Loading…
Loading…
Tender Value
₹2.3 L
EMD Value
₹4,659
Closing Date
12 Jun 2026, 6:55 pm6d left
Executive Engineer MHD Baramulla
Executive Engineer Mechanical and Hospital Division Baramulla
Complete Servicing of Cummins make 320 kVA, 125 kVA, 600 kVA Capacity DG Set and Mahindra make 250 kVA Capacity DG Set installed at Associated Hospital GMC Baramulla
2026_PWDJK_311438_1
MHDB/TS/2026-27/02
Open Tender
Machineries/ Mechanical Engg Items
10 days
GMC Baramulla
Please refer Tender documents.
10 documents required · 10 mandatory
₹200
Executive Engineer, MHD Baramulla
₹4,659
3 Jun 2026
3 Jun 2026
13 Jun 2026
3 Jun 2026
12 Jun 2026
3 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1320 Kva | |||||
| 1.01 | Servicing of 320 Kva Capacity DG Set of Cummins make by way of flushing out contaminated/outdated engine oil from the DG Set, inspection/checking of alternator (dynamo) for proper functioning. The job shall further include complete servicing of radiator by way of cleaning and removing dust, dirt, sludge etc from the fins, soldering of damaged fins, inlet and outlet radiator tanks to plug leakages (if any). The job shall further include testing of DG Set on no load and full load for satisfactory performance. The Job shall include cost on account of HSD Required for testing of the DG Set. | - | Job | - | - |
| 1.02 | Providing and filling of Valvoline premium blue 7800 plus Engine oil as per manufacturer recommendation. | - | Ltrs | - | - |
| 1.03 | Providing and fitting of B Check Kit which includes Lube oil filter 01 no, Fuel filters 2 no’s as per manufacturer recommendation after extracting the existing Filters. | - | Job | - | - |
| 1.04 | Providing and filling of Coolant/anti-freeze (corrosion inhibitor) as per manufacturer recommendation in proper ratio. | - | Ltrs | - | - |
| 1.05 | Providing and fitting of Air Filter Primary element as per manufacturer recommendation After extracting of existing air Filter. | - | Job | - | - |
| 1.06 | Providing and fitting of Air Filter Safety Element as per manufacturer Recommendation after extracting of existing air filter. | - | Job | - | - |
| 2600 Kva | |||||
| 2.01 | Servicing of 600 Kva Capacity DG Set of Cummins make by way of flushing out contaminated/outdated engine oil from the DG Set, inspection/checking of alternator (dynamo) for proper functioning. The job shall further include complete servicing of radiator by way of cleaning and removing dust, dirt, sludge etc from the fins, soldering of damaged fins, inlet and outlet radiator tanks to plug leakages (if any). The job shall further include testing of DG Set on no load and full load for satisfactory performance. The Job shall include cost on account of HSD Required for testing of the DG Set. | - | Job | - | - |
| 2.02 | Providing and filling of Valvoline premium blue 7800 plus Engine oil as per manufacturer recommendation. | - | Ltrs | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.37 MB
NIT02.pdf
Tender Documents • 0.35 MB
BOQ_1008454.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid