Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC | ₹6.6 L Quoted ₹6.7 L | L1 | Accepted-AOC AOC |
| 2 | L2₹6.9 L+₹20,110 (3.01%)Rejected-Finance 72 546A ERATHARA H LIBERTY LANE KALOOR PO KOCHI 682 017 | KOCHI | ERNAKULAM | KERALA | 682017 | ₹6.9 L+₹20,110 (3.01%) | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹7.4 L+₹67,460 (10.1%)Rejected-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | ₹7.4 L+₹67,460 (10.1%) | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹8.3 L+₹1.6 L (24.3%)Rejected-Finance 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | ERNAKULAM | ERNAKULAM | KERALA | 682010 | ₹8.3 L+₹1.6 L (24.3%) | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹8.9 L+₹2.2 L (33.1%)Rejected-Finance | ₹8.9 L+₹2.2 L (33.1%) | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
11 Jul 2024, 6:00 pmClosed
AGE I R AND D KOCHI
AGE I R AND D KOCHI, THRIKKAKARA,KAKKANAD, KOCHI 682021
REPAIR MAINTENANCE OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FAN AND ETC AT TECHNICAL AND RESIDENTIAL AREAS UNDER AGE I R D KOCHI
2024_MES_659505_1
8289E8AGERDK
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KAKKANAD
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹0
₹18,000
Yes
25 Apr 2025
13 Jun 2024
13 Jul 2024
13 Jun 2024
11 Jul 2024
27 Jun 2024
Amount
Taking down carefully ceiling fans from any height and of any make/ any sweep including disconnecting the cable from ceiling rose and shifting to store carry out servicing, greasing, oiling and painting of ceiling fan complete apply two coat of synthetic enamel paint (White) by spray painting using necessary machine including filling the cavities with filler one coat after cleaning all dust etc and refixing the same after servicing/Repair including replacement of necessary nut bolts as specified and as directed by the Engineer - in - Charge. Note: Major spares replaced will be measured and paid in respective items of Schedule 'A' as follows .
M & L for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height , dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing new painting to ceiling fans complete with synthetic enamel Grey paint by spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, refixing the same in original position complete all as specified and as directed by the Engineer - in - Charge. Note: Rate include the taking down the ceiling fan and deposited to MES store for checking and repairing)
All as per Item No.02 above but for the Exhaust fan of following sizes:
Exhaust fan of 300 mm sweep
Exhaust fan of 450 mm sweep
Exhaust fan of 600 mm sweep
All as per Item No.02 above but for the wall fan/Pedestal fan of size up to 600 mm sweep all as specified and as directed by the Engineer - in - Charge.
Taking down carefully exhaust fans of sweep 300/380/450 mm from any height and of any make and sweep including disconnecting the cable from ceiling rose and shifting to store for servicing and removing the old painting and providing new painting to exhaust fans complete with synthetic enamel Grey paint by spraying using machine including filling cavities with filler one coat after cleaning all dust and refixing the same in original position including necessary electrical connection making the surface in good finishes , etc all as specified and as directed by the Engineer - in - Charge.( Note: The painting should be done by machine all as specified and as directed by the Engineer - in - Charge ).
All as per item no 06 above but for exhaust fan of 600 mm sweep all as all as specified and as directed by the Engineer - in - Charge.
S & F in replacement shaft bush of any type/size for ceiling fans & exhaust fans complete all as specified and as directed by the Engineer - in - Charge.
S & F in replacement ball bearing suitable for any type/size of ceiling fans / exhaust fans/ wall fan as per the existing standard complete all as specified and as directed by the Engineer - in - Charge.
S & F in replacement rubber seal with nut, bolt, washers and split pin of existing size & shape complete all as specified and as directed by the Engineer - in - Charge.
Supply and fix in replacement louver for exhaust fan of size 225/ 300/450 mm size fixed to residential building up G + 4 floors and in Technical building including taking down existing unserviceable louvers of any size from any height all as specified and as directed by the Engineer - in - Charge .
All as per item no 11 above but for exhaust fan of 600 mm sweep all as specified and as directed by the Engineer - in - Charge
M & L for machine centre balanced blade set for 1200 mm sweep ceiling fan suitable for any make of existing ceiling fan all as specified and as directed by the Engineer - in - Charge
M & L for replace capacitor 2.5/3.15 mfd dry type with PVC clamp all as specified and as directed by the Engineer - in - Charge .
M & L for replace capacitor 4.0 mfd dry type with PVC clamp all as specified and as directed by the Engineer - in - Charge .
M & L for replacement of canopy PVC suitable for ceiling fan of any sweep all as specified and as directed by the Engineer - in - Charge
Taking down carefully old and unserviceable copper / aluminum point wiring for light/fan/socket or power point complete including fittings such as switches, ceiling rose, pendants, regulators, sockets, bell, distribution boards and MCB's etc and making good disturbed surface of walls floors etc to match with the existing surface complete all as specified and directed.
Point wiring with 1.5 sq mm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multistandard copper conductors and earth continuity wire with similar 1.5 sq mm cable (incl connecting to earth dolly) drawn through existing concealed conduit / incl rigid PVC conduit and conduit accessories concealed in wall where required by cutting grooves on existing wall except on ceiling in suitable way with clamps screw etc with and incl concealed modular box suitable for logic modular switches , sockets , etc and incl logic modular white plates of suitable size as required at site complete all as specified and directed for the following:-
One light point controlled by one No, one way switch
One ceiling Fan/Exhaust Fan point controlled by one No, one way switch
One bell point controlled by one No, bell push
One 5 Amp socket outlet point on independent board controlled by one No, one way switch
All as per item no 17 above but with 2.5 sq mm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with 2.5 sq mm cable (incl connecting to earth dolly) suitable for 15 amp socket outlet point.
S&F switch modular type, 6 amp, I module 230 volts, AC supply,50Hz complete.
S&F switch modular type, 16 amp, I module 230 volts, AC supply,50Hz complete.
S&F bell push modular type, 6 amp, I module 230 volts, AC supply,50Hz complete.
S&F socket outlet modular type, 6 amp 2 module multipurpose type 230 volts.
S&F socket outlet modular type, 6/16 amp 2 module multipurpose type 230 volts.
S&F ceiling rose PVC/polycarbonate three terminal surface bakelite complete all as specified and directed.
Supplying and fixing of following under mentioned modular white cover plate with frame.
White cover plate with frame 2 module.
White cover plate with frame 4 module.
White cover plate with frame 6 module.
White cover plate with frame 8 module.
M & L for PVC rectangular block for mounting, switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100 mm x 100mm and 50mm deep.
S&F single pole and neutral enclosure with a two pin earth plug and socket with one single pole MCB of 20 Amp.
S & F AC plug only for Geyser (Industrial Plug ) connection 20A rating upto 20A 2P,+E,230V AC.(CLAD TYPE). Make : INDOASIAN, CAT NO : 810386, or HAVELS/ANCHOR.
S & F socket only for Geyser (Industrial Socket) plug rating upto 20A 2P,+E,230V AC. Make : INDOASIAN, Cat No : 810389 or HAVELS/ANCHOR.
Supply and fixing LED light fitting 1X20W,220V high efficiency (efficiency upto 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-20-30/40/65-SL-DP-NWH
Supply and fixing LED light fitting 1X10W,220V high efficiency (efficiency upto 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-10-30/40/65-SL-DP-NWH or Luker/Havells.
Supply and fixing of LED 12w/10w LED Downlighter having high performance low height back lit downlighter suited for any modern professional workspace . Robodust PDC aluminium housing ensures long life. Available in 3000K,4000K,and 5700K CCT. Efficacy :100lm/W . Make: Crompton product no CDR-205-12-57-SL-NWH or Havels/PHILIPS.
S & F of LED 36W Recessed full lit luminaire with glare free uniform illumination with longer life and less maintenance available in 2x2 ft (> 100 lm/w). Make : Crompton, Model no LCTRNE-36-FO-WW/TL/CDL or Havels/Jaguar.
S & F LED 20W T8 Tube with in built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made og high grade polycarbonate cover,2.5 Kv internal surge protection,IP20 ingress protection, PCB mounted on extruded metal plate. Make : Crompton model no LT8-20-865-(2) or Havels/Jaguar.
Supply and fixing of Compact industrial batten LED batten fitting having housing made of CRCA pre coated sheet steel suitable for office having single polycarbonate aluminium and glass tube . Make : Crompton model no DIJB12LT-20 or Havels/Jaguar.
Supply and fixing of Compact industrial batten LED batten fitting having housing made of CRCA pre coated sheet steel suitable for office having twin polycarbonate aluminium and glass tube . Make : crompton model no IGP161LT8-20 or Havels/Jaguar.
Supply and fixing of LED 6w Surface Downlighter round and square surface mounted LED panel PDC aluminium housing and high translucent frosted plastic diffuser makes it a robust Luminaire ,Efficacy 100lm/ W . Make:Crompton product no LCDSPLN-06-CDL or Havels/PHILIPS.
Supply only 3 pin plug top 16 amp. ( for gyser connection ) Make Anchor/Havells/Crompton
M & L industrial laminated sheet board/hylem sheet of size 6 mm thick of any size for mounting switches, sockets, fan regulator, etc by punching required slots for switches/Sockets /Regulators as per site requirement including taking down the existing laminated top cover all as directed
S&F Building security light fitting LED 45 W, made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistance of IK07 with and including 0.5 sqmm flexible copper multistranded conductor cable including security light bracket made to suitable shape out of GI pipe 40 mm bore light grade, 1.5 mtr length and fixed with MS Clamps of size 40x5 mm- 02 nos ,nuts, bolts and washers on wall complete all as specified and directed. Make: Crompton Cat part No LSTV-45-CDL or equivalent of other specified makes.
S&F stepped /Socket Type electronic fan regulator flush type on the existing phenolic laminated sheet as required and as directed by Engr in Charge.
S & F fan regulator Modular type on the existing modular Plate of make, Havells (Standard &Crabtree )/ Anchor/Indoasian as per site required and as directed by Engr in Charge.
S&F MCBs 10 KA rupturing capacity , IS-8828 marked, of the under mentioned type and rating and fixing in DBs (DBs Catered separately in this Schedule) :- Note :- Make of the MCB should be the same as that of DB.
SPN 40 to 63 Amps C curve
SPN 25 to 32 Amps "C" curve
SP 06-32 Amps "B" curve
TP 40-63 Amps "B" curve
TPN 63 Amps "B" curve
Taking down the old sub main wiring and M/L for new sub main wiring with 4 run single core 6.0 Sqmm PVC unsheathed copper multistranded , FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/Ivory colour PVC conduit including multi stranded copper earth conductor 6.0 sq mm two run as earth continuity conductor all as directed by Engineer in Charge.
Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 6.0 Sqmm PVC unsheathed copper multistranded conductor, FRLS drawing into and including PVC conduit medium grade of size not less than 25 mm dia with all fittings and fixtures like L- bow, saddles etc of white/Ivory colour PVC conduit including multi stranded copper earth conductor 6.0 sq mm two run as earth continuity conductor all as directed by Engr-in-Charge.
M & L for Earthing complete with using galvanised steel earth plate 60 X 60 cm X 6 mm thick electrode , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 25 X 4 mm galvanised iron strip as earth lead by means bolts, nuts, check nuts and washers all as shown in electrical plate No.3 connected to earthing test point all as specified or indicated including testing on completion necessary complete all as specified and as directed.
Taking down the Geyser of capacity 25 / 50 Ltr including disconnecting of electric / water supply connections from building for repair / replacement of defective components and overhauling / checking, servicing , des calling of inner tank , geyser element, checking of geyser assembly and setting of thermostat range complete and refixing the same after repair and testing including making electectric and water supply connection complete all as specified and directed by Engineer-in-charge. Note:- a) All safety precautions for the safety precautions for persons working during removal/fixing back of the Geyser shall be ensured by the contractor . Rates are inclusive of brazing of inner tank of copper for prevention of leakage and replacement of clamps nut bolts gasket set complete . b) Replacement of defective components, painting,etc., which shall be measured and paid for separately.
Supply and Fixing Heating element of capacity1.5/ 2 kW (cap type / triangular / threaded type), ISI marked, suitable for geyser of capacity 25/50Ltr complete all as specified and directed by Engineer-in-charge.
Replacement of neon Indicator lamp of red and green colour lamps suitable for geyser of capacity 25/ 50 Ltr of any type / make complete all as specified and directed by Engineer – in – charge
Replacement of Thermostat assembly 16 A,240 AC, ISI marked, suitable for geyser of capacity 25/ 50Ltr of any type / make complete all as specified and directed by Engineer- in- charge .
Replacement of PVC Helical (Hot / Cold) water connection pipe of size 450 mm x 15mm dia with two no of brass nut on each side for geyser complete all as specified and directed by Engineer – in – charge
Replacement of (4 nos) ,16 mm dia nuts bolts of suitable length duly grouted in walls in cement mortar for fixing of geyser of any capacity complete all as specified and directed by Engineer – in – charge .
Replacement of Gun metal Non return valve (NRV) of size 15 mm bore ISI marked complete all as specified and directed by Engr-in-charge.
Replacement of stop valve fancy type chromium plate high pressure surface concealed with crutch of butter fly handle screwed both ends for iron pipe 15 mm bore ISI marked .
ROTECH ENGINEERS AND BUILDERS
ELAN ENGINEERS
ZOOM ENTERPRISES
ST ANTONY CONSTRUCTIONS
AR Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .