Loading…
Loading…
Tender Value
₹22.3 L
EMD Value
₹44,700
Closing Date
11 Apr 2025, 11:00 amClosed
(A) Electrical work in connection with Paharpur Augmentation and upgradation of OHE depot and Tower wagon shed at Paharpur depot in Dhanbad Division (B) Provision of APFC Panel at various pump houses over Dhanbad division
EL-40-OPEN-2024-25
EL-40-OPEN-2024-25
Open
Works - General
9 Months
Dhanbad, Jharkhand
₹0
₹44,700
17 Mar 2025
17 Mar 2025
PT -Part-A (Paharpur Augmentation and upgradation of OHE depot
Fixing, connection, testing & Supply of LED Batten, Box type luminaire, with CRCA body, Pre wired for LED tube with supply of Retrofit LED tubular lamp 1X20W,T-8, 4' long, complete with inbuilt LED driver, Make - Crompton, Goldwyn, Havells, Bajaj, Polycab Philips & Jaguar (LED Luminarie of the makes as specified above should be as per RDSO's specification for Energy efficient 1 LED based luminaire unit for indoor lighhts to be used in Indian Railway offices and buildings. (Fixing of fitting to be done with proper clamping arrangement as per the site requirement and connection to be done with1.5 sqmm single core copper conductor FRLS by tapping from sub main line including supply of ceiling rose and wires and PVC flexiable pipe) ( The complete system of LED lights (including Driver etc) shall be guaranteed for satisfactorily performance and manufacturing defects for period of 60 months from the date of commissioning or 72 months from the date of suppply, whichever is earlier.(Reference: Railway Board's letter no.2006/Elect(G)/150/5 dated 27.03.15).
Fixing, connection, testing, commissioning & Supply of LED Highbay luminaire 150W similar to Bajaj electrical DURANTO product code 169709 , BGHB 150W LED with fin ventilation technology for better thermal managment and with cutting edge LED technology (Make- Goldwyn , 2 BAJAJ, PHILIPS, C&S,Cromption) above fitting should be fixed on steel structure including supply, fabrication of suitable clamping arrangement made of M.S Flat 25x3 mm size, with supply of suitable bolts, nuts, and washers as per the site requirement ( The complete system of LED lights(including Driver etc) shall be guaranteed for satisfactorily performance and manufacturing defects for period of 60 months from the date of commissioning or 72 months from the date of suppply, whichever is earlier.(Reference: Railway Board's letter no.2006/Elect(G)/150/5 dated 27.03.15).
Wiring of light point with PVC insulated, sheathed & stranded single core copper conductor( FRLS) 1.5mm2 (Wire Make-Havells, anchor, Finolex, Polycab, Mescab) with ECC in PVC pipe in concealed with proper excavation and refilling the wall with proper plastering of the wall with supply & fixing of switch, ceiling rose/angular batten holder etc(.make Havells, anchor,Legrand, Slemens, L&T,or C&S)
Supply,& fixing of Metal body Exhaust Fans (non-capacitor type) No of poles -4 & 4 sweep size 300 mm (Make-Usha,Havells/crompton, Bajaj ) ( fixing of exhaust fan to be done by cutting the hole of required size along with supply and grouting of required nut, bolt & waser to suit the Ex-fan as per site requirement, including connection. )
Fixing, connection, testing and Supply of Wall Bracket fan 400 mm sweep complete with all accessories Make: Bajaj, Crompton, Havells or Usha
Wiring of C- Fan/Ex-Fan point with PVC insulated, sheathed & stranded single core 6 copper conductor FRLS 1.5mm2 (Wire Make-Havells, anchor, Finolex, Polycab, Mescab ) with ECC in PVC pipe in concealed with proper excavation and refilling the wall with proper plastering of the wall with supply & fixing of switch, ceiling rose, regulator .(make-Havells, anchor,Legrand, Slemens, L&T or C&S) on surface of wall with ECC including supply and fixing of switch and ceiling rose.
Wiring of plug point with PVC insulated, sheathed & stranded single core copper 7 conductor FRLS 1.5mm2 (Wire Make-Havells, anchor, Finolex, Polycab, Mescab) with ECC in PVC pipe in concealed with proper excavation and refilling the wall with proper plastering of the wall with supply & fixing of 5Amp plug & socket switch (make-Havells, Anchor, Legrand, L&T, Seimens or C&S)
Wiring of power plug point 15 Amp with PVC insulated, sheathed and stranded single 8 core, copper conductor FRLS 4mm2 (Wire Make-Havells, anchor, Finolex, Polycab, Mescab) with ECC in PVC pipe in concealed with proper excavation and refilling the wall with supply & fixing of 15Amp Power Plug & Socket flush type, 5 in 1 including controlling switch.(make-Havells, Anchor, Legrand, L&T, Seimens or C&S)
Wiring of sub-Main Line with FRLS copper wire single core size 6mm2 multistrand with PVC pipe concealed with proper excavation and refilling the wall with proper plastering. (Wire Make- Havells,anchor, Finolex, Polycab Mescab)
Wiring of Main Line with FRLS copper wire single core size 10mm2 multistand with PVC pipe in concealed with proper excavation and refilling the wall with proper plastering. (Wire Make-Havells,anchor, Finolex, Polycab, Mescab)
Fixing, connection, testing & Supply of MCB Distribution Board 8-way (2-incomer ,6- outgoing),double door,IP-43-protection conforms to IS:8623-1&3, MCB 32A, DP, 10 KA, B-Curve, 11 conforms to IS:60898 - 1 No as incoming, MCB 10A, DP, 10 KA, C-Curve, conforms to IS:60898 3 Nos as outgoing. Make - L&T, Havells, Legrand (Fixing of Distribution Board to be done with proper clamping arrangement as per the site requirement and connection to be done with suitable conductor including supply of PVC flexiable pipe)
Testing, commissioning, installation and supply of MCCB,100A, 35KA, four pole, with 12 thermal magnetic release with suitable MCCB enclosure. Fixing to be done as per the site requirement (normally concealed) under supervision of site incharge including connection with crimping of cable ends with aluminium lugs of required sizes (Make -Indo asian, C&S, Havells, L&T
Supply & fixing of Busbar Chamber 4-way 100A (Make Havells/C&S/L&T) (Fixing with proper excavation and refilling the wall with proper re-plastering of the wall)
Trenching, laying and back filling of XLPE cable as per Sr.DEE(G)/DHN's drg. No. EL/486-01 (cable will be supplied by the Railway)
Laying and fixing PVC/XLPE cables of different sizes ranging from 25 sq mm to 120 sq mm on surface of the wall (normally concealed)/steel structure as per the requirement of site with proper clamping arrangement as required at every 1/2 metre. (Cable will be supplied by Railway)
Installation, connection, testing and Supply of LED Street Light Fitting 72W ±5%, similar to Havells model OMNIPLUS, made up of pressure die cast aluminium housing with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. Light source - High efficiency long life LED module with SMD LED package mounted on MCPCB. Lumen efficacy of LED >140 lm/W. System Lumen Efficacy 110Lm/W, Electronic driver- Powered by integral, isolated electronic LED driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Over Voltage protection, Surge Voltage protection 10KV with SPD & other safety test as per IS 15885 Part-2/Sec 13. Warranty 5 years. (Make- Havells, Crompton, Bajaj, Philips). Connection to be made with PVC insulated S/core stranded alum. FRLS Conductor 2.5mm2 with PG clamp of required size (including supply)
Supply of Bend GI pipe of 30mm dia x 4ft long (to suit the street light fitting) as per site requirement and fixing the same on pole with supply of suitable clamp, nut, bolt and washer.
Wiring of Sub main concealed/surface(Normally concealed) in separate heavy gauge PVC conduit pipe 20mm size with single core PVC insulated multi strand copper conductor FRLS cable 18 2 nos of 4 sq.mm each for phase and neutral. The colour coding of cable red for phase,black for neutral must be maintained . No other sub-main & point wiring will be drawn with this sub-main wiring in same PVC pipe. PVC pipe make - Polycab, Pressfit, Precision. Wire/cable make-Havells, Polycab, Finolex
Fixing, connection, & Supply of Celling rose and flexible pipe along the sub main line as required for connection of tube fitting, fan etc (.make Havells, anchor,Legrand, Slemens, L&T,or C&S)
Provision of Earthing station (RI-7021) as per Drg.No. ETI/ OHE/P/ 7020 or latest
Fixing, connection, testing, commissioning & Supply of cable junction box IP-65 with metric knockouts for cable entry suitable for cable size 16/25 Sq.mm withouts terminals similar to Cat 21 No.-K9250 of HENSEL with Grommets IP-65 EDK-40- 2 Nos including fixing, cable junction boxes should be fixed on OHE mast with proper clamping arrangement comprising MS flat 32mm and suitable bolts nuts and washers as per the site requirement including connection with crimping of cable ends with suitable size of crimping socket as required under the supervision of site encharge
Fixing, connection, testing, commissioning & Supply of Thermoplastic circuit breaker boxes with protective cover, IP65 protection similar to Cat No.-KV7106 of HENSEL, 1row 6 modules having 2XM20 knockouts each at top and bottom walls - 1 nos, alongwith Grommets IP65 M20-4 Nos 22 including supply of single core 10 Sq.mm multistrand cable-6 Meter Circuit breaker boxes should be fixed on OHE mast with proper clamping arrangement comprising MS flat 32mm and suitable bolts nuts and washers as per the site requirement including connection with crimping of cable ends with copper reducing lugs 6 Sq.mm (bottleneck type 4 nos. dowells make) as requirred under the supervision of site incharge.
PT -Part-B (Provision of APFC Panel at various pump houses over
Supply & fixing of 20 KVAR APFC Panel Board made up of 1.6mm/1.8mm CRCA Sheet duly powder coated with Siemens grey RAL 7032/7035 with locking arrangements, Dust & Vermin proof, aluminium Busbar with color coded sleeves Indicating Lamps with control fuses, APFC relay 8stage.(Without Reactor). The automatic power factor controller panel 20 KVAr (approximately) capacity shall incorporate microprocessor based digital controller with provision for manual control 6 when the APFC relay fails. During normal automatic operation the microprocessor-controlled relays shall 'pick out' the correct capacitor size by referring to the actual demand of reactive power directly and do the correct 'C/k' adjustment automatically. The controller should be capable of maintaining power factor at 0.99 lagging to unity power factor. Component wise details for major components are as given below: Configuration: 20 KVAR APFC Panel, 4stage: (4x5KVAr), Capacitor must be Metallic poly propylene (MPP) type heavy duty , delta connected power capacitors suitable for operation with 415 volt , 3 phase , 50 Hz. AC supply with in-built discharge resistance. Make: SIEMENS, GE POWER, ABB, L&T, EPCOS, SCHNEIDER, ELECTRONICON, BCH. (DETAILS AS IN ITEM BREAKUP)
ISI marked four core circular armoured cross linked polyethylene (XLPE) LT insulateed cable. PVC outer sheathed armoured with galvanised round steel wire or steel strip and with 7 aluminium conducter suitable for rated voltage 1100 volts, grade conforming to IS:7098 [part-1]- 1988 with admt. no. 1,2 and 3 [reaffirmed 2005] size 4*120 sq. mm. The firm will have to submit type test report as per IS from NABl accredited lab alongwith the tender. Type test report should not be more than 10 years old on the date of bid opening.
ISI marked four core circular armoured cross linked polyethylene (XLPE) LT insulateed 8 cable. PVC outer sheathed armoured with galvanised round steel wire or steel strip and with aluminium conducter suitable for rated voltage 1100 volts, grade conforming to IS:7098 [part-1]- 1988 with admt. no. 1,2 and 3 [reaffirmed 2005] size 4*95 sq. mm. The firm will have to submit type test report as per IS from NABl accredited lab alongwith the tender. Type test report should not be more than 10 years old on the date of bid opening.
Laying and fixing PVC/XLPE cables of different sizes ranging from 25 sq mm to 120 sq mm on surface of the wall (normally concealed)/steel structure as per the requirement of site with proper clamping arrangement as required at every 1/2 metre.
Supply, laying, connecting & commissioning of 50x6mm /40x5mm /25x6mm thick GI Strip for earth pit/pole/other electrical equipments with supply of required fasteners as per the directions of engineer at site
Item Breakup - PT -Part-B (Provision of APFC Panel at various pump houses over Dhanbad division)
(1) APFC RELAY : The automatic power factor Set controller shall be 8 stage type i.e. capable of connecting & disconnecting 4 nos. capacitors of 5KVAr rating, 2 nos. capacitors of 15KVAr and 2 Nos. of capacitors of 25KVAr . The power factor controller shall be flush mounted type with rear plug-in connectors. The APFC must incorporate digital display for the following: (a) Power factor (Phase by phase & average of 3 phases ), (b) Cos (Phi) ( Phase by phase & average of 3 phases ), (c) Accommodated Phase to neutral & Phase to Phase voltages of the system. (d) 3-phase current, (e) 3- phase active power, (f) Total active power, (g) 3- phase reactive power, (h) Total reactive power, (i) 3- Phase apparent power, (j) Total apparent power, Make: L&T, GE POWER, SIEMENS, ABB, SCHNEIDER, EPCOS, BELUK, CLARIANT (2.) MCCB 250 AMPS. : The 250A MCCB, TP type shall have adjustable thermal setting from 63% to 100 % & magnetic setting adjustable from 5 to 10 times with breaking capacity Icu= 50 KA. At 415V, 50Hz. 3 phase AC supply with rated current 250 Amps. Conforming to IS : 13947-2 complete with all accessories. (3.) MCB 50/63 Amps , 08 Nos. : The MCB shall be TP type C -class with breaking capacity ,10 KA & normal rating 50/63 Amps. Suitable for operation with 415V, 50Hz AC supply conforming to IS 8828. Make of MCCB/MCB: SIEMENS, SCHNEIDER, HAVELLS, GE, STANDARD, INDOASIAN, CONTROL & SWITCHGEAR, LEGRAND, HPL, HAGER. (4.)Power Contactor 65 Amps , 08 Nos. : 3 pole AC contactor with AC3 rating of 65 Amps with one NO & one NC auxiliary contact suitable for operation with 3 phase, 50Hz, 415V AC supply. Make: L & T, SIEMENS, ABB, GE POWER , BCH, C&S, TC, EATON, MITSUBISHI, ROCKWELL. (5.) Aluminium Bus-bar : Three nos. of phase bars of cross section 40 cm. x 10 cm. of length approximately 1.5 Mtrs. Each & one neutral bar of 40cm x 5 cm of length 0.5 Mtr. For connection of relays. (6.) ENCLOSURE: The enclosure shall be made of sheet steel, perfectly powder painted with thickness 16 SWG of approximate size 1.5 M x 1.3 M x 0.6 M (7.) ACCESSORIES: Ampere Meter, Voltmeter, Ampere meter Selector Switch, Voltmeter Selector Switch, Indicating lamp LED type, Fuse button, Control fuse, Current transformers, Supporting insulators, Bus bar sleeve wire, Lugs & other control. Accessories shall be of reputed make with ISI/ISO 9001 certification. The panel shall contain one vertical compartment in the middle for bus bar . Both sides of the bus-bar compartment shall be divided into 5 compartments each (total 10 smaller compartments) .The top most compartments on both sides shall be larger in size , the left compartment shall carry the 250 Amps MCCB & the right compartment the APFC . Total 8 compartments in both side are meant for 4 nos. capacitors of 5KVAr rating, 2 nos. capacitors of 15KVAr and 2 Nos. of capacitors of 25KVAr . Each compartment shall carry one ON & one OFF switch for manual operation with LED indicator for ON & OFF . Each capacitor shall be connected to the panel through one 65 Amps. Contactor & one 50/63 Amps TP MCB . Two compartments shall be without any capacitor Total 110027.69 DHANBAD DIVISION-ELECTRICAL/EAST CENTRAL RLY Supply & fixing of 90 KVAR APFC Panel Board made up of 1.6mm/1.8mm CRCA Sheet duly powder coated with Siemens grey RAL 7032/7035 with locking arrangements, Dust & Vermin proof, aluminium Busbar with color coded sleeves Indicating Lamps with control fuses, APFC relay 8stage. (Without Reactor). The automatic power factor controller panel 90 KVAr (approximately) capacity shall incorporate microprocessor based digital controller with provision for manual control when the APFC relay fails. During normal automatic operation the microprocessor-controlled relays shall 'pick out' the correct capacitor size by referring to the actual demand of reactive power directly and do Item- 3 the correct 'C/k' adjustment automatically. The controller should be capable of maintaining power factor at 0.99 lagging to unity power factor. Component wise details for major components are as given below: Configuration: 90 KVAR APFC Panel, 8stage: (4x5KVAr)+(1x10KVAr) +( 3x20KVAr), Capacitor must be Metallic poly propylene (MPP) type heavy duty , delta connected power capacitors suitable for operation with 415 volt , 3 phase , 50 Hz. AC supply with in-built discharge resistance. Make: SIEMENS, GE POWER, ABB, L&T, EPCOS, SCHNEIDER, ELECTRONICON, BCH (DETAILS AS IN ITEM BREAKUP) S No. Item Description of Item Unit Qty Rate Amount No DHANBAD DIVISION-ELECTRICAL/EAST CENTRAL RLY
(1) APFC RELAY : The automatic power factor Set controller shall be 8 stage type i.e. capable of connecting & disconnecting 4 nos. capacitors of 5KVAr rating, 1 nos. capacitors of 10KVAr and 3 Nos. of capacitors of 20KVAr . The power factor controller shall be flush mounted type with rear plug-in connectors. The APFC must incorporate digital display for the following: (a) Power factor (Phase by phase & average of 3 phases ), (b) Cos (Phi) ( Phase by phase & average of 3 phases ), (c) Accommodated Phase to neutral & Phase to Phase voltages of the system. (d) 3-phase current, (e) 3- phase active power, (f) Total active power, (g) 3- phase reactive power, (h) Total reactive power, (i) 3- Phase apparent power, (j) Total apparent power, Make: L&T, GE POWER, SIEMENS, ABB, SCHNEIDER, EPCOS, BELUK, CLARIANT (2.) MCCB 250 AMPS. : The 250A MCCB, TP type shall have adjustable thermal setting from 63% to 100 % & magnetic setting adjustable from 5 to 10 times with breaking capacity Icu= 50 KA. At 415V, 50Hz. 3 phase AC supply with rated current 250 Amps. Conforming to IS : 13947-2 complete with all accessories. (3.) MCB 40 Amps , 08 Nos. : The MCB shall be TP type C -class with breaking capacity ,10 KA & normal rating 40 Amps. Suitable for operation with 415V, 50Hz AC supply conforming to IS 8828. Make of MCCB/MCB: SIEMENS, SCHNEIDER, HAVELLS, GE, STANDARD, INDOASIAN, CONTROL & SWITCHGEAR, LEGRAND, HPL, HAGER. (4.)Power Contactor 50 Amps , 08 Nos. : 3 pole AC contactor with AC3 rating of 50 Amps with one NO & one NC auxiliary contact suitable for operation with 3 phase, 50Hz, 415V AC supply. Make: L & T, SIEMENS, ABB, GE POWER , BCH, C&S, TC, EATON, MITSUBISHI, ROCKWELL. (5.) Aluminium Bus-bar : Three nos. of phase bars of cross section 40 cm. x 10 cm. of length approximately 1.5 Mtrs. Each & one neutral bar of 40cm x 5 cm of length 0.5 Mtr. For connection of relays. (6.) ENCLOSURE: The enclosure shall be made of sheet steel, perfectly powder painted with thickness 16 SWG of approximate size 1.5 M x 1.3 M x 0.6 M (7.) ACCESSORIES: Ampere Meter, Voltmeter, Ampere meter Selector Switch, Voltmeter Selector Switch, Indicating lamp LED type, Fuse button, Control fuse, Current transformers, Supporting insulators, Bus bar sleeve wire, Lugs & other control. Accessories shall be of reputed make with ISI/ISO 9001 certification. The panel shall contain one vertical compartment in the middle for bus bar . Both sides of the bus-bar compartment shall be divided into 5 compartments each (total 10 smaller compartments) .The top most compartments on both sides shall be larger in size , the left compartment shall carry the 250 Amps MCCB & the right compartment the APFC . Total 8 compartments in both side are meant for 4 nos. capacitors of 5KVAr rating, 1 nos. capacitors of 10KVAr and 3 Nos. of capacitors of 20 KVAr . Each compartment shall carry one ON & one OFF switch for manual operation with LED indicator for ON & OFF . Each capacitor shall be connected to the panel through one 50 Amps. Contactor & one 40 Amps TP MCB . Two compartments shall be without any capacitor Total 299135.79 DHANBAD DIVISION-ELECTRICAL/EAST CENTRAL RLY Supply & fixing of 50 KVAR APFC Panel Board made up of 1.6mm/1.8mm CRCA Sheet duly powder coated with Siemens grey RAL 7032/7035 with locking arrangements, Dust & Vermin proof, aluminium Busbar with color coded sleeves Indicating Lamps with control fuses, APFC relay 8stage. (Without Reactor). The automatic power factor controller panel 50 KVAr (approximately) capacity shall incorporate microprocessor based digital controller with provision for manual control when the APFC relay fails. During normal automatic operation the microprocessor-controlled relays shall 'pick out' the correct capacitor size by referring to the actual demand of reactive power directly and do Item- 4 the correct 'C/k' adjustment automatically. The controller should be capable of maintaining power factor at 0.99 lagging to unity power factor. Component wise details for major components are as given below: Configuration: 50 KVAR APFC Panel, 6stage: (4x5KVAr) + (1x10KVAr) +(1x20KVAr), Capacitor must be Metallic poly propylene (MPP) type heavy duty , delta connected power capacitors suitable for operation with 415 volt , 3 phase , 50 Hz. AC supply with in-built discharge resistance. Make: SIEMENS, GE POWER, ABB, L&T, EPCOS, SCHNEIDER, ELECTRONICON. (DETAILS AS IN ITEM BREAKUP) S No. Item Description of Item Unit Qty Rate Amount No DHANBAD DIVISION-ELECTRICAL/EAST CENTRAL RLY
(1) APFC RELAY : The automatic power factor Set controller shall be 6 stage type i.e. capable of connecting & disconnecting 4 nos. capacitors of 5KVAr rating, 1 nos. capacitors of 10KVAr and 1 Nos. of capacitors of 20KVAr . The power factor controller shall be flush mounted type with rear plug-in connectors. The APFC must incorporate digital display for the following: (a) Power factor (Phase by phase & average of 3 phases ), (b) Cos (Phi) ( Phase by phase & average of 3 phases ), (c) Accommodated Phase to neutral & Phase to Phase voltages of the system. (d) 3-phase current, (e) 3- phase active power, (f) Total active power, (g) 3- phase reactive power, (h) Total reactive power, (i) 3- Phase apparent power, (j) Total apparent power, Make: L&T, GE POWER, SIEMENS, ABB, SCHNEIDER, EPCOS, BELUK, CLARIANT (2.) MCCB 125 AMPS. : The 125A MCCB, TP type shall have adjustable thermal setting from 63% to 100 % & magnetic setting adjustable from 5 to 10 times with breaking capacity Icu= 50 KA. At 415V, 50Hz. 3 phase AC supply with rated current 125 Amps. Conforming to IS : 13947-2 complete with all accessories. (3.) MCB 32 Amps , 06 Nos. : The MCB shall be TP type C -class with breaking capacity ,10 KA & normal rating 32 Amps. Suitable for operation with 415V, 50Hz AC supply conforming to IS 8828. Make of MCCB/MCB: SIEMENS, SCHNEIDER, HAVELLS, GE, STANDARD, INDOASIAN, CONTROL & SWITCHGEAR, LEGRAND, HPL, HAGER. (4.)Power Contactor 40 Amps , 06 Nos. : 3 pole AC contactor with AC3 rating of 40 Amps with one NO & one NC auxiliary contact suitable for operation with 3 phase, 50Hz, 415V AC supply. Make: L & T, SIEMENS, ABB, GE POWER , BCH, C&S, TC, EATON, MITSUBISHI, ROCKWELL. (5.) Aluminium Bus-bar : Three nos. of phase bars of cross section 40 cm. x 10 cm. of length approximately 1.5 Mtrs. Each & one neutral bar of 40cm x 5 cm of length 0.5 Mtr. For connection of relays. (6.) ENCLOSURE: The enclosure shall be made of sheet steel, perfectly powder painted with thickness 16 SWG of approximate size 1.5 M x 1.2 M x 0.6 M (7.) ACCESSORIES: Ampere Meter, Voltmeter, Ampere meter Selector Switch, Voltmeter Selector Switch, Indicating lamp LED type, Fuse button, Control fuse, Current transformers, Supporting insulators, Bus bar sleeve wire, Lugs & other control. Accessories shall be of reputed make with ISI/ISO 9001 certification. The panel shall contain one vertical compartment in the middle for bus bar . Both sides of the bus-bar compartment shall be divided into 4 compartments each (total 8 smaller compartments).The topmost compartments on both sides shall be larger in size , the left compartment shall carry the 125 Amps MCCB & the right compartment the APFC . Total 6 compartments in both side are meant for 4 nos. capacitors of 5KVAr rating, 1 Nos. capacitor of 10KVAr and 1 Nos. capacitor of 20KVAr rating . Each compartment shall carry one ON & one OFF switch for manual operation with LED indicator for ON & OFF . Each capacitor shall be connected to the panel through one 40Amps. Contactor & one 32Amps TP MCB . Two compartments shall be without any capacitor Total 284317.85 DHANBAD DIVISION-ELECTRICAL/EAST CENTRAL RLY Supply & fixing of 25 KVAR APFC Panel Board made up of 1.6mm/1.8mm CRCA Sheet duly powder coated with Siemens grey RAL 7032/7035 with locking arrangements, Dust & Vermin proof, aluminium Busbar with color coded sleeves Indicating Lamps with control fuses, APFC relay 8stage. (Without Reactor). The automatic power factor controller panel 25 KVAr (approximately) capacity shall incorporate microprocessor based digital controller with provision for manual control when the APFC relay fails. During normal automatic operation the microprocessor-controlled relays shall 'pick out' the correct capacitor size by referring to the actual demand of reactive power directly and do Item- 5 the correct 'C/k' adjustment automatically. The controller should be capable of maintaining power factor at 0.99 lagging to unity power factor. Component wise details for major components are as given below: Configuration: 25 KVAR APFC Panel, 4stage: (3x5KVAr) + (1x10KVAr), Capacitor must be Metallic poly propylene (MPP) type heavy duty , delta connected power capacitors suitable for operation with 415 volt , 3 phase , 50 Hz. AC supply with in-built discharge resistance. Make: SIEMENS, GE POWER, ABB, L&T, EPCOS, SCHNEIDER, ELECTRONICON, BCH.(DETAILS AS IN ITEM BREAKUP) S No. Item Description of Item Unit Qty Rate Amount No DHANBAD DIVISION-ELECTRICAL/EAST CENTRAL RLY
(1) APFC RELAY : The automatic power factor Set controller shall be 4 stage type i.e. capable of connecting & disconnecting 3 nos. capacitors of 5KVAr rating and 1 Nos. of capacitors of 10KVAr . The power factor controller shall be flush mounted type with rear plug-in connectors. The APFC must incorporate digital display for the following: (a) Power factor (Phase by phase & average of 3 phases ), (b) Cos (Phi) ( Phase by phase & average of 3 phases ), (c) Accommodated Phase to neutral & Phase to Phase voltages of the system. (d) 3-phase current, (e) 3-phase active power, (f) Total active power, (g) 3-phase reactive power, (h) Total reactive power, (i) 3-Phase apparent power, (j) Total apparent power, Make: L&T, GE POWER, SIEMENS, ABB, SCHNEIDER, EPCOS, BELUK, CLARIANT (2.) MCCB 80 AMPS. : The 125A MCCB, TP type shall have adjustable thermal setting from 63% to 100 % & magnetic setting adjustable from 5 to 10 times with breaking capacity Icu= 50 KA. At 415V, 50Hz. 3 phase AC supply with rated current 80 Amps. Conforming to IS : 13947-2 complete with all accessories. (3.) MCB 25 Amps , 04 Nos. : The MCB shall be TP type C -class with breaking capacity ,10 KA & normal rating 25 Amps. Suitable for operation with 415V, 50Hz AC supply conforming to IS 8828. Make of MCCB/MCB: SIEMENS, SCHNEIDER, HAVELLS, GE, STANDARD, INDOASIAN, CONTROL & SWITCHGEAR, LEGRAND, HPL, HAGER. (4.)Power Contactor 32 Amps , 04 Nos. : 3 pole AC contactor with AC3 rating of 32 Amps with one NO & one NC auxiliary contact suitable for operation with 3 phase, 50Hz, 415V AC supply. Make: L & T, SIEMENS, ABB, GE POWER , BCH, C&S, TC, EATON, MITSUBISHI, ROCKWELL. (5.) Aluminium Bus-bar : Three nos. of phase bars of cross section 40 cm. x 10 cm. of length approximately 1.2 Mtrs. Each & one neutral bar of 40cm x 5 cm of length 0.5 Mtr. For connection of relays. (6.) ENCLOSURE: The enclosure shall be made of sheet steel, perfectly powder painted with thickness 16 SWG of approximate size 1.5 M x 1.0 M x 0.6 M (7.) ACCESSORIES: Ampere Meter, Voltmeter, Ampere meter Selector Switch, Voltmeter Selector Switch, Indicating lamp LED type, Fuse button, Control fuse, Current transformers, Supporting insulators, Bus bar sleeve wire, Lugs & other control. Accessories shall be of reputed make with ISI/ISO 9001 certification. The panel shall contain one vertical compartment in the middle for bus bar . Both sides of the bus-bar compartment shall be divided into 3 compartments each (total 6 smaller compartments)..The topmost compartments on both sides shall be larger in size , the left compartment shall carry the 80 Amps MCCB & the right compartment the APFC . Total 4 compartments in both side are meant for 3 nos. capacitors of 5KVAr rating & 1 Nos. capacitor of 10KVAr. Each compartment shall carry one ON & one OFF switch for manual operation with LED indicator for ON & OFF . Each capacitor shall be connected to the panel through one 32Amps. Contactor & one 25Amps or (6A-32A) TP MCB . Two compartments shall be without any capacitor. Total 219863.20 DHANBAD DIVISION-ELECTRICAL/EAST CENTRAL RLY Supply & fixing of 20 KVAR APFC Panel Board made up of 1.6mm/1.8mm CRCA Sheet duly powder coated with Siemens grey RAL 7032/7035 with locking arrangements, Dust & Vermin proof, aluminium Busbar with color coded sleeves Indicating Lamps with control fuses, APFC relay 8stage. (Without Reactor). The automatic power factor controller panel 20 KVAr (approximately) capacity shall incorporate microprocessor based digital controller with provision for manual control when the APFC relay fails. During normal automatic operation the microprocessor-controlled relays shall 'pick Item- 6 out' the correct capacitor size by referring to the actual demand of reactive power directly and do the correct 'C/k' adjustment automatically. The controller should be capable of maintaining power factor at 0.99 lagging to unity power factor. Component wise details for major components are as given below: Configuration: 20 KVAR APFC Panel, 4stage: (4x5KVAr), Capacitor must be Metallic poly propylene (MPP) type heavy duty , delta connected power capacitors suitable for operation with 415 volt , 3 phase , 50 Hz. AC supply with in-built discharge resistance. Make: SIEMENS, GE POWER, ABB, L&T, EPCOS, SCHNEIDER, ELECTRONICON, BCH. (DETAILS AS IN ITEM BREAKUP) S No. Item Description of Item Unit Qty Rate Amount No DHANBAD DIVISION-ELECTRICAL/EAST CENTRAL RLY
(1) APFC RELAY : The automatic power factor Set controller shall be 4 stage type i.e. capable of connecting & disconnecting 4 nos. capacitors of 5KVAr rating. The power factor controller shall be flush mounted type with rear plug-in connectors. The APFC must incorporate digital display for the following: (a) Power factor (Phase by phase & average of 3 phases ), (b) Cos (Phi) ( Phase by phase & average of 3 phases ), (c) Accommodated Phase to neutral & Phase to Phase voltages of the system. (d) 3-phase current, (e) 3-phase active power, (f) Total active power, (g) 3-phase reactive power, (h) Total reactive power, (i) 3-Phase apparent power, (j) Total apparent power, Make: L&T, GE POWER, SIEMENS, ABB, SCHNEIDER, EPCOS, BELUK, CLARIANT (2.) MCCB 63 AMPS. : The 125A MCCB, TP type shall have adjustable thermal setting from 63% to 100 % & magnetic setting adjustable from 5 to 10 times with breaking capacity Icu= 50 KA. At 415V, 50Hz. 3 phase AC supply with rated current 63 Amps. Conforming to IS : 13947-2 complete with all accessories. (3.) MCB 20 Amps , 04 Nos. : The MCB shall be TP type C -class with breaking capacity ,10 KA & normal rating 20 Amps. Suitable for operation with 415V, 50Hz AC supply conforming to IS 8828. Make of MCCB/MCB: SIEMENS, SCHNEIDER, HAVELLS, GE, STANDARD, INDOASIAN, CONTROL & SWITCHGEAR, LEGRAND, HPL, HAGER. (4.)Power Contactor 25 Amps , 04 Nos. : 3 pole AC contactor with AC3 rating of 25 Amps with one NO & one NC auxiliary contact suitable for operation with 3 phase, 50Hz, 415V AC supply. Make: L & T, SIEMENS, ABB, GE POWER , BCH, C&S, TC, EATON, MITSUBISHI, ROCKWELL. (5.) Aluminium Bus-bar : Three nos. of phase bars of cross section 40 cm. x 10 cm. of length approximately 1.2 Mtrs. Each & one neutral bar of 40cm x 5 cm of length 0.5 Mtr. For connection of relays. (6.) ENCLOSURE: The enclosure shall be made of sheet steel, perfectly powder painted with thickness 16 SWG of approximate size 1.5 M x 1.0 M x 0.6 M (7.) ACCESSORIES: Ampere Meter, Voltmeter, Ampere meter Selector Switch, Voltmeter Selector Switch, Indicating lamp LED type, Fuse button, Control fuse, Current transformers, Supporting insulators, Bus bar sleeve wire, Lugs & other control. Accessories shall be of reputed make with ISI/ISO 9001 certification. The panel shall contain one vertical compartment in the middle for bus bar . Both sides of the bus-bar compartment shall be divided into 3 compartments each (total 6 smaller compartments)..The topmost compartments on both sides shall be larger in size , the left compartment shall carry the 63 Amps MCCB & the right compartment the APFC . Total 4 compartments in both side are meant for 4 nos. capacitors of 5KVAr rating. Each compartment shall carry one ON & one OFF switch for manual operation with LED indicator for ON & OFF . Each capacitor shall be connected to the panel through one 25Amps. Contactor & one 20Amps or (6A-32A) TP MCB . Two compartments shall be without any capacitor. Total 150656.24
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .