Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-Finance AMETHIA NAGAR NAMKUM RANCHI | RANCHI | JHARKHAND | 829205 | ₹49.2 L | L1 | Accepted-Finance L-1 Bidder |
| 2 | L2₹49.6 L+₹34,313 (0.70%)Rejected-Finance AT UPPER BOOTY NEAR KRISHNA NURSING HOME P S SADAR RANCHI JHARKHAND 835217 | RANCHI | JHARKHAND | 835217 | ₹49.6 L+₹34,313 (0.70%) | L2 | Rejected-Finance L-2 Bidder |
| 3 | L3₹50.2 L+₹99,042 (2.01%)Rejected-Finance FLAT NO 02B GAMHARIA SAWARNA PALACE TATA KANDRA MAIN ROAD VILLAGE TOWN GAMHARIA CITY JAMSHEDPUR SERAIKELA KHARSAWAN JHARKHAND 832108 INDIA | SARAIKELA KHARSAWAN | JHARKHAND | 832108 | ₹50.2 L+₹99,042 (2.01%) | L3 | Rejected-Finance L-3 Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical EMD not submitted |
Tender Value
₹49.2 L
EMD Value
₹99,000
Closing Date
18 Aug 2026, 1:00 pmClosed
General Manager
Transmission Zone-VIII, Chaibasa, Tata By-Pass Road, Sikursai, Chaibasa, District-West Singhbhum, Pin- 833201, Jharkhand
Complete overhauling work of Kanohar make 150 MVA, 220/132 KV AUTO transformer no. 2 (Sl. N.-KT 150000/5) and 132/33 KV 50 MVA Power Transformer no. 2 (S.N.-KT 50000/70 at 220/132/33 kV GSS, Ulijhari(CBSA-I)
2026_JSEB_116629_1
378/PR/JUSNL/2026-27
Open Tender
Electrical Works
Works
90 days
Ulijhari (CBSA-I)
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
Yes
₹99,000
Yes
8 Sept 2026
29 Jul 2026
19 Aug 2026
29 Jul 2026
18 Aug 2026
29 Jul 2026
Tender Inviting Authority: General Manager, Transmission Zone-VIII, Chaibasa
e-NIT no.: 378/PR/JUSNL/2026-27
Name of the Bidder/ Bidding Firm / Company :
Name of the work :-Overhauling work of Kanohar make 150 MVA, 220/132 KV AUTO transformer no. 2(S.N.-KT 150000/5) and 132/33 KV 50 MVA Power Transformer no. 2(S.N.-KT 50000/70 including (oil leakage rectification, replacement of gaskets in Main Tank body & OLTC unit & valve replacement of oil & gas circulation pipeline, pre/post installation test and repairing, refilling, testing & interlinking of Transformer Auxillary unit CTR make NIFP system & OLTC) at 220/132/33 KV GSS Ulijhari (Chaibasa-I)
SL. No. Descriptions Unit Qty Rate to be quoted by the bidder Amount
1 Shifting, loading dragging of dismantlled accessories of transformers line radiator, conservator tank, pipe line, fans headers DM box, FCC, oil barrels etc., from place of storage to work spot and vice versa of transformers. for both transformer 2 job required during dismantling & erection. job 4
2 Transportation of GIS equipments / Transformer's accessories/fittings per truck (9 MT capacity) per Km including loading & unloading. (for transportation of 02 Nos. of 20KL tank and nitrogen cylinder transportation upto 200KM)(Jamshedpur to Ulijhari)(Distance of one trip=60Km, hence for two trip 120Km) Km 120
3 Hiring Charges of 2 Nos. of 20 KL Tanker for storage of Transformer oil during Dismantaling, erection, inspection, inner cleaning, washing of core, winding, body, oil filteration & Nitrogen purging process. 10 daysx2tank=20 days for 150 MVA and one no. of 20KL for 50MVA for 10 days days 20
4 Supply and installation of Pressure relief device suitable for 150 MVA, 220/132 KV Kanohar make power transmformer and one 50MVA nos. 3
5 Transformer Bushing/CT Connector for Double Moose conductor with bronze/copper mounting (As per site requirement) nos. 12
6 16/32 Amp Power contactor of type AC-I duty-1, 3 Pole IS/IEC/60947-4-I (along with thermal OLR/ ON, OFF delay timer, Auxillary Contact as per requirement) nos. 45
7(i) G.M. Full Way Valve (ISI Marked) for Radiator Unit 80 mm brass stop cock wt. not less than 2.5 kg. without wheel nos. 15
7(ii) G.M. Non Returning Valve Horizontal (ISI Marked) for N2 (Nitrogen) injection peripheral Unit 20 mm brass stop cock wt. not less than 250 gms. nos. 16
7(iii) G.M. Non Returning Valve Horizontal (ISI Marked) for Main Oil Circulation Pipe Line 100 mm dia wt. not less than 1.80 Kg. nos. 6
7(iv) G.M. Non Returning Valve Vertical (ISI Marked) for Main Oil Circulation Pipe Line 100 mm dia wt. not less than 1.80 Kg. nos. 6
8 Oil drain and refilling in trafo kl 126.26
9 Filling of dry nitrogen gas in transformers (20 Cylinders for each transformer) Capacity per cylinder 52 Kg nos. 40
10 Rate of replacement of gasket along with supply of Gasket of
a Radiator nos. 20
b HV Bushing nos. 6
c LV Bushing nos. 6
d HV/LV Neutral Bushing nos. 2
e Conservator Tank nos. 2
f Oil Level Gauge nos. 2
g Silica Gel Pot nos. 2
h Replacement of gasket of door of marsheling box & OLTC Control Cable nos. 2
i Inception cover, Main, Hole Cover, Valves, Connecting Pipes, Tightening & Terminal arrangement of buchholz relay, OTI, WTI. nos. 2
11 Dismentalling, Erection, all necessary testing (Type test (pre & post overhauling) charges including service tax etc. to be conducted on only one transformer. a) IR/DI/PI Pre & Post work both b) BDV/DGA/Furan/ pre-filteration/ post filteration both. c) All Electrical Test e.g. short circuit, open circuit, magnetic balance, stability, WRM, TAN delta test etc as applicable. Any othe test as required on-site job as per direction of E/I, including testing of transformer Main and back up relay testing) and final charging of 150 MVA, 220/132 KV Auto Transformer, including radiators inspection chamber pocket, OLTC chamber, all conservator tank, air seal, HV & LV Bushing, MOG, Breather, Cooling Fan, transformer protection relay & Valves, Local Control Panel, all complete job with supply of all T&P items viz. dryer plant, evacuation plant, oil filteration plant crane etc. and cost against necessary consultation charges payable to Kanohar, inner cleaning, washing of core, winding body etc. complete job as per direction of Engineering In Charge. Lot 1
12 Dismentalling, Erection, all necessary testing (Type test (pre & post overhauling) charges including service tax etc. to be conducted on only one transformer. a) IR/DI/PI Pre & Post work both b) BDV/DGA/Furan/ pre-filteration/ post filteration both. c) All Electrical Test e.g. short circuit, open circuit, magnetic balance, stability, WRM, TAN delta test etc as applicable. Any othe test as required on-site job as per direction of E/I, including testing of transformer Main and back up relay testing) and final charging of 50 MVA, 132/33 KV Power Transformer, including radiators inspection chamber pocket, OLTC chamber, all conservator tank, air seal, HV & LV Bushing, MOG, Breather, Cooling Fan, transformer protection relay & Valves, Local Control Panel, all complete job with supply of all T&P items viz. dryer plant, evacuation plant, oil filteration plant crane etc. and cost against necessary consultation charges payable to Kanohar, inner cleaning, washing of core, winding body etc. complete job as per direction of Engineering In Charge. Lot 1
13 Filteration of transformer oil machine supplied by the firm Ltr 63130
14 Painting of Transformer body and accessories
(a) Labour charge for cleaning, brushing & scraping old paint as per direction of E/I. M² 1907.76
(b) Providing primer one coat red oxide paint in main tank and other parts. M² 1907.76
(c ) Spray painting two coats with enarmel paint of main tank and other parts. M² 1907.76
15 Constructions of chemical earthing with GI chemical electrode and suitable earth enhancing compound for both transformer. The chemical earthing shall be non-corrosive highly galvanised pipe with 3 meter length. The electrode shall be filled with higly conductive & non corrosive mixture so that inner strip and pipe should never corrode and provide lowest possible resistance. The minimum diameter of outer pipe shall be 40mm. The quantity of earth enhancing compound required per earth electrode shall be 50Kg for each electrode. Nos. 5
16 Welding Charges mm 20000
17 Refilling of Fire Extinguisher for Nitrogen Injection Fire Protection System 10 cum nitrogen at 150 kg/sq cm pressure, max. weight 460 kg (Fire Extinguisher Medium Nitrogen Gas.) kg 460
18 Engineer Service Charge for consulatation with i.e. OEM CTR Manufacturing Industries Pvt. Ltd. for NIFPS 1 service Engineer upto 7 days Mandays 7
Labour cess @1%
Total Quoted value
Note:-Only blue colour cell to be filled by the agency.
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
378TenderDoc.pdf
Tender Documents • 0.58 MB
378PricePart.xls
Additional Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .