Headquarters, Commander Works Engineers, Pin-900129, C/o 56 APO
Provn of 2x incinerator and 1x toilet bathroom at gate No 1 of HQ CIF (R) and Provn of genr set shed for FRI of HQ CIF (R) and Provn of 2x RO water plant and exhaust fan at various location at HQ CIF (R) and Provn of 50 KVA voltage stabilizer
2019_MES_296725_2
CWE/PAL-26/2019-20
Open Tender
Civil Works - Others
Lump-sum
180 days
Palma
As per Tender documents
7 documents required · 7 mandatory
₹500
AGE (I) CIF R
₹34,790
Yes
26 Aug 2020
28 Jan 2020
17 Feb 2020
28 Jan 2020
15 Feb 2020
4 Feb 2020
Amount
Total Amount of Sch 'A' Part - I (Building Work)
Total amount of Sch 'A' Part-II (Incinerator Work)
Total Amount of Sch 'A' Part -III (Internal electrification Work )
Total Amount of Sch 'A' Part -IV (Internal water supply Work )
Total Amount of Sch 'A' Part -V (Plumbing work )
Total Amount of Sch 'A' Part -VI (Road/Path work )
Total Amount of Sch 'A' Part -VII (Sewage disposal work )
Total Amount of Sch 'A' Part -VIII (Area drainage )
Total Amount of Sch 'A' Part - IX (External water supply Work )
Total Amount of Sch 'A' Part -X ( External electric supply Work )
SCHEDULE 'A' PART- XI (Misc item of work) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under col of "Pre Priced rate" signifies this fact only.
(INTERNAL ELECTRIFICATION WORK)
Lamp holder insulated body with back plate for batten fittings and including LED lamp 9 watts White non dimmable B-22 holder base with polycarbonate body complet all as directed. Make C&S Cat Part No LTHPLED LAMP 9W/B22 or equal in Bajaj/ Philips /Havells as approved.
LED light fitting, single tube, 1 x 20 w LED, T8, 230 V (power factor not less than 0.90), box type, CRCA body, bipin holders connector blocks, etc. Complete with all accessories internally pre-wired, including LED lamp T8 20 W with aluminium heat shrink and connecting up with PVC insulated and sheathed, 1100 volts grade, flexible, multistranded 1.0 sqmm copper conductor three core cable complete all as directed.
Street light fitting 25 watt LED, IP-65 protection, single peice pressure die cast aluminium housing high grade powder coated finish with heat resistant toughened clear glass cover for lamp and control gear compartment with high voltage surge protection device upto 5 KV, prewired including 1.60m long 40mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of FI 40 x 6mm with bolts, nuts and washers and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable complete all as specified and directed. Make: CG Cat part No LSTP-25-CDL or equivalent in Philips/Bajaj.
Distribution board, IP-43 in sheet metal enclosure duly flushed in wall, when MCB to be used with 200 Amps rated copper bus bar confirming to relavent IS SPN 8 way complete all as specified.
Distribution board, IP-43 in sheet metal enclosure duly flushed in wall, when MCB to be used with 200 Amps rated copper bus bar confirming to relavent IS SPN 12 way complete all as specified.
MCB single pole 240 volts 6-32 Amps including providing thimble for out going cables 50Hz all as specified and directed.
MCB single pole & neutral, 240 volts 63 Amps, 10 Ka including providing thimble for out going cables 50Hz all as specified and directed.
(Sewage disposal) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under col of "Pre Priced rate" signifies this fact only.
On site conventional type LLDPE tank designated to carry sewage and sullage water, including excavation in any type of Soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 10 users.
(PROVN OF RO PLANT AND EXHAUST FAN)
Supply, installation testing and commissioning wall mounting type Reverse Osmosis Plant of Output capacity 25 liters per hour RO + UV water purification with ultraviolet disinfection with Arsenic, floride and chloride removal having 3 candels with micron filter having particulate filter porosity 10 micro with pressure vessel dual media filter electrically operated semi automatic with external cut off operating voltage 230 volts 50 HZ AC Supply including high pressure pump, raw water/chemical raw water/ chemical cleaning pump complete all as directed by Engr In Charge including following specifications:- (i) Minimum inlet pressure - 0.3 Kg/ sqcm (ii) Maximum inlet pressure - 3.5 Kg/sqcm (iii) Maximum inlete temparature - 35 degree centigrade (iv) Total disolved solids removal persentage from RO Membrane - 90% Make :- EMPERIA/Aquashakti water solutions/Aquaguard water solutions.
Supply and fix tube medium grade, galvanised with all fittings and fixed complete to wall and ceiling or laid in floors of size 25mm dia laid in trenches.
M&L cutting of existing GI tube 40mm bore for making new connection inserting unequal Tee 40x40x25mm bore complete all as specified.
Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of size 25mm dia.
Supply, fixing and hoisting in position Rotational moulded polyethylene water storage tank,1000 liters capacity, multi layer construction (cylindrical vertical with closed top), hoisted & fixed in position complete all as specified and as directed.
S&F Ball valves, high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball, screwed for iron pipe of 25mm bore of having weight not less than 455 gms complete all as specified and as directed.
M&L PCC (1:4:8) type D2 using 40mm graded stone aggregates as in foundation filling and mass concrete.
M&L PCC (1:3:6) type C1 using 20mm graded stone aggregate as in coping and other similar bends including weathering, slightly rounded or chamfered angles and throating as directed including necessary use and waste form work.
M&L walling of randum rubble, uncoursed, well bonded, bedded and solidly hearted, built in 1:8 cement mortor.
Rendering 10mm thick on concrete surfaces in CM (1:4) finishes even & smooth without using extra cement.
Supply and fixing heavy duty exhaust fan including louvers / shutters 450mm sweep 1400 RPM with mounting accessories model TURBO SP of Make Havells or equivalent in Bajaj or CG single phase 230 volt 50 HZ Ac supply including connecting electrically by using 3 core flexible wire complete all as directed by Engr In Charge. Note :- The rate quoted by the contractor shall include the rate for making holes for mounting of exhaust fan in any type of walls and making good the disturbed space.
M&L Point wiring complete with 1.5 Sqmm single core multi stranded copper conductor cable PVC insulated unsheathed cable 1100 volt grade enclosed and including PVC casing and capping with fittings and accessories fixed to walls/ceiling by means of PVC rowl plugs fasteners with cadmium plated screws all as per IS including hard wood board and 3mm thick laminated sheet top covers including 1.5 Sqmm copper PVC insulated unsheathed continuous earth wire and connected to common earth dolly for one fan point.
Supply and Fixing switch piano type 6 Amps one way 230 volts AC complete all as specified and as directed
Supply and fixing ceiling rose 65X50 mm two to three terminals complete all as specified.
(PROVN OF 50 KVA VOLTAGE STABILIZER)
Supply, install, testing and commissioning Voltage stabilizer for automatic operation three phase, naturally oil cooled, indoor type & designed for input variation between 250 Volts to 480 Volts with output voltage stabilized at 415 volts with accuracy +/- 2.5% and speed of correction 20 volts per second phase to phase and capacity 50 KVA with and including 1st filling of transformer oil and having following specifications:- (i) Input voltage 250V - 480 V (ii) Output voltage stabilized - 415 V +/- 1% (iii) Rated frequency 50 HZ (iv) No distoration in wave form (v) Response time not to exceed 10 mille seconds (vi) Rate of correction 8 volt/Sec for single phase and 20V/Sec for phase to phase (vii) Efficiancy more than 95% (viii) Digital display voltmeter, Ammeter (ix) Capacity 50 KVA (x) PROTECTIONS:- (i) Over load/short circuit protection (ii) High/low voltage cut off (iii) Bypass arrengement in case of emergency (iv) Single phase sequence change operation Make :- Powerware/Andrew Yule/M/s Vintek Electronics (Volina)/Sinetrac/Aplab.
Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 35 sqmm 3.5 core with all fixing & connecting accessories. Make: Havell’s / Polycab / Finolex)
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4mm thick for earthing lead fixed by means of nuts,bolt,washers etc.of copper / brass connected to earth test point complete all as specified in electrical plate NO 5 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,GI water pipe with 20mm dia.funnel &wire mesh PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil.
Removal excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point in soils.
Excavating in post holes not exceeding 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm in soft/ loose soil.
Cement concrete in foundations, and mass concrete type D2 1:4:8 using 40mm graded stone aggregate.
Cement concrete in foundations, and mass concrete type C1 1:3:6 using 20mm graded stone aggregate.
Cement concrete in posts type B2 1:2:4 using 40mm graded stone aggregate.
Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement plaster 1:3.
Galvonised, corrogated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs walls etc. with grade grade of zinc coating 275 of thickness 0.63mm
MS ERW pipes of size 50mm.
Sub total of Schedule 'A' Part-XI
MEHTA OM PARKASH
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .