Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC | ₹1.1 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹1.2 LRejected-AOC | ₹1.2 L | L2 | Rejected-AOC Second Lowest bidder |
| Sl No | Description | Qty | Unit | M P SUBASH L1 | candelaengineering corporation L2 |
|---|---|---|---|---|---|
| 1.00wiring of server room | |||||
| 1.01 | 90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm | 170 | Metre | 120 ₹20,400 | 128 ₹21,760 |
| 1.02 | 90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm | 10 | Metre | 130 ₹1,300 | 143 ₹1,430 |
| 1.03 | 90.2.1.1
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose
- Short point | 3 | point | 1,000 ₹3,000 | 950 ₹2,850 |
| 1.04 | 90.2.1.3
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | 5 | point | 950 ₹4,750 | 855 ₹4,275 |
| 1.05 | 90.2.1.4
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | 1 | Point | 1,550 ₹1,550 | 1,700 ₹1,700 |
| 1.06 | 90.2.1.5
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point | 1 | Point | 1,100 ₹1,100 | 980 ₹980 |
| 1.07 | 90.2.1.6
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | 2 | each | 500 ₹1,000 | 555 ₹1,110 |
| 1.08 | 90.2.1.7
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point | 1 | each | 700 ₹700 | 720 ₹720 |
| 1.09 | 1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm | 80 | Metre | 80 ₹6,400 | 85 ₹6,800 |
Tender Value
Refer Docs
EMD Value
₹2,900
Closing Date
23 Apr 2026, 3:00 pmClosed
Executive Engineer Electrical
Power House,Sreepadmam, Guruvayur Devaswom, Guruvayur
GENERAL-Server Room and Audit Room Wiring-Wiring of newly constructing server room for e-Office and new Cabin of Deputy Director of Kerala state audit office-General Electrical Work
2026_GD_848501_1
E3-5546/2025
Open Tender
Electrical Works
30 days
Guruvayur
Please refer Tender documents.
4 documents required · 4 mandatory
₹560
₹2,900
24 Jun 2026
16 Apr 2026
27 Apr 2026
16 Apr 2026
23 Apr 2026
16 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1wiring of server room | |||||
| 1.01 | 90.6.10.1
Supply and fixing of following sizes of light gauge PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm | - | Metre | - | - |
| 1.02 | 90.6.10.2
Supply and fixing of following sizes of light gauge PVC conduit along with
accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm | - | Metre | - | - |
| 1.03 | 90.2.1.1
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose
- Short point | - | point | - | - |
| 1.04 | 90.2.1.3
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point | - | point | - | - |
| 1.05 | 90.2.1.4
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point | - | Point | - | - |
| 1.06 | 90.2.1.5
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Call bell point with 6 A bell push at one end and 6 A, 3 plate ceiling rose at other end - Short point | - | Point | - | - |
| 1.07 | 90.2.1.6
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points | - | each | - | - |
| 1.08 | 90.2.1.7
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of
minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with
suitable size specials conforming to IS 3419-1988, fixing the conduit using metal
saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point | - | each | - | - |
| 1.09 | 1.17.2
Supplying and drawing following sizes of FRLS PVC insulated copper conductor,
single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm | - | Metre | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
BOQ_1433989.xls
BOQ • 0.37 MB
NIT.pdf
Tender Documents • 0.30 MB
agreementpage1.pdf
Tender Documents • 1.18 MB
Materialslist.pdf
Other Document • 0.09 MB
Agreement200Page2.pdf
Tender Documents • 0.14 MB
Download all tender documents and submit your bid