Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance BHU | Admitted-Finance |
| 2 | Admitted-Finance NAGAR ATHANI P O MULAMGUNNATHUKAVU THRISSUR 680581 | THRISSUR | THRISSUR | KERALA | 680581 | Admitted-Finance |
Tender Value
₹18.7 L
EMD Value
₹46,825
Closing Date
20 Dec 2024, 4:00 pmClosed
DGM (Projects)
DGM ( ROJECT ) Travancore Titaniumproducts kochuveli Thiruvananthapuram
Construction of Cooling Tower Basin, Pump Foundation 2nos For Vacuum Evaporation Plant.
2024_TTPL_711440_1
PROJ/Civil works/KV28/VES -CoolingTower/24-25
Open Tender
Civil Works - Others
Item Rate
90 days
Travancore Titanium Products Ltd, Trivandrum- 21
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,950
Yes
₹46,825
Yes
Travancore Titanium Products Ltd, Trivandrum- 21
4 Jan 2025
3 Dec 2024
23 Dec 2024
3 Dec 2024
20 Dec 2024
3 Dec 2024
3 Dec 2024 - 20 Dec 2024
9 Dec 2024
Construction of VES Cooling Tower Basin and Pump Foundation
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Clearing of Site, removal of debris and cutting of shrubs and dumping the waste materials to dump yard etc, complete as per the direction of Engineer in charge.
Centering and shuttering including strutting, etc. and removal of form for: Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, etc. and removal of form for: Lintels, beams, plinth beams, girders bressumers and cantilevers
Centering and shuttering including strutting, etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. All work above plinth level upto floor V level
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete. Sufficient solid block will be supplied from TTPL.
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
Providing and applying integral crystalline slurry of hydrophilic in nature for water proofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .