Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹82.7 L
EMD Value
₹1.2 L
Closing Date
26 Sept 2022, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Sundernagar
Providing laying jointing and testing of Rising mains pumping machinery with allied accessories for Zone No 2 Batwara
2022_HPIPH_65106_1
EE JSD SNR TA eTender 2022-9769-99 dt. 16.09.2022
Open Tender
Civil Works - Water Works
Item Rate
365 days
Sundernagar
Please refer Tender documents.
8 documents required · 8 mandatory
₹800
EE Sundernagar
₹1.2 L
Yes
4 Oct 2022
16 Sept 2022
27 Sept 2022
16 Sept 2022
26 Sept 2022
16 Sept 2022
Amount
Excavation in foundation, trenches ( for pipes & pits) upto all depths in all classification of earth work such as pick work, jumper work, saturated soil including bailing and pumping out water, blasting soft/ hard rock or chieselling soft/hard rock where blasting is prohibited in all lifts including trimming and dressing of sides, leveling of beds to correct grade i/c shoring /strutting , planking, timbering & dewatering wherever required, stacking the useable & unuseable material /soil separately & after laying jointing & testing of pipes, returning the useable soil in trenches in 15 cm layers including consolidating of each deposoited layer by ramming & watering & then disposing of all surplus excavated soil /unusable material as directed with in all leads & lifts including restoration unmetalled surfaces to its original condition & including cost of diversion for traffic, night signals, fixing caution boards, crossing over trenches for access to houses, fencing etc. complete in all respects with in all leads & lifts as per directions of Engineer-in-charge.
Providing , laying,jointing ( by way of circumfrential butt welded joints in three layers by electrical arc welding ) and testing of API pipe of following dia meters confirming to ISO 3183-2012, steel grade L-290 of following class ERW (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, beds etc. as per site requirement made from parent tubes . The laying of pipe shall include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per IS:4736-1986 (with upto date ammendments) with mass of zink coating not less than 400 Kg/m2. The welding electrodes shall be as per IS 814:2004 of Advani Oerlikon/ L&T or ISI marked make. Negative tolerance in thickness and mass/weight of pipes will not be accepted. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer-in-charge with in all leads and lifts. (Earth work in trenches shall be measured and paid for separately) (i) 100mm dia API pipe 6.20mm wall thickness (L290x42 grade) Ist and 2nd phase
(ii) 100mm dia API pipe 5.20mm wall thickness (L290x42 grade) Ist and 2nd phase
(ii) 100mm dia API pipe 4.80mm wall thickness (L290x42 grade) Ist and 2nd phase
Laying,jointing ( by way of circumfrential butt welded joints by electrical arc welding in three layes) and testing of pipes of following dia meters confirming to BIS 1239 (Part-1), grade specified below (latest with upto date amendments) having wall thickness as specified below with bevelled ends and capable of withstanding required test pressure in a random length of 4 to 7 meters, including manufacturing reducers/ tapers , all short pieces, bends, Tee etc. as per site requirement made from parent tubes . The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing complete to the best satisfaction & direction of Engineer in charge with in all leads and lifts. (Earth work in trenches will be measured and paid for separately) (i) 100mm dia GI pipe 4.50mm thickness (MG) for Booster stage
(ii) 100mm dia GI pipe 5.40mm wall thickness (HG)
(iii) 100mm dia GI pipe 4.50mm wall thickness (MG)
(iv) 40mm dia GI pipe 4.00mm wall thickness (HG)
(v) 40mm dia (MG) class 3.20 wall thickness (MG)
Supply of submersible pumping set of any approved make ,approved by Jal Shakti Vibhag such as KSB/CALAMA/BS/JOHNSION/ Oswal etc. conforming to latest relevant BIS code. The pump should be fitted with free flow impellers of bronze/suitable alloy as per BIS 5659-1972 latest suitable for clear water of IS: 5659-1970 having greased packed bearing and shaft with bound stator on motor side & with shaft protection sleeve on pump side ensuring better life for shaft conforming to BIS specifications. The pump shall be directly coupled to a submersible squirrel cage electric induction motor(water proof) of reputed makeapproved by Jal Shakti Vibhag such as Kirloskar/ NGEF/Jyoti/Crompton make conforming to BIS 9283-1979 latest with upto date ammendments totally dust & water proof for submersible duty isolated from the pump by intermediate casing with double mechnical seal in oil chamber & grease packed lubricated bearing & provided with stainless steel thrust bearing plate to withstand non vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with heating of motor. The pump set should include starters, water level guards errection clamps, cable clips & depth gauge etc. & suitable for operationof pumping macninery (i) Total head 13.21 mtr. Disharge 4.41 LPS 2sets (one standby) Booster stage. (data sheet and technical specifications attached)
Supply Installation Testing & Commissioning of horizontal spindle,horizontal/redial split casing/end suction(Back-pull out arrangements) single/double/multi stage star rated centrifugal pump or combination of pumps, of recommended make or any approved make approved by jal Shakti Vibhag such as Mather and Platt/KSB/ Beacon Weir/Kirlosker/BE/Jyoti or any approved make as per BIS 1520-1980 with upto date ammendments, read with IS:9137-1978 or latest edition suitable for lifting water having turbidity upto 4000 ppm for under mentioned characterestics with bronze,impellers/priming funnels,casing ring and shaft sleeves of bronze,shaft of steel grade 45C8/ EN8 with cast iron casing coupled directly through a flexible coupling on a common MS Base Plate to squirrel cage TEFC Energy efficient motors ( Conforming to energy efficiency code IE2 or higher ) of standard make or any approved make, approved by Jal Shakti vibhag such as Kirloskar /BHEL /CG POWER /Siemens /Jyoti /ABB /Marathon and suitable for operation on 415 (+10% ) and ( -10% ) volts, 50 cycles / second, 3 phase AC electric supply. The power of electric motor/motors should be at +10% in excess of the maximum power required by the pump/pumps in the operation range of (+) 10% and (-)15% of the duty poiint head. The motor/motors as per ISI:325:1978 with upto date ammendments read with IS 900:1972. It should include cost of bearing nuts , bolts and painting etc. and should meet the following requirements: including Pump sets (working + standby ), necessary piping for suction, delivery & common header, alongwith electrical control panel with soft starters; as per requirement of pumping machinery; Complete work inclusive of all taxes,transportation, freight charges, inspection charges, loading, unloading, conveyance to Departmental stores / site, stacking, etc. including specials and wastage etc. It shall include providing and fixing of C.I/C.S Sluice valves of approved make and appropriate class to resist the design pressure and complete as per Tender Specifications and instruction of Engineer in charge. Total head 623.68 mtr. dishcarge =4.42 LPS 2 sets (one standby) for Ist stage (data sheet and technical specifications attached)
(ii) Total head 282.98 mtr. dishcarge =1.43 LPS 2 sets(one standby) for 2nd stage data sheet attached
Raman Thakur Govt. Cont.
puneet angra
SB Trading company
competent associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .