Loading…
Loading…
Tender Value
₹2.1 Cr
EMD Value
₹4.2 L
Closing Date
21 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
+ Capital Works)
Above/Below/Par
WA
16 conditions · 5 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB of Indian Railways Standard General Conditions of Contract, GCC - April 2022, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Similar work shall mean by "Electrification / Rewiring of Station / Building/ Project / Yard etc."
4 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The intended tenderer shall get digital signature certificate and get registered with Rly. For new vendors, the procedure is described in Rly. Website www.ireps.gov.in. The tender shall be submitted in Rly website www.ireps.gov.in not later than stipulated time and date of tender closing. After closing of the tenders at stipulated time the tenders shall be opened on the same date. In case the date of tender opening happens to be holiday, the tender shall be opened on the next working day in the same manner.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society /Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall attached all documents pertains to status of firm i.e Partnership deed, Power of attorney, Resolution of Board of Director's etc. as applicable as per GCC.
Electrical work in connection with upgradation of illumination at Railway Colony play ground at Gandhidham and provision of inverter-operated LED tube lights at platforms and passenger movement areas and enhancement of safety by earthing over Ahmedabad Division.
EL-ADI-G-T-36-2026-27~WR
EL-ADI-G-T-36-2026-27
Open
Works - General
12 Months
Ahmadabad, Gujarat
₹0
₹4.2 L
22 Sept 2026
22 Sept 2026
7 Oct 2026
52 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,24,62,773 | ||
| details. | Breakup for | — | — | ||
| Supply, installation, testing and commissioning of high-quality sports LED floodlight (integrated type only) with a minimum system lumen pack of 48000Lm - 52000Lm, while system wattage not exceeding 400W (±2%). Luminaires should be with suitable optics to achieve required lux level, with CCT of 5700K with SDCM <5 complete with all required accessories as per technical specifications shown in Para (A) of Annexure. | — | — | — | 39,21,000 | |
| details. | Breakup for | — | — | ||
| Supply, installation, testing and commissioning of high-quality sports LED floodlight (integrated type only) with a minimum system lumen pack of 180000Lm - 195000Lm, while system wattage not exceeding 1500W (±2%). Luminaires should be with suitable optics to achieve required lux level, with CCT of 5700K with SDCM <5 complete with all required accessories as per technical specifications shown in Para (B) of Annexure. | — | — | — | 7,83,416 | |
| details. | Breakup for | — | — | ||
| Supply, installation, testing and commissioning of polygonal 30 meter stadium mast system (25Mtr height with 05 Mtr head frame) divided into 3 sections, totally hot dip galvanized inside and outside in single dip, suitable for withstanding wind velocity as per IS 875 or latest prevailing in the region. The mast shaft shall be in two sections with one longitudinal seam weld, per section and no circumferential weld which can be jointed by slip stress method as per technical specifications shown in Para (C) of Annexure. | — | — | — | 27,68,364 | |
| details. | Breakup for | — | — | ||
| Digging of cable trench 450 x 1000 mm & refilling as per technical specification shown in Para (D) of Annexure. | — | — | — | 20,200 | |
| details. | Breakup for | — | — | ||
| Transportation, laying, installation, terminating, testing and commissioning of LT/HT cable of sizes 4 core 10 Sq. mm to 4 core 300 Sq. mm in existing trench, pipe or on structure as per technical specification shown in Para (E) of Annexure. | — | — | — | 7,600 | |
| details. | Breakup for | — | — | ||
| Supply and laying of half round RCC pipe 150 mm. ID & 1 mtr. length as per technical specification shown in Para (F) of Annexure. | — | — | — | 14,200 | |
| details. | Breakup for | — | — | ||
| Supply, installation, testing and commissioning of LT cable route marker as per technical specification shown in Para (G) of Annexure. | — | — | — | 3,135 | |
| details. | Breakup for | — | — | ||
| Horizontal Direction Drilling/boring without damage of surface road using auger machine the bore shall be 150mm dia. and shall be done at the depth of minimum 1.5meter or as requirement of site from the ground level this include insertion of 110mm dia. HDPE pipe as per technical specification shown in Para (H) of Annexure. | — | — | — | 27,67,500 | |
| details. | Breakup for | — | — | ||
| Supply, installation, testing and commissioning of HDPE pipe 110 mm nominal dia. as per IS 4984-1995 and as per technical specification shown in Para (H) of Annexure. | — | — | — | 15,30,000 | |
| details. | Breakup for | — | — | ||
| Supply of material and providing maintenance free earthing as per technical specification shown in Para (I) of Annexure. | — | — | — | 1,19,500 | |
| details. | Breakup for | — | — | ||
| Supply of material and carry out concealed wiring of Light/Fan points without pipe up to 6 meters with FRLS PVC insulated, multi strand three Nos. copper wires of 1.5 Sq. mm for phase, neutral and earth continuity conforming to IS-694 (as amended latest). The point wiring shall include supply & providing modular switches with complete associate accessories such as chromium plated metal boxes, modular plates, cover plate, lamp holders, three pin ceiling rose, adopter etc. as per technical specification shown in Para (J) of Annexure. Note: Beyond 6 meter wiring additional payment will be done through NS item. | — | — | — | 2,934 | |
| details. | Breakup for | — | — | ||
| Supply and laying in wall & ceiling in concealed manner of ISI marked medium class rigid 25 mm dia. PVC conduit pipe with all accessories as per technical specification shown in Para (J) of Annexure. | — | — | — | 980 | |
| details. | Breakup for | — | — | ||
| Supply, fixing, testing and commissioning of 6 Amps multi pin modular socket with modular switch in concealed manner on an existing board where phase and neutral are already available as per technical specification shown in Para (J) of Annexure. | — | — | — | 354 | |
| details. | Breakup for | — | — | ||
| Supply, fixing, testing and commissioning of 4 Nos. 6 Amps multipin modular socket with modular switch for each socket on separate board in concealed manner with all accessories as per technical specification shown in Para (J) of Annexure. | — | — | — | 1,410 | |
| details. | Breakup for | — | — | ||
| Supply, fixing, testing and commissioning of 16 Amps multi pin socket with modular switch in concealed manner on separate board with all accessories as per technical specification shown in Para (J) of Annexure. | — | — | — | 904 | |
| details. | Breakup for | — | — | ||
| Supply of materials and wiring of main/sub main in concealed manner with 4 mm Sq. size multistrand FRLS PVC insulated ISI marked copper wire for phase, neutral & one number 2.5 Sq. mm copper wire for earth continuity with PVC conduit pipe as per technical specification shown in Para (J) of Annexure. | — | — | — | 4,825 | |
| details. | Breakup for | — | — | ||
| Supply of 5 star rated 1200 mm BLDC ceiling fan as per technical specification shown in Para (K) of Annexure. | — | — | — | 7,482 | |
| details. | Breakup for | — | — | ||
| Fixing, testing and commissioning of fan with supply, fixing, testing and commissioning of EME type fan regulator as per technical specification shown in Para (K) of Annexure. | — | — | — | 966 | |
| details. | Breakup for | — | — | ||
| Supply, installation, testing and commissioning of 20W LED tube light fitting IP 20 complete with tube and all accessories. The contractor shall provide the mounting arrangement for fittings as required at site and as per technical specification shown in Para (L) of Annexure. | — | — | — | 2,484 | |
| details. | Breakup for | — | — | ||
| Supply, installation, testing and commissioning of 45 watt LED street light fitting IP 66 complete with all accessories. The contractor shall provide the mounting arrangement for fittings as required at site and as per technical specification shown in Para (L) of Annexure. | — | — | — | 12,848 | |
| details. | Breakup for | — | — | ||
| details. | Breakup for | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
RDSOguidelineforinvertertubelight1.pdf
ATTACHMENT
PdfACS12GCC2022.pdf
ATTACHMENT
E BG policy
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
T_36_doc_GIMupgradeilluminationinverterTL.pdf
ATTACHMENT
GCCwithACS11.pdf
ATTACHMENT
BGFormate.pdf
ATTACHMENT
e-BGPolicyinEPCGCCPMSPSSAGCPGMSDated16.06.2026.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .