Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
27 Apr 2024, 12:00 pmClosed
Superintending Engineer (D-2) Trans Gomti, LESA, L
Superintending Engineer (D-2) Trans Gomti, LESA, Lucknow
Executive of works against O and M Head at various places (06 Nos 33/11 KV Sub-Station-Vishwaskhand, Vipinkhand, Gwari kalvart, Virajkhand, Mantriawas and Vibhutikhand) under the jurisdiction of Executive Engineer, EUDD, Gomtinagar, LESA, Lucknow
2023_MVVNL_813650_4
16/EUDC-II/2023-24
Open Tender
Electrical Works
Fixed-rate
365 days
EUDD-Gomtinagar LESA Lucknow
As Per Tender Document
2 documents required · 2 mandatory
₹1,180
EE, EUTD-II, Lesa, Lucknow
₹10,000
8 May 2024
19 Apr 2024
27 Apr 2024
19 Apr 2024
27 Apr 2024
19 Apr 2024
Amount
Repairing of T/f Plinth , its plastering, painting as per norms of RESSPO. (All the material will be arranged by the contractor at his own cost) RMT
Repairing of existing damaged plinth of 33 kV VCB removal of existing nut & bolts for proper alignment, grouting of nut & bolts as per requirement all the material will be arranged by the contractor.
Dragging of 33 KV VCB from outside upto control room, placement of the same on existing plinth, erection and commissioning.
Installation & Commissioning of 33 KV Line isolator on the existing structure in proper alignment so as to ensure smooth operation of the same.
Installation & Commissioning of 33 KV Bus isolator on the existing structure in proper alignment so as to ensure smooth operation of the same.
Installation & Commissioning of 33 KV Fuse Set on the existing structure in proper alignment so as to ensure smooth operation of the same.
Dismantling of following old & damaged equipments from the structures, its dragging outside control room/Switchyard upto loading place, its loading-carriage upto Store Centre/JE Store, unloading and proper stacking:
33 KV VCB 800 A- 750 MVA
33 KV Line Isolator 400 A
33 KV Bus Isolator 400 A
33 KV Fuse set
Carriage and instalation of Battery and Battery Charges
Repairing of wiremesh fencing, retaining wall, fabrication &erection of Wiremesh fencing upto the height of 2.0 Maround Transformer with retaining wall & 1 no. gate with locking arrangement made of MS Angle iron of size 50x50x6 mm jointed with nuts and bolts. The panel must be supported with MS Flat of size 50x6 mm.Wiremesh of size 10 SWG rectangle type, its painting as per norms of RESSPO. (All the material will be arranged by the contractor at his own cost)
Repairing , Weilding of S.T Pole. With MS Angle iron of size 50x50x6 mm jointed with nuts and bolts.
Replacement of damaged PCC Pole 8.5 mtr.Erection, Grouting (0.268 Cu M per pole), plinthing (300 mm above ground level) of Single PCC Pole 8.5 M long . 1/6 of total length of poles will remain under the ground and planted on Stone pad of size 300x300x75 mm long with grouting.
Replacement of damaged S.T Pole 9.0 mtr. long Erection, Grouting (0.268 Cu M per pole), plinthing (300 mm above ground level) of Single S.T. Pole 11 M long 1/6 of total length of poles will remain under the ground
Replacement of damaged S.T Pole 11 mtr. long with Erection, Grouting (0.268 Cu M per pole), plinthing (300 mm above ground level) of Single S.T. Pole 11 M long 1/6 of total length of poles will remain under the ground
Construction of damaged L.T line 3 Phase 04 wire on PCC Pole.
Regrouting of ST/PCC Pole
Replacement of damaged H.T line on H.T Pole.
Replacemen of damaged L.T line on A.B cable single phase 3x95+1x70+1x16 sq.mm.
Replacemenof damaged L.T line on A.B cable single phase 3x120+1x95+1x16 sq.mm.
Construction of damaged H.T line on S.T Pole.
Replacement of damage 11 KV H.T cable with Relaying with New H.T cable 3x70. Sq.mm.
Replacement of damage 11 KV H.T cable with Relaying with New H.T cable 3x120. Sq.mm.
Replacement of damage 11 KV H.T cable with Relaying with New H.T cable 3x185. Sq.mm.
Replacement of damage 33 KV H.T cable with Relaying with New H.T cable 3x300. Sq.mm.
Guarding of 11 KV line with G.I. Wire of size 8 SWG as per RESSPO Norms
Fixing of guarding angle of size 40x40x5x1500mm (All material shall be supply by the contractor)
Erection of stay set of 16X1800 mm rod duly painted with red oxide, anchor plate, thumble turn buckle and stay insulator etc. digging of pit of size 0.4X0.6X1.6m for grouting by 1:3:6 cement concrete, with stay of size 7/8 swg, nuzzling & grouting.
Boring type earthing of 11/0.4 KV various Substation by boring and lowering of 30 Mtr deep or upto water level 1.5” dia B Class Jindal make GI Pipe its connection in between transformer and boring with G.I. Strip of size 50x6 mm (All the material will be arranged by the contractor)
Earthing of poles with MS Earthing of size 20x2500 mm including its connection
Resegging, restrengthening of Ht Line 11kv 3 Phase 3 wire
Repaire of masonry type Distribution Pillar boxes with first class brick ballast cement, coarse sand, local sand, brick ballast and MS round bar of 10 mm dia including supply and mounting of 02 nos. Straight MS Angle 50x50x6x750 mm 2 nos. Henely type tailless fuse unit one no. for incoming and other for outgoing, Copper bus bar 1000x50x6 mm with locking arrangement made of 18 SWG BP Sheet (All the material will be arranged by the contractor)
Catenary type laying of LT cable 3.5X400/240
Cutting and removel of fallen (unrooted) trees on electricals instalation due to storm
M/s R.K. Construction
M/s. MAHARISHI CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .