| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC 125 SHIVAJI NAGAR SAVARKUNDLA SAVARKUNDLA GUJARAT 364515 | AMRELI | GUJARAT | 364515 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹9.2 L+₹49,847 (5.72%)Rejected-Finance 30 DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-Finance Higher Quoted
Rate | |
| 3 | L3₹9.4 L+₹70,310 (8.07%)Rejected-Finance 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance Highest Quoted
Rate | |
| 4 | Rejected-Technical P O ARANGHATA DIST NADIA | ARANGHATA | NADIA | WEST BENGAL | - | Rejected-Technical As per Technical Evaluation Summary Documents. | |
| 5 | Rejected-Technical 13 BALARAM BOSE GHAT ROAD BHOWANIPUR KOLKATA 700025 | KOLKATA | KOLKATA | WEST BENGAL | 700025 | - | Rejected-Technical As per Technical Evaluation Summary Documents. |
Tender Value
Refer Docs
EMD Value
₹19,451
Closing Date
7 Jan 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, PWD, Kolkata Electrical Circle
P-16,India Exchange Place Extn. KIT Building, 2nd Floor, Kolkata-700073
Internal EI work for Plant Tissue Culture Lab at the 2nd floor of Kolkata Bio-tech Park, EN-24, Sector-V, Salt Lake, Kolkata-700091.
2021_WBPWD_357767_1
PWD/SE/KEC/NIT-06/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
SALT LAKE, KOLKATA
Please refer Tender documents.
8 documents required · 8 mandatory
₹19,451
16 Feb 2022
24 Dec 2021
10 Jan 2022
24 Dec 2021
7 Jan 2022
3 Jan 2022
120 days
Amount
Supplying and fixing double door 6 way Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to GS. including S & F following- Incoming-160A, 25KA MCCB FP Outgoing-63A, 10KA, C curve TP MCB (Make-Legrand/Siemens/ABB)
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment-for 6 way VTPN DB. (Make-Legrand/Siemens/ABB)
Supply & Laying of XLPE/PVC armoured cable of 4 core 95 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. (Make:Gloster/Ploycab/Havells/RR Kabel)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured 4 core 95 sqmm aluminium cable.
Finishing the end of 4 Core 95 sqmm XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
Supply & fixing 415 V, 16-32 Amp per way, 6 Way HTPN MCBDB with SS encloser Double door with IP-42/43 protection with four pole M.C.B as incomer and SP MCBs ('C' curve 10 KA) as outgoing, concealed in wall after cutting the wall and mending good the damages to original finish incl. interconnection with suitable size of copper wire and neutral link and provision for earthing attachment as to GS. including S & F following (a) 63 Amp four pole M.C.B and 10-32A SP MCB -- 18 nos. Make-(Legrand/Siemens/ABB)
Supply & Laying of armoured cable from 4 core 35 sqmm on wall/surface incl.S&F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting. (Make: Ploycab/Havells/RR Kable)
Finishing the end of XLPE/PVC armoured 4 core 35 sqmm cable by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials:
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured 4 core 35 sqmm cables.
Supplying and fixing double-door 2+12 way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as to GS. a) 40A DP MCB and 10-16A SPMCB (Make-Legrand/Siemens/ABB)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire ((Finolex/RR Kable/Polycab/Havells) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required (a) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
Do----Do-----Do-----Do (b) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Do----Do-----Do-----Do (c) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. (i) 6 sqmm
Do----Do-----Do-----Do (ii) 4 sqmm
Do----Do-----Do-----Do (iii) 2.5sqmm
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket , with 16A modular type switch, without plug top on 4 module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For Power Plug) (Make -Approved by EIC)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug top with indicator (Make:Approved by EIC) & necy. Connections.
S&F of A.C Power unit by switch type starter module having automatic volt,amp check facilities on 4 module G.I box. OLP30(Make- Electron)
Supply and installation, testing, commissioning of 250V Timer DB (8 Way SPN DB), with steel sheet enclosure double door , neutral bar , Din rail comprising with 1 no. 20A/25A DP MCB ('C' curve 10KA) 1 no. 24 hours Programmable eletronic timer with time range from 0.1 sec-999 hrs. and confirming IEC standards 61812-1 and IEC 60947-5-1 . No. 18A/20A conector (3RT20 type) Single phase screw type motor starter (compact 25A Pin) complete with internal wiring by sutiable size of copper wire including 1 no. Manual bypass toggle switch and provision for earthing attachment including 1 LED indication light 16 mm dia , for running condition with locking arrangement (For 1.5/2.0 TR AC m/c). (Make-Siemens or equivalent)
S & F Recessed Round LED Ceiling Light having lumen output not less than 1200 lumen and efficiency not less than 90 lumen per watt (6500K) mounted on false ceiling with necessary Connection. LED fitting should be warrented for 3 years by the Manufacturer. Necessary unconditional on site warranty document from the manufacturer should be uploaded. LM-79 & LM-80 Test Report/Certficate from the Manufacturer should be uploaded. (Make-Philips/Wipro/Syska)
S & F (2'x2') LED suitable for recess mounting fittings having lumen output not less than 3000 lumen and efficiency not less than 120 lumen per watt with necessary accessories and connection. LED fitting should be warrented for 3 years by the Manufacturer. Necessary unconditional on site warranty document from the manufacturer should be uploaded. LM-79 & LM-80 Test Report/Certficate from the Manufacturer should be uploaded. (Make-Philips/Wipro/Syska)
Supply and Fixing of industrial box type sheet metal single LED tube light fitting with LED tube lamp suspended 25cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG)supports fixed with “L” type MS clamp whose one side fixed onceiling with sutable size 4 nos. fastener and other side connectedwith the conduit with suitable size of bolts and nuts incl. S&F EIconduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. Lumen output not less than 2000 lumen and lumen efficiency not less than 100 lumen per watt. LED fitting should be warrented for 3 years by the Manufacturer. Necessary unconditional on site warranty document from the manufacturer should be uploaded. LM-79 & LM-80 Test Report/Certficate from the Manufacturer should be uploaded. (Make-Philips/Wipro/Syska)
S & F 400 mm sweep wall mounting metal body bracket fan on HW board as per direction of EIC (Make- EPC/ Orient/Usha)
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex/Havells/Polycab/RR Kabel) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. {PVC Rigid Conduit 'FR' (ISI Marked) on wall/ceiling with Modular type Switch.} (a) Average Run- 11 Mtr
Do----Do-----Do-----Do (b) On Board
Supply & fixing 250 Volt of modular type (12 module) plug socket computer board of comprising of lowing accessories. 16A switch & socket -- 1 (one) set(s) 6A switch & socket - 2 (two) set (s) Including necessary interconnection by PVC insulated copper wire flusheed in wall. (make :Approved by EIC)
S&F industrial plug and socket board with 240V,32A, DP MCB and earth metal industrial plug socket and 32A industrial top incl. S&F 32A DP MCB breaking capacity 10kA (C -curve) in SS enclosure fixed on wall and necy. Connection. (Make- Legrand/Siemens/ABB)
Supply & fixing industrial type exhaust fan after cutting wall & mending good the damages to original finish including supply & fixing GI louver shutter as follows. 12 inch, 1420 rpm, approx 85watt. (Make EPC/Usha/Crompton Greaves) N.B: (a) The Agency must procure the materials from the Manufacturer / OEM or from their authorized. Sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Necessary warranty certificate from the manufacturer for BOQ Item Sl. No. 17.00, 18.00 & 19.00 should be uploaded, failing which bid may be rejected. (b) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill. (c) If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
S. A. ENTERPRISE
M/s Singh Electrical Works
stage.html
html • 0.05 MB
technical_691573.pdf
PDF • 0.08 MB
techsummary_691573.pdf
PDF • 0.08 MB
finance_691573.pdf
PDF • 0.08 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_691573.pdf
PDF • 0.08 MB
AOC-NIT06-21-22.pdf
PDF • 0.58 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .