Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance CHARUVILA PUTHEN VEEDU KOTTUKAL NELLIMOODU P O TRIVANDRUM 695524 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695524 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance NALLOOR H NALUKODY P O CHANGANCHERRY | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹3.4 L
EMD Value
₹8,592
Closing Date
5 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
LSGD Section LID EW Pathanamthitta Municipality
330/24,Renovation of Municipal Office (Electrical Work)
2023_LSGD_590883_1
2023/PTAMUN/E/330/2023-24
Open Tender
Electrical Works
Item Rate
30 days
PATAHANAMTHITTA
Please refer Tender documents.
8 documents required · 8 mandatory
₹760
Yes
₹8,592
Yes
7 Aug 2023
29 Jul 2023
7 Aug 2023
29 Jul 2023
5 Aug 2023
29 Jul 2023
Amount
ELECTRIFICATION
OD54694/2023-2024:Supply and fixing wipro led strip light output 10 w /mtr 3000k with IP65 protected (WIPRO LS39-010-120-30-50 ) and giving connections required.
OD54698/2023-2024:Supply and fixing wipro led strip light drive 60 W (meanwell LPV-60-24LED DRV pot60 w) and giving connections required.
90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD47947/2023-2024:Supply Conveyance, installation, testing and commissioning of havells make 190 w(ENPEARLMAGPLUSSL 190 WLED757PASYTOTGHEENT) LED street light output greater than 150lumen/W 5700 K with IP 66 protection power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance
OD54605/2023-2024:Supply Conveyance, installation, testing and commissioning of HAVELLS MAKE 50 W Flood light (JETAQUANTOPLUSFLS50WLEDREDP30DPC)output 140lumen/W red color IP 66 protection with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance
OD54652/2023-2024:Supply Conveyance, installation, testing and commissioning of HAVELLS MAKE 30 W Flood light (JETAQUANTOPLUSFLS30W757SYMLENS)output 140lumen/W 3000 K, IP 66 protection with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
90.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp
OD47949/2023-2024:Supply and fixing Sintex junction box GSJB 1616T top hinged door of size 14OX140X100mm with provision for fixing SP/DP MCB for terminating cable.
OD47950/2023-2024:Supply and providing 32 A HRC fuse base with HRC fuse link.
OD47951/2023-2024:Supply and providing 32 A 2 way neutral link on existing meter box
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
OD47953/2023-2024:25x6mm brass bolt with hexagonal/square head, nut and washer
A ONE AGENCIES
THAHA H
Bidder Name
A ONE AGENCIES
Xavier Joseph
THAHA H
stage.html
html • 0.02 MB
finance_874454.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .