| 1 | L1₹30.2 LAccepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.2 L+₹3.2 L (10.4%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L2 | Rejected-Finance L2 | |
| 3 | L3₹43.6 L+₹12.6 L (40.6%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L3 | Rejected-Finance L3 | |
| 4 | L4₹44.4 L+₹13.4 L (43.4%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹47.1 L+₹16.1 L (52.0%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
24 Oct 2019, 6:00 pmClosed
Lt Col Amit Bhat
Garrison Engineer (AF) No.1 Military Engineer Service Air Force Station No.1 Jamnagar 361 003
COMPREHENSIVE MAINTENANCE OF DG SETS , AMF PANELS AND ITS CONNECTED ITEMS AT AF STN JAMNAGAR UNDER AGE E/M (ELECT) OF GE (AF) JAMNAGAR NO. 1
2019_MES_284413_1
8698/E8
Open Tender
Miscellaneous Works
Item Rate
365 days
JAMNAGAR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF JAMNAGAR
₹76,000
Yes
1 Jan 2020
24 Sept 2019
25 Oct 2019
24 Sept 2019
24 Oct 2019
9 Oct 2019
Amount
Note for all items of this BOQ:- (i) Contractor’s special attention is invited that whenever defect will occur in the DG set the same shall be intimated to contractor / their authorized supervisor through telephone / email by the Engineer-In-Charge. The defects will be attended by the contractor within 24 hours from the time of intimation. In case of major fault in the DG set which cannot be rectified within 24 hours, contractor will submit documentary evidence from authorized service centre of DG set that within what period defect will be rectified........
........... Soon after the work order is placed, contractor will intimate the telephone nos of himself & their authorized supervisors & email id for communicating the defects of DG Set. Engineer-In-Charge will maintain the necessary records, indicating the location & capacity of DG SET, nature of defect in the DG set, and time & date of intimation of defect to contractor / their supervisor.
(ii) In case contractor fails to rectify the defect within 24 hours for minor defect or within time limit intimated by the authorized service centre of DG set for major fault, a penalty will be imposed to contractor at the rate of Rs 5000.00 (Rupees five thousand) per day or part thereof or maximum up to Rs 25,000.00 (twenty five thousend). This amount will be deducted from the RAR / FB of the contract.
M&L for repairing / servicing of DG set of capacity 10 to 15 KVA (Make : Kirloskar), silent type DG set, by dismantling of sub assembly like injectors, governor, self starter, dynamo engine wiring, terminal contacts and safety controls, exhaust system, fuel pump etc including arresting leakage of oil sump and replacement of defective spare parts, such as oil filter, diesel filter, air filter, gaskets miscellaneous nut bolt etc and reassembling the sub assembly after carrying out necessary repairs including testing of DG set for smooth running on proper load to the satisfaction of Engineer-In-Charge all as directed by Engr-in-Charge.
Note : (i) Quoted rates shall be deemed to include cost of oil filter, diesel filter, air filter, gaskets miscellaneous nut bolt etc however other defective spare parts, will be measured and paid separately under relevant items of BOQ as supply and fix in repair only.
(ii) All spare parts shall be as per the recommendation of original equipment manufacturer. (iii) Repairs to radiator / alternator will be measured and paid for separately under relevant items of BOQ. (iv) Engine oil will be measured & paid separately as supply only under respective item of BOQ.
(v) Servicing of DG Set shall be carried out through the authorised service center of the original equipment manufacturer. (vi) Servicing of DG Set shall be carried out two times during contract period at the interval of 6 months and shall be measured & paid two times per DG set. (vi) Servicing certificate provided by contractor and servicing is valid for one year.
All as per item No 1 above but for 20 to 30 KVA capacity DG set (Make : Kirloskar/ cummins).
All as per item No 1 above but for 50 to 63 KVA capacity DG set (Make : Kirloskar).
All as per item No 1 above but for 70 KVA to 82.5 KVA capacity DG set (Make : Kirloskar/Cummins).
All as per item No 1 above but for 100 to 125 KVA capacity DG set (Make : Kirloskar/Ashok Leyland/Greaves Cotton).
All as per item No 1 above but for 160 to 200 KVA capacity DG set (Make : Kirloskar/Greaves/CG).
All as per item No 1 above but for 320 to 400 KVA capacity DG set (Make : Kirloskar/Crompton Greaves).
Supply & fix in repair fuel pipe (Hydraulic) feed pump to MICO filter suitable for DG set cap 10 to 15 KVA. Make: Kirloskar
All as per item No 8 above but for 20 KVA to 30 KVA capacity DG set (Make : Kirloskar / Cummins).
All as per item No 8 above but for 50 to 63 KVA capacity DG set (Make : Kirloskar).
All as per item No 8 above but for 70 KVA to 82.5 KVA capacity DG set (Make : Kirloskar/Cummins).
All as per item No 8 above but for 100 to 125 KVA capacity DG set (Make : Kirloskar / Ashok Leyland / Greaves Cotton).
All as per item No 8 above but for 160 to 200 KVA capacity DG set (Make : Kirloskar / Greaves / CG).
All as per item No 8 above but for 320 to 400 KVA capacity DG set (Make : Kirloskar/Greaves).
Supply & fix in repair Air inlet M'Fold (Finish) suitable for DG set cap 10 to 15 KVA Make: Kirloskar
All as per item No 15 above but for 20 KVA to 30 KVA capacity DG set (Make : Kirloskar / Cummins).
All as per item No 15 above but for 50 to 63 KVA capacity DG set (Make : Kirloskar).
All as per item No 15 above but for 70 KVA to 82.5 KVA capacity DG set (Make : Kirloskar / Cummins).
All as per item No 15 above but for 100 to 125 KVA capacity DG set (Make : Kirloskar / Ashok Leyland / Greaves Cotton).
All as per item No 15 above but for 160 to 200 KVA capacity DG set (Make : Kirloskar / Greaves / CG).
All as per item No 15 above but for 320 to 400 KVA capacity DG set (Make : Kirloskar / Crompton Greaves).
Supply & fix in repair gear pump, DM 20 / DA 20, RR with STL ext gear & rel valve suitable for DG set cap 10 to 15 KVA (Make : Kirloskar).
All as per item No 22 above but for 20 KVA to 30 KVA capacity DG set (Make : Kirloskar/Cummins).
All as per item No 22 above but for 50 to 63 KVA capacity DG set (Make : Kirloskar).
All as per item No 22 above but for 70 KVA to 82.5 KVA capacity DG set (Make : Kirloskar/Cummins).
All as per item No 22 above but for 100 to 125 KVA capacity DG set (Make : Kirloskar / Ashok Leyland / Greaves Cotton).
All as per item No 22 above but for 160 to 200 KVA capacity DG set (Make : Kirloskar/Greaves/CG).
All as per item No 22 above but for 320 to 400 KVA capacity DG set (Make : Kirloskar/Crompton Greaves).
Supply & fix in repair flywheel assembly, ES, SR- S/F SAE 3 HSG suitable for DG set cap 10 to 15 KVA (Make : Kirloskar).
All as per item No 29 above but for 20 KVA to 30 KVA capacity DG set (Make : Kirloskar / Cummins).
All as per item No 29 above but for 50 to 63 KVA capacity DG set (Make : Kirloskar).
All as per item No 29 above but for 70 KVA to 82.5 KVA capacity DG set (Make : Kirloskar / Cummins).
All as per item No 29 above but for 100 to 125 KVA capacity DG set (Make : Kirloskar / Ashok Leyland / Greaves Cotton).
All as per item No 29 above but for 160 to 200 KVA capacity DG set (Make : Kirloskar / Greaves CG).
Supply only coolant in 25 Litres Pack in CAN for top up of Radiator of DG sets of various capacity all as specified
Supply and fix in repair oil pressure gauge all as specified Make:- Kirloskar / Cummins / Greaves
Note for make of spare parts of DG Set:- Make of spare parts of DG Set shall be as mention against each of items of this BOQ, if the same is not available / suitable for other make of DG set the same shall be as recommended by the original equipment manufacturer.
Supply and fix in repair lead acid battery 12 V 180 AH with initial charging, fixing & connecting, at site, taking out old battery and deposit in the store yard of AGE E/M all as directed by Engr-in-Charge. Make :- Exide / TATA /Amron / Standard Furukava
Supply and fix in repair lead acid battery 12 V 150 AH with initial charging, fixing & connecting, at site, taking out old battery and deposit in the store yard of AGE E/M all as directed by Engr-in-Charge. Make : Exide / TATA / Amron / Standard Furukava
Supply and fix in repair lead acid battery 12 V 90 AH with initial charging, fixing & connecting, at site, taking out old battery and deposit in the store yard of AGE E/M all as directed by Engr-in-Charge. Make:- Exide / TATA / Amron / Standard Furukava
Supply & fix in repair battery lead of PVC insulated single core multistrandard copper conductor of size 35 Sqmm cable, with lugs fixed in position as directed complete all as specified
M&L for distilled water (electrolyte ) to be filled in lead acid batteries all as directed by Engr-In-Charge
Supply and fix in repair ignition switch with key for DG sets of any capacities fixed in position & connecting complete all as directed by Engr-in-Charge.
Supply and fix in repair rubber hose pipe with connecting fitting & fixture for radiator suitable for 400/320 / 200 / 160 KVA DG Set. Make:- Kirloskar / Cummins / Greaves
Supply and fix in repair rubber hose pipe with connecting fitting & fixture suitable for 125/100/ 82.5 / 75 / 63/50 KVA DG Set Make:- Kirloskar / Cummins / Greaves
Supply and fix in repair rubber hose pipe with connecting fitting & fixture suitable for 10 / 15 / 20 / 25 / 30 KVA DG Set of Make:- Kirloskar / Cummins / Greaves
Supply and fix in repair coupling bushes suitable for 200 KVA to 400 capacity DG Set, fixed in position including proper alignment of Engine and Alternator suitable Make:- Kirloskar / Cummins / Greaves
Supply and fix in repair coupling bushes suitable for 63 KVA to 160 capacity DG Set, fixed in position including proper alignment of Engine and Alternator suitable Make:- Kirloskar / Cummins / Greaves
M&L for taking out self starter of 12 / 24 volts DC from DG set, servicing of starter including replacement of clutch plate, moving control pinion, spring etc, fixed in same position complete all as specified & directed by Engineer-in Charge. suitable Make:- Kirloskar / Cummins / Greaves
Note :- The following works is included in the unit rate of contract quoted by contractor:-
(i) Rewinding of penion assembly with suitable size of copper wire , varnishing and heating etc.
(ii) Replacement of worn out field coil
(iii) Replacement of clutch plate assembly
(iv) Replacement of solenoid switch
M&L for dismantling, taking out choke up radiator assembly, of 10 to 30 KVA DG Set, servicing,de-scaling, cleaning of fan and cooling coil fins including soldering / brazing at the leakage point re-fixing radiator assembly after repair complete all as specified and as directed.
M&L for dismantling, taking out choke up radiator assembly, of 50 to 160 KVA DG Set, servicing,de-scaling, cleaning of fan and cooling coil fins including soldering / brazing at the leakage point re-fixing radiator assembly after repair complete all as specified and as directed.
M&L for dismantling, taking out choke up radiator assembly, of 200 to 400 KVA DG Set, servicing de-scaling, cleaning of fan and cooling coil fins including soldering / brazing at the leakage point re-fixing radiator assembly after repair complete all as specified and as directed.
Supply and fix in repair self starter 12 V with solenoid switch assembly complete fixed to DG set of any capacity complete all as specified & directed by the engineer-in-Charge Make:- Auto lek / TVS Lucas or equivalent make approved by the GE
Supply and fix in repair self starter 24 V with solenoid switch assembly complete fixed to DG set of any capacity complete all as specified & directed by the engineer-in-Charge Make:- Auto lek / TVS Lucas or equivalent make approved by the GE
Supply and fix in repair flexible diesel pipe with banjo bolts and washers suitable for 10/15/20/30/50/63 / 75 / 81.5 / 100 KVA DG sets complete all as specified & directed by the Engineer-in-Charge suitable for Make:- Kirloskar / Cummins / Greaves
Supply and fix in repair flexible diesel pipe with banjo bolts and washers suitable for 125 / 200 / 320/400 KVA DG sets complete all as specified & directed by the Engineer-in-Charge. Suitable for Make:- Kirloskar / Cummins / Greaves
Supply & fix in repair electronic type automatic voltage regulator (AVR) of 100 V, 8 Amps suitable for DG Set of capacity up to 100 KVA including necessary terminals' sleeves etc. complete all as specified & directed by the Engineer-in-Charge. suitable Make:- Kirloskar / Cummins / Greaves
Supply & fix in repair electronic type automatic voltage regulator (AVR) of 50 V, 16 Amps suitable for DG Set of capacity 125 to 400 KVA including necessary terminals' sleeves etc. complete all as specified & directed by the Engineer-in-Charge suitable for Make:- Kirloskar / Cummins / Greaves
Supply & fix in repair solenoid coil of self starter of 24V capacity of any capacity DG sets taking out of self and transportation to workshop is deemed to be included quoted rate all as directed. suitable for Make:- Kirloskar / Cummins / Greaves
Supply & fix in repair solenoid coil of self starter of 12V capacity of any capacity DG sets taking out of self and transportation to workshop is deemed to be included quoted rate all as directed suitable for Make:- Kirloskar / Cummins / Greaves
M&L for removing and taking out fuel injection pump (FIP) assembly from DG set of any capacity for repair and calibration of fuel pump with injector nozzles tips including replacement unserviceable parts such as shut down valve (stop solenoid assembly) spring, piston nozzles plunger etc complete all as specified & directed by the Engineer-in-Charge
Supply only engine oil 20 W 40 for DG set for top up and replacing engine oil complete all as specified. Make :- Servo / HP / BP
Supply & fix second class hardwood plank of size 300 mm x 450 mm x 40 mm thick duly treated & varnished complete suitable for fixing under the battery of DG sets of different capacities, complete all as specified and directed
M&L for repair in Right / Left hand lock with catcher for acoustic enclosure (canopy) of any capacity DG sets all as specified & directed.
M&L for Dial type mechanical fuel level indicator for any capacity DG set complete all as specified & directed.
S&F in repair 3 Pole 400 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 400) or equivalent of make siemens / ABB
S&F in repair 3 Pole 265 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 265) or equivalent of make siemens/ABB
S&F in repair 3 Pole 225 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge Make L&T (Type MNX 225) or equivalent of make siemens/ABB
S&F in repair 3 Pole 185 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 185) or equivalent of make siemens / ABB
S&F in repair 3 Pole 140 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 140) or equivalent of make siemens / ABB
S&F in repair 3 Pole 95 Amp power contactor, AC 3 rating, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge. Make L&T (Type MNX 95) or equivalent of make siemens/ABB
S&F in repair MCCB 400 Amps, 4 pole, breaking capacity 36/35 kA with thermal Magnetic release range 320 Amps to 400 Amps, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair MCCB 250 Amps, 4 pole, breaking capacity 36/35 kA with thermal Magnetic release range 200 Amps to 250 Amps, fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair MCCB 160 Amps, 4 pole, breaking capacity 25 kA, fixed type fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair MCCB 100 Amps, 4 pole, breaking capacity 25 kA, fixed type fixed in existing panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair indicating lamp LED type, size 22.5 mm voltage 240 V AC. fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
S&F in repair push button with element for PB1 - Engine start / PB2 - Engine stop / PB3 - DG contactor ON / PB4 - DG contactor OFF / PB5 - Mains contactor ON / PB6 - Mains contactor OFF, fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
S&F in repair Aux control relay with socket 3 C/O 12 V DC, 5 A fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
S&F in repair amps meter digital type 0-400 Amps of size 96 mm x 96 mm, fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
S&F in repair C T ratio 100 A Class of accuracy 1, VA 15, ring type fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair Digital type DC Voltmeter, 0 to 30 V DC, size 96 mm x 96 mm fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
S&F in repair Digital type DC Ammeter, 0 to 20 ADC, size 96 mm x 96 mm fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
S&F in repair Electronic type Hooter, supply voltage 12 V, DC flush mounted, suitable for DG set, fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
Supply and fix in repair MCB’s single pole 6-32 Amps, 415 volts with ‘C’ curve, fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
Supply and fix in repair Aux supply 12 V DC, voltage sensing relay 415 V AC fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge. Make:- BCH / C&S / Havells / Simens / L&T
M&L for cutting & removing the rusted portion of the canopy (acoustic enclosure) of DG set with inner side iron jali, and supply & welding 3 mm thick MS sheet including welding painting with two coat of synthetic enamel paint of existing colour over a coat of red oxide primer to match with the existing colour complete all as directed.
Supply and fix in repair electronic type auto battery charger for AMF of any capacity DG sets 440 / 12 V output voltage complete all as directed.
S & F in repair electronic controller for AMF panel of capacity 63 to 100 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel all as directed. Make : Wood Word / Deep sea Electronic
S & F in repair electronic controller for AMF panel of capacity 125 to 160 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel all as directed. Make : Wood Word / Deep sea Electronic
S & F in repair electronic controller for AMF panel of capacity 200 to 400 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel all as directed. Make : Wood Word / Deep sea Electronic
Material and labour for renewal earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel strip of size 32 mm x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 40 mm bore galvanised iron light grade for earth strip protection...........
……..including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:- Quoted rates shall be deemed to include for earth wire with protection pipe up to 7.5 M length.
Dismantling of alternator assembly complete from DG set of capacity from 10KVA to 400 KVA and removing the burnt out copper winding cleaning of limb thoroughly and rewinding the same with supper enameled copper winding wire of the same gauge and turn with proper class of insulation impregnated & baking, assembling and testing complete all as specified & directed by Engineer-in-Charge.
Supply & fix in repair water pump pulley SPA section (120 PCD) suitable for DG set 10 KVA to 75 KVA Make: Kirloskar
Supply & fix in repair water pump pulley SPA section (120 PCD) suitable for DG set 82.5 KVA to 200 KVA Make: Kirloskar /Greaves/Cummins
Supply & fix in repair water pump pulley SPA section (120 PCD) suitable for DG set 320 KVA to 400 KVA Make: Kirloskar / Greaves
Supply & fix in repair water pump assembly suitable for DG set 10 KVA to 75 KVA Make: Kirloskar
Supply & fix in repair water pump assembly suitable for DG set 82.5 KVA to 200 KVA Make: Kirloskar / Greaves / Cummins
Supply & fix in repair water pump assembly suitable for DG set 320 KVA to 400 KVA. Make: Kirloskar / Greaves
Supply & fix in repair lubricant oil pump assembly suitable for DG set 10 KVA to 75 KVA Make: Kirloskar
Supply & fix in repair lubricant oil pump assembly suitable for DG set 82.5 KVA to 200 KVA Make: Kirloskar / Greaves / Cummins
Supply & fix in repair lubricant oil pump assembly suitable for DG set 320 KVA to 400 KVA Make: Kirloskar /Greaves
Supply & fix in repair Injector suitable for FIP DG set uptp 100 KVA Make: Kirloskar / Greaves / cummins
Supply & fix in repair Injector suitable for FIP DG set above 100 and upto 200 KVA. Make: Kirloskar / Greaves / Ashok Leyland / CG
Supply & fix in repair Injector suitable for FIP DG set above 200 KVA and upto 400 KVA Make: Kirloskar / Greaves
Supply & fix in repair oil seal as per existing shape and size CR make Make: Kirloskar / Greaves / Cummins
Supply & fix in repair silencer assembly complete suitable for DG set cap 10 to 35 KVA (Make : Kirloskar / Cummins).
Supply & fix in repair turbocharger assembly suitable for DG up to 100 KVA Make: Kirloskar / Greaves / Cummins
Supply & fix in repair turbocharger assembly suitable for DG above 100 and up to 200 KVA Make: Kirloskar / Greaves / Cummins
Supply & fix in repair turbocharger assembly suitable for DG above 320 to 400 KVA Make: Kirloskar / Greaves / Cummins
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 15 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old AMF panel all as specified and directed & Consisting of the following equipment
(a) 4 Pole 32 Amp power Contractor, AC 3 duty, coil voltage 230 VAC - 02 Nos
(b) MCCB, 32 Amps 4 pole 16 KA 50 Hz - 02 Nos
(c) Panel should be Internally prewired with suitable size of copper conductor PVC insulated cable with colour coding - 01 job
(e) AC ammeter digital type 0- 100 A inbuilt. - 01 No
(g) C T ratio 60 A Class of accuracy 1, VA 15 resigend cast, ring type. - 06 Nos
(h) Indicating lamp LED type , Size 22.5 mm voltage 240 VAC. DG ON indicating lamp , Mains MCCB ON indication lamp , SC Supply ON indicating lamp. - 06 Nos
(j) push button with element PB1 - Engine start PB2 - Engine stop PB3 - DG contactor ON PB4 - DG contactor OFF PB5 - Mains contactor ON PB6 - Mains contactor OFF
(k) Aux control relay with socket 3 C/O 12 VDC, 5 A - 04 Nos
(m) Digital type DC Voltmeter, 0 to 30 VDC - 01 Nos
(n) Electronic type Hooter, supply voltage 12 V DC 96 Sqmm flush mounted - 01 No
(o) Miniature circuit breaker , 1 pole 6 Amps with over load & short circuit protection , short circuit strength 10 kA - 06 Nos .
(p) Miniature circuit breaker , 1 pole 10 Amps with over load & short circuit protection , short circuit strength 10 KA. - 02 Nos
(q) Neutral link rated current 15 A -01 No
(r) Aux supply 12 V DC , voltage sensing relay 415 VAC. - 02 Nos
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 10 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old AMF panel all as specified and directed & Consisting of the following equipment
(a) 4 Pole 25 Amp power Contractor, AC 3 duty, coil voltage 230 VAC - 02 Nos
(b) MCB, TPN, 25 Amps 4 pole 16 KA 50 Hz - 02 Nos
(c) Panel should be Internally prewired with suitable size of copper conductor PVC insulated cable with colour coding - 01 job
(e) AC ammeter digital type 0- 100 A inbuilt. - 01 No
(g) C T ratio 20 A Class of accuracy 1, VA 15 resigend cast, ring type. - 06 Nos
(h) Indicating lamp LED type , Size 22.5 mm voltage 240 VAC. DG ON indicating lamp , Mains MCCB ON indication lamp , SC Supply ON indicating lamp. - 06 Nos
(j) push button with element PB1 - Engine start PB2 - Engine stop PB3 - DG contactor ON PB4 - DG contactor OFF PB5 - Mains contactor ON PB6 - Mains contactor OFF
(k) Aux control relay with socket 3 C/O 12 VDC, 5 A - 04 Nos
(m) Digital type DC Voltmeter, 0 to 30 VDC - 01 Nos
(n) Electronic type Hooter, supply voltage 12 V DC 96 Sqmm flush mounted - 01 No
(o) Miniature circuit breaker , 1 pole 6 Amps with over load & short circuit protection , short circuit strength 10 kA - 06 Nos .
(p) Miniature circuit breaker , 1 pole 10 Amps with over load & short circuit protection , short circuit strength 10 KA. - 02 Nos
(q) Neutral link rated current 15 A -01 No
(r) Aux supply 12 V DC , voltage sensing relay 415 VAC. - 02 Nos
Supply & fix V belt complete of capacity 100 KVA to 200 KVA DG Set complete as specified & directed
S & F Oil filter complete of DG set of any capacity as specified & directed
Excavating in post holes in soft / loose soil (or similar holes) each n.exc 0.5 cum, getting out, returning, refilling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in soft / loose soil removing surplus soil to a distance n exc 50 m complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C2, using 40 mm graded stone aggregate, as in foundation / mass concrete complete all as directed.
S&F Steel work in trusses fabricated with rectangular / Square hollow section, including special shaped, washers etc including cutting welding, bending in shape etc using tube of YST 310 grade confirming to IS-4923 complete all as specified & directed.
S&F 0.50 mm thick Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall or roof, fixed with self tapping / drilled screws complete as specified and as directed by Engineer-in-charge
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying two coat of Synthetic enamel paint over a coat of red oxide, primer complete all as specified.
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 160 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old AMF panel all as specified and directed & Consisting of the following equipment
(a) 4 Pole 250 Amp power Contractor, AC 3 duty, coil voltage 230 VAC - 02 Nos
(b) MCCB, 200 Amps 4 pole 16 KA 50 Hz - 02 Nos
(c) Panel should be Internally prewired with suitable size of copper conductor PVC insulated cable with colour coding - 01 job
(e) AC ammeter digital type 0- 100 A inbuilt. - 01 No
(g) C T ratio 20 A Class of accuracy 1, VA 15 resigend cast, ring type. - 06 Nos
(h) Indicating lamp LED type , Size 22.5 mm voltage 240 VAC. DG ON indicating lamp , Mains MCCB ON indication lamp , SC Supply ON indicating lamp. - 06 Nos
(j) push button with element PB1 - Engine start PB2 - Engine stop PB3 - DG contactor ON PB4 - DG contactor OFF PB5 - Mains contactor ON PB6 - Mains contactor OFF
(k) Aux control relay with socket 3 C/O 12 VDC, 5 A - 04 Nos
(m) Digital type DC Voltmeter, 0 to 30 VDC - 01 Nos
(n) Electronic type Hooter, supply voltage 12 V DC 96 Sqmm flush mounted - 01 No
(o) Miniature circuit breaker , 1 pole 6 Amps with over load & short circuit protection , short circuit strength 10 kA - 06 Nos .
(p) Miniature circuit breaker , 1 pole 10 Amps with over load & short circuit protection , short circuit strength 10 KA. - 02 Nos
(q) Neutral link rated current 15 A -01 No
(r) Aux supply 12 V DC , voltage sensing relay 415 VAC. - 02 Nos
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 25 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old AMF panel all as specified and directed & Consisting of the following equipment
(a) 4 Pole 32 Amp power Contractor, AC 3 duty, coil voltage 230 VAC - 02 Nos
(b) MCB, TPN, 32 Amps 4 pole 16 KA 50 Hz - 02 Nos
(c) Panel should be Internally prewired with suitable size of copper conductor PVC insulated cable with colour coding - 01 job
(e) AC ammeter digital type 0- 100 A inbuilt. - 01 No
(g) C T ratio 20 A Class of accuracy 1, VA 15 resigend cast, ring type. - 06 Nos
(h) Indicating lamp LED type , Size 22.5 mm voltage 240 VAC. DG ON indicating lamp , Mains MCCB ON indication lamp , SC Supply ON indicating lamp. - 06 Nos
(j) push button with element PB1 - Engine start PB2 - Engine stop PB3 - DG contactor ON PB4 - DG contactor OFF PB5 - Mains contactor ON PB6 - Mains contactor OFF
(k) Aux control relay with socket 3 C/O 12 VDC, 5 A - 04 Nos
(m) Digital type DC Voltmeter, 0 to 30 VDC - 01 Nos
(n) Electronic type Hooter, supply voltage 12 V DC 96 Sqmm flush mounted - 01 No
(o) Miniature circuit breaker , 1 pole 6 Amps with over load & short circuit protection , short circuit strength 10 kA - 06 Nos .
(p) Miniature circuit breaker , 1 pole 10 Amps with over load & short circuit protection , short circuit strength 10 KA. - 02 Nos
(q) Neutral link rated current 15 A -01 No
(r) Aux supply 12 V DC , voltage sensing relay 415 VAC. - 02 Nos
Material and Labour for cleaning of dust particles from inside the AMF Panel by air blowers, tightening of loose connections, filling of gaps with sealants, removing of vegetation, surface dressing surrounding the panel, welding of damaged panel doors, fixing of hinges, providing locking arrangements, applying one coat of primer, painting of panel with two coats synthetic enamel paint of existing colour complete including providing lock all as specified and directed by Engr-in-charge.
M&L for taking out fuel tank from 200 KVA DG Set, welding / brazing at all leakage joint to make leakproof & reinstalled as specified & directed by Engg-in-charge.
Supply & fix in repair AMF controller of 400 KVA DG Set of existing make complete (officer Mess) all as specified and directed by Engr-in-charge. Make: As recommended by OEM and approved by the GE.
Supply & fix in repair AMF controller of 160 KVA DG Set of existing make complete (Power House) all as specified and directed by Engr-in-charge. Make: As recommended by OEM and approved by the GE.
M/s SK Traders
ALBA AC AND REF SERVICES
Vijay Construction Co
Chamunda Kruparefrigeration
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .