GE (North) Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
REPAIR/ MAINT OF LT ELECTRICAL DISTRIBUTION SYSTEM AND ALLIED WORKS AT OTM ACCN NORTH ZONE UNDER GE (NORTH) BINNAGURI
2026_MES_776994_2
8701 / 56 / 2026-27 / 08 / E8
Open Tender
Civil Works
Item Rate
270 days
Binnaguri cantonment
As per Tender document
8 documents required · 8 mandatory
₹500
GE (North) Binnaguri
₹80,000
Yes
15 Oct 2026
24 Sept 2026
17 Oct 2026
24 Sept 2026
15 Oct 2026
1 Oct 2026
24 Sept 2026 - 28 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out old unserviceable cable of any size carefully from trenches after disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed.
Note: The Excavation and earth work shall be mesured and paid separately under relevant item of Schedule. | 1,680 | RM | - | - |
| 2 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded,galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 4 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc and including taking down dismantling of old existing unserviceable one complete as specified and as directed.
( NOTE: Earthwork & Excavation, Gl pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule 'A'). | 450 | RM | - | - |
| 3 | All as per ser item No 2 above but of cross sectional area 35 sqmm 3.5 core | 175 | RM | - | - |
| 4 | All as per ser item No 2 above but of cross sectional area 50 sqmm 3.5 core | 250 | RM | - | - |
| 5 | All as per ser item No 2 above but of cross sectional area 70 sqmm 3.5 core | 200 | RM | - | - |
| 6 | All as per ser item No 2 above but of cross sectional area 95 sqmm 3.5 core | 175 | RM | - | - |
| 7 | All as per ser item No 2 above but of cross sectional area 120 sqmm 3.5 core | 230 | RM | - | - |
| 8 | All as per ser item No 2 above but of cross sectional area 240 sqmm 3.5 core | 200 | RM | - | - |
| 9 | Digging out incoming and outgoing cables of any sizes from loops near junction box/ feeder pillar box in trenches, cutting burnt out uninsulated portion of cable and relaying /refixing in trenches & returning, refilling the excavated soil and connecting the cables with bus bars including provision of suitable size of aluminum lugs complete all as specified and as directed. | 20 | Each Job | - | - |
| 10 | Relaying in trenches or passing through pipe, 1100 volts grade, LT electric power UG cables, of any type/Size with and including all fixing & connecting accessories such as Aluminum cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
Note : The serviceable cable obtained from taking out from ser No 1 here-in-before shall be reused. | 150 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
Tender_56.pdf
Tender Documents • 1.10 MB
BOQ_886665.xls
BOQ • 0.34 MB
Sch.pdf
Additional Documents • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .