Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.9 LAccepted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹4.9 L | 1 | Accepted-Finance L1 |
| 2 | 2₹5.3 L+₹43,760 (8.93%)Accepted-Finance | ₹5.3 L+₹43,760 (8.93%) | 2 | Accepted-Finance L2 |
Tender Value
₹5.9 L
EMD Value
₹11,800
Closing Date
29 Jan 2021, 4:00 pmClosed
Assistant Executive Engineer (Electrical)
Assistant Executive Engineer (Electrical) CSIR-IHBT, Palampur
CAMC of Central Air Conditioning Plant of Animal House
2021_CSIR_67092_1
5-229/Ws/20
Open Tender
Electrical Works
Works
365 days
CSIR-IHBT, Palampur
As per NIT and contract document
2 documents required · 2 mandatory
₹500
Director
₹11,800
2 Feb 2021
14 Jan 2021
1 Feb 2021
14 Jan 2021
29 Jan 2021
15 Jan 2021
14 Jan 2021 - 22 Jan 2021
Amount
Comprehensive annual maintenance of 48TR X 2 Nos. i.e 96TR (routine & preventive including all parts) for one years of Air Cooled central air coditioning plant . AMC also comprises Breakdown maintenance of High side & Low side of the Air conditioning plant comprising of all the machinary, equipment installed as per following details: 1. Scroll Chiller 48.0 Tonn with DX-U Tube cooler,air cooled condenser=02 No.(01 No.standby. 2. Hot water Generator 36 kw(with 03 bank)= 02 Set 3.Chilled/ Hot water pump 120 USGPM * 25 M = 02 Set 4. Air handling unit i) Double Skin AHU 300 CFM / 2.0 TR = 02 Set ii) Double Skin AHU 400 CFM / 3.0 TR = 01 Set iii) Double Skin AHU 450 CFM / 3.0 TR = 03 Set iv)Double Skin AHU 500 CFM / 3.5 TR = 03 Set v) Double Skin AHU 700 CFM / 5.0 TR = 01Set vi) Double Skin AHU 800 CFM / 5.5 TR = 02Set vii) Double Skin AHU 1100 CFM / 7.5 TR = 01Set 5 Exhaust Air Blower i) 1800 CFM (65MM Static Pressure) = 01 Set ii) 1300 CFM (65MM Static Pressure) = 01 Set iii) 700 CFM (65MM Static Pressure) = 01 Set iv) 500 CFM (65MM Static Pressure) = 02 Set v) 450 CFM (65MM Static Pressure) = 07 Set vi) 300 CFM (65MM Static Pressure) = 01 Set 6. Supply panel (integrated for chiller, hot water generator, pump, AHU and exhaust fan). 7. Humidifier = 13 No. (Tank consisting of Heating Element & Float valve) Note: Breakdown maintenance will be carried out on arising , within 48 hours, regular preventive maintenance is to be done on monthly basis.
Comprehensive annual maintenance of 8.5 TR X 4 Nos. i.e 34 TR (routine & preventive including all parts) for one years of Ductable Packaged Air Conditioner . AMC also comprises Breakdown maintenance of High side & Low side of the Air conditioning plant comprising of all the machinary, equipment installed. Note: Breakdown maintenance will be carried out on arising , within 48 hours, regular preventive maintenance is to be done on monthly basis.
Supply and fixing of Following size Hepa Filters: i) size 500x500x305 =1 No. ii) size 610x305x305 =12 Nos.
National Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .