROAD FROM MAIN ROAD TO MT SHED AT 41 FARS AT JOSHIMATAH
2020_MES_335360_4
8520/E8
Open Tender
Civil Works
Works
180 days
JOSHIMATH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 871 EWS
₹32,540
2 Sept 2020
27 Jun 2020
8 Aug 2020
29 Jun 2020
6 Aug 2020
6 Jul 2020
29 Jun 2020 - 6 Aug 2020
Amount
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in soft loose soil all as specified and directed.
Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in hard dense soil all as specified and directed.
Rough excavation nexc 1.5 m deep and getting out in hard dense soil all as specified and directed.
Rough excavation nexc 1.5 m deep and getting out in hard rock by using mechanical plant or chisel cutting all as specified and directed.
Excavation over areas nexc 1.5 m deep and getting out in soft loose soil all as specified and directed
Excavating over areas n exc 1.5 m deep and getting out in hard dense soil all as specified and directed
Excavation over areas n.exc 1.5 m deep and getting out in hard rock by using mechanical plant or chisel cutting all as specified and directed.
Excavation in trenches n exc. 1.5 metre wide and n exc. 1.5 metre in depth for foundation and getting out in soft loose soil all as specified and as directed.
Excavation in trenches n exc. 1.5 metre wide and n exc. 1.5 metre in depth for foundation and getting out in hard dense soil all as specified and as directed.
Excavation in trenches n exc. 1.5 metre wide and n exc. 1.5 metre in depth for foundation and getting out in hard rock using chisel/ pneumatic hammer complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm in soil all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in soil all as specified and directed.
Removal of surplus soil n exc 100 metre and depositing where directed at a level n exc 1.5 metre above the starting point all as specified and directed.
Removing excavated material to a distance exc 250 metre but n exc. 500 metre and depositing where directed at a level nexc 1.5 metre above the starting point in soil all as specified and directed.
Removing excavated material to a distance exc 500 m but n exc 1 km and depositing where directed at a level n.exc 1.5m above the starting point in soil all as specified and directed.
M&L hardcore of broken stone of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed.
Hand packing, except material (any thickness) at back of walls and raising (or lowering) to the required level all as specified and directed.
M&L for sand cushioning for cable protection with approved sand of uniform thickness, laid dry, by filling in trenches and punning to have proper required cover all as specified and as directed. Note:- For the purpose of payment only punned thickness will be measured.
M & L PCC 1:4:8 Type D2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete all as specified and directed.
M&L PCC 1:2:4 type B-2,(using 40mm graded crushed stone aggregate) as in sub base all as specified and directed.
M&L reinforced cement concrete M 25 grade(design mix using 20 mm graded crushed stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, basement slabs, under-reamed piles and mass concrete all as specified and directed.
M&L reinforced cement concrete M 25 grade (design mix using 20 mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts all as specified and directed.
M&L reinforced cement concrete (nominal mix) M 25 (using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummer, lintels over 1.5 m span all as specified and directed.
Spreading and levelling in layers n. exc. 25 cm thick including well ramming , watering in layers
M&L PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in coping including weathering throating and necessary form work all as specified and directed.
M&L precast cement concrete bonder using PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) in lieu of stone bonder and set in CM 1:6 including necessary form work all as specified and directed. Note :- (a) This item is applicable for item No 29 & 30 here in before only. (b) No deduction in volumes as well as in rates shall be made for use of PCC bonder in lieu of stone bond stones in random rubble masonry.
Supply & laying of well burnt sub class 'B bricks for cable protection width equal to length of bricks laid in trenches flat all as specified and directed.
M&L precast cement concrete solid block masonry 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) with solid block exc 10cm in width setting in CM 1:6 all as specified and directed.
M&L walling of random rubble, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work all as specified & directed.
M&L walling of random rubble stone masonry uncoursed or brought upto courses well bonded, bedded and solidly hearted built in cement mortar 1:6 all as specified and directed.
Extra over stone walling for hammer dressing to face stones & dressing of face beds & joints, with maximum depression on face from straight edge held against the dressed surface n.exc 40 mm; to random rubble masonry all as specified and directed.
Use & waste form work to sides of concrete foundations, footing, plinth beams of column and the like similar work vertical or batter for rough finished surfaces of concrete all as specified and directed.
Use & waste form work to sides of pillars,column,posts struts piers, fair finished surfaces of concrete square retangular or polygonal at a level upto 7.50 m height above, ground level all as specified and directed.
Use and waste formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams all as specified and directed.
S&F 35 mm thick flush door shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed
S&F MS barrel tower bolts stove enamelled black with bright bolts 200mm long all as specified and directed
S&F mild steel pressed handles, oval type, stove enamelled black 125mm long all as specified and directed
S&F butt hinges medium weight cold rolled mild steel 100 mm all as specified and directed
S&F mild steel sliding door bolts, 300 mm long plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate all as specified and directed
M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed
All as per item No 40 above but 8 mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and directed
S&F Fe 410-W Gde E-250 quality A plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment all as specified and directed
S&F mild steel bolts, purpose made, dia of neck exc 12 mm but n exc 20 mm with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut, exc 30cm long all as specified and directed
S&F roof trusses (framed), trussed, purlins, crane gantries, rails FE 410W (Gde E-250) quality B and fastenings and heavy brackets framing (beam, tee, angle channels or flat sections) including distance pieces cleats, etc all as specified and directed
S&F Fe 410-W Gde E-250 quality A rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates all as specified and directed
M&L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls,fixed with self tapping screws all as specified and directed.
M&L pre-painted galvanlume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to walls,fixed with self tapping screws all as specified and directed
S&F mild steel screw bolts (machine made ) with hexagonal or square head at one end and screwed the other ends, each screwed end fitted with washers and one hexagonal or square nut exc 5 cm but n.exc 10 cm long all as specified and directed
M&L for everest designer false ceiling using GI exposed ceilig suspension system of grid size 600mm x 600mm with main runner 38mm x 24mm ,cross tee 29mm x 24mm and wall angle 24mm x 24mm. Using 6 mm thick (High pressure steam cured ), pre-painted self embossed, reinforced designer cement bond, confirming to IS 14682 : 2000 to be placed in a grid of G.I. system duly suspended with 4mm dia G.I/ M.S. bar hangar fixed wth steel dash fastene or iron purlins from the roof with adjustment clip providing position for light fixture etc all as specified and directed.
S&F pressed steel frames 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified and directed
M&L providing 75 mm thick PCC 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in sub base all as specified and directed.
M&L 100 mm thick sub base in PCC 1:3:6, type C-2, ( using 40mm graded crushed stone aggregate) all as specified and directed.
M&L 40 mm thick PCC 1:2:4 type B-2, (using 20mm graded crushed stone aggregate) as in floor finished surfaces even and smooth without using extra cement all as specified and directed.
M&L 75mm thick PCC 1:3:6 type C-1, (20mm graded stone agg ) as in plinth protection finishing the cement concrete surface even and smooth without using extra cement.
M&L rendering 15mm thick on other than fair faces of stone or concrete surfaces using river sand in CM 1:6 finished surfaces even and smooth w/o using extra cement all as specified and directed
M&L rendering 15mm thick on fair faces of stone or concrete surfaces using river sand in CM 1:4 finished surfaces even and smooth w/o using extra cement all as specified and directed
M&L raised pointing in river sand to random rubble uncoursed stone masonry in CM 1:4 all as specified and directed. .
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of primer all as specified & directed.
M&L preparation of surfaces and applying three coats of white washing on newly plastered surfaces of walls all as specidied & directed.
M&L preparation of new wooden surfaces of any description over 10cm width or girth applying & applying two coats of synthetic enamel paint over a coat of pink primer all as specified & directed.
M&L preparation of new steel surface of any description over 10cm width or girth & applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified & directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length fixed in walls and floors or trenches etc. as in weep holes of retaining wall all as specified and directed.
M&L soling 150 mm thick with broken /quarried stone, intersticies filled, surface formed and rolled and consolidated to required gradient and cambers all as specified and directed.
M&L cement concrete work in pavement/hard standing of flexural strength 40 Kg/Sq cm in field using 400 kg of cement/cum, thickness of concrete 15 cm or less including formwork complete all as specified and directed.
M&L forming 12mm thick expansion joints filled with pre formed bituminious filler and top 30 mm primed and sealed with sealing compound grade B, thickness of slab 150 mm thick all as specified and directed.
M&L for forming construction joints 30mm deep x 10mm wide, filled with sealing compound grade 'B' all as specified and directed.
Forming Contraction (Dummy) joints 50 mm deep x 10mm wide, filled with sealing compound all as specified and directed.
M&L finishing top surface of concrete roads/ pavements by brooming all as specified and directed.
M&L for point wiring in steel conduit conceled of required size confirming to IS 2079-1973 medium grade with PVC insulated unsheathed multistranded copper conductor cable (FR) 1.5 sqmm nominal cross sectional area, 1100 volts grade complete with all fittings such as elbow, bends, junction boxes, saddles including PVC board (ISI Mark) and screws and rawal plug etc including 1.5 sqmm PVC insulated & unsheathed copper conductor cable as earth wire and connected to light/fan & common earth dolly with necessary copper thimbles all as specified and directed for one light/fan/bell point controlled by one one way switch .
S&F switch piano flush type 5/6 Amps single pole one way all as specified & directed.
M&L ceiling rose 2/3 terminals 65x25 mm dia poly carbonate isolated all as specified and as directed.
S&F LED 4' tube light fitting bright 18 watt slim elegant design model No 61009 and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. Make : Havells/Philips/Bajaj
S&F new security light fitting complete with 25 watt LED type pressure die cast aluminium housing and heat resistant toughned glass with frame protection and better optics for uniform distribution etc complete fixed bracket made out by GI pipe (light grade ) 40mm mm and MS clamp and nut bolts washers etc complete and connected with twin core cable 1.5 sqmm from ceiling rose to fitting connector all as specified and directed. Make Havells/Philips/Bajaj
S & F FPL light fitting, 1x18 w, 230v recessed mounting mirror optic Iuminare with P5 paralite louvers complete for POP ceiling, with lamp holders, ballast, connector block, etc. complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed. Make Havells/Philips/Bajaj.
M&L earthing complete with galvanished steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below normal ground level connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 mtr long, etc complete all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 mtr will be measured and paid separately
S&F MCB DB SPN, 8 way 240 volt , double door type MCB DB suitable for mounting incoming and outgoing MCBs double pole/single pole all as specified and directed. Make Havells/Legrand/Schneider.
S&F MCB single pole with thermal over load as well as magnetic short circuit tripping device with quick, break trip free mechanism, robust design and terminals having heat resistance moulding suitable for single phase circuit of 6 to 40 Amp. Make - Havells/Legrand/Schneider
All as per item No 77 above but MCB DP 32/40 Amps. Make:- Havells/Legrand/Schneider
M&L for single pointed air termination aluminium rod 12mm dia, 300 mm long all as specified and directed.
M&L Test point terminal block of gun metal or phosporus bronze size 75x75x25mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexogonal head screw all as specified and directed.
M&L Aluminium strip 25mm x 3.15mm complete with saddles and fixing screws for fitting the strip all as specified and directed.
M&L for 32 mm dia steel tubes (light grade) galvanised iron with allfittings and fixtures, laid in trenches/wall/pole for protection of underground cable when crossing the road. (MAKE: JINDAL/ PRAKASH/SURYA)
Supply and lay in trenches , fixed to wall/pole UG Cable XLPE insulated screened PVC beded galvanised steel strip or wire armed heavy duty electric cable with multi stranded Aluminium conductor , 1100V grade of size 16 sqmm 4 core all as specified and directed.
supply and fixing room Split type inverter technology air conditioner with indoor and outdoor unit dual mode (heating and cooling), electric driven, single phase, of capacity 1.5 Ton, cooling capacity 6000 K cal per hour and BEE 4 star rated all as specified and directed. Make: Blue Star/LG/Carrier/Hitachi/Voltas
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type, copper wound ,digital voltmeter/Ammeter & designed for input variation between 135 V to 280 V with output voltage stabilized at 220V with accuracy of ± 8% and of capacity 5 KVA for Split air conditioner all as specified and directed. Make: V- Gaurd/AE/APLAB/VOLINA
M&L sub main wiring in steel conduit/conceled of required size 2x4 sqmm PVC insulated multistrand copper conductor with 01x2.5 Sqmm PVC insulated multistrand copper conductor as earth continuity wire complete all as specified and directed. Make : Havells, Plaza, Polycab
S&F MCB single pole with thermal over load as well as magnetic short circuit tripping device with quick , break trip free mechanism , robust design and terminals having heat resistance moulding suitable for single phase circuit of 32 Amp. Make - Havells/Legrand/Schneider
M/S CHAUHAN ELECTRIC WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .