Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC | ₹2.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.0 Cr+₹4.5 L (2.28%)Rejected-AOC | ₹2.0 Cr+₹4.5 L (2.28%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.0 Cr+₹8.1 L (4.12%)Rejected-AOC | ₹2.0 Cr+₹8.1 L (4.12%) | L3 | Rejected-AOC L3 |
Tender Value
₹2 Cr
EMD Value
₹2 L
Closing Date
6 Dec 2024, 4:00 pmClosed
MANAGING DIRECTOR
HEAD OFFICE ERCMPU EDAPPALLY
CIVIL WORKS NEW ICE CREAM PLANT BUILDING FOR PRODUCTS DAIRY UNDER ERCMPU
2024_KCMMF_706247_1
EU/PC/768/DIDF/2024-25/43
Open Tender
Civil Works - Others
Turn-key
120 days
PRODUCTS DAIRY EDAPPALLY
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹2 L
HEAD OFFICE ERCMPU
9 Apr 2025
16 Nov 2024
7 Dec 2024
16 Nov 2024
6 Dec 2024
16 Nov 2024
16 Nov 2024 - 6 Dec 2024
25 Nov 2024
E A R T H W O R K:-Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil 0.0m To 1.5 m
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials All kinds of soil - 1.5 - 3.0m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30
P.C.C CONCRETE :- Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Basement, below GF Flooring & entrance below area .
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
DESIGN MIX CONCRETE :-Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum
All works above plinth level upto 3rd floor level . Concrete of M40 grade with minimum cement content of 390 kg /cum
FORM WORK:-Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
REINFORCEMENT :- Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth all levels. a) Thermo-Mechanically Treated bars ( Fe - 500 ) - below plinth
b)Thermo-Mechanically Treated bars ( Fe - 500 ) - above plinth
MASONRY WORK :-Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 Newton per sqmm in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
JOINERY :-Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood (Frame Size - 100 x 75mm)
Providing and fixing 35 mm thick factory made laminated veneer lumber door shutter conforming to IS : 14616 and TADS 15:2001 (Part B), fixing with butt hinges of required size with necessary screws, all complete as per directions of Engineer- in-charge and panelling with panels of : (Note:- Butt hinges and necessary screws shall be paid separately) 12 mm thick one side Pre-laminated particle board (decorative lamination on one side and other sides balancing lamination) grade -1, medium density flat pressed, three layer particle board FPT - I or graded wood particle board FPT-1 conforming to IS : 3087 bonded with BWP type synthetic resin adhesive as per IS : 848 and pre-laminated conforming to IS : 12823, Grade -1, Type II marked :
HARDWARES :-Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing and fixing ISI marked, IS : 1341, M.S. heavy weight butt hinges with necessary screws etc. complete :125x90x4.00 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :250x10 mm
Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
S T E E L W O R K :-Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
STAINLESS STEEL :- Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). ( staircase and ramp )
FLOORING:- GRANO 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardene mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
GRANITE W O R K:- Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. ( Corridor/ dining)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement : 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.
F I N I S H I N G :- Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster ( Inner wall )
6 mm cement plaster of mix : ( Ceiling area ) 1:3 (1 cement : 3 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Extra for providing and mixing water proofing material in cement per bag of plaster work in proportion recommended by the manufacturers.
PAINTING :-Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC(Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Wall painting with acrylic emulsion paint (interior ) having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats
Painting with Synthetic enamel paint of approved brand and manufacture to given even shade
Providing and fixing in position precast R.C.C. manhole cover and frame.Square shape 450mm internal dimensions
Anti termite treatment measured in accordance with the BIS with guarantee for 10 years ( Tenderer to submit guarantee on stamp paper of adequate value as per proforma attached)
SINGLE ALUMINIUM GLAZED STILE DOOR WITH ALTERRA SYSTEM with Door Closer- ALT 50 : -Supply & Fixing of ALT 50 Aluminium Glazed Door (Double Leaf) with Glass infill of toughened/Laminated glass with Alterra rebate door frame System all around the door. Aluminium Stile to be formed out of 70x35mm Horizontal and Vertical Door Profile frame with clips & seals. Door Hardware -Flush Hinges ( 3 nos),Open Door Closer TS 70 With Slide Channel and Hold Open, Pure 8906 anti-microbial Lever Handle with Narrow stile Lock package and Door Drop down seal.Suitable for Glass thickness of 10/12/13.52mm.The Profile shall be matt natural anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 1.5 mm Gauge thickness Excluding 20 Micron of Anodizing.Max System Height - 3000mm
Providing, fabricating and fixing Powder coated Aluminium Fixed Windows made out of HINDALCO/ INDAL / JINDALor equivalent fabricated out of extruded sections 1.223Kg/m (12gauge frame & styles) confirming to BIS using sections / profile of specified size, shape and thickness with 20 micron anodizing including supplying and fixing necessary holding bolts / screws , handles, locking arrangement as per details, fixtures and fastenings of anodized aluminum as per requirement and 6 mm. Thk. Modiguard make tinted glass and imported beading shall be used with special gasket felt – EPDM gasket and aluminum beading, filling the gaps around the frame with white colour gun grade silicon sealant to ensure the joint water tight, complete as per drawing etc complete as directed by The engineer.
Providing and fixing Translucent, cast PVC, self-adhesive vinyl, special CRYSTAL- effect film to reproduce Sand-blasting effect on glass with customised designs. MCS warranty of 3 [if exposed to direct sunlight] to 15 years [indoors] endorsed by 3M India Limited, all as instructed by Engineer-in-charge.
Terrace WATERPROOFING Option 1 -Single Component Solvent Based PU Coating Surface Treatment: Providing and laying water proofing treatment of terrace including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout and preparation of surface in all aspects to receive the waterproofing. Bore Packing / Core Cut Treatment: Providing and sealing the gaps in the core cuts around PVC pipes treated with ReArm Bond SBR 45 bonding agent & sprinkled sand; using a non shrink grout ArmGrout M 50 or equivalent of followed by sealing of the same joint by using Joint Tape SealArm Joint Tape 2000 or equivalent with Epoxy adhesive. Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with ReArm Bond SBR 45 at dosage of 5 litre per 50kg cement. (cement and sand shall be supplied by the main contractor) Application of Primer: Apply Epoxy based primer FloArm Primer PUDC of MYK Arment or equivalent over well prepared surface at 200-400 gm per Sq.Mtr. Application of Polyurethane waterproof coating: Providing and applying Two coats of liquid applied single component polyurethane based waterproofing system AquaArm SPU-SPL of MYK Arment or equivalent . It has to be applied @1.95 kg/sqmtr to achieve a thickness of 1.2 mm in two coats.The membrane will have the following technical parameters: Tensile Strength : 2 N/mm2 ,. Elongation at break : 400% , Adhesion To concrete: >1.5 N/mm2, Providing and laying 150 Gsm Geo fabric membrane as separation layer
Proofing by Brick Bat Coba method using CICO NO.1 or other approved equivalent compound with cement mortar 1:3 as per specifications follows: The roof slab/gutter slab shall be throughly cleaned to remove debris and dust, and applying 2 coats of acylic polymer modified cement based, flexible water proofing slurry like Tapecrete or approved equivalent make compound and curede for 7 days followed by a layer of 20mm thick cement mortar 1:3 admixed with CICO NO.1 (or) other approved equivalent make shall be spread over the prepared surface. On the spread mortar provide and lay well burnt brick bat (COBA) to a average minimum thickness of 55mm ( i.e minimum 40mm thickness at lower end and 70mm thickness at higher end). An additional layer of brick bat ( COBA) shall be laid over the existing brick bat COBA surface if required to get the required gradient for adequate drainage giving a slope of approximately 1 in 100.
TERRACE SCREED :- Protection Screed: Horizontal Areas: Providing and Laying M25 grade screed concrete in 1:100 to a average thickness of 100 mm mixed with Integral Waterproofing admixture AquaArm Proof WP 10 at the dosage of 125 ml/bag of cement over waterproofing layer to a minimum thickness of 75 mm as per site requirement(Civil Contractor Scope) including control joints of 4M X 4M size and filling the panels with polyurethane sealant.
WATER TANKS :- Surface Preparation: Providing and laying water proofing treatment to horizontal and vertical surfaces of podium slabs, including cleaning the surface with wire brush, treating all surface cracks, construction joints and honeycombs by grouting with specialised non shrink grout,coving preparation at wall - slab joint and preparation of surface in all aspects to receive the waterproofing. Coving: Providing and Applying at the junction of slab and vertical offsets with Cement Mortar 1:4 and admixed with ReArm Bond SBR 45 at dosage of 4Ltr per 50kg cement. (cement and sand shall be supplied by the main contractor). Waterproofing Coating : -Providing and application of a two component, cementitious acrylic polymer based high performance water proofing coating Aquaarm 2C of MYK Arment or equivalent . It offers seamless coating applied@ 2Kg /Sqm for 1 mm DFT .Technical Data: Elongation : 80% Crack bridging : up to 1mm Tensile Strength : 0.4 N.mm2,Pull out bonding strength : 1.5 N mm2. Protective Plaster: providing and laying avg. 15 mm thick, CM 1:4 plaster admixed with Integral Waterproofing Compound Aquaarm Proof WP 10 of MYK Arment or equivalent @ 150 ml / bag of cement. (cement and sand shall be supplied by the main contractor) Food Grade epoxy coating-Application of food grade epoxy coating FloArm Coat ECW of MYK Arment or equivalent in Inner side of tank: providing and applying CFTRI Certified epoxy coating applied @ 0.600 kg/m2 in two coats. It will give 400 microns thickness.
Providing and fixing 20mm dia PVC coated MS Rungs @ 300C/C
JOSEPH GEORGE M (BID ID -1999945)
DELMANN CONSTRUCTIONS (BID ID -2001120)
DELMANN CONSTRUCTIONS
Ansar Ahmed
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .