| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹42.9 L+₹4.6 L (11.9%)Rejected-AOC HQ CE SC PUNE | PUNE | MAHARASHTRA | 410301 | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹43.3 L+₹4.9 L (12.8%)Rejected-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹43.3 L+₹4.9 L (12.9%)Rejected-AOC SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹44.3 L+₹5.9 L (15.4%)Rejected-AOC HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹77,000
Closing Date
3 Jan 2023, 5:00 pmClosed
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
REPAIR, MAINT OF STP, TTP AND CERTAIN EXTERNAL INTERNAL EM REPAIR MAINTENANCE WRK AT VARIOUS LOCATIONS, AT DHQ 1 , PORBANDAR, DHARMPUR, JETTY,CGAE,UNDER GE I CG PORBANDAR
2022_MES_569188_1
8820
Open Tender
Civil Works
Item Rate
180 days
PORBANDAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹77,000
Yes
7 Feb 2023
14 Dec 2022
4 Jan 2023
14 Dec 2022
3 Jan 2023
28 Dec 2022
Amount
SCHEDULE 'A'
Pumping out sewage water from the existing sumps/tanks of STPs (MBBR technology) with the help of Non clogging of pump any kind capacity of pump set not less than 1500 LPM capacity 10HP/15 HP (Minimum) along with taking out mud/ solid sludge from the tank complete from soild sepration chamber, aeration chamber and despose whole sludge to faraway areas from public places including cleaning of sump completely. So as to vacate the sumps to enable the repair of the main non clogging pump sets installed in the STPs, complete all as specified and as directed by Engineer-in-Charge. Note :- (a) Pumping shall be continued till the main pumps installed in STPs sump is cleared for carrying out repair work. (b) Delivery pipe should be connected and the sewage water shall be thrown in the manhole of out side the fencing /wall of STPs towards the main gravity dropping manhole. (c) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative. (d) Necessary man power to operate the pump set are deemed to be included in the unit rate. (e) the unit rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set. (f) the unit rate included for transportation of pump set to site/back.
Supply and replacement of STP Tank chamber cover, gas kit neoprene 550 x 710 x 3 mm thick and replcement of SS-Hex DH Bolt 1/2 x 1/2 with 1N + 2 PW complete all as specified and as directed by Engineer-in-Charge. Note :- 1. Gas Kit - 29 Nos 2. Nut & Bolts as required all as deemed to be included in quoted rate.
M&L in PP floating media to top up for bio reactors, complete all as specified.
Carry out water testing of bacterial, chemical and biological analysis of sewage water treated water from NABL accredited Govt approved lab for following parameters and submission of test reports all as directed. (a) PH (b) Chemical Oxygen demand/COD (c) Biological Oxygen Demant/BOD (d) Total Suspended solids (e) Oil and grease (f) TKN (g) Total Coliform (h) Organism MPN (k) Dissolved Oxygen Note: water testing shall be carried out as per CA Qty in period of contract all as directed without fail else recovery will be made at Rs 15000/- per test for execution of item and for non-submission of Test Report.
Supply only Sodium hypochloride Calcium based, high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed container (45/50 Kg 45 Kg container), chlorine concentration level 40-60% 65-70 % , complete all as specified and as directed. Make Rayalseema, Brand Puri chlor
Supply only Hypochlorous Acid net wt 38 kg, high strength chlorination chemical for water disinfectant in any form granular or in liquid form in factory sealed HDPE container (45/50 Kg 45 Kg container), chlorine concentration level 40-60% 65-70 % and delivered at STP complete all as specified and as directed. Make: Aditya birla or equivalent
Supply only bleaching powder suitable for water disinfection
Dismantling Sewage submersible pumping set of cap 3 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including . electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. (Note : Cost of dismantling and refixing deemed to be included in unit rate)
Dismantling Sewage submersible pumping set of cap 5 HP 3 Phase from site after disconnecting of electric connection and delivery line, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, and rewinding with supper enamelled copper wire as per existing gauge refixing the same at site including . electric and piping connections complete, checking for satisfactory working all as directed by Enginner-in-charge. (Note : Cost of dismantling and refixing deemed to be included in unit rate)
Taking down air blower of Air blowers with working pressure 0.3 Kg/cm2 alongwith motor of capacity 5 HP with blower pipe of size 3", from the existing position after disconnecting all electrical connection and transportation to workshop for repair for un-serviceable parts complete and removing the defective parts, repair the air blower throughly including machine work and re-assembling the air blower and commssioning testing complete on full load all as specified and directed by Engr-in-charge Note-new spares shall be measured and paid separately in respective items)
M&L for taking out & servicing of existing unserviceable Air Blower (of any Make ) of capacity 5.00 HP pressure 0.3 Kg/cm2 with taking out of electric cable complete and reconnecting the electric and mechanical connection at existing location after carrying out following repairs all as specified and directed by Engineer-in- charge. Note- (i) Spare part required for replacement shall be measured and paid separetly under relevent items (ii) Replacement of Oil seal, locking arrangement of pully, gland packing with oil and greasing shall be deemed to be including in the quoted rate of this item.
S & F replacement of "V" Belt (SPA 1250) unserviceable /worm-out 'V' belt of air blower etc, all as directed by Enginner-in-charge. Makes:- Fenner/Dunlop/Nerlon/Super flix/Ecodrive.
M&L in replacement of Gear oil 90 EP, Pressure Gear Oil etc., all as directed
S & F in replacement air-filter for blower suitable size for existing air-filter etc, all as directed by Enginner-in-charge.
Supply only Grease 30K, for using ensure protection of metal surfaces extending bearings, Hinges etc. all as directed.
M&L for finding out defect of STPs panel and taking out burnt interconnection wiring including U/S and serviceable component for re-use including rewiring of panel using existing size of copper cable, ferrule, lugs, insulating materials, nut bolts washer of various sizes refixing serviceable items, complete all specified and as directed.
Supply and fix in replacement of Flexible Flat of size 2.5 Sqmm 3 core, PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade including drawn through HDPE/PVC conduit of size 25 mm dia inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to light etc, including taking down old unsv cable all as directed by Engineer in charge. Make :- Polycab/RR Kable/Havells /Finolex Note: 1. Conduit, saddles & small excavation of cable in gardens deemed to be included in the unit rate.
Supply and fix in replacement of Flexible heavy duty of size 10 Sqmm 3 core PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade including drawn through HDPE/PVC conduit of size 32 mm dia inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking down old unsv cable all as directed by Engineer in charge. Make :- Polycab/RR Kable/Havells//Finolex Note: 1. Conduit & saddles deemed to be included in the quoted unit rate.
S&F in replacement of Round strand Galvanized Iron Steel Wire Rope dia 8 mm and connected clamp nut bolts fixed etc, including taking down old unsv cable all as directed by Engineer in charge.
Servicing of DG set ('C' Check) of Cap 70 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter. (b) Lubrication oil. Make of DG set: Ashok Leyland/Kirlosar Note: Defective parts if any other than listed at 20.01 to 20.08 above will be measured and paid separately.
Supply only following parts/ Items of DG set 70 KVA
Oil Filter
Fuel Filter cum water seperator
Air Filter Safety
Air Filter Primary
Coolant
Engine Oil
Fuel strainer
Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 70 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint as specified and directed at site by Engr-in Charge.
Servicing of DG set ('C' Check) of Cap 20/30 KVA by Rep of authorised service centre as per manufacturer manual and checking of fuel supply system, Lubrication system, cooling system, battery ignition system and rectification of defect if any and including replacement of following, complete all as specified and directed by Engr-in-Charge. (a) Lub oil filter. (b) Lubrication oil. Make of DG set: Ashok Leyland/Kirlosar Note: Defective parts if any other than listed at 21.01 to 21.08 above will be measured and paid separately.
Supply only following parts/ Items of DG set 20/30 KVA
Oil Filter
Fuel Filter cum water seperator
Air Filter Safety
Air Filter Primary
Coolant
Engine Oil
Fuel strainer
Materials and labour for scraping removing and cleaning old rusty paint from enclosure of DG set 20/30 KVA capacity any make by cleaning agents & painting the above DG set complete with Polyurethane (PU) paint as specified and directed at site by Engr-in Charge.
Taking down unserviceable battery charger and supply and fix new automatic electronic battery charger, 10 Amps, 12 Volts including making electric connections and to be housed in AMF panel, complete all as specified and directed. Make:- Maha mai / Span /Vinitech/NHP
S & F in replacement of battery terminal complete all as specified and directed.
Supply and fix in repair power contactor MNX - A1,/MCX-22/MCX-13, 50 Hz, complete all as specified and directed. Make : L&T or equvalent
Supply and fix in repair power Relay MNX - A2,/MCX-22, 50 Hz, complete all as specified and directed. Make : L&T or equvalent
Supply and fix in repair digital type Frequency meter, complete all as specified and directed. Make :-L&T/ AE/IMP
Supply and fix in repair digital type volt meter, complete all as specified and directed. Make :-L&T/ AE/IMP
Supply and fix in repair digital Ampere meter with CTs, complete all as specified and directed. Make :-L&T/ AE/IMP
Spray Painting of Pump & Motor any type, any capacity upto 25 HP as per colour code (Shade) of MES specification after cleaning the dust particle of existing motor & Pump as directed by Engr-in-Charge.
M&L for Cleaning of semi under ground RCC sump of capacity 1,00000 gallons throughly removing mud, grits etc. from the sump by following method: - (a) Removing all dirt, mud with the help of containers mannually from inside to the water storage Sump, then scraping to walls/pillars/floor complete as directed. (b) Washing with clean water after scraping with wire brush in side and removing mud and spoil to a distance n.exc. 50 mtrs. (c) Washing with clean water and bleaching powder including scraping wire brush on walls/pillars and floor & removing mud and grits & deposits etc properly. (d) Repair/Replacement to all inlet/out lets of sump with a reqd size of MS/GI Pipe as directed including cement work etc complete leakage proof. (e) Dry washed walls, coating with a one coat of white cement inside the whole surface of walls/pillars and floor of sump. Note: 1. Consumption of bleaching powder for cleaning of tank shall not be less than 60 Kgs, deemed to be included in unit rate. 2. Minor repair/ replacement of inlet & outlets of any tpye / size of pipes, fixed in original position deemed to be included in unit rate.
Collecting the sample of water at Pump house and testing of water for iron, PH value, TDS, colour, Total Hardness, chloride, Chlorine, fluoride, Coliform, arsinic test and submitting the test report from reputed laboratory as directed by Engineer-in-Charge.
Dismantling and opening the Chemical dosing pump from the existing position for servicing from authorised compeny and refixing the same in original position and testing and commissioning the pump all as directed and specified by Engr-in-charge.
Supply, install, comissioning and testing replacement of Automatic Intelligent power factor correction (APFC) panel 3 Phase 415 Volt 50 HZ supply system to improve the power factor from 0.8 to 0.99/unity automatically with step wise switching facility with floor mounted indoor type weather proof dust/vermin proof Powder Coated Cubical panel made out of 2 mm CRCA sheet and angle iton 40mmX40mmX6mm frame. Factory made fabricated as modular in dualy powder coated, front openable with locking arrangements of capacity 100 KVAR (15 KVAR - 3 Nos, 10 X 4 Nos, 5 X 3 Nos) Capacity with the following acessories. Make: CPRI approved, Channel partner of L&T/Schinder/Legrand/C&S Location: OTM Complex
Maintenance/ Repairs of RO Plant Cap 150LPH installed at OTM Complex including cleaning and replacement of sedimatation filter and carbon block, Membrane Element, Antiscalent chemical and Miscellenous Items etc., including taking down old unsv materials complete all as spd and directed.
Material and labour for maintenance of solar water heating system flat plate type incl all water and electric connections of capcity 100 Ltrs per day and refixing the same in existing position after the following repairs and testing complete :- Location : CGRA Dharampur, Inaz Vig. (a) Replacement of the worn out/missing nuts bolts, washers, unions, sockets flanges and screw etc complete. (b) Descaling/desludging the hot water pipes and normal water by using appropriate chemicals/Anti corrosive/Anti scaling agent solution, cleaning and washing all copper tube & water circulated pipes of heat convetor sets throughly cleaning the complete solor pannel of making the tube scale free and reassemling the pannel. (c) Cleaning hot and cold water tanks, removing sludge and scale from the tank manually using suitable chemicals complete. (d) Repair of collector fins incl required welding works etc complete. (e) Testing on completion after Repair work and making the Solar Water Heater functional in each aspects. (Note : Cost of dismantling and refixing and minor repairs deemed to be included in quoted rate.
All as per item No. 37 here in before but of capacity 200 ltrs per day complete all as directed by Engineer -in -charge. Location : CGRA Dharampur, Inaz Vig.
All as per item No. 37 here in before but of capacity 300 ltrs per day complete all as directed by Engineer -in -charge. Location : CGRA Dharampur, Inaz Vig.
Material and Labour for painting the MS supporting structure of solar water heating system complete as per original shade with two coats of synthetic enamel paint over one coat of primer by spray gun after scrapping the existing paint, denting, filling depression with putty etc complete all as specified and directed. Location : CGRA Dharampur, Inaz Vig.
Supply and fixing in replacement of PVC Suction hose pipe at STP, working pressure 10 Kg/Sqcm of size 50/63 mm bore complete all as directed.
Supply and fixing in replacement of PVC foot valve assembly complete of suitable size for pipe of size 50/63 mm bore all as directed.
Supply and fixing in replacement of Butterfly valves lever operated body grey cast iron of size 65mm bore, with all fittings confirming to IS specification all as specified.
Supply and fixing in replacement of Butterfly valves lever operated body grey cast iron of size 50 mm bore, with all fittings confirming to IS specification all as specified.
Supply and fixing in replacement of non return valves (NRV) body grey cast iron of size 50/63 mm bore, with all fittings confirming to IS specification all as specified.
M&L for laying in replacement of High density polyethylene(HDPE) pipes of pressure rating 6 kgf/sq. cm of size 50 mm dia laid in treanches including taking down the old u/s pipe all as specified and as directed
Supply and laying in replacement of CPVC pipes of size 50 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good all as specified and directed by Engineer-in-charge. Make: Supreme/Astral/Finolex
Supply and laying in replacement of CPVC pipes of size 32 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good all as specified and directed by Engineer-in-charge. Make: Supreme/Astral/Finolex
Supply and laying in replacement of CPVC pipes of size 25 mm dia (outer dia) SDR-11 including plain CPVC SDR including all fittings such as bends elbows, tees, short pieces, connectors, check nuts, diminishing pieces, caps and plugs, unions, etc fixed complete laid in trenches / along the walls / ceilings / floors / ducts / on pillar post and including making good all as specified and directed by Engineer-in-charge. Make: Supreme/Astral/Finolex
S & F in replacement of Ball Valve of 50 mm Dia Long Handle of size Supply and laying in replacement and connected at both ends for CPVC pipes or ferrule and fixing including necessary fittings like unions, check nuts, etc. and including any addition / alteration any required for fixing and making good all as specified and directed by Engineer-in-charge. Make: Supreme/Astral/Finolex
All as per above Item, but size 32 mm dia, all as specified and directed by Engineer-in-charge. Make: Supreme/Astral/Finolex
All as per above Item, but size 25 mm dia, all as specified and directed by Engineer-in-charge. Make: Supreme/Astral/Finolex
S&F in replacement of Automated Landscape Irrigation System, System consists of Pop up Sprinkler of 2.5 to 3 Mtr Radius water sprayer Irrigation System, 0 - 360 Degree part-Circle with complete accessories, Controls with automation components, including making good complete all as specified and as directed. Make: Rain-Bird (Spray Popup) or equivalent
S & F in replacement of disc filter of Size 50 mm dia and connected to two ends externally for CPVC pipe or for unions and fixed complete and including filter chamber of size 300 X 300 X 300 mm including necessary earth work in any type of soil, necessary excavation earth work all plastered surfaces of filter chambers and making good all as specified and directed by Engineer-in-charge. Make: Rain-Bird or equivalent
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Hard/ dense soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material not exc to distance 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply & fix in Replacement of Bldg Security light fitting LED type 25 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and including driver unit etc and taking down old unsv any size/watt of security light all as directed by Engineer in charge all conforming to Make:Wipro or equivalent from Bajaj/Philips
S&F in Replacement of LED flood lights 50W, aluminium die cast housing with purity lense for facade lightning with glare free light distrubition enhancing accent lighting, including fixing arrangements etc complete all as specified and directed. Make : Wipro cat No. D915065-1 or its equivalent in Philips/Bajaj
S&F in Replacement of LED Bollard light cool light white 4000K of Wattage 17 Watts, IP 65 Protection with integrated mounting base plate and driver complete housing dark grey RAL 7043, Die cast, Polycarbonate diffuser, Operating Voltage 140-270V AC 50 Hz including PCC 1:2:4 type B1 (20 mm graded aggregate) suitable size for mounting of light fitting including mounting pole with accessories not less than 1.2 Mtr height for fixing with anti-rusted nut & bolts etc required as per site all as spd and directed. Make : Philips Cat No BCP400 LED09 D CW PSU GR S1(City Cube Bollard D)/ Wipro/Bajaj or its equivalent Note: Apply for single coat of suitable colour distempering for bollard foundation shall deemed to be included in the quoted rate.
S&F in Replacement of LED Bollard 10W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, pole mounted, including PCC 1:2:4 type, base of size 300mm x 300mm and depth 500 mm for fixing of Bollard with nuts bolts etc required as per site all as spd and directed. Make : Crompton Cat No LBLSN-10-CDL or its equivalent in Bajaj/Wipro/Philips
S&F in Replacement of LED 7W (3 Head), up & down light (3000K), coated aluminium pressure Die-Cas,t housed in safe and with high illumination out door wall light LED, including fixing arrangements etc complete all as specified and directed. Make : Philips Model No 58161 or its equivalent inWirpo /Bajaj/Prisha
S&F in Replacement of Fancy Wall mounted LED Lamp, suitable for E 27, including LED Lamp 7 Watts E 27, including fixing arrangements etc complete all as specified and directed. Make : Philips or its equivalent inWirpo /Bajaj/Prisha
S&F in Replacement of RGB LED 9W, IP 68, Aluminium die cast housing with purity lense for spot lightning with glare free light distrubition enhancing accent lighting, including fixing arrangements, S Connector & T Connectors etc complete all as specified and directed.
S&F in Replacement of Controller, Plug-socket S connector, 3-Channel Main Controller, input/output, accesories complete all as specified and directed.
S&F in Replacement of SMPS Driver and accesories etc complete all as specified and directed.
S&F in Replacement of automatic street light switch (5 KW to 8 KW) Amps rating 20 Amps NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compound conforming to IP-54. The contactor, MCB and circuit wiring 16/10 sqmm copper shall be suitable complete all as specified and directed by Engineer-in-Charge. Make :- Model No. SWADEEP-02EC-5KW, 3P (3 PHASE) of Healer or equivalent to Havells /L&T
S&F in Replacement of On-Load Changeover Switch with encloser 100 Amps, 4 Pole, 415 Volt with cable entry, connecting the cables with proper lugs and glands complete all as specified and directed of following:- Make: Indo Asian/Standard/Havells
M&L in replacement of Multi standed Copper Conductor cable of 1.5 Sq mm 4 Core size, drawn through HDPE/PVC conduit of size 25 mm dia inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box/bollards to light etc. all as specified directed. Make :- Polycab/RR Kable/Havells
M&L in replacement of Multi standred Copper Conductor cable of 2.5 Sq mm 4 Core size, drawn through HDPE/PVC conduit of size 25 mm dia inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box/bollards to light etc. all as specified directed. Make :- Polycab/RR Kable/Havells
S&F in replacement of Pole box with 6 Amps MCB provision and suitable connector for single hose connections loop in and out 10 to 16 Sqmm 4 core aluminium armoured cable branch out 1.5 Sqmm single core copper PVC insulated cable enclosed in a thermoplastic polycarbonate enclosure which should be shock proof safe IP 66/67 weather proof, rust proof, dust proof, water proof, internally embedded gasket with provision for cable entry through IP 66/67 thermoplastic metric size glands and/or grommets enclosure size (155 x 210 x 92mm ), fixing arrangement and clamps including making connections all as specified and directed. (Cat Part No KF 1616 G of Make : Hensel or equivalent model of Sintex)
Taking out UNSV LT UG cables of any sizes from trenches all as spd.
Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area as mentioned under complete all as specified and directed by Engr-in-Charge. Make: Polycab/ Havells/RR Kabel
16 Sqmm 4 Core
25 Sqmm 4 Core
Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables of following sizes, complete with coupler and connected accessories all as specified and directed by Engr-in-Charge. Make: Rex/Poly/Geminie Note: Cutting of floor/ road and making good with PCC deemed to be included in item rate.
(a) 50/38 mm for following size
Supply and fix in replacement MCB/MCCB FP, 415 V fixed type, including taking down of old unsv panel after disconnecting Existing cables and reconnecting the cabes with proper lugs and glands complete all as specified and directed of following:- Make: Havells/ L&T / ABB /Schneider
MCCB 63/100 Amp FP, 415 V breaking capacity 27 KA
MCCB 200 Amp FP, 415 V breaking capacity 25 KA
MCCB 250 Amp FP, 415 V breaking capacity 36 KA
MCB 6 TO 32 Amps SP, 240 V breaking capacity 10 KA
Supply only Swimming Pool Alum Powder of Approved Make
Supply only TCCA of approved Make
Supply only Swimming Pool Aigiecide in 05 Liters Can of approved Make
Supply & installation/ in replacement of out door Sign board box type with the following specifications and all as directed by Engr-in-Charge. (a) Size of the board should be 750 mm length, 600 mm width and 200 mm depth (b) 3 mm thick acrylic sheet of 750 mm length, 600 mm width should be provided for screen with adequate picture/letters on both side. (c) Main frame work will be done by 40x20x2 mm SS 316 angle in cuboid in shape. (d) The side of main frame should be covered with 3 mm thick acrylic sheet white in colour. (e) Foundation of structure should be 600 mm length and 800 mm height in PCC / Block Masonary with plaster finish with sutable ceramic tiles 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified. (f) 02 Nos High efficiency white colour LED light mount on 4 mm thick PVC sheet will be provided in each box including 15 mtr multi standard Copper conductor cable of 1.5 Sq mm 3 core size and internal wiring complete with HDPE/PVC conduit of size 25 mm dia. Including taking down old unsv board. Note: 1. Conduit wall saddles & small excavation of cable deemed to be included in the quoted rate
K B N TRADERS
RAJ ENTERPRISE
vijay infraprojects pvt ltd
roxy enterprise
M/s SK Traders
V D JADEJA
AADESH CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .