EKLAVYA MODEL RESIDENTIAL SCHOOL,VEJALPUR
Installation of Fire Hydrant System, Fire Alarm System Work at Hostel Building of EMRS Vejalpur
272552
Online E-Tender OF 2025-26
Open
Fire and Safety Services
Works
Panchmahal
3 documents required · 3 mandatory
₹1,500
Yes
EMRS Vejalpur
₹60,000
Yes
5 Feb 2026
5 Feb 2026
5 Feb 2026
20 Feb 2026
5 Feb 2026
I) FIRE PUMPS & ACCESSORIES, YARD HYDRANT, INTERNAL HYDRANT, HOSE REEL & SPRINKLER SYSTEM Supply, Installation, Testing and Commissioning of Electric driven Fire pump suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, back pullout pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 900 lpm at 55 m. head conforming to IS standards. b) Squirrel cage induction motor with suitable HP with synchronous speed 3000 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards c) Common Base plat for Pump and motor and coupling, coupling guard and other accessories as required for complete installation of pump set. d) Suitable cement concrete foundation with cement concrete plaster complete with anti-vibration arrangement.
Supply, Installation, Testing and Commissioning of 150 mm dia Pressure Gauge of range 0 - 15 Kg / cm² conforming to IS - 3624 having bourdon tube of stainless steel 310 in cast aluminium, stove enameled, black, weather proof case with outer, screwed aluminium bezel and complete with necessary U-type stainless steel siphon tube and cock including providing suitably painted angle iron support to the tube etc.as per specification complete as required.
Supply, Installation, Testing and Commissioning of Pressure Switches for automation of fire pumps. Pressure switches shall be double pole single throw type suitable for single phase supply with diaphragm. Aluminum Enclosure with IP 66 protection as required.
Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, M S Pipes Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. A) 100 mm dia
Supply, installation, testing and commissioning of C.I. Butterfly valve (PN 1.6) with flanges, nut bolts, gaskets complete as required. a) 100 mm dia
Supply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 1.6) a) 100 mm dia.
Supply, installation, testing and commissioning S.S. Single Headed Fire Hydrant Valve with 80 mm N.B. flanged inlet, 63 mm dia female instantaneous outlet type. S.S. coupling, blank cap, chain, twist release type lug & all accessories Conforming to IS:5290. Including fixing with supports, flanged tapping from wet riser, orifice plate complete as required by the Local Fire Authority.
Supply, Installation, Testing and Commissioning of Weather proof Standard M. S. Fire Hose Cabinet wall mounting type (450 mm x 350 mm x 250 mm deep) having single or double opening with necessary locking arrangement by allan key suitable for housing 1 nos. hose pipe, 1no. Branch pipe.
Supply, installation, testing and commissioning non-percolating rubber reinforced lined fire Hose pipe (as per IS : 636) of 63 mm dia and 15 mtrs long. The hose shall be rated for burst pressure of 35.7 Kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound & riveted to hose pipe with copper rivets &1.5 mm copper wire.
Supply, Installation, Testing and commissioning of 63 mm dia instantaneous pattern SS short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required by the Local Fire Authority.
Supply, installation, testing and commissioning of First Aid Hose Reel equipment conforming to IS:884 comprising of hose reel drum, 8 mm shut off nozzle, Rubber hose reel tubing as per IS: 444 of 25 mm dia x 40 mtr. long, painting, Manual fix type with fixing bracket, anchor fastener, bolts & nuts etc. complete as required by Local Fire Authority
Supply, installation, testing and commissioning of SS Ball Valve. a) 25mm dia
Supply, installation, testing and commissioning of Cast lron Two Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc. complete as required.
Supply of Fire Alarm System with hooter,mcp & on/off switch with wiring. (A) MCP
HOOTER
ON/OFF SWITCH
FIRE ALARM PANEL 2 ZONE
2C X 1.5 SQ MM FLEXIBLE CABLE FOR HOOTER & MCP
3C X 2.5 SQ MM FLEXIBLE CABLE FOR ON/OFF SWITCH
Core cuting Charges
Civil Work
water tank 5000 ltr
cable for pump supply 4 sq mm 4 core
Fire Extinguisher Moduler 5 KG Type
2nd and 3rd year Annual maintenance service contract (non comprihenshiv)
NOC GOVERNMENT LEGAL FEES III) Getting Approval FSPA & FSCA/NOC of Fire protection system (Hydrant, Sprinkler etc.) from local fire authority and any other relevant statutory authority at initial and various other stages of work, including preparation of report/drawings as per fire authority.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tender for Fire.pdf
SCHEDULE-B.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .