Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹15.2 L+₹2.9 L (23.3%)Rejected-AOC 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹15.4 L+₹3.1 L (24.7%)Rejected-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹16.2 L+₹3.8 L (30.7%)Rejected-AOC H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹16.2 L+₹3.8 L (30.9%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) No 02 Jodhpur
GE (AF) No 02 Jodhpur
Repair and maint/ replacement of external lights including misc E/M assets and allied works under AGE E/M, GE (AF) No 02 Jodhpur
2024_MES_652702_1
8456/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE (AF) No 02 Jodhpur
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (AF) No 02 Jodhpur
₹40,000
Yes
23 Jul 2024
7 May 2024
5 Jun 2024
7 May 2024
3 Jun 2024
22 May 2024
14 May 2024 - 21 May 2024
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge.
Removing of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M/&L for stone slab 40 to 50 mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 30 cm wide and not less then 50 cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning all as specified and directed by Engr-in-Charge.
M&L for Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of PVC underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4 core.
S&F in replacement of PVC underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4 core.
S&F in repair of MCCB 4 Pole , 415 V, Adjustable type,630 Amps with breaking capacity 36 KA .
S&F IN repair of MCCB 4 Pole , 415 V, Adjustable type,400 Amps with breaking capacity 36 KA .
S&F in repair of MCCB 4 Pole , 415 V, Adjustable type,250 Amps with breaking capacity 36 KA .
S&F in repair of MCCB 4 Pole , 415 V, Adjustable type,200 Amps with breaking capacity 36 KA .
S&F in repair of MCCB 4 Pole , 415 V, Adjustable type,160 Amps with breaking capacity 36 KA .
S&F in repair of MCCB 3 Pole , 415 V, Adjustable type,100 Amps with breaking capacity 36 KA .
Supply and replace sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.
Supply and replace Sheet metal enclosure distribution board TPN, 415 volts, 4 way Horizontal/vertical type as per site requirement, double door type, 200 Amps rated neutral copper bus bar for housing MCBs and including provision for fixing TPN MCB as incommer, DB fixed flush or in wall surface including making good to damaged surface of wall to match with existing specification complete including taking out old all as specified all as specified and directed. Note : MCB SP/SPN/TPN will measured and paid separately under relavant item.
Taking down carefully light fitting any type from surface/recessed/wall mounting type stacking at site for re-use or shifting unserviceable lights to store for taking credit all as directed and specified.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as per crompton cat ref no. LCTLR-36-FO-CDL or equivalent in approved makes.
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 35 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL35W or equivalent model approved makes.
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 60 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL60W or equivalent model approved makes.
Supply and fixing pyramid shape integral decorative as garden light with ip 65 degree of protection of capacity 9 watt LED with all accessories complete errect/fixed/mount properly at directed place with reqd fixing/mounting arrangement and connecting/testing complete all as specified by Engr-in-Charge. Make -Crompton.
Supply and fixing post top lantern LED type 20 Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
NOTES FOR LED LIGHT FITTINGS & BULBS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
Supply & connect PVC flat twin core cable, black sheathed, stranded aluminium conductor 4.0 Sqmm complete all as specified and directed.
Supply & connect PVC flat twin core cable, black sheathed, stranded aluminium conductor 6.0 Sqmm complete all as specified and directed.
Supply & connect PVC flat twin core cable, black sheathed, stranded aluminium conductor 10.0 Sqmm complete all as specified and directed.
M&L for Sub main wiring with approved colour coding as per IS, single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for following sizes of wires :-.(a) Two runs of 6.0 Sq.mm main cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in and including PVC Casing and Caping, GI terminal boxes 1.2mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed for following : Note- Point wiring should be either concealed or casing caping as directed by engineer in charge.
One light point/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & electronic type fan regulator.
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
One 3 pin 5 Amp switch & socket outlet on Independant board.
All same as per item ser No 28.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board.
S&F (in repairs) Switch piano, flush type, single pole, one way, 6 Amp.
S&F (in repairs) Socket outlet 2/3 pin, 2-in-1, 5/6 Amp, flush type.
S&F(in repairs) Switch Socket combination outlet 6 pin, 6/16 Amp, flush type
S&F(in repairs) Ceiling rose surface bakelite 65x50mm three terminal.
S&F(in repairs) Stepped type electronic fan regulator, socket size, flush type 230V AC.
S&F(in repairs) switch modular single pole one way 6 Amps 230 volt 1 module.
S&F(in repairs) switch modular single pole one way 16 Amps 230 volt 1 module.
S&F(in repairs) Socket modular 6 Amp 2/3 pin combined two module.
S&F(in repairs) Socket modular 6&16 Amp 2/3 pin combined two module.
S&F(in repairs) electronic fan regulator modular stepped type 120 watt, two module.
Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate) complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB TPN/FP, 40 to 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
SANJOLI CONSTRUCTION COMPANY
KRISHNA CONSTRUCTION COMPANY
Shri Electrical Enterprises
M/S VENUS BUILDER
GITANSH ENGINEERS AND COMPANY
VARDHMAN SALES CORPORATION
M/s Vishaka Enterprises
RISING ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .