Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC | ₹30.4 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹30.5 LRejected-Finance 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | ₹30.5 L | L2 | Rejected-Finance Unsuccessful bidder |
| 3 | L3₹32.7 LRejected-Finance | ₹32.7 L | L3 | Rejected-Finance Unsuccessful bidder |
| 4 | L4₹34.5 LRejected-Finance | ₹34.5 L | L4 | Rejected-Finance Unsuccessful bidder |
| 5 | L5₹34.6 LRejected-Finance 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | ₹34.6 L | L5 | Rejected-Finance Unsuccessful bidder |
| Sl No | Description | Qty | Unit | ANIL RAI AND COMPANY L4 | M/s.Sai Agency L2 | M/s Brahamaputra Wood Industries L6 | MONA GENERATOR SEVICES PVT. LTD. L5 | M/S L N ENTERPRISE L3 | M/S RSB ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of silent diesel engine driven generating set outdoor type 415 V, 3 phase, 4 wire as per BS 5514/IS-10002 as per existing CPCB-IV norms complete with standard control panel, of capacity continuous rating 30 KVA/24 KW at NTP conditions with acoustic enclosure and canopy cover considering all derating factors and comprising of the following :-
(a) ALTERNATOR : Self regulated with brushless self excitation 30 KVA, 415 V, 3 phase, 4 wire, 50 HZ, 0.8 P.F.,1500 RPM, with voltage variation plus or minus 2.5% of rated voltage from no-load to full-load foot mounted, screen protected drip proof type with class 'F' insulation, closed coupled single bearing alternator, with necessary controls as recommended by the manufacturers, conforming to BS-5000/IS-4772, capable of supplying unbalanced load.
(b) ENGINE : Multi/cylinder,compression ignition, heavy duty,compact diesel engine liquid cooled with standard accessories, all as per BS-5514/ISO-3046,1500 RPM,control gauges, RPM/Hours meters etc; shaft H.P. suitable for generating application and capable of giving an output of 30 KVA/24 KW for coupled alternator under NTP conditions, complete with following:-
(i) Flywheel housing with flywheel to suit closed coupled single bearing alternator.
(ii) Air-cleaner dry type with vacuum indicator. | 1 | Each | 7,35,700 ₹7.4 L | 6,75,000 ₹6.8 L | 7,75,000 ₹7.8 L | 7,48,684 ₹7.5 L | 7,50,000 ₹7.5 L | 6,40,000 ₹6.4 L |
| 1.01(iii) Fuel pump and fuel piping. (iv) Fuel filter with water separator and filter element. (v) Lub-oil filter with filter element (vi) D.C. starter 12 volts. (vii) Storage Batteries of suitable voltage and ampere-hours as recommended by the manufacturers. (viii) Residential silencer as per existing CPCB IV norms (ix) Supporting/fixing arrangement for muffler with celiling through antivibration pads. (x) Engine overspeed stop/trip switch. (xi) Radiator with fan. (xii) Dynamo for battery charging. (xiii) Corrosion inhibitor coolant. (xiv) Engine control panel electronic digital display type consisting of battery voltage indicator, lub oil temp and pressure gauges coolant water temp gauge, RPM indicator cum hour meter etc. (xv) Safety controls for alarm due to high water temp (HWT) and low lub oil pressure (LLOP). (xvi) Any other devices/accessories recommended/supplied by the manufacturers as standard eqpt. (c) SKID : The engine and alternator will be coupled,aligned and mounted on a specially designed common base frame fabricated from M.S. channels of suitable cross sectional area and length with bottom drilled holes suitable for and including supplying and fixing anti vibration pads of required size and numbers as recommended by the manufacturers for mounting of 30KVA/24KW DG set. (d) AMF PANEL : AMF panel shall be of suitable size factory outdoor cubical type front openable fabricated from CRCA steel sheet complete as per manufacturer specification of Diesel Engine suitable for DG Set of capacity 30 KVA in all respects. | |||||||||
| 1.02Notes :- (i) Contractor will satisfactorily conduct load test of DG set for 12 hours including run on 10% overload for 1 hour. (ii) Testing equipment will be arranged by the contractor and cost thereof is deemed to be included in quoted rate by the contractor.. (iii) Fuel/oil required for load test shall be arranged by the contractor and cost thereof is deemed to be included in quoted rate by the contractor. (iv) AMF panel and DG set shall be procured from same OEM/ OEM recommeded make. (v) DG set shall be tested by the representative of Accepting Officer before commisioning and cost thereof deemed to be included in quoted rates. (vi) The foundation of DG set shall be provided as per manufacturer's drawing / instructions and quoted rate shall deemed to be included for this provision and nothing extra shall be admmisible on this account. (vii) Contractor shall submit e-way bill, Purchase Voucher, Test certificate/ Test report etc alongwith payment. (viii) Shifting of Old DG set to store yard as per direction of Engr-in-Charge deemed included in the quoted rate. | |||||||||
| 2.00 | Supply, installation, testing and commissioning of silent diesel engine driven generating set outdoor type 415 V, 3 phase, 4 wire as per BS 5514/IS-10002 as per existing CPCB-IV norms complete with standard control panel, of capacity continuous rating 40 KVA/32 KW at NTP conditions with acoustic enclosure and canopy cover considering all derating factors and comprising of the following :-
(a) ALTERNATOR : Self regulated with brushless self excitation 40 KVA, 415 V, 3 phase, 4 wire, 50 HZ, 0.8 P.F.,1500 RPM, with voltage variation plus or minus 2.5% of rated voltage from no-load to full-load foot mounted, screen protected drip proof type with class 'F' insulation, closed coupled single bearing alternator, with necessary controls as recommended by the manufacturers, conforming to BS-5000/IS-4772, capable of supplying unbalanced load.
(b) ENGINE : Multi/cylinder,compression ignition, heavy duty,compact diesel engine liquid cooled with standard accessories, all as per BS-5514/ISO-3046,1500 RPM,control gauges, RPM/Hours meters etc; shaft H.P. suitable for generating application and capable of giving an output of 40 KVA/32 KW for coupled alternator under NTP conditions, complete with following:- | 3 | Each | 8,15,700 ₹24.5 L | 7,50,000 ₹22.5 L | 10,10,000 ₹30.3 L | 8,59,918 ₹25.8 L | 8,00,000 ₹24 L | 7,55,000 ₹22.6 L |
| 2.01(i) Flywheel housing with flywheel to suit closed coupled single bearing alternator. (ii) Air-cleaner dry type with vacuum indicator. (iii) Fuel pump and fuel piping. (iv) Fuel filter with water separator and filter element. (v) Lub-oil filter with filter element (vi) D.C. starter 12 volts. (vii) Storage Batteries of suitable voltage and ampere-hours as recommended by the manufacturers. (viii) Residential silencer as per existing CPCB IV norms (ix) Supporting/fixing arrangement for muffler with celiling through antivibration pads. (x) Engine overspeed stop/trip switch. (xi) Radiator with fan. (xii) Dynamo for battery charging. (xiii) Corrosion inhibitor coolant. (xiv) Engine control panel electronic digital display type consisting of battery voltage indicator, lub oil temp and pressure gauges coolant water temp gauge, RPM indicator cum hour meter etc. (xv) Safety controls for alarm due to high water temp (HWT) and low lub oil pressure (LLOP). (xvi) Any other devices/accessories recommended/supplied by the manufacturers as standard eqpt. (c) SKID : The engine and alternator will be coupled,aligned and mounted on a specially designed common base frame fabricated from M.S. channels of suitable cross sectional area and length with bottom drilled holes suitable for and including supplying and fixing anti vibration pads of required size and numbers as recommended by the manufacturers for mounting of 40 KVA/32 KW DG set. | |||||||||
| 2.02(d) AMF PANEL : AMF panel shall be of suitable size factory outdoor cubical type front openable fabricated from CRCA steel sheet complete as per manufacturer specification of Diesel Engine suitable for DG Set of capacity 40 KVA in all respects. Notes :- (i) Contractor will satisfactorily conduct load test of DG set for 12 hours including run on 10% overload for 1 hour. (ii) Testing equipment will be arranged by the contractor and cost thereof is deemed to be included in quoted rate by the contractor.. (iii) Fuel/oil required for load test shall be arranged by the contractor and cost thereof is deemed to be included in quoted rate by the contractor. (iv) AMF panel and DG set shall be procured from same OEM/ OEM recommeded make. (v) DG set shall be tested by the representative of Accepting Officer before commisioning and cost thereof deemed to be included in quoted rates. (vi) The foundation of DG set shall be provided as per manufacturer's drawing / instructions and quoted rate shall deemed to be included for this provision and nothing extra shall be admmisible on this account. (vii) Contractor shall submit e-way bill, Purchase Voucher, Test certificate/ Test report etc alongwith payment. (viii) Shifting of Old DG set to store yard as per direction of Engr-in-Charge deemed included in the quoted rate. | |||||||||
| 3.00 | Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.3 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 25x4mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion and taking down complete
Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004. | 16 | Each | 12,500 ₹2 L | 6,000 ₹96,000 | 6,000 ₹96,000 | 6,183 ₹98,928 | 5,000 ₹80,000 | 6,300 ₹1.0 L |
| 4.00 | Excavation in trenches not exc 1.5m in width and 1.5 M in depth and getting out excavated soil soft/loose soil. | 10.13 | Cum | 250 ₹2,532.50 | 150 ₹1,519.50 | 150 ₹1,519.50 | 202 ₹2,046.26 | 120 ₹1,215.60 | 120 ₹1,215.60 |
| 5.00 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm | 6.5 | Cum | 200 ₹1,300 | 50 ₹325 | 50 ₹325 | 80 ₹520 | 80 ₹520 | 120 ₹780 |
| 6.00 | Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. | 3.62 | Cum | 1,250 ₹4,525 | 40 ₹144.80 | 55 ₹199.10 | 49 ₹177.38 | 50 ₹181 | 140 ₹506.80 |
Updated dates
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
19 Dec 2025, 6:00 pmClosed
CWE Tezpur
HQ CWE TEZPUR PO DEKARGAON DIST SONITPUR PIN 784501 (ASSAM)
SPL REPAIR/REPLACEMENT FOR BER DG SET AGAINST BER AT AGE CHARDUAR UNDER GE(N) TEZPUR
2025_MES_741009_1
8213/TEZ(N)/E8
Open Tender
Civil Works
180 days
Charduar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (N) Tezpur
₹70,000
Yes
19 Jan 2026
21 Nov 2025
24 Dec 2025
21 Nov 2025
19 Dec 2025
5 Dec 2025
Amount
Supply, installation, testing and commissioning of silent diesel engine driven generating set outdoor type 415 V, 3 phase, 4 wire as per BS 5514/IS-10002 as per existing CPCB-IV norms complete with standard control panel, of capacity continuous rating 30 KVA/24 KW at NTP conditions with acoustic enclosure and canopy cover considering all derating factors and comprising of the following :- (a) ALTERNATOR : Self regulated with brushless self excitation 30 KVA, 415 V, 3 phase, 4 wire, 50 HZ, 0.8 P.F.,1500 RPM, with voltage variation plus or minus 2.5% of rated voltage from no-load to full-load foot mounted, screen protected drip proof type with class 'F' insulation, closed coupled single bearing alternator, with necessary controls as recommended by the manufacturers, conforming to BS-5000/IS-4772, capable of supplying unbalanced load. (b) ENGINE : Multi/cylinder,compression ignition, heavy duty,compact diesel engine liquid cooled with standard accessories, all as per BS-5514/ISO-3046,1500 RPM,control gauges, RPM/Hours meters etc; shaft H.P. suitable for generating application and capable of giving an output of 30 KVA/24 KW for coupled alternator under NTP conditions, complete with following:- (i) Flywheel housing with flywheel to suit closed coupled single bearing alternator. (ii) Air-cleaner dry type with vacuum indicator.
(iii) Fuel pump and fuel piping. (iv) Fuel filter with water separator and filter element. (v) Lub-oil filter with filter element (vi) D.C. starter 12 volts. (vii) Storage Batteries of suitable voltage and ampere-hours as recommended by the manufacturers. (viii) Residential silencer as per existing CPCB IV norms (ix) Supporting/fixing arrangement for muffler with celiling through antivibration pads. (x) Engine overspeed stop/trip switch. (xi) Radiator with fan. (xii) Dynamo for battery charging. (xiii) Corrosion inhibitor coolant. (xiv) Engine control panel electronic digital display type consisting of battery voltage indicator, lub oil temp and pressure gauges coolant water temp gauge, RPM indicator cum hour meter etc. (xv) Safety controls for alarm due to high water temp (HWT) and low lub oil pressure (LLOP). (xvi) Any other devices/accessories recommended/supplied by the manufacturers as standard eqpt. (c) SKID : The engine and alternator will be coupled,aligned and mounted on a specially designed common base frame fabricated from M.S. channels of suitable cross sectional area and length with bottom drilled holes suitable for and including supplying and fixing anti vibration pads of required size and numbers as recommended by the manufacturers for mounting of 30KVA/24KW DG set. (d) AMF PANEL : AMF panel shall be of suitable size factory outdoor cubical type front openable fabricated from CRCA steel sheet complete as per manufacturer specification of Diesel Engine suitable for DG Set of capacity 30 KVA in all respects.
Supply, installation, testing and commissioning of silent diesel engine driven generating set outdoor type 415 V, 3 phase, 4 wire as per BS 5514/IS-10002 as per existing CPCB-IV norms complete with standard control panel, of capacity continuous rating 40 KVA/32 KW at NTP conditions with acoustic enclosure and canopy cover considering all derating factors and comprising of the following :- (a) ALTERNATOR : Self regulated with brushless self excitation 40 KVA, 415 V, 3 phase, 4 wire, 50 HZ, 0.8 P.F.,1500 RPM, with voltage variation plus or minus 2.5% of rated voltage from no-load to full-load foot mounted, screen protected drip proof type with class 'F' insulation, closed coupled single bearing alternator, with necessary controls as recommended by the manufacturers, conforming to BS-5000/IS-4772, capable of supplying unbalanced load. (b) ENGINE : Multi/cylinder,compression ignition, heavy duty,compact diesel engine liquid cooled with standard accessories, all as per BS-5514/ISO-3046,1500 RPM,control gauges, RPM/Hours meters etc; shaft H.P. suitable for generating application and capable of giving an output of 40 KVA/32 KW for coupled alternator under NTP conditions, complete with following:-
(i) Flywheel housing with flywheel to suit closed coupled single bearing alternator. (ii) Air-cleaner dry type with vacuum indicator. (iii) Fuel pump and fuel piping. (iv) Fuel filter with water separator and filter element. (v) Lub-oil filter with filter element (vi) D.C. starter 12 volts. (vii) Storage Batteries of suitable voltage and ampere-hours as recommended by the manufacturers. (viii) Residential silencer as per existing CPCB IV norms (ix) Supporting/fixing arrangement for muffler with celiling through antivibration pads. (x) Engine overspeed stop/trip switch. (xi) Radiator with fan. (xii) Dynamo for battery charging. (xiii) Corrosion inhibitor coolant. (xiv) Engine control panel electronic digital display type consisting of battery voltage indicator, lub oil temp and pressure gauges coolant water temp gauge, RPM indicator cum hour meter etc. (xv) Safety controls for alarm due to high water temp (HWT) and low lub oil pressure (LLOP). (xvi) Any other devices/accessories recommended/supplied by the manufacturers as standard eqpt. (c) SKID : The engine and alternator will be coupled,aligned and mounted on a specially designed common base frame fabricated from M.S. channels of suitable cross sectional area and length with bottom drilled holes suitable for and including supplying and fixing anti vibration pads of required size and numbers as recommended by the manufacturers for mounting of 40 KVA/32 KW DG set.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.3 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 25x4mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion and taking down complete Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
Excavation in trenches not exc 1.5m in width and 1.5 M in depth and getting out excavated soil soft/loose soil.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm
Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and lay River sand cushioning spreading levelling for cable trenches all as specified and directed (Punned thickness only shall be measured and paid)
Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable all as specified and directed by Engr-in-Charges.
Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 25 sqmm 3.5 core. Including taking dwon complete all as specified and directed
NOTES: 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. The rates for RCC/PCC shall deemed to include the cost of formwork, shuttering etc., required for complete and proper execution of the item. Refer Schedule "A" notes for details.
M/s.Sai Agency (BID ID -3493274)
M/S L N ENTERPRISE (BID ID -3492311)
ANIL RAI AND COMPANY (BID ID -3490847)
MONA GENERATOR SEVICES PVT. LTD. (BID ID -3496014)
M/s Brahamaputra Wood Industries (BID ID -3495884)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
95tenderdocus.pdf
Tender Documents • 1.39 MB
BOQ_829748.xls
BOQ • 1.14 MB
Makes.rar
Additional Documents • 0.02 MB
Download all tender documents and submit your bid