Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-Finance BLDG NO 02 ALACKAPARAMBIL THODAYIL THURAVOOR THEKKU THURAVOOR POST ALAPPUZHA KERALA 688532 | ALAPPUZHA | ALAPPUZHA | KERALA | 688532 | L1 | Accepted-Finance Accepted being lowest and reasonable | |
| 2 | L2₹47.8 L+₹3.4 L (7.69%)Rejected-Finance CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L2 | Rejected-Finance Rejected due to not being L1 | |
| 3 | L3₹48.4 L+₹4.0 L (9.12%)Rejected-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L3 | Rejected-Finance Rejected due to not being L1 | |
| 4 | L4₹48.9 L+₹4.5 L (10.2%)Rejected-Finance 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L4 | Rejected-Finance Rejected due to not being L1 | |
| 5 | L5₹49.2 L+₹4.8 L (10.8%)Rejected-Finance 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | ERNAKULAM | ERNAKULAM | KERALA | 682010 | L5 | Rejected-Finance Rejected due to not being L1 |
Tender Value
₹49.8 L
EMD Value
₹99,600
Closing Date
16 Jul 2025, 6:00 pmClosed
GE(NW)KOCHI
GARRISON ENGINEER (NW) MILITARY ENGINEER SERVICES NAVAL BASE POST -682 004
AS PER BOQ AND TENDER DOCUMENT
2025_MES_716421_1
8488_GE_NW
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
KOCHI
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(NW)KOCHI
₹99,600
19 Jul 2025
24 Jun 2025
19 Jul 2025
24 Jun 2025
16 Jul 2025
10 Jul 2025
24 Jun 2025 - 16 Jul 2025
Amount
Taking down copper/aluminium point wiring (light, fan, socket,bell,power point) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
Material and Labour for light/fan point wiring using approved colour coding as per IS( Red,Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLSH cable 1100 volts grade including PVC casing and capping and connected accessories ISI marked with concealed sunken boxes with modular cover plate, PVC boxes, hylem sheet,including 1.5 sq mm nominal cross sectional area PVC insulated copper conductor unsheathed FRLSH cable single core multistranded cable as earth continuit wire for one light/fan point controlled by one switch complete all as specified and as directed.
All as per Item No.2 here-in-before but for one bell point controlled by one push button on independent board complete all as specified and as directed.
All as per Item No.2 here-in-before but for 5 pin 5 Amps socket outlet point on independent board complete all as specified and as directed.
All as per Item No.2 here-in-before but for 5 pin 5 Amps socket outlet point on same board complete all as specified and as directed.
All as per Item No.2 here-in-before but using 2.5 Sq.mm copper conductor (mulitstranded) PVC insulated FRLSH unsheathed cable including 2.5 Sq.mm copper conductor cable(mulitstranded) PVC insulated FRLSH unsheathed cable as earth wire with terminal box of suitable size of modular switch & socket for one 6 pin 15 amp socket outlet point on independent board complete all as specified and as directed.
Material and Labour point wiring for one light/fan point with 1.5 Sq.mm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 Sq.mm PVC (FRLSH) insulated unsheathed copper cable multistranded conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC conduit medium grade ISI marked concealed of suitable size with all accessories and suitable factory made modular box for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surfaces and matching to the existing finishes specifications complete all as specified and as directed.
All as per item No. 7 here in before but for one bell point controlled by one 5 Amp bell push on independent board complete all as specified and as directed.
All as per item No. 7 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and as directed.
All as per item No. 7 here in before but for one 5 pin 5 Amp socket outlet point on the same board complete all as specified and as directed.
All as per Item No.7 here-in-before but using 2.5 Sq.mm copper conductor (mulitstranded) PVC insulated FRLSH unsheathed cable including 2.5 Sq.mm copper conductor cable(mulitstranded) PVC insulated FRLSH unsheathed cable as earth wire with terminal box of suitable size of modular switch & socket for one 6 pin 15 amp socket outlet point on independent board complete all as specified and as directed.
S&F modular Bell Push 6A, 1 module, complete all as specified and as directed.
S&F modular switch 6 Amps 240 volts one way switch complete all as specified and as directed.
S&F switch modular type AC 240 Volts 16 Amps one way complete all as specified and as directed.
S&F socket 6A-2/3 pin combined AC 240 Volts modular type complete all as specified and as directed.
S&F socket 16 Amp-5 pin combined AC 240 Volts modular type complete all as specified and as directed.
S&F socket 6 Amps 240 Volts one way switch complete all as specified and as directed.
S&F switch piano type 6 Amps 240 Volts one Way switch complete all as specified and as directed .
S&F bell push flush type 5 Amps single pole complete all as specified and as directed.
S&F Fan Regulator , modular electronic rotary 0-4 steps step type 100 Watt, 240 Volt 50 Hz ,2 module complete all as specified and as directed.
S&F fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed
S&F ceiling rose surface bakelite 65x50 mm, 3 terminals complete all as specified and as directed.
S&F in repair, switch piano flush type single pole one way 5 Amp complete all as specified and as directed.
S&F in repair, bell push flush type 5 Amps single pole complete all as specified and as directed.
S&F in repair, switch piano flush type single pole one way 15 Amp complete all as specified and as directed.
S&F in repair, socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and as directed.
S&F in repair, socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and as directed.
Supply and Fix in repair, switch socket combination 5, 5 pin, 2 in 1 complete all as specified and as directed.
S&F in repair, switch socket combination 5 & 15 Amps, 5 pin, 2 in 1 complete all as specified and as directed.
S&F in repair, switch socket combination 5, 6 pin, 2 in 1 box type complete all as specified and as directed.
S&F in repair, switch socket combination 5 & 15 Amps, 5 pin, 2 in 1 box type complete all as specified and as directed.
S&F in repair hylem sheet with required size and type with minimum standard thickness for piano type switches,sockets and regulators complete all as specified and as directed.
S&F in repair switch modular 6 Amps 240 Volts one way switch complete all as specified and as directed.
S&F in repair Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type complete all as specified and as directed.
S&F in repair Socket 6A/16 Amps-2/3 pin combined AC 240 Volts modular type complete all as specified and as directed.
S&F in repair Switch modular type AC 240 volts 16 Amps one way complete all as specified and as directed.
S&F in repair Fan Regulator, modular electronic rotary,0-4 steps step type 100 Watt, 240 Volt 50 Hz hum free 2 module complete all as specified and as directed.
S&F in repair ceiling rose surface bakelite 65x50 mm, 3 terminals complete all as specified and as directed.
S&F in repair, electric bell ,Buzzer,Ding dong AC 230 Volt single pole complete all as specified and as directed.
S&F in repair sunken box with Modular white cover plate 2 module with removing old type sunken boxes/wooden board and match with exisiting surfaces, complete all as specified and as directed.
S&F in repair sunken box with Modular white cover plate 3 module with removing old type sunken boxes/wooden board and match with exisiting surfaces complete all as specified and as directed.
S&F in repair sunken box with Modular white cover plate 4 module with removing old type sunken boxes/wooden board and match with exisiting surfaces complete all as specified and as directed.
S&F in repair sunken box with Modular white cover plate 6 module with removing old type sunken boxes/wooden board and match with exisiting surfaces complete all as specified and as directed.
S&F in repairs sub main wiring with 4 runs of 10 Sq.mm PVC Insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI marked, medium grade, non metallic, PVC Casing & Capping and all accessories, with 1 run of 10 Sq.mm PVC insulated unsheathed multi stranded single core copper conductor FRLSH and making good disturbed surfaces, applying distemper/Emulsions matching to the existing colour/quality of walls/floors/ceiling etc complete all as specified and as directed. Note: Five runs of 10Sqmm cable and one run of PVC casing and caping shall be measured as one unit.
S&F in repairs sub main wiring with 2 runs of 10 Sq.mm PVC Insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI marked, medium grade, non metallic, PVC Casing & Capping and all accessories, with 1 run of 10 Sq.mm PVC insulated unsheathed multi stranded single core copper conductor FRLSH and making good disturbed surfaces, applying distemper/Emulsions matching to the existing colour/quality of walls/floors/ceiling etc complete all as specified and as directed. Note: Three runs of 10Sqmm cable and one run of PVC casing and caping shall be measured as one unit.
All as per Item No.45 here-in before but 2 runs of 6 Sq.mm single core FRLSH copper conductor and 1 run of 6 Sq.mm Condutor for earthing complete all as specified and as directed. Note: Three run of cable and one run of PVC Casing and caping shall be measured as one unit
All as per Item No.45 here-in before but 2 runs of 4 Sq.mm single core FRLSH copper conductor and 1 run of 4 Sq.mm Condutor for earthing complete all as specified and as directed. Note: Three run of cable and one run of PVC Casing and caping shall be measured as one unit
All as per Item No.45 here-in before but 2 runs of 2.5 Sq.mm single core FRLSH copper conductor and 1 run of 4 Sq.mm Condutor for earthing complete all as specified and as directed. Note: Three run of cable and one run of PVC Casing and caping shall be measured as one unit
S&F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core with necessary fittings and fixtures for laying on wall/trenches/pipe complete all as specified and as directed.
S&F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 2 core with necessary fittings and fixtures for laying on wall/trenches/pipe complete all as specified and as directed.
S&F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core with necessary fittings and fixtures for laying on wall/trenches/pipe complete all as specified and as directed.
S&F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core with necessary fittings and fixtures for laying on wall/trenches/pipe complete all as specified and as directed.
S&F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 4 core with necessary fittings and fixtures for laying on wall/trenches/pipe complete all as specified and as directed.
S&F in repair SPN enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA, complete all as specified and as directed.
S&F in repair triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 32 Amps having breaking capacity 10 kA, complete all as specified and as directed.
S&F in repair triple pole enclosure with three pin and earth plug and socket complete with one TP MCB, 63 Amps having breaking capacity 10 kA, complete all as specified and as directed.
S&F in repair 20 Amp to 32 Amp top plug Assembly of industrial socket of any type complete all as specified and as directed.
S&F in repair 6 Amp top plug socket any type complete all as specified and as directed.
S&F in repair 16 Amp top plug socket any type complete all as specified and as directed.
S&F in repair Sheet Metal Enclosure for MCB DB, SPN 4 Ways double door,with 200 Amps rated bus bar , having IP-43 protection complete all as specified and as directed.
S&F in repair Sheet Metal Enclosure for MCB DB, SPN 8 Ways double door,with 200 Amps rated bus bar , having IP-43 protection complete all as specified and as directed.
S&F in repair Sheet Metal Enclosure for MCB DB, SPN 12 Ways double door,with 200 Amps rated bus bar , having IP-43 protection complete all as specified and as directed.
S&F in repair Sheet Metal Enclosure for MCB DB, TPN 4 Ways double door,with 200 Amps rated bus bar , having IP-43 protection complete all as specified and as directed.
S&F in repair Sheet Metal Enclosure for MCB DB, TPN 8 Ways double door,with 200 Amps rated bus bar , having IP-43 protection complete all as specified and as directed.
S&F in repair Vertical TPN DB 4 Way with provision for incoming MCCB/MCB 4 pole with 200 Amps rated bus bar , having IP-43 protection complete all as specified and as directed.
S&F in repair Vertical TPN DB 6 Way with provision for incoming MCCB/MCB 4 pole with 200 Amps rated bus bar , having IP-43 protection complete all as specified and as directed.
S&F in repair Vertical TPN DB 8 Way with provision for incoming MCCB/MCB 4 pole with 200 Amps rated bus bar , having IP-43 protection complete all as specified and as directed.
S&F in repair 230 V 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 Amp to 32 Amps in the DB Complete with connection testing and commissioning complete all as specified and as directed.
S&F in repair 230 V 10 KA 'B' curve miniature circuit breaker (MCB) of two poles and current carrying capacity 32 Amp to 100 Amps in the DB Complete with connection testing and commissioning complete all as specified and as directed.
S&F in repair 415 V 10 KA 'B' curve miniature circuit breaker (MCB) of three pole and current carrying capacity 25 Amp to 63 Amps in the DB Complete with connection testing and commissioning complete all as specified and as directed.
S&F in repair 415 V 10 KA 'B' curve miniature circuit breaker (MCB) of four poles and current carrying capacity 40 Amp to 100 Amps in the DB Complete with connection testing and commissioning complete all as specified and as directed.
S&F MCCB 3P 100 Amps thermal magnetic 25 kA ccomplete all as specified and as directed.
S&F MCCB's FP 100 Amps thermal magnetic 25 kA complete all as specified and as directed.
S&F MCCB's FP 125 Amps thermal magnetic 25 kA complete all as specified and as directed.
S&F MCCB's FP 163 Amps thermal magnetic 25 kA complete all as specified and as directed.
S&F MCCB's FP 250 Amps thermal magnetic 25 kA complete all as specified and as directed.
S&F light fitting 20 W,high performance batten, 220 Volt, 50 Hz, 6000 k 120 Iu/W surface mounted high quality extruded polycarbonate , environmental friendly, energy efficient , with all connecting accessories, with suitable connection complete all as specified and as directed.
S&F in repair 20 Watt LED tube rod with double side with batten, universal type, 230 V, 50 Hz, Wall surface, roof surface including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and as directed. Make: CAT Part No.REGALBATTENT8UPTO1X22WSSBSWH (frame) & CAT Part No. CRYSTALT81213SSTL20WLED865SGLASS (Tube) of Havells or any other make from the approved list of manufactures.
S&F in replacement mirror light 10 Watt 50 Hz,230 volts with all accessories and connection to the electric circuit complete all as specified and as directed.
S&F in replacement mirror light 12 Watt 50 Hz,230 volts with all accessories and connection to the electric circuit complete all as specified and as directed.
S&F in repair 20 watt led tube frame for single side/double side tube rod 230 Volts,50 Hz, min 120 lum/watt with batten,universal type on wall/roof surface including connected accessories including provision of flexible copper wire from ceiling rose to light fitting terminals with all fittings and fixtures complete all as specified and as directed.
S&F in repair 20 watt led tube rod single side type with 230 Volts,50 Hz, min 120 lum/watt with all fittings and fixtures complete all as specified and as directed.
S&F in repair 20 watt led tube rod double side type with 230 Volts,50 Hz, min 120 lum/watt with all fittings and fixtures complete all as specified and as directed.
S&F in repairs recess mounted commercial luminaire 36 Watt,50 Hz, 220 Volts, 5700K LED down lighter 2'x2', complete all as specified and as directed. Make: Cat Part No. LCTRH-36-FO-CDL of Crompton or any other make from the approved list of manufactures.
S&F in repair recess mounted/surface mounted commercial luminaire 36 Watt,50 Hz, 220 Volts, 5700K LED down lighter 2'x2', complete all as specified and as directed. Make: CAT PART No. LCTRNE-36-FO-CDL of Crompton or any other make from the approved list of manufactures.
S&F in repair circular highbay LED light 80 Watt, 240 Volt ,min lumens 120 Lu/W, IP 66 including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and as directed.
S&F in repair LED Flood light 30 Watt, 50 Hz,220 Volts having IP-66 Protection , pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and as directed.
S&F in repair LED Flood light 50 Watt, 50 Hz,220 Volts having IP-66 Protection , pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and as directed.
S&F in repair LED Flood light 100 Watt, 50 Hz,220 Volts having IP-66 Protection , pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and as directed.
S&F in repair LED Building Security Light 90 Watts, 50 Hz, 220 Volts having IP-65 Protection, pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and as directed.
S&F in repair LED Building Security Light 60 Watts, 50 Hz, 220 Volts having IP-65 Protection , pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and as directed.
S&F in repair LED Building Security Light 45 Watts, 50 Hz, 220 Volts having IP-65 Protection , pressure die cast aluminium housing,high luminious efficiancy and high power complete all as specified and as directed.
S&F in repair 15 Watt recessed round down lighter with high luminous LED for indoor application, 230 Volts, 50 Hz, min 100 lm/watt with all accessories and connection to the electric circuit complete all as specified and as directed. Make: Cat part no. LCDEP-15-CDL of Crompton or any other make from the approved list of manufactures.
S&F in repair 15 Watt square recessed mounted down lighter with high luminous LED for indoor application, 230 Volts, 50 Hz , min 100 lm/watt with all accessories and connection to the electric circuit complete all as specified and as directed. Make: Cat part no. LSDEP-15-CDL of Crompton or any other make from the approved list of manufactures.
S&F in repair 15 Watt surface mounted round/square down lighter with high luminous LED for indoor application, 230 Volts, 50 Hz , min 100 lm/watt with all accessories and connection to the electric circuit complete all as specified and as directed. Make: Cat part no. LCRP-15-NW of Crompton or any other make from the approved list of manufactures.
S&F in repair 12 Watt square recessed mounted down lighter with high luminous LED for indoor application, 230 Volts, 50 Hz , min 100 lm/watt with all accessories and connection to the electric circuitcomplete all as specified and as directed. Make: Cat part no. LSDEP-12-CDL of Crompton or any other make from the approved list of manufactures.
S&F in repair 12 Watt recessed round down lighter with high luminous LED for indoor application, 230 Volts, 50 Hz , min 100 lm/watt with all accessories and connection to the electric circuit complete all as specified and as directed. Make: Cat part no. LCDEP-12-CDL of Crompton or any other make from the approved list of manufactures.
S&F in replacement celing light in Surface Trimeless Led light 18 Watt round 18 Watt 50 Hz,230 volts with all accessories and connection to the electric circuit complete all as specified and as directed. Make: Cat part no LCL18NR of Luker or any other make from the approved list of manufactures.
S&F in repair indoor Wall mounted Light 12 Watt, 140 volt to 265 volts,IP-20, 50 Hz ,100lu/w aluminium housing with all accessories and connection to the electric circuit complete all as specified and as directed. Make: Cat part no. LWL105 of luker or any other make from the approved list of manufactures.
S&F in repair bed side lamp 3 Watt 50 Hz,230 Volts, 3000 k with all accessories and connection to the electric circuit complete all as specified and as directed by Engineer-in-charge. Make: Cat part No-48042/30/31 of Philips or any other make from the approved list of manufactures.
S&F in repair 15 Watt LED bulb 230 Volts, 50 Hz with min 120 lumen/watt must match with the exiting lamp holder with necessary fixtures and fittings complete all as specified and directed.
S&F in repair 12 Watt LED bulb 230 Volts, 50 Hz with min 120 lumen/watt must match with the exiting lamp holder with necessary fixtures and fittings complete all as specified and directed.
S&F in repair 09 Watt LED bulb 230 Volts, 50 Hz with min 120 lumen/watt must match with the exiting lamp holder with necessary fixtures and fittings complete all as specified and directed.
S&F 9 W LED Lamp 850 lm 6500 k E27, Threaded/pin type, WW/WH Type complete all as specified and directed. Make: Havells Cat part No. LHLDDDHBIA5R009 or any other make from the approved list of manufactures.
S&F 7/5 W Lamp A60 Type E27 AMBER LED Filament lamp Threaded/Pin Type,WH/WW type complete all as specified and directed. Make: Havells Cat Part No. LHLDADHG3B8O7X5 or any other make from the approved list of manufactures.
S&F 3 W LED Bulb WH/WW type , Threaded/Pin Type complete all as specified and directed. Make: Luker Cat part No-LBGC03 or any other make from the approved list of manufactures.
S&F 4 W LED Bulb WH/WW type, Threaded/Pin Type complete all as specified and directed. Make: LukerLBFE2704 or any other make from the approved list of manufactures.
S&F flexible led strips of suitable wattage with uniform light distribution and long lasting adhesive for perfect cover lighting solution complete all as specified and directed.
S&F in repair ceiling light driver upto 6 Watt with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repair ceiling light driver 9 to 12 Watt with all accessories and connection to the electric circuit complete all as specified and directed.
S&F in repair ceiling light driver 15 to 18 Watt with all accessories and connection to the electric circuit complete all as specified and directed.
S&Fix in repair, lamp holder, PVC/Poly carbonate type with back plate suitable for batten fittings, complete all as specified and directed.
S&F in repair ceiling fans complete with blades,down rods,electronic regulator and accessories,230 V,1200 mm sweep,Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. Note: The old ceiling fan taken down shall be deposited to AGE (E/M) store yard.
S&F in repair exhaust fan, steel body AC single Phase 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. Note: The old ceiling fan taken down shall be deposited to AGE (E/M) store yard.
S&F in repair exhaust fan, steel body AC single Phase 230V of size 450 mm sweep with, blades, and frame and louvers complete all as specified and directed. Note: The old ceiling fan taken down shall be deposited to AGE (E/M) store yard.
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed. Note: The old ceiling fan taken down shall be deposited to AGE (E/M) store yard.
S&F in repair Wall mounted fans 300 mm sweep, 230 V, 50 Hz complete all as specified and directed. Note: The old ceiling fan taken down shall be deposited to AGE (E/M) store yard.
S&F in repair, capacitor for ceiling fans, 230 Volts, 2.5 MFD including necessary soldering complete all as specified and directed.
S&F in repair, capacitor for any type of exhaust fan/pedestal fan/air circulator fan 230 Volts including necessary soldering of capacity 4 MFD complete all as specified and directed.
S&F in repair Nickel plated mild steel clamps, Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size complete all as specified and directed.
S&F in repair Down rod, suitably threaded and holed, made out of 15 mm dia GI Tubes, duly painted 2' long, suitable for ceiling fans any type, any make,any size complete all as specified and directed.
S&F in repair Down rod, suitably threaded and holed, made out of 15 mm dia GI Tubes, duly painted 3' long, suitable for ceiling fans any type, any make,any size complete all as specified and directed.
S&F in repair Down rod, suitably threaded and holed, made out of 15 mm dia GI Tubes, duly painted 4' long, suitable for ceiling fans any type, any make,any size complete all as specified and directed.
S&F in repair fan canopy with tightening screw/check nut, made out of PVC,suitable for ceiling fans any type,any make, any size complete all as specified and directed.
S&F in rubber reel insulator,suitable for ceiling fnas any type,any make, any size complete all as specified and directed.
M&L for hanging hook for ceiling fan with nuts bolts and washer min thickness 5 mm complete all as specified and directed.
S&F in suitable shackle set with nuts,bolts and washer with necessary fittings and fixtures for ceiling fnas any type,any make, any size complete all as specified and directed.
Taking down unserviceable ceiling fan of 1200/1400 mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking/heating up the motor to achieve the proper insulation resistance and re-hanging /refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified and directed.
Ditto all as per item Ser No.128 above but exhaust fan of 450/300/250 mm sweep complete all as specified and directed.
Ditto all as per item Ser No.128 above but wall mounted fan of 400/450 mm sweep complete all as specified and directed.
Ditto all as per item Ser No.128 above but pedestal fans of 600/400 mm sweep complete all as specified and directed.
Ditto all as per item Ser No.128 above but industrial air circulator fans of any sizes complete all as specified and directed.
Supply and fix in repair exhaust motor for PVC type exhaust fan of size 200/250/300 mm sweep complete all as specified and directed.
Supply and fix in repair exhaust motor for steel body type exhaust fan of size 250/300/350mm sweep complete all as specified and directed.
M&L for checking of ceiling fans stability (like fan hooks,nuts,bolts,hanging rod, canopy,washer etc) exhaust fan stability, loose connection in distribution boars, MCBs in Qtrs complete all as specified and directed. NOTE: 1. The material incorporated for completion of work will be measured and paid separately under relevant item. 2.The contractor should prepare a register and enter office name with signature officer in charge and submitted to eng-in-charge.
Material & Labour including transportation of tools for rectification of urgent nature of electrical complaints like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc carrying out repairs such as tightening of loosen electric connections,nuts,bolts, screws of switches,sockets, switch boards,making joints and covering with PVC tape, minor repairs to ceiling fans/exhaust fans like replacement of capacitors,cleaning and oiling etc, as required m to make the electrical items/appliances fully functional at L&M Area during off hours (1700 hrs evening to 0900 hrs morning) on all working days all as specified and as directed by Engineer-in-charge NOTE:- (i) The material incorporated for completion of work will be measured and paid seperately under relevent item. (ii) The contractor should display contact number at complaint cell to register users complaint (iii)The recovery of rupees 1000 per complaints will be charged if contractor failed to attend the instipulated time period/. (iv) Number of complaints may vary day to day and shall be on required basis.
Material & Labour including transportation of tools for rectification of urgent nature of electrical complaints like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as changing of MCBs, small pieces of wires including connections etc carrying out repairs such as tightening of loosen electric connections,nuts,bolts, screws of switches,sockets, switch boards,making joints and covering with PVC tape, minor repairs to ceiling fans/exhaust fans like replacement of capacitors,cleaning and oiling etc, as required m to make the electrical items/appliances fully functional at L & M Area during off days incudling sunday and holiday days complete all as specified and as directed by Engineer-in-charge. NOTE:- (i) The material incorporated for completion of work will be measured and paid seperately under relevent item. (ii) The contractor should display contact number at complaint cell to register users complaint (iii)The recovery of rupees 1000 per complaints will be charged if contractor failed to attend the instipulated time period/. (iv) Number of complaints may vary day to day and shall be on required basis.
M&L for checking of ceiling fans stability (like fan hooks,nuts,bolts,hanging rod, canopy,washer etc) exhaust fan stability, loose connection in distribution boars,MCBs in Qtrs complete all as specified and as directed by Engineer-in-charge. NOTE: 1. The material incorporated for completion of work will be measured and paid separately under relevant item. 2.The contractor should prepare a register and enter qtr number with signature of occupant and submitted to eng-in-charge office.
S&F in repair AC single phase static energy meter of accuracy class 1.0 , rating 5 to 30 Amp , 250 Volts,50 Hz only KWHr compact meter with pilfer proof meter box with ceiling screw provision ( LCD Mni) complete all as specified and as directed.
S&F in repair AC three phase static energy meter of accuracy class 1.0 , 3 Phase , 415 Volts , with backlit LCD display of rating 10- 60 Amp , 250 Volts,50 Hz KWHr compact meter with pilfer proof meter box with ceiling screw provision (LCD Min complete all as specified and as directed.
M&L for checking of faulty/jumped energy meter (three phase/single phase) with fixing of new energy meter in series and after one week submitted meter reading report of both energy meter in eng-in-charge office complete all as specified and as directed.
M&L for rigid non metallic PVC medium grade conduit including junction boxes,tee,bends, elbows,reducers ,bell mouth tube ends,fixing accessorires such as couplers,lock nuts,saddle pipe hook etc for 25 mm dia. ISI marked complete all as specified and as directed.
S&F 4 mm dia galvanised iron or steel wire buried in ground fixed on walls and connected to main earth stirp including excavation and earth work, refilling etc. complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recces or chases or buried in ground or drawn in conduit/pipe or fixed to pole sor any other indicated situation for loop earthing etc. as required 25x4 mm galvanised iron strip complete all as specified and as directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recces or chases or buried in ground or drawn in conduit/pipe or fixed to pole sor any other indicated situation for loop earthing etc. as required 32x6 mm galvanised iron strip complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm dia as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and as directed by Engr-in-Charge. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to GI Strip 25X4 mm as earth up to 7.5 m distance and connected by means of bolts, nuts, checknuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 CM c/c , 20 mm bore medium grade watering pipe, water funnel, 40 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion complete all as specified and as directed by Engr-in-Charge. Note :- (i) The unit rate includes for protection pipe and earth lead upto 7.50 Mtr. (ii) Earth lead beyond 7.50 Mtr length shall be measured and paid separately.
S&F in repairs, on wall/ concealed on wall, 40mm dia. High pressure CPVC pipes SDR-13.5 & Plain CPVC SDR 11 fittings including all necessary fittings, solvents, complete all as specified and as directed.
S&F for in repairs, on wall/ concealed on wall, 25mm dia. High pressure CPVC pipes SDR-13.5 & Plain CPVC SDR 11 fittings including all necessary fittings, solvents, complete all as specified and as directed.
S&F in repairs, on wall/ concealed on wall, 20mm dia. High pressure CPVC pipes SDR-13.5 & Plain CPVC SDR 11 fittings including all necessary fittings, solvents, complete all as specified and as directed.
S&F in repairs, 15mm size Chromium Plated fancy type Bib Taps, quarter turn with flange and aerator, short body, cast copper alloy with crutch or butterfly handle, screwed for GI/ CPVC pipe, ccomplete all as specified and as directed. Make: Cera Cat. Part No. F2004151 or any other make from the approved list of manufactures.
S&F in repairs, 15mm size Chromium Plated fancy type Bib Taps, quarter turn with flange and aerator, long body, cast copper alloy with crutch or butterfly handle, screwed for GI/ CPVC pipe, complete all as specified and as directed. Make : CERA Cat. Part No. F2004152 or any other make from the approved list of manufactures.
S&F in repairs, 15mm size Chromium Plated cast copper alloy Bib Cock, short body with flange and nozzle for garden/ washing machine, complete all as specified and as directed. Make : CERA Model No. F 2003153 or any other make from the approved list of manufactures.
S&F in repairs, 15mm size Chromium Plated cast copper alloy Two way Bib Cock, quarter turn with flange and aerator, complete all as specified and as directed. Make : CERA Model No. F 2004211 or any other make from the approved list of manufactures.
S&F in repairs, 20mm size Chromium Plated cast copper alloy, fancy type, quarter turn Concealed Stop Cock, with CP cup and adjustable wall flange, complete all as specified and as directed. Make : CERA Model No. F 2002362 or any other make from the approved list of manufactures.
S&F in repairs, 15mm size Chromium Plated cast copper alloy Angle Valve, half turn with flange, for fixing with CPVC pipe, complete all as specified and as directed. Make : CERA Model No. F 2004201 or any other make from the approved list of manufactures.
S&F in repairs, 15mm size Swivel Overhead Shower (minimum weight 40 grams) of PTMT, any colour with shower arm (minimum weight 40 grams) 195mm long with bend of 45 degree with flange, fixing with CPVC Pipe, complete all as specified and as directed. Make : CERA Model No. F 7020104 or any other make from the approved list of manufactures.
S&F in repairs, 90mm dia. Hand Shower with 125 mm long arms, complete all as specified and as directed. Make : CERA Model No. F7030105 or any other make from the approved list of manufactures.
S&F in repairs, 450mm long, 15mm dia. PVC Connection with brass union on both sides to suit 15mm GI pipe, complete all as specified and as directed.
S&F in repairs, Health Faucet, ABS body with wall hook and one metre SS braided rubber hose pipe, complete all as per specified and directed. Make : CERA Model No. F 8030102 or any other make from the approved list of manufactures.
S&F in repairs, 15mm bore Chromium Plated fancy type, cast copper alloy Pillar Taps, quarter turn with aerator, with capstan heads, screwed down, high pressure with or without lettered 'Hot' or 'Cold', with long screwed shanks and fly nuts screwed for iron pipe and fixed, complete all as specified and as directed. Make : CERA Model No. 2006101 or equivalent in Prayag/ Hindware/ Jaguar
S&F in repairs, Wall Mixer (3-in-1) with arrangement of both Telephonic Shower and Over Head Shower, with 210mm long bend pipe, complete all as specified and as directed by the Engineer in Charge. Make : CERA Model No. F 2002403 or any other make from the approved list of manufactures.
S&F in repairs, Chromium Plated cast copper alloy Kitchen Sink Cock, quarter turn, wall mounted with swivel spout not less than 150 mm and wall flange complete all as specified and as directed. Make : Model No. F 2004251 of CERA or any other make from the approved list of manufactures.
M&L for cutting chases on walls, floors etc. not exceeding 10cm girth and making good the disturbed surface to match with the existing surface after removing the existing concealed pipe/ laying new pipe, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness, (below or above ground level) complete all as specified and directed.
M&L for Plain Cement Concrete 1:3:6 (Type C-2) using 40mm graded stone aggregate as in foundations, filling and mass concrete, complete all as specified and directed.
S&F 2000 litres capacity Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical, vertical with closed top), hoisted & fixed in position, complete all as specified and as directed.
S&F 1000 litres capacity Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical, vertical with closed top), hoisted & fixed in position, complete all as specified and as directed.
S&F 500 litres capacity Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical, vertical with closed top), hoisted & fixed in position, complete all as specified and as directed.
S&F in repairs, 40mm dia CPVC Ball Valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed.
S&F in repairs, 25mm dia CPVC Ball Valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed.
S&F in repairs, 20mm dia. CPVC Ball Valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed.
S&F in repairs, 40 mm dia synthetic (PVC) Float Valve, high pressure, with polythene ball of size 6" dia. and flynut, complete all as specified and directed.
S&F in repairs, 25 mm dia synthetic (PVC) Float Valve, high pressure, with polythene ball of size 6" dia. and flynut, complete all as specified and directed.
S&F in repairs, 20 mm dia synthetic (PVC) Float Valve, high pressure, with polythene ball of size 6" dia. and flynut, complete all as specified and directed.
Material, labour, transport and tools for rectification of urgent nature Water Supply complaints like Pipe breakdown, Air problem etc. at Naval Base as and when required (L & M Area) as and when required during all working days, Sundays/ Holidays/ Off hours of all working days, all as directed by Engineer in Charge. NOTE: (i) The material incorporated for completion of work will be measured and paid separately under relevant item. (ii) The contractor should display contact number at L & M Area to register users complaint. (iii)The recovery of Rs. 1000/- per complaint will be chargeable if contractor fails to attend complaint.
Taking down defective Geyser of 25/ 50 litres capacity from its existing position at any height duly disconnecting inlet/ outlet water connection and opening up geyser for checking defective parts and replacing the defective parts with new parts, including testing and commissioning the same after successful repairing, complete including refixing the same on its existing position and making connection inlet/ outlet water connection, complete all as specified and directed by Engineer in Charge. Note : The spares required for servicing the geyser shall be measured and paid separately under relevant item of the schedule as 'supply only'. The labour required for replacing spares shall include in this item.
Supply only Thermostat suitable for 25 litres and 50 litres capacity Geyser, any make/ type, complete all as specified and directed.
Supply only Heating Element 1.5 KW/ 2 KW, ISI marked for 25 litres and 50 litres capacity Geyser, any make/ type complete all as specified and directed.
Supply only Gasket for 25 litres and 50 litres capacity Geyser, complete all as specified and directed.
Supply only 12mm dia chromium plated pipe for 'Hot and Cold' water, of suitable length, with two brass adopter and connecting up, complete all as specified and directed.
Supply only Indicating Lamp suitable for 25 litres and 50 litres capacity Geyser, complete all as specified and directed by Engineer in Charge.
M&L for scrubbing, cleaning thoroughly, removing all scale and dirt, mud sediments, silts etc., from the internal surfaces of HDPE Storage Tanks below 500 Litres (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required, including writing the words "DATE OF CLEANING" in capital letters of suitable size on outside visible place of Water Tank with synthetic enamel paint (white) over black background, complete all as specified and as directed.
M&L for scrubbing, cleaning thoroughly, removing all scale and dirt, mud sediments, silts etc., from the internal surfaces of HDPE Storage Tanks below 1000 Litres (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required, including writing the words "DATE OF CLEANING" in capital letters of suitable size on outside visible place of Water Tank with synthetic enamel paint (white) over black background, complete all as specified and as directed.
M&L for scrubbing, cleaning thoroughly, removing all scale and dirt, mud sediments, silts etc., from the internal surfaces of HDPE Storage Tanks below 2000 Litres (bottom and wall) by using brushes, bleaching powder and other cleaning materials as required, including writing the words "DATE OF CLEANING" in capital letters of suitable size on outside visible place of Water Tank with synthetic enamel paint (white) over black background, complete all as specified and as directed.
S&F in replacement, Automatic Pressure Switch for 0.50HP to 2HP Booster Pump complete all as specified and as directed.
S&F in replacement, Surge Tank (Booster Tank) suitable for Booster Pump, complete all as specified and as directed.
S&F in replacement, Manifolder/ Connector Assembly suitable for 5 way Booster Pump, complete all as specified and as directed.
S&F in replacement, 25mm Non Return Valve for Booster Pump, complete all as specified and as directed.
S&F in replacement, Pressure Gauge 0-5 Kg/cm2 for Booster Pump, complete all as specified and as directed.
M&L for cleaning all types of taps including removing air from pipeline and some connected issues, checking water pressure in each bathroom and kitchen, complete all as specified and directed.
M&L for replacing all types of Spindle with washer of taps (Short body/ Long body tap, Angle Valve, Washing machine tap, Sink Cock etc.) including taking down, cleaning of tap and refixing after repair, complete all as specified and directed.
M&L for replacing all types of Spindle with washer of wall mixer taps (Short body/ Long body tap, Angle Valve, Washing machine tap, Sink Cock etc.) including taking down, cleaning of tap and refixing after repair, complete all as specified and directed.
S&F in replacement, rotate and lock type cover for 500 litres to 5000 litres capacity Over Head Water Tank (HDPE), complete all as specified and as directed.
S&F 25 litre capacity Electric Water Heater, Storage type, steel body with copper inner tank and heating element upto 2 KW, BEE 5 Star rated, with all accessories such as safety valve, thermostat, NRV, connection piece etc., complete all as specified and as directed.
S&F in repair centrifugal booster pump 1 HP, 0.75 KW, pressure setting range 2.0 to 4.5 kg/cm, tank capacity 24 ltrs, rust preventive aluminium die casted motor body, fitted with hot water seal, F-class insulation, suitable for hot water application complete all as specified and directed. Make: Cat part no -VB24F4A of V-guard or or any other make from the approved list of manufactures. Note :- Quoted rate shall Include provision of suitable type PVC canopy for protection of booster pump as per direction of Engineer-in-charge.
S&F in repair centrifugal booster pump 0.5 HP, 0.37 KW, pressure setting range 2.0 to 4.5 kg/cm, tank capacity 24 ltrs, rust preventive aluminium die casted motor body, fitted with hot water seal, F-class insulation, suitable for hot water application complete all as specified and directed. Make:- Cat part no. VB24.H3A of V-gaurd or any other make from the approved list of manufactures. Note :- Quoted rate shall Include provision of suitable type PVC canopy for protection of booster pump as per direction of Engineer-in-charge.
M/s.Rejoy Constructions (BID ID -3358880)
ELAN ENGINEERS (BID ID -3361193)
WELTRONENGINEERINGSERVICES (BID ID -3361135)
ZOOM ENTERPRISES (BID ID -3360368)
Green Ray Enterprises (BID ID -3360353)
CREATIVE BUILDERS (BID ID -3360821)
Super Constructions (BID ID -3360664)
Bell Builders (BID ID -3359764)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .