Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹28.0 LAccepted-AOC | ₹28.0 L Quoted ₹30.0 L | 1 | Accepted-AOC Awarded being the lowest tenderer |
| 2 | 2₹35.4 L+₹5.4 L (18.1%)Rejected-Finance | ₹35.4 L+₹5.4 L (18.1%) | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 3 | 3₹39.6 L+₹9.6 L (32.0%)Rejected-Finance | ₹39.6 L+₹9.6 L (32.0%) | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 4 | 4₹42.1 L+₹12.1 L (40.3%)Rejected-Finance DOOR NO 58 1 236 6 FLAT NO A 104 SAMPATH ENCLAVE NAD KOTHA ROAD VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | ₹42.1 L+₹12.1 L (40.3%) | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
| 5 | 5₹43.4 L+₹13.4 L (44.7%)Rejected-Finance DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | ₹43.4 L+₹13.4 L (44.7%) | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
10 Oct 2019, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE
GARRISON ENGINEER NAVAL BASE GANDHIGRAM POST VISAKHAPATNAM 530005
REPAIRS AND REPLACEMENT OF INTERNAL ELECTRICAL FITTINGS FIXTURES DBS SUBMAIN WIRING AT NEW NAUSENABAUGH AREA UNDER GE NB VISAKHAPATNAM
2019_MES_279427_2
GE(NB)/VIZ/TOKEN 47 of 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
VISAKHAPATNAM
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹1 L
Yes
13 Jun 2020
26 Sept 2019
12 Oct 2019
26 Sept 2019
10 Oct 2019
3 Oct 2019
Amount
M&L for point wiring with two runs of single core 1.5 Sqmm (nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore medium grade (ISI marked) concealed including MS Concealed / Semi concealed terminal Boxes made of 2 mm thick MS sheet covered with 3 mm thick laminated sheet including cutting of stone masonry / wall for fixing switches, sockets, regulators etc. including provision of multistranded 1.5 Sqmm. copper conductor as earth wire connected to common earth dolly and earth in distribution board, including tee bend, elbows, junction boxes etc including taking down existing point wiring along with fittings and fixtures complete all as specified and as directed, for one light//fan point/ bell point controlled by one way switch complete all as specified and as directed.
All as per item No. 1.00 above but for One light point controlled by two way switch complete all as specified and as directed.
All as per item No. 1.00 above but for One 3 pin socket outlet 6 amps on independent board complete all as specified and as directed.
All as per item No. 1.00 above but for One 3 pin socket outlet 6 amps point on same board complete all as specified and as directed.
All as per item No. 1.00 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable as earth lead complete all as specified and as directed.
M&L for Sub main wiring with 4 runs of Single core 10 sqmm [ for phase and & Neutral ] PVC insulated multi stranded FRLS copper cable drawn through PVC conduit of 32mm bore with accessories along with 1 run of single core 10 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring complete all as specified and as directed. Note :- Four runs of 10 sqmm and one run of 10 sqmm cable as earth along with PVC conduit will be measured as one length.
M&L for Sub main wiring with 4 runs of single core 6 sqmm [for phase and& Neutral ] PVC insulated multi stranded FRLS copper cable drawn through PVC conduit of 25mm bore with accessories along with 1 run of single core 6 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring complete all as specified and as directed. Note :- Four runs of 6 sqmm and one run of 6 sqmm cable as earth along with PVC conduit will be measured as one length.
M&L for Sub main wiring with 2 runs of single core 6 sqmm [for phase and Neutral ] of PVC insulated multi stranded FRLS copper cable drawn through PVC conduit of 25mm bore with accessories along with one run of single core 6 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring complete all as specified and as directed. Note :- Two runs of 6 sqmm and one run of 6 sqmm cable as earth along with PVC conduit will be measured as one length.
M&L for Sub main wiring with 2 runs of single core 4 sqmm [for phase and Neutral ] PVC insulated multi stranded FRLS copper cable drawn through PVC conduit of 25mm bore with accessories along with one run of single core 4 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring complete all as specified and as directed. Note :- Two runs of 4 sqmm and one run of 4 sqmm cable as earth along with PVC conduit will be measured as one length.
M&L for Sub main wiring with 2 runs of single core 2.5 sqmm [for phase and Neutral ] PVC insulated multi stranded FRLS copper cable drawn through PVC conduit of 25mm bore with accessories along with one run of single core 2.5 sqmm copper cable as earth continuity conductor including taking down the existing submain wiring complete all as specified and as directed. Note :- Two runs of 2.5 sqmm and one run of 2.5 sqmm cable as earth along with PVC conduit will be measured as one length. [i] Note for Item No. 1 to 10 : MAKE :(i) CABLE : FINOLEX, PLAZA, POLYCAB/HAVELLS/GLOSTER/HARSH [ ALL ARE ISI MARKED FRLS CABLES ] (ii) PVC CONDUIT : AVON PLAST / GARWARE PLASTICS/ TENCOS LTD/KALINGA/FINOLEX / PRECISION [ ALL ARE ISI MARKED]. [iii] Note 2 : The rate quoted is deemed to include making good the disturbed sufaces and finish to match with the adjoining surface.
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. Make : Anchor / Cona / Bajaj
S&F in repairs ceiling rose surface bakelite 65 X 50mm two to three terminals complete all as specified and as directed. Make : Cona / Anchor / Legrand
S&F in repairs Stepped type electonic fan regulator flush type on the existing phenolic laminated sheet complete all as specified and as directed. Make : Anchor(Roma)/Legrand/MK
S&F in repair fan capacitors of 2.5 Mfd complete all as specified and as directed. Make : Havells/USHA/TIBCON
S&F in repairs Socket outlet 2 in 1, 3 pin, 5 Amps, flush type. complete all as specified and as directed. Make : Anchor / Bajaj / Cona Note : Taking down of socket outlet included in taking down point wiring
S&F in repairs Socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed. Make : Anchor / Bajaj / Cona Note : Taking down of socket outlet included in taking down point wiring
S&F in repairs Switch socket combination 2 in1, 3 pin, 5 Amp flush type,universal complete all as specified and as directed. Make : Anchor / Bajaj / Cona Note : Taking down of socket outlet included in taking down point wiring
S&F in repairs Switch socket combination 2 in1, 3 pin,5 and 15Amp flush type,universal complete all as specified and as directed. Make : Anchor / Bajaj / Cona Note : Taking down of socket outlet included in taking down point wiring
S&F in repairs Modular Fan regulator, 2 Module, complete all as specified and as directed. Make : ABB of model No. CPW2SFR5 or equivalent in Roma/MK/Legrand.
S&F in repairs switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed. Make: MK/Anchor (Roma)/ABB/Legrand
S&F in repairs switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed. Make: MK/Anchor (Roma)/ABB/Legrand
S&F in repairs Modular socket 6A - 2/3 pin combined 2 module, complete all as specified and as directed. Make: Legrand/ MK/Anchor (Roma)/ABB
S&F in repairs Modular socket 6A /16A- 2/3 pin combined 2 module, complete all as specified and as directed. Make:Legrand/ MK/Anchor (Roma)/ABB
S&F in repairs Modular white cover plate with frame, but 1 module complete all as specified and as directed Make: ABB/MK/Roma
S&F in repairs Modular white cover plate with frame, but 2 module complete all as specified and as directed Make: ABB/MK/Roma
S&F in repairs Modular white cover plate with frame, but 3 module complete all as specified and as directed Make: ABB/MK/Roma
S&F in repairs Modular white cover plate with frame, but 4 module , complete all as specified and as directed Make: ABB/MK/Roma
S&F in repairs Modular white cover plate with frame, but 6 module complete all as specified and as directed . Make: ABB/MK/Roma
S&F in repairs Modular metal flush box, but 1/2,3 module complete as specifed and as directed. Make : ABB/MK/Roma
S&F in repairs Modular metal flush box, but 4 module , complete as specifed and as directed. Make : ABB/MK/Roma
S&F in repairs Modular metal flush box, but 6 /8 module complete as specifed and as directed. Make : ABB/MK/Roma
S&F in repairs switch piano Flush type, single pole one way 6 amp 240 volts, complete all as specified and as directed . Make: Anchor / Bajaj / Cona
S&F switch piano Flush type, single pole one way 16 amp 240 volts, omplete all as specified and as directed Make: Anchor / Bajaj / Cona
S&F in repairs switch piano Flush type, single pole two way 6 amp 240 volts, omplete all as specified and as directed Make: Anchor / Bajaj / Cona
S&F in repairs bell push flush type, 6 amp 240 volts,omplete all as specified and as directed Make: Anchor / Bajaj / Cona
S&F in repairs in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed . Make: Anchor / Bajaj / Cona
S&F in repairs Buzzer electric, AC 230 Volts, single pole., complete all as specified and as directed . Make: Anchor / Bajaj / Cona
S&F in repairs Distribution Board, TPN, 8 way, Double door complete all as specified and directed. Make : Indo Asian Cat Part No. 811844 [ Optipro] /Standard/Havells / C & S cat part No. CSDBTPNHPDD08
S&F in repairs Distribution Board, TPN, 6 Way, Double door complete all as specified and directed. Make : Indo Asian Indo Asian Cat Part No. 811843 [ Optipro] /Standard/Havells / C & S cat part No. CSDBTPNHPDD06
S&F in repairs Distribution Board, TPN, 4 Way, Double door complete all as specified and directed. Make : Indo Asian Indo Asian Cat Part No. 811841 [ Optipro] /Standard/Havells / C & S cat part No. CSDBTPNHPDD04
S&F in repairs Distribution Board, SPN 12 Way, Double door complete all as specified and as directed. Make : Indo Asian cat part No. 811808[Optipro] / Standard / Havells / C & S cat part No. CSDBSPNPDD12
S&F in repairs Distribution Board, SPN 8 Way ,Double door complete all as specified and as directed. Make : Indo Asian cat part No. 811807 [Optipro] / Standard / Havells / C & S cat part No. CSDBSPNPDD08
S&F in repairs Distribution Board, SPN 4 way ,Doble door All as specified and as directed. Make : Indo Asian cat part No.811805 [Optipro] / Standard / Havells / C & S cat part No. CSDBSPNPDD04
S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, B curve, complete all as specified and as directed. Make: Indo Asian Cat part No. 811008 to 811015 / STANDARD / HAVELLS / C & S cat part No. CSMBSIB6 to 32 Amps
S & F in repairs MCB SPN 6-32A Amps 240 Volts B curve, complete all as specified and as directed. Make: Indo Asian Cat part No. 811144 to 811551 / STANDARD / HAVELLS / C & S cat part No. CSMBSIB6N to 32N Amps
S & F in repairs MCB, SPN 40 Amps C Curve 240 Volts, complete all as specified and as ditrected . Make: Indo Asian Cat part No. 811152 / STANDARD / HAVELLS / C & S cat part No. CSMBS1C40N
S & F in repairs MCB, TPN 40 Amps 415 Volts complete all as specified and as ditrected . Make: Indo Asian Cat part No. 811218 / STANDARD / HAVELLS / C & S cat part No. CSMBS3C40N
S & F in repairs MCB, TPN 63 Amps 415 Volts , complete all as specified and as ditrected . Make: Indo Asian Cat part No. 811219 / STANDARD / HAVELLS / C & S cat part No. CSMBS3C63N
S & F in repairs MCB, TP 40 Amps 415 Volts, complete all as specified and as ditrected . Make : Indo Asian Cat Part No. 811196 [ Optipro] /Standard/Havells/HPL / C & S cat part No. CSMBS3C40
S & F in repairs Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V complete all as specified and as directed. Make : Indo Asian / Standard / Havells / C & S
S&F in repairs of single core 1.5 Sqmm size cable (nominal area) PVC insulated unsheathed multistanded FRLS copper conductor cable 1100 Volts ISI marked drawn through existing conduit including taking out unserviceable cable from point wiring complete all as specified and as directed.
All as per item No. 51 above but of cable size 2.5 Sqmm size cable complete all as specified and as directed .
All as per item No. 51 above but of cable size 4sqmm complete all as specified and as directed.
All as per item No. 51 above but of twin core, PVC insulated, unsheathed, multistranded copper flexible conductor cable, 1100 vols grade ISI marked of size 0.75 sqmm complete all as specified and as directed. Note for Item No. 51 to 54: (i) Make:Finolex/Havells/Gloster/Polycab/Plaza [ All are FRLS cables and ISI Marked ] (ii) Rate quoted are to be included for taking down the existing unservicable cable.
S&F in repairs MCCB 415 Volt 16 KA 4 Pole 63 Amps Capacity complete all as specified and as directed . Make : Havells/Indoasian/Legrand / C & S
S&F in repairs MCCB 415 Volt 25 KA 4 Pole 100 Amps Capacity complete all as specified and as directed . Make : Havells/Indoasian/Legrand / C & S
S&F in repairs MCCB 415 Volt 25 KA 4 Pole 125 Amps Capacity complete all as specified and as directed . . Make : Havells/Indoasian/Legrand / C & S
S&F in repairs MCCB 415 Volt 36 KA 4 Pole 160 Amps Capacity complete all as specified and as directed. . Make : . Make : Havells/Indoasian/Legrand/ Standard / C & S
S&F in repairs MCCB 415 Volt 36 KA 4 Pole 200 Amps Capacity complete all as specified and as directed. Make : Hager/Standard/Indoasian/Havells / C & S
S&F in repairs MCCB 415 Volt 36 KA 4 Pole 250 Amps Capacity complete all as specified and as directed. Make : Hager/Standard/Indoasian/Havells / C & S
S&F in repairs MCCB 415 Volt 36 KA 4 Pole 400 Amps Capacity complete all as specified and as directed. Make : Hager/Standard/Indoasian/Havells / C & S
S&F XLPE insulated armoured heavy duty LT electric cable with aluminium conductor of 1100 volts grade cross- sectional area 16 Sqmm size cable of 4 core including taking down existing cable including necessary excavation and earth work etc as required complete all as specified and as directed. Make : HAVELLS / POLY CAB / NICCO / ASIAN
S&F XLPE insulated armoured heavy duty LT electric cable with aluminium conductor 1100 volts grade cross- sectional area 25 Sqmm size cable of 3.5 core including taking down existing cable including necessary excavation and earth work etc as required complete all as specified and as directed. Make : HAVELLS / POLY CAB / NICCO / ASIAN
S&F in repairs 3mm thick hylam sheet cover of size 6x4" for fixing switches, sockets regulator etc complete all as specified and as directed.
S&F in repairs 3mm thick hylam sheet cover of size 6x6" for fixing switches, sockets regulator etc. complete all as specified and as directed.
S&F in repairs 3mm thick hylam sheet cover of size 10x8" for fixing switches, sockets regulator etc. complete all as specified and as directed.
S&F 3mm in repairs thick hylam sheet cover of size 12x10" for fixing switches, sockets regulator etc. complete all as specified and as directed.
Taking down carefully old and UNSV Single phase meter any type or capacity and making good the disturbed surface to match with the existing surfaces/walls etc all as specified and directed and S&F in repairs Single phase electronic meters 10-40 Amps, CT operated (LCD Display), 230 Volts totally tamper proof, with tamper and fraud detection and recording with snapshot, high accuracy and operation at very low load complete all as specified and as directed Make : Benlo Cat Part No BESPLCD10-40 or equivalent to Bajaj/Havell's/CG.
Repairs to Panel board indoor type sheet metal approximate szie (5 x1.5 x 1.5 Feet's) parts tinkering the parts and replacing fully corroded sheet metal parts like base plate, top plate, front cover etc with appropriate gauges MS sheet including bending to match with the existing size, welding brazing and assembling including replacing all nuts & bolts in MCBs and proper legging in cable and control wire sheet metal screws metal screws and painting the complete body with two coat of synthetic enamel paint over a coat of Zinc chrome primer and marking the Qtr No, Panel Board No in front side and all as specified and as directed .
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm c/c reinforcement both ways, with MS handle 12mm dia and frame watering funnel, 20 mm dia light grade for protection of earth electrode 20 mm dia for watering all as shown in electric plate No 3 in page 497 of SSR Part I (2009) and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and also removal of excavated soil to a distance not less than 50 mtr from the earthing place all as specified and directed and tested on completion.
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI strip 25 x 4mm (up to 7.5 m in length from earth plate) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm c/c reinforcement both ways, with MS handle 12mm dia and frame watering funnel, 20 mm dia light grade for protection of earth electrode 20 mm dia for watering all as shown in electric plate No 3 in page 497 of SSR Part I (2009) and pouring extra Clay Soil of qty not less than one cubic meter into the earth pit and also removal of excavated soil to a distance not less than 50 mtr from the earthing place all as specified and directed and tested on completion.
S&F Aluminium strip of size 25x3.15 mm for lightning conductor (roof conductors)/down conductors) laid in trench/floor including necessery clamps,nuts,bolts and hylem sheet block complete all as specified and as directed.
S&F in repairs GI strip of size 25x4mm for lightning conductor laid in trench / floor including necessery clamps, nuts, bolts and hylem sheet block complete all as specified and as directed.
S&F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long and fixed complete all as specified and as directed.
Fixing in repairs to old existing Aluminium strip/copper strip of any size with saddles and fixing screws etc (same existing )for roof conductor and down conductors above ground.
S&F in repairs Test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 nos 125mm long hexogonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed.
TECHNO SOFT SOLUTIONS
SOHAN ENGINEERING ASSOCIATES
M/S EVEREST INFRA
Mavee Syndicate
VARADHI ENTERPRISES
KANAKAJYOTHI ENTERPRISES
SRIKRISHNACONSTRUCTIONS
NIKESH ENTERPRISES
SRI SAI VAGDEVI BUILDERS
VASISHTA ASSOCIATES
KIRON ENGINEERING CORPORATION
SAMPATH ENTERPRISES
V RAMESH BABU AND COMPANY
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .