| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC | ₹23.2 L Quoted ₹24.6 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹26.7 L+₹2.1 L (8.70%)Rejected-AOC | ₹26.7 L+₹2.1 L (8.70%) | L2 | Rejected-AOC OTHER THAN L1 |
| 3 | L3₹29.5 L+₹4.9 L (20.1%)Rejected-AOC VPO BAILLY TEHSIL DALHOUSIE DISTT CHAMBA HP PIN 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | ₹29.5 L+₹4.9 L (20.1%) | L3 | Rejected-AOC OTHER THAN L1 |
| 4 | L4₹30.5 L+₹5.9 L (24.1%)Rejected-AOC | ₹30.5 L+₹5.9 L (24.1%) | L4 | Rejected-AOC OTHER THAN L1 |
| 5 | L5₹30.9 L+₹6.3 L (25.8%)Rejected-AOC 68 BANK COLONY SUNDER NAGAR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹30.9 L+₹6.3 L (25.8%) | L5 | Rejected-AOC OTHER THAN L1 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
14 Nov 2022, 6:00 pmClosed
CWE YOL
HQ CWE YOL CANTT
SPECIAL REPAIR TO BUILDING NO BK-87 AT BAKLOH UNDER AGE(I) DALHOUSIE
2022_MES_557522_1
CWE/Y-61/2022-23
Open Tender
Civil Works
Item Rate
180 days
DALHOUSIE
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) DALHOUSIE
₹68,000
Yes
5 Jan 2023
13 Oct 2022
16 Nov 2022
13 Oct 2022
14 Nov 2022
31 Oct 2022
Amount
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of brick work or stonework built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings ,dressed stonework and precast concrete articles and stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed.
Demolition of textile coverings including frames (if any) and cover fillets (measured flat and not girthed) complete all as specified and directed.
Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed.
Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed
Dismantling timber in scantling 40 sqcm and over in section framed work complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed.
Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed.
PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed.
RCC 1:2:4 (nominal mix) type B-1 (using 20 mm graded crushed stone aggregates ) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
RCC 1:2:4 (nominal mix) type B-1 (using 20 mm graded crushed stone aggregates ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete and like complete all as specified and directed.
RCC 1:2:4 (nominal mix) type B-1 (using 20 mm graded crushed stone aggregates ) as in beams, cantilevers, bressummers, lintels over 1.5m span and like complete all as specified and directed.
RCC 1:2:4 (nominal mix) type B-1 (using 20 mm graded crushed stone aggregates ) as in columns, pillars, piers, posts and struts and like complete all as specified and directed.
Use & waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface of flat concrete complete all as specified and directed.
Use & waste of form work to suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished surfaces of flat concrete, complete all as specified & directed.
Use & waste of form work to sides of square, circular rectangular or polygonal pillars, posts, struts, piers, columns, beams and stanchions for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide for rough finished surfaces of concrete, complete all as specified & directed.
Brick work with old size fly ash bricks, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 all as specified & directed.
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
10mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required and including solar control film 50micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
2nd class hardwood, clean sawn timber framed and fixed as in scantling complete all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Prepainted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed.
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed.
Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight not exceeding 4Kg per Sqm complete all as specified and as directed.
Mild steel work as in hold fast, wind ties for roof including securing bolts including all necessary drilling ,bolting or reverting etc and all similar work conforming to Fe-290 (Gde E-165) complete all as specified and directed.
Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed.
100mm thick, PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in floor finish, surface finished even and smooth without using extra cement complete all as specified and directed.
Plain cement concrete 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mm thick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved).
Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:6) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. Size/Shade/Colour of tile shall be approved by the GE.
Machine cut kota stone slab flooring 20-25 mm thick of size not less than 550 mm X 550 mm as per sample kept in GE’s office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, as in floor etc, laid over and including 20mm screed layer in cement mortar 1:6, cutting, rubbing, grinding and polishing to achieve mirror finish, laid over PCC subbase complete, all as specified.
Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified.
Rendering cement plaster 20mm thick in cement mortar 1:4 on stone masonry or surface other than fair faces of brick wall or on concrete surfaces, mixed with water proofing admixture as per manufacturer's instructions, trowelled to even and smooth finish without using extra cement complete all as specified. (Note:- WPC will be measured and paid separately as supply only).
Supply only liquid water proofing admixture.
Preparation of wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Preparation of steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with two coats of Creosote oil, complete all as specified and directed.
Preparation of new plastered surfaces or un plastered, previously undecorated wall surfaces and applying two coats of cement base paint, complete all as specified and directed.
Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required.
Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including PVC casing and caping of suitable size (as per conductor run) with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly and including pressed steel terminal boxes made out of 1.20 mm thick mild steel sheet duly painted with one coat of red oxide primer for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete including making good disturbed surfaces to match with existing all as specified and directed.
All as per serial item No '44' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed.
All as per serial item No '44' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed.
All as per serial item No. '44' above but for 3 pin 15 Amps socket out let independent with 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified.
Switch piano flush type, single pole, one way, 5/6 Amps, all as specified.
Switch piano flush type, single pole, two way, 5/6 Amps, all as specified.
Switch piano flush type, single pole, one way, 15/16 Amps, all as specified.
Socket outlet, 2 in 1, 3 pin, 5/6 Amp flush type, all as specified.
Socket outlet, 2 in 1, 5 Pin, 5/15/16 Amp ,flush type, multipurpose, complete all as specified.
Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified.
Lamp holder, PVC/Polycarbonate type with back plate suitable for angular/ batten fittings including LED lamp, 10 watts complete all as specified & directed.
Basic all purpose surface and wall mounted LED tube light fitting integral type 1 x 20W, 230V, connector block etc complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including dismantling of unserviceable tube light all as specified and directed. Havells Cat Part No LUMILINEPLUSBS20WLED865SPCS or equivalent in Bajaj/ CG/ Philips.
MCB TPN 63 Amps, 415 Volts complete all as specified.
MCB SPN 6 to 40 Amps, 240 Volts, 10 KA all as specified.
MCB SP 6 to 32 Amp, 240 Volts, 10 KA all as specified.
Renewal of sheet metal enclosures for DBs when MCBs to be used, triple pole and neutral, 4 way, double door, 415 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified.
Renewal of sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 415 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified.
Renewal of sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 415 volts with 200 Amp rated bus bar including taking down ICDP/ DB's any type, kit kat fuse, MCB's any type, all as specified.
Supply and fixing LED street light fitting 30 Watt ,230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including making connection with aluminium PVC insulated copper wire 2.5 sqmm as required at site and connecting the same to the cable with the help of the connector all as specfied and directed .
Supply and fixing LED street light fitting 35Watt ,230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including making connection with aluminium PVC insulated copper wire 2.5 sqmm as required at site and connecting the same to the cable with the help of the connector all as specfied and directed .
Cutting/ grooving on plinth/ wall/ verandah in any condition for laying of cable through pipe and making good the disturbed surface by using cement concrete 1:2:4 type B-0, using 12.5mm graded crushed stone aggregate as required complete all as directed.
Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed.
Sub class "B" bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed.
GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed.
Renewal of sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded FRLS conductor of size 4 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 4 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly including taking down old unservicable submain wiring, complete and as directed. Note :- Two run (each run of 1 RM) of 4 sqmm copper conductor and one RM of earth wire of 4 Sqmm, shall be measured as one RM).
XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed.
Supply and fix in repair test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled and screwed including 3 nos. 8mm dia 25mm long hex head screw, complete all as specified.
Supply and fix in repair aluminum strip 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground, complete all as specified.
Supply and fix in repair air termination single pointed aluminum rod 12mm dia and 300mm long, complete all as specified.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25mm x 4mm (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I, using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, using 20mm graded crushed stone aggregates, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.
Deduct Credit Amount as per Schedule of credit as details given on Srl Page No 26 of tender doucments.
Gurjit const co
Havish Construction
Pathania Builders
malghotra construction co
SAMTA CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .