| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L3₹87.2 L+₹7.3 L (9.20%)Accepted-Finance | ₹87.2 L+₹7.3 L (9.20%) | L3 | Accepted-Finance Consistent (Responsive) |
| 2 | L1₹79.8 LRejected-Finance | ₹79.8 L | L1 | Rejected-Finance Transgresses ITB in the SBD a sl no 25 36 |
| 3 | L2₹87.2 L+₹7.3 L (9.20%)Rejected-Finance | ₹87.2 L+₹7.3 L (9.20%) | L2 | Rejected-Finance Consistent |
| 4 | L2₹87.2 L+₹7.3 L (9.20%)Rejected-Finance | ₹87.2 L+₹7.3 L (9.20%) | L2 | Rejected-Finance Consistent |
| 5 | L4₹87.4 L+₹7.5 L (9.42%)Rejected-Finance | ₹87.4 L+₹7.5 L (9.42%) | L4 | Rejected-Finance Withdrawal from tender Participant |
Tender Value
₹91.8 L
EMD Value
₹91,770
Closing Date
1 Feb 2024, 12:00 pmClosed
Executive Engineer
office of the Executive Engineer Engineering Wing Department of Education Itanagar
C/o Class Rooms at Govt. ME School, Namsing in East Siang District, Arunachal Pradesh.
2024_ARED_1590_1
EDN(EW)/Plg-015/2021/120
Open Tender
Civil Works
Item Rate
360 days
namsing mebo
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,000
Payable To Executive Engineer
₹91,770
Itanagar
29 Feb 2024
22 Jan 2024
1 Feb 2024
22 Jan 2024
1 Feb 2024
22 Jan 2024
29 Jan 2024
Amount
( SH: School Building )
Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavated soil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m.
Re-filling excavated earth in foundations and plinth etc. in 15 cm layer including ramming and watering etc. complete.
Filling in plinth with sand under floors including watering, ramming, consolidating and dressing complete.
Random rubble masonry with hard stone in foundations and plinth in cement mortar 1 : 6 (1 cement : 6 fine sand) including levelling up with cement concrete 1 : 6 : 12 (1 cement : 6 coarse sand : 12 stone aggregate 20 mm nominal size) at plinth level.
Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. a) Foundations and plinth
Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in : a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforcement cement concrete work in columns, pillars, piers, abutments, post and struts etc up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but exluding cost of centring, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete work in lintels, beams and bresumers up to floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement. a) M20 (1 cement : 1.5 coarse sand : 3 stone aggregate 20 mm nominal size).
Reinforced cement concrete in suspended floors, roofs, landings and balconies upto floor two level including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
Reinforced cement concrete work in stair cases except spiral cases including finishing and plastering the exposed surface with cement mortar 1 : 3 (1 cement : 3 fine sand) of thickness not exceeding 6 mm to give a smooth and even surface but excluding cost of centering, shuttering and reinforcement.
Centring and shuttering including strutting, propping etc and removal of form work for : a) Foundation, footings, bases of columns etc. and mass concrete.
b) Column, pillars, posts and struts etc.
c) Lintels, beams, girders, bressumers and cantilevers etc.
d) Suspended floors, roofs, landings shelves and their supports, balconies and chajjas (3.5 m height).
e) Stairs (excluding landings) except spiral stair cases.
Reinforcement of RCC work including bending, binding and placing in position complete. a) Tar/ TMT steel
Brick work with best available local bricks in foundations and plinth in cement mortar 1:4 (1 cement : 4 fine sand).
Extra for brick work with best available local bricks in superstructure above plinth level up to floor two level.
Providing approved best available local wood (Class - B II) work in frames of doors, windows clerestory windows and other frames, wrought framed and fixed in position.
Providing and fixing 44 mm thick best available local wood Class - B I (19 mm batten and 25 mm bracing) battened and braced doors and windows shutters including providing and fixing necessary bright finished or black enamelled T-hinges, butt hinges, sliding door bolts, tower bolts and handles with necessary bolts and nuts and screws complete.
Providing and fixing panelled, glazed or panelled and glazed shutters for doors, windows and clerestory windows including necessary iron butt hinges with necessary screws. a) 38mm thick best available local wood class - B I
Providing and fixing 38 mm thick wire gauge shutters using galvanized mild steel wire gauge of IS gauge designation 140G with wire of dia 0.56 mm for doors, windows and clerestory windows including anodized aluminum butt hinges with necessary screws. a) Best available local wood class B-I
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws. a) Ornamental grill.
Providing and fixing aluminum sliding door bolts anodised transparent or dyed to required color or shade with nuts and screws etc complete. a) 300 x 16 mm
Providing and fixing aluminum Tower bolts anodized or transparent or dyed to required color or shade with necessary screws etc complete. a) 300 x 10 mm
Providing and fixing aluminum Handles anodised transparent or dyed to required color or shade with necessary screws etc complete. a) 125 mm for Door
b) 100 mm for Windows
Providing and fixing MS safety hasp and staple with necessary screws etc complete. a) 150 mm
Providing and fixing 40 x 3 mm flat iron hold fasts 40 cm long including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedding in cement concrete block 30 x 10 x 15 cm in 1 : 3 : 6 (1 cement : 3 sand : 6 hard stone chips 40 mm nominal size).
Providing and fixing MS fan clamp type I of 16 mm dia MS bar bent to shape with hooked ends in RCC slabs during lying including painting the exposed portion of loop all as per standard design complete.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. a) M.S. tube
25 mm thick cement concrete flooring 1 : 2 : 4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) finished with a floating coat of neat cement.
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
15 mm cement plaster 1 : 3 (1 cement : 3 fine sand) on the rough side of single or half brick wall.
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paits/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the halp of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
Finishing walls with water proofing cement paint of approved brand and manufacture and required shade on new work (three or more coats) to give an even shade.
Applying priming coat with ready mixed pink primer of approved brand and manufacture on wood work complete.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of approved brand and manufacture in all shades on new work to give an even shade.
Applying priming coat with ready mixed genuine red lead paint of approved brand and manufacture on steel work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade.
Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finsihing the top smooth.
Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/Aggrigate 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete.
Excavation in Hilly Areas in Soil by Manual Means (Excavation in soil in Hilly Area by Manual Means including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per drawing and Technical Specification.
Excavation in Hilly Area in Ordinary Rock by Manual Means (Excavation in Ordinary Rock using Manual Means including loading in a truck and carrying of excavated material to embankment site with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.)
Internal Electrification PVC insulated PVC sheated alluminium calbe of size 1.50 sqm ( 91m per coil)
PVC insulated PVC sheated alluminium calbe of size 2.50 sqm ( 91m per coil)
5 AMP F.T. Switch
5 AMP Socket with 5 AMP Switch combined
Brass Bracket Holder
Bulb head fitting
PVC Tape 25m x 4mm
Deto Fix power
T.P. & N main switch 100 AMP
S/F four pole 415 V insulator 32 AMP with existing MCDB / DB complete connection testing etc as required 4 pole 100 AMP.
G.I.pipe 40mm dia
Fan clamp.
Semi Round Clamp
Switch board Mica 200 x 250mm.
Switch board Mica 175 x 100mm
Switch board Mica 100 x 100 mm
Screw 1/2", Screw 1'1", Screw 11/2"
Ceiling rose
4' - 0" 40 W flurocent light fitting with 40W tube light
AC ceiling fan 1400 mm sweep complete with regulator etc. as required
Earthing with GI Pipe 4.5 m long and 40mm dia i/c accessories as required.
Extra for using salt and charco for pipe, earth electrical etc as required
PVC Tee 3/4"
PVC Tee 1"
PVC Junction box 1"
PVC Junction 3/4"
PVC Elbow 1"
PVC Elbow 3/4"
Wiring for light fan point 3 pin 5 AMP / 15 AMP socket out let with 2.50 sqm and 6 sqm copper / Alu. Wire is earthing and connection etc. as required the work is to be carried out by a qualified wire man (Job work only).
Earthing copper plate (size 2"/2 x " x 5mm).
Furnitures for Classroom Wooden Writing Table (Small size)-2'x4'x2'6"
Wooden Chairs (armed)- 1'6"x1'6"x1'5"
Woden Desk- 4'x1'10"x2'6"
Wooden Bench- 4'x9"x2'
M/S N.Y. ENTERPRISES
M/S A.G.R. ENTERPRISES
M/s Yoyo Enterprises
M/s N.K Perme Entrprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .