Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC 234 4 JC BOSE ROAD KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹26.7 L+₹1.6 L (6.38%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹27.7 L+₹2.7 L (10.6%)Rejected-Finance KHUDIRAMPALLY P O BANARHAT DISTT JALPAIGURI W B PIN 735202 | JALPAIGURI | WEST BENGAL | 735202 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹31.1 L+₹6.0 L (23.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
13 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cwe Binnaguri
HQ CWE BINNAGURI
COMPREHENSIVE SPL REPAIR AND SPL REPAIR OF ROOF TREATMENR OF CERTAIN BUILDING AT BINNAGURI MIL STN UNDER GE NORTH BINNAGURI
2020_MES_378397_1
8010/BIN(N) 41 of 2020-21
Open Tender
Civil Works
Item Rate
120 days
Binnaguri Mil Stn
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE NORTH BINNAGURI
₹68,000
Yes
10 Nov 2020
17 Sept 2020
14 Oct 2020
17 Sept 2020
13 Oct 2020
1 Oct 2020
60 days
Amount
Schedule 'A'
Taking down cement plaster on wall of any description incl racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:4 on facia, roof projection, chajja etc finished even & smooth without using extra cement with using water proofing compound @3% by the weight of cement complete all as specified and as directed. Note:- Water proofing treatment shall be paid and measured separately complete all as specified and as directed.
M&L for Rendering 15mm thick in CM (1:6) on concrete/brick wall surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for 10 mm thick plaster rendering on fair faces of concrete surfaces as in ceiling in CM(1:3) finished even and smooth (without using extra cement) complete all as specified and as directed.
M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) mixed with water proofing compound in top layer @3% by the weight of cement or as per manufacturer's instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed. Note : Integral water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed.
M&L for three coats of white wash on walls over newly plastered surfaces of wall incl preparation of surfaces etc complete all as specified and as directed.
All as per item No 7.00 here-in-above but 3 coat of white wash on ceiling complete all as specified and as directed.
M&L for applying two coats of colour wash on newly plastered surfaces of wall including preparation complete all as specified and as directed.
M&L for two coats of acrylic emulsion paint (weather coat) over newly plastered surface of wall and necessary preparation of surfaces including 1mm thick wall putty complete all as specified and as directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing scrapping down to remove smooke soot moulds moss and efflorescence salts and treating oil and greasy spots etc and applying a coat of colour wash complete all as specified and as directed.
M&L for preparing old decorated plastered or unplastered surfaces of walls including cornices, pilasters and other wall features etc by brooming down or steel wire brushing scrapping down to remove smooke soot moulds moss and efflorescence salts and treating oil and greasy spots etc and applying one coat of white washing on the same all as complete all as specified and as directed.
All as per srl item No 12.00 here-in-above but on ceiling complete all as specified and as directed.
M&L for one coat of applying acrylic emulsion paint (weather coat) over existing surfaces of wall,chajja,column etc and including necessary preparation of surfaces including wall putty/white cement wherever required to fill the wall cracks/holes complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M & L Machine cut kota stone slab in flooring 18 to 20 mm thick area of each tile exceeding 0.18sqm over and including 20mm thick cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing complete all as specified and as directed.
M&L for kota stone slab 18 to 20mm thick in riser or steps, skirting, dado and pillar laid over 10 mm thick screed bed cement screed (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for 75mm thick PCC (1:3:6) type C-2 with using 40mm graded stone aggregates as in plinth protection/footpaths, finishing the concrete surfaces even and smooth without using extra cement, all complete as specified and as directed. (Note : Joint 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in quoted rate for concrete in plinth protection.)
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles, and rubbish off the premises complete all as specified and as directed.
M&L for 15mm thick screed bed or bedding layer in CM (1:6) as in floor complete all as specified and as directed.
M&L Rendering 10mm thick in cement mortar in 1:4 on fair face of brick work in dado and skirting finish fare & even to receive tiles etc. Complete all as specified and as directed.
S&F for glazed ceramic colored/printed tiles size 300x450x7 mm thick as in vertical surfaces such as skirting dados & repairs to step etc. Set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles complete all as specified and as directed.
M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles complete all as specified and as directed.
S&F in repair steel window with side hung shutters with projecting type hinges, 3mm thick 100mm long copper oxidised finish mild steel handle and 3mm thick 300mm long mild steel copper oxidised finish peg stays and glazing bars, dovetailed or welded with applying one shop coat of red oxide zinc chromate primer before fixing including taking down old unserviceable steel windows form existing position and making good disturbed surfaces of walls etc in all respect as per existing specification all complete as specified and as directed.
S&F in repairs steel window with side hung shutter incl projecting hing with steel handle and steel peg stay complete without glazing bars, dovetailed or welded including taking down old unserviceable steel windows form existing position and making good disturbed surfaces of walls etc in all respect as per existing specification all complete as specified and as directed.
S&F in repair aluminum anodized louvered ventilators with 4mm thick glass louvers, without sash bars, of aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and with suitable locking arrangements incl taking down old complete all as specified and directed.
S&F Mild steel framed work such as grills, gratings, guard bar etc with ends of bars shouldered or riveted or for forged into spikes framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290. Gde -E- 165 complete all as specified and as directed.
S&F Stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed.
S&F of 3mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.
M&L for preparation of new or previously untreated steel surfaces any description over 10 Cm in width or girth not otherwise described and applying 2 coats of synthetic enamel paint complete all as specified and as directed.
Taking down PVC/AC soil pipe including fittings as in wall of any dia complete all as specified and as directed.
S&F 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified and as directed.
All as per item above 33.00 here-in-above but for 75 mm complete all as specified and as directed.
S&F 110mm dia PVC bends of any radius with access door complete all as specified and as directed.
S&F 110mm dia PVC (SWR) branch piece single (single 'Y') equal or unequal with access door complete all as specified and as directed.
S&F in repair 100mm dia PVC floor trap with grating including jointing to waste pipe fixed in cement concrete (1:2:4), type B1 complete all as specified and as directed.
Taking up or down GI tubing 15mm bore pipe and connection including cleaning for refixing or removal from site complete all as specified and as directed.
Taking up or down GI tubing 20mm bore pipe and connection including cleaning for refixing or removal from site complete all as specified and as directed.
S & F 15mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S & F 20mm bore medium grade galvanised tube with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed.
S & F in repair 15mm size PVC Connection with PTMT nut of length 450mm complete all as specified and as directed.
S&F in repairs vitreous china wash basin white flate back size 580x450mm incl 32mm waste chromium plated waste coupling and 32mm dia bore PVC waste pipe ,including brackets complete all as specified and as directed.
S&F in repair pillar taps with heads, chromium plated, screwed down high pressure with or without lettered 'hot or cold' with long screwed shanks and flynuts screwed for iron pipe and fixed for 15mm complete all as specified and as directed.
S&F in repairs Bib taps fancy type chromium plated for 15mm bore pipe, screwed down for iron pipes or for brass ferrule all complete as specified and as directed.
Supply & fixed in repairs fancy type chromium plated angular Stop valve (ISI Marked), cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore and fixed in repair complete all as specified and as directed.
S&F in repair 15mm bore chromium plated shower roses with arm (size of arm 195mm long with bend to 45 degree) complete all as specified and as directed.
S&F in repairs fancy type Chromium plated Stop valves long shank and cup(concealed type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in iron pipe 15mm bore complete all as specified and as directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete incl provision of cement concrete bedding plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S&F in repairs urinal bowl type flat back size of 465x355x265mm white with CP grating and union for discharge pipe complete all as specified and as directed.
S&F in repair 10 ltr capacity PVC flushing cistern low level white colour incl PVC connection PVC flush pipe of reqd length CI brackets nin lieu of old unserviceable push button flushing cistern complete all as specified and as directed.
Supply & fixed in repair, Aluminum anodised tubular towel rail 20 mm dia, 'D' type 60 cm long between flanges complete all as specified and as directed.
Supply & fixed in repairs Soap dish/tray, Stain less steel, fixed to plugs with CP brass screws complete all as specified and as directed.
Supply & fixed in repairs PVC waste pipe with union, flexible suitable for wash hand basin or urinal, 32 mm dia complete all as specified and as directed.
Taking down chowkat or frame n.exc 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Solid PVC door frame of size 50 X 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube, supplied and fixed in repair in opening as per specifications and drawing complete all as specified and as directed.
Factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tube for top and bottom rail, MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles & plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail & bottom rail; Panelling of plain colur PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, Supplied and Fixed in the frame at site as per specification and drawings complete all as specified and directed.
S&F for Aluminium alloy anodised handle fabricated 150mm long complete all as specified and as directed.
S&F for Aluminium alloy anodised barrel tower bolts 150 mm long complete all as specified and as directed.
S&F 75 mm stainless steel butt hinges medium weight cold rolled mild steel complete all as specified and as directed.
M&L for repair of bath room out let pipe, rain water pipe mouth with the help of chemical component conbextar GP2 including PCC 1:2:4(20mm graded aggregate) as per manufacturer instructions complete all as specified and directed.
M&L for prepare the wall and floor surfaces of sunken portion of toilet and applying the water proofing materials BRUSH BOND RFX & NITO BOND BBX including PCC 1:2:4(20mm graded aggregate) as per manufacturer instructions complete all as specified and directed . (NOTE : Net floor area shall be measured and paid accordingly)
Demolition of cement concrete (reinforced) above ground floors and pavings n.exc 15 cm thickness complete all as specified and directed.
Demolition of brick work built in cement mortar and removing from site complete all as specified and as directed.
Taking down existing roof treatment(water proofing membrane etc) including screed bed complete from roof surfaces including parapets and lowering and removing the same to a distance exc. 50 m and n. exc. 100 m incl roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust, etc complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces with cement mortar (1:4) mixed with water proofing compound in layer @ 3% by the weight of cement or as per manufacturer's instructions in order to maintain proper slope over existing roof surfaces, rendering is to be finished even and smooth (without using extra lime or cement) for laying brush bond waterproofing coating complete all as specified and as directed. Note:- Water proofing treatment shall be paid and measured separately.
M&L for providing and applying single component acrylic polymer modified, fibre reinforced waterproof coating brush bond Roof Guard in 3 coats of application @ 0.5 litre /sqm coat, including sprinkling of clean sand (300 microns - particle size).The product should have following properties solid content : 70%, tensite strength (ASTM D 412): 1.10 MPs, elongation (ASTM D12) : 100% Resistance to ageing due to UV radiation . 1000 hours no change rapid chloride penetration : very low resistance to algae growth passes, zero rating / permeability (mm): 5.0 water vapour transmission : 6.0gm/sqm h No of coats : 3 (minimum) adhesive bond strength : > 0.92 N/mm2 complete all as specified and as directed.
Demolition of cement concrete in ground floor and paving n ex. 15cm thickness (below or above ground level) including removal of debris / demolished materials to a distance exc 50m and n exc. 250m complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded aggregate) in floor kerbs, pading concrete over roof or mud stops, rounded or chamferred on edges complete all as specified and as directed.
M&L for 10mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing ro9of surfaces for laying APP base polymeric membrane, finished even and smooth without using extra cement complete all as specified and as directed. (Note : Polymeric membrane shall be measured and paid separately under relevant item of this schedule A)
M&L for water proofing treatment to RCC roof slab, including parapet comprising with the following courses of treatment / specification from bottom to top complete all as specified and as directed. :- (a) Applying bituminous primer @ 0.4 ltrs per sqm over plastered surfaces of roof incl parapet surface. (b) Over the priming coat laying one layer APP based polymembric membrane of ap-proved manufacturer 3mm thick weight not less than 3.6 kgs per sqm inside the groove of parapet wall and shall be finished by membrane flashing. (Note : (i) Laying APP based polymeric membrane shall be done torch on method or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (iii) App based polymeric membrane shall be "MOPLY FP 3MM" manufactured by M/s Texsa India Limited or equivalent. (iv) Applying two coats of aluminium paint over APP membrane.)
Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc complete all as specified and as directed.
M&L for 15mm thick plastering in CM (1:4) on fair faces of brick / concrete surface top layer finished even and fair without using extra cement with water proofing compound on external wall surfaces (WPC will be measured and paid separately) complete all as specified and as directed.
Demolition of Mud in roofs, any thickness, including PCC tiles, plastering and leeping (whether full thickness removed or only a part thereof) including removing of demolished material out of defence land complete all as specified and as directed.
M&L for preparation of new plastered surface and applying two coat of cement base paint over a coat of alkali resistant priming paint complete all as specified and as directed.
Taking down carefully old/unsv copper/alluminium any type of point wiring for one light, socket, fan, bell or power etc incl all fittings such as switches sockets, holders, light fittings, fan regulators, call bell etc and making good the disturbed surface of wall ceiling complete all as specified and directed.
M&L for concealed Point wiring including cutting and chasing on wall / roof surface controlled by one switch with 1.50 Sqmm (nominal area) FRLS, PVC insulated 1100 volts grade multi stranded copper conductor single core unsheathed cable and FRLS, ISI marked, PVC insulated 1100 volts grade multi stranded copper conductor single core of size 1.50 Sqmm as earth continuity conductor connected to common earth dolly, drawn through in and including rigid PVC conduit (Medium Grade) of suitable size, with all fittings, ISI marked and accessories, the pipe shall be fixed with clamping and shadle including provision of mild steel terminal boxes/Sunken boxes of suitable size made with 1.22 mm thick mild steel sheet recessed in wall with a coat of black bituminous paint and providing of with 3mm thick bakelite/PVC sheet ISI marked top cover , suitable for fixing of switches / sockets / regulators etc. fixed in recess of wall with brass chromium plated screws and cap washer for one light point controlled by one wayswitch 5/6 amps complete all as specified and as directed :- One light point controlled by one way switch 5/6 amps.
All as per item No 77.00 here-in-ablve but one ceiling fan / Exhaust fan point controlled by one way switch 5/6 amps complete all as specified and as directed.
All as per item No 77.00 here-in-ablve but one socket out let 5/6 amps point on the independent board complete all as specified and as directed.
All as per item No 77.00 here-in-ablve but one socket out let 5/6 amps point on the same board complete all as specified and as directed.
All as per item No 77.00 here-in-ablve but one light point controlled by two 2-way switch 5/6 amps omplete all as specified and as directed.
All as per item No 77.00 here-in-above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed
S&F switch piano flush type 5/6 amps single pole one way complete all as specified and directed.
S&F switch piano flush type 5/6 amps single pole two way complete all as specified and as directed.
S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and directed.
S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type complete all as specified and directed by Engr-in-Charge.
S&F in switch piano flush type 15/16 amps single pole one way complete all as specified and directed.
S&F Switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with, complete all as specified and directed.
S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S & F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F LED white glass Lamp 1x14 Watt 230V Base-22 complete all as specified and directed.
S & F in deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish complete all as specified and directed.
S&F in replacement 4 feet LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type (decorative) batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 Single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to ceiling rose complete all as specified and as directed.
M & L for street light bracket made out of GI pipe light grade 32 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.2 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 25 x 5 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and directed.
Taking down carefully Ceiling fan after disconnecting electric connection and refixing with and incl necessary paint and minor repair complete all as specified and directed.
M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor including one run of 6 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed. NOTE : (i) Two run of submain wiring cable alongwith one run of earth wire with and including PVC conduit pipe shall be measured as one unit length.
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, 415Volt IP-20 protection suitable for fixing MCB"S/isolators with and including taking down old one complete all as specified and directed.
S&F MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB"S/isolators complete with and including taking down old unsv one all as specified and directed.
S&F MCB, Single pole & neutral, 35 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one complete all as specified and as directed.
S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one complete all as specified and as directed.
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 100 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
M&L in replacement for factory made sheet metal box made out of 2 mm thick MS sheet of size not less than 600 X 900 X 200 mm with double door hinged shutter and locking arrangement for fixing DBs, KWH Metter etc flashed / grouting on wall incl painting with two coated of powder coated paint over a coat of red oxide primer with suitable glass vision panel of each meters shall be provided in the door to easy meters reading , including taking down the old one complete all as specified & directed.
Disconnecting and removing U/S building security light fitting of any type from bldg and Supply and fixing new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP 66 protection and impact resistance of IK07system of not less than 35 Watts IP 66 type incl standard fittings pressure die cast aluminium housing, heat resistant toughened glass, epoxy powder coated finish complete with Electronic driver, Surge protector not less than 5 KV and all accessories duly prewired complete all as specified and directed.
Taking out old unserviceable cable of any size carefully from trenches after disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 4 core with and including all fixing & connecting accessories such as Aluminum cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A').
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cms in depth complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion all as directed and as specified.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .