Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹46.0 L+₹1.5 L (3.40%)Rejected-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L2 | Rejected-Finance Become L2 | |
| 3 | L3₹49.1 L+₹4.6 L (10.3%)Rejected-Finance CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L3 | Rejected-Finance Become L3 | |
| 4 | L4₹49.3 L+₹4.8 L (10.9%)Rejected-Finance | L4 | Rejected-Finance Become L4 | |
| 5 | L5₹49.8 L+₹5.3 L (11.9%)Rejected-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L5 | Rejected-Finance Become L5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
4 Jul 2022, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali Tezpur, Assam
Repair/Maint of DG Set with AMF Panel at Zone 5 and Zone 1 (A,B,C) and DG Set with AMF Panel and allied works at Zone 1,3 (A,B),Zone 2 and Zone 4 under GE (S) Tezpur
2022_MES_530900_1
8669
Open Tender
Civil Works
Item Rate
240 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹90,000
Yes
8 Sept 2022
14 Jun 2022
6 Jul 2022
14 Jun 2022
4 Jul 2022
27 Jun 2022
Amount
Maint and servicing of DG set 380-400 KVA conopy type with AMF Panel , through authorise service agency of OEM , including replacment of defective/wornout parts with new spares such as filters, gaskets, V belts, Engine Oil, coolant for radiator rubber hoses with clamps, nuts bolts and cleaning of alternator with vaccum cleaner , including greasing of bearings of engine and alternator, tappet setting, checking of batteries, adding distilled water and cleaning of POL tank and radiator etc including painting a coat of syanthetic enamel painting after surface preparation, all as specified and directed. Make - Kirloskar/cummins/greaves/Ashok Leyland / As per OEM Note:- 1. spares required for above maint will be measured and paid separately under relevent items of Schedule. 2. All breakdown calls should be attended. 3. Scheduled system check up visits should be done periodically. 4. Major spare parts required is paid separately under separate items. 5. The repair/servicing of DG set shall be carried out through the authorised working party (agency) of the OEM with prior permission of GE with MOU as applicable.
All as per Item No-1 Above but for DG set of capacity 320 KVA
All as per Item No-1 Above but for DG set of capacity 200-250 KVA
All as per Item No-1 Above but for DG set of capacity 125-160 KVA
All as per Item No-1 Above but for DG set of capacity 25-100 KVA
S & F in repair Fuel filter for 380-400 KVA DG set, Make : As per OEM
S & F in repair Fuel filter for 320 KVA DG set,Make : As Per OEM
S & F in repair Fuel filter for 200-250 KVA DG set,Make : As Per OEM
S & F in repair Fuel filter for 125-160 KVA DG set,Make : As Per OEM.
S & F in repair Fuel filter for 25- 100 KVA DG set,Make : As Per OEM
S & F in repair Lub oil filter for 380-400 KVA DG set,Make : As Per OEM.
S & F in repair Lub oil filter for 320 KVA DG set,Make : As Per OEM
S & F in repair Lub oil filter for 200-250 KVA DG set,Make : As Per OEM
S & F in repair Lub oil filter for 125-160 KVA DG set,Make : As Per OEM
S & F in repair Lub oil filter for 25-100 KVA DG set,Make : As Per OEM
S & F in repair Air cleaner filter ( inner and outer ) for 380-400 KVA DG set, Make : As Per OEM.
S & F in repair Air cleaner filter (inner and outer ) for 320 KVA DG set, Make : As Per OEM.
S & F in repair Air cleaner filter (inner and outer ) for 200-250 KVA DG set, Make : As Per OEM
S & F in repair Air cleaner filter(inner and outer) for 125-160 KVA DG set, Make : As Per OEM
S & F in repair Air cleaner filter (inner and outer ) for 25-100 KVA DG set, Make : As Per OEM
S & F in repair Bypass filter for 380-400 KVA DG set,Make : As Per OEM.
S & F in repair Bypass filter for 320 KVA DG set,Make : As Per OEM
S & F in repair Bypass filter for 200-250 KVA DG set,Make :As Per OEM
S & F in repair Bypass filter for 125-160 KVA DG set,Make : As Per OEM
S & F in repair Bypass filter for less tha 100 KVA DG set,Make : As Per OEM
S & F in repair V belt for 380-400 KVA DG set, Make : As Per OEM
S & F in repair V belt for 320 KVA DG set, Make : As Per OEM
S & F in repair V belt for 200-250 KVA DG set, Make : As Per OEM
S & F in repair V belt for 125-160 KVA DG set, Make : As Per OEM
S & F in repair V belt for less than 100 KVA DG set, Make : As Per OEM
S & F in repair Display control panel (LED Board) for 25 to 400kva DG set,Make : As Per OEM.
S & F in repair Fuel actuator with O Ring for 25 to 400kva DG set,Make : As Per OEM
S & F in repair Key switch for 25 to 400kva DG set,Make : As Per OEM
S & F in repair coolant temperature sensor (coolent control safety) for 25 to 400kva DG set,Make : As Per OEM
S & F in repair AMF controller assy for auto/manual operation for 25 to 400kva DG set,Make : As Per OEM
S & F in repair Control assy main generator panel for 25 -400 KVA DG set having microprocessor unit for controlling coolant temperature, fuel injection, oil pressure, governor etc complete.
S & F in repair Lube oil pressure sensor adaptor (oil control safety ) 25 to 400kva DG set,Make : As Per OEM
M&L for top overhaulling of engine 320 KVA Make:- Cummins.with the following Spare Parts:- (a) Seal O ring - 02 Nos (b) Core Cooler - 01 No (c) Kit-Barrel Plunger & Cap - 06 (d) Head, Cylinder - 01 Nos (e) Gasket Oil Pan - 01 No (f) Gasket Turbo Charger - 01 No (g) Clamp -T bolt - 02 Nos (h) Belt V-Ribbed (h) Hose, Plain - 04 Nos (j) Seal triangular ring - 03 Nos (k) Screen - 01 No (l) Thermostat - 01 No (m) Clamp, Hose - 04 Nos (n) Seal O ring - 01 No (o) Kit, Seal - 01 No (p) Upper engine gasket set - 01 No (q) Gasket Governor set - 01 No (r) Bearing, ball - 01 No (s) Seal 'O' ring (40169330) - 18 (t) Diaphragm, Fuel pump damper - 01 No (u) Washer sealing - 01 No (v) Gasket, oil suc connection - 03 Nos (w) Ball check - 06 Nos (x) Shaft fuel pump drive - 01 No (y) Shaft Techometer drive - 01 No (z) Bearing connecting rod - 12 Nos (z) Crank Shaft bearings (aa) Spring compression - 01 No (ab) Gasket, fuel pump - 01 No (ac) Screen filter - 06 Nos (ad) Ring liner seal - 06 Nos (ae) Plug injector orifice - 06 Nos (af) Spider jaw coupling - 01 No (ag) Hub, Jaw coupling - 01 No (ah) Key square - 01 No (ai) Retainer screen - 06 Nos (aj) Kit Piston and ring set - 01 No (ak) Kit Cylinder head NTBC repair - 02 No (al) Governor Barrel & Plunger - 01 No (am) Kit, Turbo repair HT 4B - 01 No (an) Liner, Cylinder - 01 No (ao) Rod Push - 18 Nos (ap) Screw cross head Adjusting - 12 Nos (aq) Nut, heavy Hexagonal - 12 Nos (ar) Delivery charges - LS (as) Service charges - LS (at) Reassemble all parts and testing complete including a coat of syathetic enamel painting after surface preparation, all as directed.
S & F in repair Stop solenoid switch 12 Volts . Make As Per OEM
S & F in repair Stop solenoid switch 24 Volts. Make- As Per OEM
Supply & Fill Coolant for radiators complete all as specified and directed. Make- As Per OEM
S & F in repair Turbo charger for any capacity DG set complete all as specified. Make- As Per OEM
Supply & Fill engine oil multi grade 15W40 all as specified and directed. (Make ELF Oil/ Castrol /HP or equivalent of OEM make)
S & F in repair Automatic Voltage Regulator fit for DG set of any make and any capacity complete all as specified. Make- As Per OEM
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set up to and including 100 KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set 125- 160KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Calibration of FIP and fuel injector from the authorised dealer including petty repairs to make the FIP and injectors functional for the following capacities of DG set 250/320/380/400KVA (Certificate to this effect that calibration and repair is carried out by authorised delear will be submitted by the contractor) all as specified and directed.
Disconnecting the electric connection of Alternator of capacity 250/320/380/400 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.
Disconnecting the electric connection of Alternator of capacity125/160 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.
Disconnecting the electric connection of Alternator of capacity 62.5/75/100 KVA DG set ,taking the accumalator and cleaning the core assembly through air blower,heat varnishing with insulating material complete all as directed.
S & F in repair Lub Oil cooler plate complete all as specified Make- As Per OEM
S & F in repair Lub Oil pressure gauge pipe of required standard size complete all as specified Make- As Per OEM
S & F in repair Oil spray nozzle assembly complete all as specified Make- As Per OEM
S & F in repair Piston assembly complete all as specified Make- As Per OEM
S & F in repair Main Bearing of various sizes for DG set of different capacity complete all as specified Make- As Per OEM
S & F in repair Water temp switch complete all as specified Make- As Per OEM
S & F in repair Lub Oil pump high discharge of required standard size complete all as specified Make- As Per OEM
S & F in repair of field coil assembly for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of Eye bolt for 25-400 KVA DG set,Make- As Per OEM.
S & F in repair of fan key for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of fan assembly for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of fan for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of Circlip for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of DE Bearing for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of Brush holder spindle for 25-400 KVA DG set,Make- As Per OEM
S & F in repair of NDE bearing cap for125/100/75/62.5kva DG set,Make- As Per OEM
S & F in repair of Slipring assembly for 25-125 KVA DG set Make- As Per OEM.
S & F in repair of Exicitation (CX) unit for 25-125 KVA DG set, Make- As Per OEM
S & F in repair of Slipring assembly for 160 - 250kva DG set,Make- As Per OEM.
S & F in repair of Exicitation (CX) unit for 160 - 250kva DG set,Make- As Per OEM
S & F in repair of Exicitation (CX) unit for 320-400 kva DG set,Make- As Per OEM.
S & F in repair of Slipring assembly for 320-400 kva DG set,Make- As Per OEM
Supply and fix in repair Battery terminal made with brass for 12/24 volt battery complete all as specified and directed.
Taking down unserviceable battery and supply and fixing 12 volt, 180 AH battery complete all as specified and directed.
Material and labour for cleaning external surface with cleaning agent including cleaning of radiators coil with with mild acid (or caustic soda) and cleaning of fuel tank etc of the following capacities complete including writing SM/MES nos on DG set size of letter not less than 50mm x 50mm of capacity 100/125/160/250/320/400 KVA including a coat of syathetic enamel painting, all as directed.
S & F in repair self starter 24 volt dc complete all as specified. Make- As Per OEM
S & F in repair self starter 12 volt dc complete all as specified. Make- As Per OEM
Repair, transporting, taking down and servicing of self starter 12/24 volt dc at authorised service centre including refixing the same and testing complete as directed
Maintanence and serviceing the AMF panel and replace the unserviceable items and testing and replace unserviceable wiring connection in panel for autometic operation through relay, contactor, timer, sensor etc all as directed
S & F in repair including painting one coat with syathetic enamel painting after surface preparation of Digital multi function meter suitable for AMF panel Make- As Per OEM
S & F in repair of indicator lamp (R,Y & B) suitable for AMF panel Make :- L&T or as approved by GE.
S & F in repair of three pole power contractor type MNX-250 with Aux contracts 2 Nos 2 NC , suitable for AMF panel complete.Make :- L&T or as approved by GE.
S & F in repair of three pole power contractor type MNX-300 with Aux contracts 2 Nos 2 NC , suitable for AMF panel complete.Make :- L&T or as approved by GE.
S & F in repair of three pole power contractor type MNX-550 with Aux contracts 2 Nos 2 NC , suitable for AMF panel complete.Make :- L&T or as approved by GE.
S & F in repair of AC Control contactor - M00AC - 15 4A at 415 Volt suitable for AMF panel complete.Make :- L&T or as approved by GE.
S & F in repair of DC control contactor M00AC 15 4A at 415 vilt suitable for AMF panel complete.Make :- L&T or as approved by GE. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
M/S BHAGWATI CONSTRUCTION CO.
MAHANTA ENTERPRISES
M/S BORNIL ENTERPRISE
Anil Kumar Sarmah
M/S Manjit Singh
M/S Bharat Construction Co.
D G Corporation
M/S MOHANPASARI
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .