Chief Engineer (Project and R&C)
Site Survey, Designing, Engineering, Procurement, Supply, Loading, Transportation, Unloading, Insurance, Delivery at Site, Handling, Storage, Installation, Testing, Commissioning Including Documentation of All Items/Material required to complete works for Turnkey Based Contract For Conversion of Existing LT Line Network Including Consumer Service Lines Into Under Ground Cable Network With Ring Main System at Kamalabag Subdivision of Porbandar Circle Under PGVCL with GIS Mapping / Geo Urja Mapping (Developed by GUVNL) and Asset Tagging under SI Scheme (Package-59)
249853
PGVCL/PROJ/UGNP/KAM/P59/187
Open
Supply,erection and Commissioning
Rajkot
21 documents required · 20 mandatory · 1 optional
₹17,700
PASCHIM GUJARAT VIJ COMPANY LIMITED, Rajkot
₹1.3 Cr
5 Dec 2025
5 Dec 2025
5 Dec 2025
29 Jan 2026
5 Dec 2025
Conversion of Over Head to Underground Network
Kamalabag Sub Division of Porbandar CIty Division of Porbandar Circle
Particulars of Item Grand Total in Rs.
Particulars of Item Grand Total in Rs.
SCHEDULE-B1: CONVERSION OF EXISTING OVERHEAD ELECTRICAL HT
NETWORK IN TO UNDERGROUND CABLE NETWORK
a FOR SUPPLY PART
b FOR ERECTION PART
SCHEDULE-B2: CONVERSION OF EXISTING OVERHEAD ELECTRICAL LT
NETWORK IN TO UNDERGROUND CABLE NETWORK
a FOR SUPPLY PART
b FOR ERECTION PART
A TOTAL AMOUNT (WITHOUT GST)
A TOTAL AMOUNT (WITHOUT GST)
3 BIDDER'S OFFER ( + / - ) IN % 0.00%
4 BIDDER'S OFFER ( + / - ) IN RUPEES
B OFFERED TOTAL AMOUNT FOR SUPPLY AND ERECTION (WITHOUT GST)
B OFFERED TOTAL AMOUNT FOR SUPPLY AND ERECTION (WITHOUT GST)
5 GST @ 18% ON "B"
C GRAND TOTAL (WITH GST)
C GRAND TOTAL (WITH GST)
Date Signature of Bidder Stamp
SCHEDULE-B: CONVERSION OF OVERHEAD TO UNDERGROUND ELECTRICAL NETWORK
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
SCHEDULE-B2: CONVERSION OF OVERHEAD TO UNDERGROUND LT ELECTRICAL NETWORK
Providing & erecting XLPE(IS:7098) (I)-88 ISI marked multistrand
Aluminium conductor armoured cable ,sand for 1.1 kV to be laid on pole or
in existing cable trence/pipe at road crossing of following size of cables.
1 Work carried out up to consumer premises with meter shifting, and provide
load side cable as per site conditions and as per EIC. For consumer
premises DWC pipe should be provieded(With Excavation, back filling and
sand as per technical specification)
LT CABLE TERMINATION: Cable termination on FSP,LT Distribution
Transformer Box,MSP/SFU /Busbar etc of pole mounted transformer of LT
cable grade as specified below including cutting,stripping of
cable,insulations,providing compression type terminals,suitable cable
glands,crimping lugs with necessary connections.Work carried out up to
consumer premises with meter shifting, and provide load side cable as per
site conditions and as per EIC. For consumer premises DWC pipe should
3 Lying of all types of cable in trench(without Excavation) Mtrs. 89250.00 173 15395625
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
4 Lying of cable on pole Mtrs. 2267.40 44 99085.38
5 Lying of the cable in the Pipe(Without Excavation) 892.50 58 51318.75
6 Drilling work in Road Crossing through push through Mtrs. 11337.00 569 6453587.25
Drilling work in Road/ASPH/RCC /Hard Rock Etc(Excavation with back
filling as per the specification of cable lying)
8 Supply, intstallation of the DWC pipe(Without Excavation)
Lt cable saddling works: Direct cable saddleing with wall and etc for this
work GI type saddle and nail shall be used.
Supply, Installation, Testing, Commissioning of Half Round pipe(1000mm
Length, 4 inch dia, 1 inch thick)
PRE BONDING TAP: For laying on trench after laying cable on trech to
11 provide indication cable route below land surface in underground trench to Mtrs. 181392.00 17 3129012 181392.00 6 1043004
protect cable for mechnical injuries.
CABLE TERMINAL FERRULS: The PVC Cable terminal ferruls for
identification of phase sequence and feeder/PSS/FSP name of HT/LT
12 cables shall be provided at every termination of all cables stating detail as Nos 17504.00 28 483110.4 17504.00 9 161036.8
under. HT Cable :Feeder name/Phase(R/Y/B) LT Cable : TC/FSP
name/Phase(R/Y/B/N)
CABLE TAG: The PVC tag for identification of feeder/PSS/FSP/RMU
13 name of HT/LT cables shall be provided at every 30 MTR Nos. 29750.00 28 821100 29750.00 9 273700
HT Feeder: Substation/Feeder LT
Feeder : PSS/Transformer/FSP
EARTHING PIT : Supplying & erecting earth pit of minimum bore dia.
mm size approved make safe Earthing Electrode consisting Pipe in pipe
Technology as per IS 3043-1987 made of corrosion free G.I. Pipes having
Outer pipe dia of 50 mm having 80-200 Micron galvanising connections,
14 terminal dia of 12 mm with constant ohmic value surrounded by highly Nos. 4376.00 7475 32710600 4376.00 1150 5032400
conductive compound with high charge dissipation with civil works of
earthing chamber. For Electrical installation covering Transformer
neutrals,HT & LT switchgears for independent earthing in normal soil,
Length of Pipe 3 mtrs.Backfilling compound 2 bags of 25 Kg each.
Supply installation & commissioning of earthing conductor 38 x 3 G.I. strip
for pole mounted transformer and upto FSP,RMU,MSP,SFU, Busbar Etc as
well as connection to be made to the earth pit. Rates inclusive of hot dipped
Obtaining statutory approval from Electrical Inspector for installation
17 DISMENTALLING:
Dismentallling RCC/Rail pole with cross arm,insulators,hardwares,stay,
a etc.and return it to discom store.While dismentalling utmost care shall be Nos. 2549.00 155 395732.25
taken so that the material so that the same can be reused by discom.
Dismentalling of AAAC/ACSR/ABC/ Earth wire any size of conductor & line
b material & after making coil and stacking the same at discom store.Routte Km. 101.93 2300 234439
Dismentalling of any type of service connection from the site and material
return to DISCOM store as per directive of EIC
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
FSP (FUSE SECTION PILLER): 4 Way
Supplying and erecting 120x100x40 cms. Fuse section pillar fabricated from
4 mm Thermosetting Plastic ( moulded in a single piece ) i.e Glass
Reinforced Polyester sheet Moulding Compound (SMC ) or metal body(As
per Specification and drawings) with cable clamps to be burried in ground
to have appropriate erection on look unifrom unit erected with cement
concrete foundation and 45 cms high brick masonry internal supported on
both side with intrnal and outer side locking arrangement with lock and keys
in duplicate .Incoming switchgear SFU of TPN and outgoing HRC SMC
fuse base and knife type links 32 Amp to 630 Amp capacity fuse base
fitted on 630 Amp current capacity copper Busbar with RYB colour coding
and insulated strip with all internal connections and entry for incomming up
to 1 core 300 sq mm 4 nos and outgoing 3 nos. 31/2 core cables of
suitable sizes. (As per Technical specification of FSP ) (Erection shall be
carried out as per approved drawing and site condition) (SFU Amp Capcity
FSP (FUSE SECTION PILLER): 6 Way
Supplying and erecting 120x100x40 cms.Fuse section pillar fabricated from
4 mm Thermosetting Plastic ( moulded in a single piece ) i.e Glass
Reinforced Polyester sheet Moulding Compound (SMC ) or metal body(As
per Specification and drawings) with cable clamps to be burried in ground to
have appropriate erection on look unifrom unit erected with cement
concrete foundation and 45 cms high brick masonry internal supported on
both side with intrnal and outer side locking arrangement with lock and keys
in duplicate .Incoming switchgear SFU of TPN and outgoing HRC SMC
fuse base and knife type links 32 Amp to 630 Amp capacity fuse base
fitted on 630 Amp current capacity copper Busbar with RYB colour coding
and insulated strip with all internal connections and entry for incomming
core 300 sq mm 4 nos and outgoing 5 nos. 31/2 core cables of suitable
sizes. (As per Technical specification of FSP ) (Erection shall be carried
out as per approved drawing and site condition)(SFU Amp Capcity is as
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
MSP(Mini Section Piller) : 4 Way
Supplying and erecting 120x100x40 cms. Mini section pillar fabricated
from 4 mm thick Thermosetting Plastic(moulded in a single piece) i.e.
Glass Reinforced Polyester Sheet Moulding Compound (SMC) or
Metal Body Type Enclouser(As per Specification) with cable clamps
to be burried in ground to have appropriate erection on look uniform
unit erected with cement concrete foundation and 45 cms high brick
masonary internal supported on both side with internal and outer side
locking arrangement with lock and keys in duplicate. Incoming HRC
SMC fuse base and kinfe type links 32 Amp to 250 Amp. capacity,
fuse base fitted on 250 Amp. current capacity copper Busbar with
RYB colour coding and insulated strip with all internal connections
and entry for incoming up to 3.5 Core 300 Sq.mm 1 Nos. and
outgoing 3 nos. 3.5 core cables of suitable sizes.( As per Technical
specification of MSP)
MSP(Mini Section Piller) : 6 Way
Supplying and erecting 120x100x40 cms. Mini section pillar fabricated
from 4 mm thick Thermosetting Plastic(moulded in a single piece) i.e.
Glass Reinforced Polyester Sheet Moulding Compound (SMC) or
Metal Body Type Enclouser(As per Specification) with cable clamps
to be burried in ground to have appropriate erection on look uniform
unit erected with cement concrete foundation and 45 cms high brick
masonary internal supported on both side with internal and outer side
locking arrangement with lock and keys in duplicate. Incoming HRC
SMC fuse base and kinfe type links 32 Amp to 250 Amp. capacity,
fuse base fitted on 250 Amp. current capacity copper Busbar with
RYB colour coding and insulated strip with all internal connections
and entry for incoming up to 3.5 Core 300 Sq.mm 1 Nos. and
outgoing 5 nos. 3.5 core cables of suitable sizes.( As per Technical
specification of MSP)
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
MSP(Mini Section Piller) : 8 Way
Supplying and erecting 120x100x40 cms. Mini section pillar fabricated
from 4 mm thick Thermosetting Plastic(moulded in a single piece) i.e.
Glass Reinforced Polyester Sheet Moulding Compound (SMC) with
cable clamps to be burried in ground to have appropriate erection on
look uniform unit erected with cement concrete foundation and
cms high brick masonary internal supported on both side with internal
iii and outer side locking arrangement with lock and keys in duplicate.
Incoming HRC SMC fuse base and kinfe type links 32 Amp to
Amp. capacity, fuse base fitted on 250 Amp. current capacity copper
Busbar with RYB colour coding and insulated strip with all internal
connections and entry for incoming up to 3.5 Core 300 Sq.mm 1 Nos.
and outgoing 7 nos. 3.5 core cables of suitable sizes.( As per
Technical specification of MSP)
Supply, Instalation, Testing, Commissioning switch fuse unit made by
SMC Box and capacity of 125 A, Mostaly used in flat/Socity area.
20 Installation worked caried out with instruction of EIC. And as per the Nos. 652.00 12087 7880398 652.00 1150 749800
drawing approved by CA- Minimum 16 Nos. of CKT
SFU: Supply, Instalation, Testing, Commissioning switch fuse unit
made by SMC box and capacity of 200 A, Mostaly used in flat area.
21 Installation worked caried out with instruction of EIC. And as per the Nos. 186.00 18400 3422400 186.00 1150 213900
drawing approved by CA - Minimum 16 Nos. Of Circuit
SFU: Supply, Instalation, Testing, Commissioning switch fuse unit
made by SMC box and capacity of 400 A, Mostaly used in flat area.
22 Installation worked caried out with instruction of EIC. And as per the Nos. 93.00 20700 1925100 93.00 1323 122992.5
drawing approved by CA- Minimum 16 Nos. Of Circuit
CABLE ROUTE MARKER: Providing and erecting RCC cable route marker
23 as per drawing duly marked with "DANGER" mark, "discom POWER Nos 1833.60 345.00 632592 1833.60 115.00 210864
CABLE" and arrow of route of cable.
DRAWING: Preparing complete drawing of entire network as well as
individual feeder map showing joints also in AutoCad and providing the
same to PGVCL in AutoCad copy as ell as pdf copy and hard copy in six
sets. The drawing should be geographical indicating all directions
FENCING: FRP Fencing for FSP/MSP/SFU/BUSBAR, post shall be
made out of FRP Pultruded hollow section of size 50x50x5mm.. and
shall be grouted in the ground with c. c. of ratio 1:3:6., Sub frame
provided using hollow FRP section 50x25x5mm or FRP angles
50x50x5 at top and bottom and other accessories for fixing of gates
etc. Rails shall be made out of FRP notch bars of 12mm dia, Pickets
shall be made of flats of size 35x5mm SMC or FRP as per
Paint Pointed Letter 2 inch size(Marking on FSP, MSP, SFU Etc In any
palce.(As per directive of Engineer Incharge) with supply of color
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
27 HRC Fuse and its Fuse base(Spare)
28 Jointing Kit for LT Cable
Total LT-UG (Supply+ Erection) 481610065 86920125
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Part-I P-59-187.pdf
2.Employers requirement.pdf
3. Technical Specifications.pdf
4. CoC- P59-187.pdf
5. Declaration of Authorised person and Confict of Interest.pdf
6. Reference Tender Drawing Robust Network.pdf
7. Schedule-B-UGNP-KAM-P59-187.pdf
TLE -Amendment-1.pdf
TLE -Amendment-2.pdf
TLE -Amendment-3.pdf
TLE -Amendment-4.pdf
Download all tender documents and submit your bid