| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.8 LAccepted-AOC NEAR NEW BUS STAND ANNI DISTT KULLU H P | ANNI | KULLU | HIMACHAL PRADESH | L1 | Accepted-AOC Lowest Rates | |
| 2 | L2₹47.6 L+₹6.8 L (16.6%)Rejected-Finance MANDI DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹49.2 L+₹8.4 L (20.6%)Rejected-Finance VILLAGE KUTHANI P O SAINJI TEHSIL SUNDERNAGAR DISTT MANDI H P | MANDI | HIMACHAL PRADESH | 175001 | L3 | Rejected-Finance High Rate |
Tender Value
₹37.6 L
EMD Value
₹93,881
Closing Date
20 Aug 2021, 11:00 amClosed
SE OP Circle HPSEBL Bilaspur
SE OP Circle HPSEBL Bilaspur
Tender for the work Survey, Design, Manufacturing, Supply of Material, Erection, Testing and Commissioning of 2X22 KV Metering Equipment Out door type 22 KV CT PT Combined unit, Augmentation of 3 x 22/.4 KV 250 KVA Distribution Sub- Stations,22 KV H.
2021_HPSEB_51033_1
NIT-04/2021-22
Open Tender
Electrical Works
Item Rate
120 days
chhatri
Please refer Tender documents.
12 documents required · 12 mandatory
₹2,950
₹93,881
29 Sept 2021
12 Aug 2021
21 Aug 2021
13 Aug 2021
20 Aug 2021
13 Aug 2021
Amount
22 KV Metering Equipment Outdoor Type (22 KV CT-PT Combined Unit) at Stage I and Stage II.
Prov. 22 KV CT-PT combined unit outdoor,Oil Immersed, Class 0.5 Consisting of three CT on R,Y & B and 1 No. 22 KV/110V PT Class .5 - 20/5A (To be supplied by HPSEBL)
Prov. Energy Meter 22 KV /110V 3Ø CT-PT √ 5&1A- 15/5A (To be supplied by HPSEBL)
Prov. STP Pole 10.00 mtr W/L 200 KG with Base Plate
Prov. RCC Muff of 2000 mm length with C:C for filling
Prov. C.I. X-Arm (100X50X6 mm), Length : 2800 mm X 4 Nos. = 11200 mm Say 11.20 Mtr. for Transformer/ CT-PT base main channel
Prov. M S C.I. (75X40 X 6 mm), Length : 2800 mm X 4 Nos = 11200 mm=11.20 Mtr for supporting DO fuse unit & G.O. Switch
Prov. C.I (100X50 X 6 mm), Length : 460 mm X 2 Nos. = 920 mm = 0.920 Mtrs. for supporting Main Channel of transformer/ CT-PT
Prov. M S A.I X Arm (50X50 X 6 mm) Length 2800 mm x( 1 No. for LA's + 2 Nos. for Distribution Box / Metering Equipment = 2800 X 3 nos.= 8400 mm= 8.40 Mtr.
Prov. CT-PT Belting & Knee Bracing
I) M S A.I (50X50x 6 mm), Length: 2800 mm X 4 Nos.= 11200 mm = 11.20 Mtr (To be supplied by HPSEBL)
II) M S A.I (35X35X 6 mm) Length: 460 mm X 2 Nos.= 920 mm = 0.920 Mtr. (To be supplied by HPSEBL)
Prov. G.O. AB Switch Unit ( 22kV, 400A 25 KA )
Prov. D.O.Fuse Unit
Prov Lightning Arrestor (Surge Arrester, 18kV Station Class Porcelain Type )
Prov. Discs Insulator sets (Comprising 2 Nos. Disc: ^^ (Porcilain, BS, 12 kV 90 kN) i/c Dead End Clamps etc.)
Prov. Stay Set complete
Prov. Stay Wire 7/4.00 mm ( @6.00 / 9.0 kg Per Stay Set)
Prov. Pipe Earthing set (With G.I. Strips 50x6mm,40x6mmx 25x6mm)
Prov. Full Clamp with Nuts & Bolts ( M.S. Flat Iron 50X6 mm )
Prov. Half Clamp with Nuts & Bolts (M.S. Flat Iron 50X6 mm)
Prov. Nuts and Bolts of Various Sizes Galvanised / Coated) (Prefeably 16 mm ɸ or more with flat and Spring Washers)
Prov. Alluminium Thimble
Prov. ACSR Cond. 6/1/3.35mm2
Prov. Danger Plate
Prov. Aluminium Paint
Prov. Chain Link Fencing, Angle Iron, Gate etc. for CT-PT fencing
Prov. PVC 4 mm sq copper wire
Prov. G.I. Pipe 1 1/4" dia
Prov. Elbow
Prov Nipple
Prov.G.I.Gland
Prov. Meter Box
Extra manual carriage charges for Stage I and Stage II from Road head to Site of Work for an average lead = 0.100+0.100=0.200 Kms
22/.4 KV, 3X 250 KVA Transformer at Stage I and Stage II.
Prov. 22/0.4 kV 250 KVA Distribution Transformer (To be supplied by HPSEBL)
Prov. M.S. A.I X Arm (50x50x5mm) Length 2800 mm x2 for Energy Meter + 2 Nos. Distribution Box.
Prov. Pipe Earthing
Prov. LT Distribution Panel Box with MCCB (400A, 36kA, 4P, 1No.) and SFU (100A, 4No., rewirable)
Prov. LT Distribution Panel Box with MCCB (630A, 50kA, 4P, 1No.) and SFU (100A, 6 No., rewirable)
Prov. Half Clamp with Nuts & Bolts (M.S. Flat 50X6 mm)
Prov. M.S. Nuts and Bolts of various sizes (galvanised/ Coated) (Preferably 16 mm ɸ or more (With Flat & Spring Washers))
Prov. Aluminium. Thimble
Prov. Aluminium. Thimble
Prov. Danger Plate
Prov. LT Cable (3.5 Core) 240 mm2
Prov. LT Cable (3.5 Core) 185 mm3 (To be supplied by HPSEBL)
Prov. Energy Meter LT, 3-Phase, 4 Wire CT OperatedStatic Trivector Meter ( CT-300-400/5A) Accuracy Class: 0.5S, Category-C, DLMS Compliant.
Prov. Energy Meter LT, 3-Phase, 4 Wire CT OperatedStatic Trivector Meter ( CT-500-600/5A) Accuracy Class: 0.5S, Category-C, DLMS Compliant.
Prov. Aluminium Paint.
Extra manual carriage charges for an Average Lead 1.000 Km. from Road Head to Site of Work with an average lead = 0.100+0.100=0.200 Kms
22 KV H.T Line on ST Pole for Stage I and Stage II.
Prov. Steel Tubular Pole 9.00 mtr W/L 200 KG with Base Plate
Prov. RCC Muff with Concrete Filling 2000mm length.
Prov. ACSR Cond. 50 mm2 (6/1/3.35mm)
Prov. G.I.No. 6/ 8 SWG for Earth wire for PCC & S/T Pole
Prov. 22 KV Pin Insulator with Pin Hellically formed fitting (Porcelain, 24kV, 10kN) (To be supplied by HPSEBL)
Prov. Disc Insulator Set (Comprising 2 No. Disc:^^ ( Porcelain, BS, 12kV, 90kN i/c dead end clamps etc.)
Prov. C.I. X-arm(100x50x6mm),Length: 2800x21=58800 mm =58.80 Mtr for Double Pole Str.
Prov. C.I.X-arm (100x50x6mm), Length(1800) for S.Pole Str.=1800 x8=14400mm=14.40 Mtr
Prov. A.I.X-arm(50x50x6mm), Length:2100 x1 = 2100 mm = 2.10 Mtrs. for Gaurding
Prov. A.I.X-arm(50x50x6mm), Length : 3000 x 8= 24000 mm = 24.00 Mtrs.for Gaurding
Prov. A.I Knee Bracing set (50x50x6mm), Length (2x850) for Single Pole = 850 x 2 x2= 3400 mm = 3.40 Mtr. (To be supplied by HPSEBL)
Prov. Belt Set (X-Bracing Set)M S Angle Iron(50x50x6mm)Length:1500x2x9 = 27000 mm = 27.00 Mtrs.
Prov. Belt Set (X-Bracing Set)M S Angle Iron(50x50x6mm) Length: 2700x2x9= 48600 mm= 48.60 Mtrs.
Prov. Stay Set Complete in all respect i/c Guy Assembly with Helically Fitting
Prov. Stay Wire 7/3.15 mm/ 7.400 mm ( @ 6.0 KG /9.00 Kg per Stay Set)
Prov. H.T. Earthing for PCC /S/T Pole
Prov. Full Clamp with nuts & bolts M.S. Flat 50x6 mm
Prov. Half Clamp with nuts & bolts M.S. Flat 50x6 mm
Prov. Pole Top Clamp with nusts & bolts M.S .Flat 50x6 mm
Prov. Earth Hook for Earth Wire
Prov. Danger Plate (250x200x1.6 mm)
Prov. Nuts & Bolts Of various sizes ( Gaivanised/ Coated) ( Preferably 16 mmɸ or more with flat and spring washers)
Prov. Barbed Wire
Prov. Alluminium Paint
Prov. G.O. AB Switch Unit ( 22 kV, 400A, 25kV)
Extra manual carriage charges for 1.00 Km.from Road head to Site of Work. Average lead - 1.300 Km for 0.550 Km Line= 1.300 X 0.550=0.715 P/Kms
Re-Conductoring of 22 KV H.T Line from Bahwa to Lagat at Stage I and Stage II.
Prov. ACSR Cond. 50 mm2 (6/1/3.35mm)
Prov. Dead End Clamp for ACSR Cond. 50 mm2 (6/1/3.35mm)
Prov. C.I.X-arm (100x50x6mm), Length(1800) for S.Pole Str.= 1800 x6= 10800mm = 10.80 Mtr
Prov. C.I. X-arm(100x50x6mm),Length: 2800x5=14000 mm = 14.0 Mtr for Double Pole Str.
Prov. Belt Set (X-Bracing Set)M S Angle Iron(50x50x6mm)Length:1800x2x1= 3600 mm = 3.60 Mtrs.
Prov. Belt Set (X-Bracing Set)M S Angle Iron(50x50x6mm) Length: 2700x2x1 =5400 mm = 5.40 Mtrs.
Prov. 22 KV G.O. AB Switch Unit (22 KV, 400A, 25 KA)
Prov. 11 KV Fault Path Indicator
Extra manual carriage charges for 1.00 Km.from Road head to Site of Work. Average lead - 0.500 Km for 15.990 Km Line= 0.500 X 15.990=7.995 P/Kms
Transformer Plinth including Fencing around the yard for 11 KV Metering Equipment & 3x22/.4 KV 250 KVA S/Stn. for Stage I and Stage II.
Prov. Excavation in foundation, trenches etc. in earth work, lift up to 1.50 mtrs, stacking the excavated soil not more than 3.00 mtrs clear from the edge of excavation & then returning the stacked soil in 15 cm layers, when required into plinths sides of foundation etc. consolidating each deposited layer by ramming & watering and then disposing of all surplus excavated earth as directed Pick & jumper work 50% : 50%
P/L Cement concrete 1:6:12 (1 Cement : 6 Sand : 12 graded stone agg. 40 mm nominal size) & curing complete – In foundation
Prov. Brick work using common burnt clay building bricks in foundation & plinth in cement mortar 1:4 (1 Cement : 4 Sand)
P/L Cement concrete work 1:5:10 ( 1 Cement : 5 Sand : 10 graded stone agg. 40 mm nominal size) with 15% plum & curing complete excluding the cost of form work, the size of plums shall usually be 150 mm to 300 mm as per HPPWD specification.
P/L Cement concrete 1:2:4 ( 1 Cement : 2 Sand : 4 graded stone agg. 20 mm nominal size) & curing complete including the cost of form work
Prov.15mm cement plaster in single coat on fair side of brick/conc./stone masonry wall for internal plastering up to to floor two level including arises , internal rounded angle, chamfer and /or rounded angle not exceeding 80mm in girth and finished even and smooth in cement mortar 1:4 (1 cement :4 sand)
Supplying & fixing woven plains G.I. Wire fencing of Mesh 50 MM to 150 MM to any type of standard rails, straining posts etc. i/c provision of binding wire, steples, M.S. Angle Posts etc. complete in all respect.
Meterial to be Dismantled from existing 22 KV H.T. Line from Bahwa to Lagat at Stage-I
Removal of conductor, De-Stringing & Rolling of Conductor ACSR Cond. 6/1/2.11 mm / AAAC 7/2.50 mm (30 mm2) and Transportation from Site to Divisional Store Karsog.
TILAK RAJ
CONT ANIL KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .