| Sl No | Description | Qty | Unit | M/S VENUS BUILDER L1 | SARASWATI ELECTRIC STORE L3 | CHAHAR ENGINEERS AND COMPANY L4 | Surendra Singh L6 | M/s R K Enterprises L5 | SNEH CORPORATION L2 | Rajesh Enterprises L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S & F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one number of MCB SPN as incoming and 6 number of MCB SP as out going, SPN 8 way complete including dismentaling of unservceable existing DB complete all as specified and directed. | 60 | Each | 1,650 ₹99,000 | 1,800 ₹1,08,000 | 1,725 ₹1,03,500 | 2,000 ₹1,20,000 | 1,500 ₹90,000 | 1,245 ₹74,700 Lowest | 1,300 ₹78,000 |
| 2.00 | S & F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one number MCB SPN as incoming and 10 number MCB SP as out going,SPN 12 way complete including dismentaling of unservceable existing DB complete all as specified and directed. | 45 | Each | 2,000 ₹90,000 | 2,300 ₹1,03,500 | 2,250 ₹1,01,250 | 2,500 ₹1,12,500 | 1,700 ₹76,500 | 1,605 ₹72,225 | 1,600 ₹72,000 Lowest |
| 3.00 | S & F for sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for one No 63 to 100 Amp, breaking capacity 10 KA ,TPN MCCB as incoming complete including dismentaling of existing unservceable DB complete all as specified and directed by Engr-in-charge. | 42 | Each | 2,500 ₹1,05,000 Lowest | 3,100 ₹1,30,200 | 3,800 ₹1,59,600 | 3,300 ₹1,38,600 | 2,700 ₹1,13,400 | 2,685 ₹1,12,770 | 3,000 ₹1,26,000 |
| 4.00 | S & F for 6-32 Amps ISI marked MCB 240V,, Single pole "B" series and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB SP complete all as specified and directed by Engr-in-charge. | 670 | Each | 120 ₹80,400 Lowest | 180 ₹1,20,600 | 160 ₹1,07,200 | 200 ₹1,34,000 | 135 ₹90,450 | 140 ₹93,800 | 150 ₹1,00,500 |
| 5.00 | S & F for MCB Single pole & neutral "C" series upto 63. Amps ISI marked and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB SPN complete all as specified and directed by Engr-in-charge. | 150 | Each | 550 ₹82,500 | 550 ₹82,500 | 470 ₹70,500 Lowest | 800 ₹1,20,000 | 550 ₹82,500 | 528 ₹79,200 | 1,000 ₹1,50,000 |
| 6.00 | S & F for MCB Single pole & neutral "C" series 100 Amps ISI marked and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB SPN complete all as specified and directed by Engr-in-charge. | 20 | Each | 1,000 ₹20,000 | 800 ₹16,000 | 990 ₹19,800 | 1,500 ₹30,000 | 750 ₹15,000 Lowest | 1,050 ₹21,000 | 800 ₹16,000 |
| 7.00 | S & F for MCB TPN "C" Curve , 63 Amps, 415V, ISI marked and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB TPN complete all as specified and directed by Engr-in-charge. | 60 | Each | 850 ₹51,000 Lowest | 1,200 ₹72,000 | 1,310 ₹78,600 | 1,250 ₹75,000 | 1,350 ₹81,000 | 995 ₹59,700 | 1,500 ₹90,000 |
| 8.00 | S & F for MCB TP "C" Curve, 63 Amps, 415 V, ISI marked and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB TP complete all as specified and directed by Engr-in-charge. | 40 | Each | 850 ₹34,000 Lowest | 900 ₹36,000 | 1,190 ₹47,600 | 999 ₹39,960 | 900 ₹36,000 | 910 ₹36,400 | 1,300 ₹52,000 |
| 9.00 | M & L Sub main wiring with four runs of single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 25 mm dia/ appropriate dia with accessories & fittings,fixed on surface of wall ,ceiling etc., complete and making good disturbed surface of wall,ceiling etc., including taking down old UNSV existing submain wiring complete all as specified and as directed.
Note : - Four runs of 6.0Sqmm cable and one run of earth wire 6.0 Sqmm & conduit shall be measured as one unit length and extra length of cable required for connection to MCBs shall be deemed to be include in unit rate quoted by bidder. | 250 | RM | 260 ₹65,000 Lowest | 600 ₹1,50,000 | 571 ₹1,42,750 | 450 ₹1,12,500 | 540 ₹1,35,000 | 368 ₹92,000 | 580 ₹1,45,000 |
| 10.00 | M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh, charcoal & salt, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally & angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including taking down old UNSV existing earthing & making good disturbed surface complete all as specified and as directed.
Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre.
(ii) Earth filling shall be done by vegetable soil.
(iii) Soil should be free from stone, boulders, aggregate, gravels etc. | 26 | Each Job | 3,000 ₹78,000 Lowest | 3,500 ₹91,000 | 3,600 ₹93,600 | 3,500 ₹91,000 | 3,700 ₹96,200 | 3,300 ₹85,800 | 3,000 ₹78,000 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Jul 2026, 6:00 pmClosed
GE ARMY NO. 1 JODHPUR
GE ARMY NO. 1 MULTAN LINES ARMY AREA JODHPUR
REPAIR REPLACEMENT OF SUB MAIN WIRING, EARTHING TPN DBs AND LOAD BALANCING UNDER GE ARMY No.1 JODHPUR
2026_MES_763217_2
GE/JODH (A) No 1 OF 2026-27 (9420/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Jodhpur
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE ARMY NO. 1
₹80,000
Yes
11 Aug 2026
29 Jun 2026
27 Jul 2026
29 Jun 2026
20 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | S & F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one number of MCB SPN as incoming and 6 number of MCB SP as out going, SPN 8 way complete including dismentaling of unservceable existing DB complete all as specified and directed. | 60 | Each | 31,00,000 | ₹18,60,00,000 |
| - | S & F in replacement sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one number MCB SPN as incoming and 10 number MCB SP as out going,SPN 12 way complete including dismentaling of unservceable existing DB complete all as specified and directed. | 45 | Each | 31,00,000 | ₹13,95,00,000 |
| - | S & F for sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for one No 63 to 100 Amp, breaking capacity 10 KA ,TPN MCCB as incoming complete including dismentaling of existing unservceable DB complete all as specified and directed by Engr-in-charge. | 42 | Each | 31,00,000 | ₹13,02,00,000 |
| - | S & F for 6-32 Amps ISI marked MCB 240V,, Single pole "B" series and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB SP complete all as specified and directed by Engr-in-charge. | 670 | Each | 31,00,000 | ₹2,07,70,00,000 |
| - | S & F for MCB Single pole & neutral "C" series upto 63. Amps ISI marked and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB SPN complete all as specified and directed by Engr-in-charge. | 150 | Each | 31,00,000 | ₹46,50,00,000 |
| - | S & F for MCB Single pole & neutral "C" series 100 Amps ISI marked and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB SPN complete all as specified and directed by Engr-in-charge. | 20 | Each | 31,00,000 | ₹6,20,00,000 |
| - | S & F for MCB TPN "C" Curve , 63 Amps, 415V, ISI marked and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB TPN complete all as specified and directed by Engr-in-charge. | 60 | Each | 31,00,000 | ₹18,60,00,000 |
| - | S & F for MCB TP "C" Curve, 63 Amps, 415 V, ISI marked and current carrying capacity 10KA including dismantaling of old unserviceable existing MCB TP complete all as specified and directed by Engr-in-charge. | 40 | Each | 31,00,000 | ₹12,40,00,000 |
| - | M & L Sub main wiring with four runs of single core 6.0 Sqmm PVC insulated FRLSH multistanderd copper conductor cable and one run of 6.0 Sqmm PVC insulated unsheathed FRLSH multi stranded copper conductor cable for earth wire drawn in & including rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 25 mm dia/ appropriate dia with accessories & fittings,fixed on surface of wall ,ceiling etc., complete and making good disturbed surface of wall,ceiling etc., including taking down old UNSV existing submain wiring complete all as specified and as directed.
Note : - Four runs of 6.0Sqmm cable and one run of earth wire 6.0 Sqmm & conduit shall be measured as one unit length and extra length of cable required for connection to MCBs shall be deemed to be include in unit rate quoted by bidder. | 250 | RM | 31,00,000 | ₹77,50,00,000 |
| - | M&L for Earthing complete for poles/DBs with galvanised steel earth plate electrode, 600mm x 600mm x 6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal (ground level) with top edge of the plate not less than 1.50m below normal ground level connected to galvanized iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point,GI tubing 20mm bore light grade protection pipe, GI watering pipe 20mm bore medium grade with funnel & wire mesh, charcoal & salt, 40 mm thick pre-cast RCC cover (1:2:4) type B-1(using 20 mm graded crushed stone aggregate )reinforced with 8mm dia TMT bar @ 75mm c/c both way with mild steel handle 20mm dia round bar , plastering 15mm thick with CM (1:6:) internally and upto 150mm below ground level externally & angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-1(using 20 mm graded crushed stone aggregate ) (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m & returning filling) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I including taking down old UNSV existing earthing & making good disturbed surface complete all as specified and as directed.
Notes: -(i) Earth lead & protection pipes length upto & including 7.50 metre.
(ii) Earth filling shall be done by vegetable soil.
(iii) Soil should be free from stone, boulders, aggregate, gravels etc. | 26 | Each Job | 31,00,000 | ₹8,06,00,000 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
TENDERDOCUMENTS.pdf
Tender Documents • 2.14 MB
BOQ_868090.xls
BOQ • 2.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .