Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | Rejected-Technical | - | Rejected-Technical Techinically disqualified | |
| 3 | Rejected-Technical | - | Rejected-Technical Techinically disqualified |
| Sl No | Description | Qty | Unit | Cooltek India L1 |
|---|---|---|---|---|
| 1.00PART -A (Consisting of Manpower and scope of work for Comprehensive Maintenance) | ||||
| 1.01Manpower for Round the clock operation | ||||
| 1.02 | Salaries for Semi Skilled Technicians: - Wages to be paid for engaging semi-skilled technicians engaged for round the clock Operation and Maintenance of all firefighting equipment in UG Sump and only maintenance of Firefighting equipment as mentioned in below BOQ during 365 days (24 Hours X 7days). The scope also covers operation of pumps valves and also initial assistance in defect rectification subjected to firefighting equipment. The contarctor scope also includes the below mentioned works :-
(a) The rates shall include deputation of technicians in each shift including Technicians for reliver.The rates shall also include all the charges i.e., ESI, EPF, bonus, GST or any other miscellaneous charges which shall be paid from the contractor to the Technician.
(c) The contractor should provide required number of Technicians after visiting the site assessing the BOQ and scope of work with the below mentioned qualifications. The eligibility criteria of technicians will be verified by this department prior to recruiting by the contractor.
(d) The manpower must have single point of contact for regular communication and scheduling of maintenance.
(i) Mechanical Technician with SSC (Full Time) plus 02 years of ITI (Mechanical Trade through NCVT and experience of 03 Years as Pumps, valve operation and maintenance, Fire & safety drills and procedure.
(ii) Electrician with SSC (Full Time) Plus ITI (Electrician through NCVT) 02-year full-time course from Government recognized Institute with 05 years’ experience in Electrical Maintenance works in Industry/Hospitals after ITI. The electrician should possess electrical wiremen certification.
(e) The Bidder should provide 02 pairs of uniform Set ( Tshirt/Shirt & Trouser /Cargo Pant)with imprint of “Fire Technician” on back of the T-Shirt/Shirt and “Company Logo” on Front side of Pocket and Cargo Pant with multiple pockets . The bidder should provide 01 pair of safety shoes per each year. The charges for 02 No's uniform Set and safety shoes should be considered in the manpower charges only.
(f) The Contractor should Liase/Co ordinate , with Andhra pradesh State Disaster Response & Fire Service Dept. for Renewal of Occupancy NOC of all 09 No's Blocks in Hospital Campus so as to comply with the observations raised during surprise visit ,inspections and rounds .The processing fees for renewal of NOC will be paid by HBCH&RC,Visakhapatnam | 1 | Job | 26,97,480 ₹26,97,480 Lowest |
| 2.00Fire Fighting System: This CAMC includes Diesel Engine Driven Pump, Electrcal driven pump, Jockey pump, Domestic water pumps, Terrace Booster pumps, Dewatering pumps, Air cushion tank, Valves, Sprinklers, Guages, Flow switches, Pressure switches, Strainers, External Hydrants, Hose reels, Internal and external Fire hose boxes, Hose pipes, Branch pipes, Siamese connections, Fire Brigade Breaching Inlets, Air Cushion tank. | ||||
| 2.01 | CMC for Diesel driven Pump consisting of Pump and Diesel Engine ( 01 Set):- Including Maintenance of DG Set considering A-Check, B-Check & C- Check as recommended by the Engine Manufacturer , including all consumable and Non Consumable spares. Replacement of Batteries as and when required for staring of the engine , Repair /Replacment of Engine electronics, Safety switches , SMPS Switch.
Pump unit of Diesel Engine Driven Pump (Quantity - 01 No's) :- Centrifugal Horizontal split case fire fighting pump set having capacity of 2280 LPM at 88m head along with all accessories with Cl casing, standard fitting, bronze impeller, Stainless Steel shaft mechanical seal with water cooled heat exchanger diesel engine, having speed of 1500 rpm.CMC Including consumable and non consumable spares ,routine/scheduled maintenance cleaning of strainers, replacement of gaskets, vibration pads if required,alignment of engine with pump if required, Greasing at greasing points, replacement of seals and arrest any leaks from fittings and making operational for 24X7 operation in all respect Replacement of faulty pressure gauges Vibration Pads when required.Any other minor repairs in all respects to make the equipment operationally available 24X7 Maintenance of all associated pipelines for painting conosion Rubber Joint replacements, arresting of any type of leaks is also included.Note:- Major repairs in Pump has to be undertaken by authorised/OEM of the Pump.
PUMP MAKE KIRLOSKAR,PUMP TYPE DSM 100/36,CENTRIFUGAL PUMP, PUMP NO. 1723017352
QA NO. D10318A548/200 TOTAL HEAD-88M, DISCHARGE 136.800M3/HR,PUMP INPUT -44.459 KW,IMP DIA MM BR/365 SIZE & RPM 100 X 125 & 1500 MAT CODE 43,RECOMMENDED PRIME MOVER RATING -127 HP.
ENGINE Unit of Diesel Engine Driven Pump (Quantity - 01 No's) :- CMC Including consumable and non consumable spares ,routine/scheduled maintenance Supply of the charge of lubricants, fuel, distilled water for battery and other consumables related to Diesel Engine shall be included.CMC including Repair/Replacement of batteries, Strating Motor Dynamo, Air & Lub Oil Filters, replacement of rubber hose/bellows, Exhaust bellows, Silencer, Belts, Jubliee Clips.Any other minor repairs in all respects to make the equipment operationally available 24X7 Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included. Note:- CMC to be undertaken by authorised/OEM of the Engine and Diesel for running the engine will be provided from HBCH&RC,Visakhapatnam
ENGINE TYPE 6R1080T,RATING KW/HP 93.47/127 HP,RPM 1500,RATING &STD ISO& 3046 thick
GOVERNNG CLASS M2, ENGINE NO.6H.2410.10/1720022,(DISEL SPRIEYR )BOSCH F0002 A0Z 421/PES6A95D320RS3559,BOSH SL NO. 75809688,BATTRIES MAKE EXIDE CARE BATTRIES QTY -02 NOS,ENGINE AIR CLEANER F6.504.01.0.00 | 1 | Job | 14,160 ₹14,160 Lowest |
| 2.02 | CMC for Main Fire fighting pump (Electrical driven) (Quantity - 01 No's) : Motor driven Centrifugal Horizontal,split case Fire fighting pump set along with all accessories capacity of 2280 LPM at 88m head with Cl casing, mechanical seal standard fittings, Stainless Steel shaft, bronze impeller, suitably rated electrical driven squirrel cage induction motor running at 1500 rpm (synchronous speed) with insulation, IP-55, suitable to operate 415 V +/- 10% 50 Hz +/- 3%, 3 phase AC supply, including supplying MS common base plate frame and foundation bolts, anti vibration pads complete with coupling guard & all other accessories etc. CMC Including cleaning of strainers,replacement of gaskets, vibration pads if required, Greasing at greasing points, replacement of seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Replacement of faulty pressure gauges, Vibration Pads when required Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.Any other minor repairs in all respects to make the equipment operationally available 24X7 Maintenance of all associated pipelines for painting conosion Rubber Joint replacements, arresting of any type of leaks is also included.
Note:- Major repairs in Pump has to be undertaken by authorised/OEM of the Pump.
PUMP MAKE: KIRLOSKAR PUMP
TYPE DSM/100/36, PUMP L CUPLING SW-276032
QA NO. D10318A548/100,TOTAL HEAD -88 M DISCHARGE, 136.800 M3/HR, PUMP INPUT,PUMP NO 44.303,1723017353 IMP DIA MM BR/362,SIZE & RPM 100 X 125 & 1480 MAT CODE 43 RECOMMENDED PRIME MOVER RATING-75 KW
MOTOR MAKE CG APEX,MACHINE NO. 75KE4, KW & HP -75.0 & 100.00 HP, VOLTS -415 +/- 10%, BRG DE/NDE 6318-C3/6318- C3,GREASE UNIREX N3IEC 60034-1: IE2, REF QLAM RELUB HRS 20643, 5800 RPM & AMP 1480 & 126A DELTA FRAME NO. 280S EFF, 94.00% GREASE QTY / SHAFT 120 grams, HALF KEY BALANCED | 1 | Job | 14,160 ₹14,160 Lowest |
| 2.03 | CMC for Fire fighting Jockey pump (Quantity - 01 No's) :- Motor driven Centrifugal End suction top discharge Jockey pump set for fire fighting system of capacity of 180 LPM at 88m head along with all accessories, mechanical seal, Cl casing, Stainless Steel shaft, standard fittings, bronze impeller, electrical driven suitably rated squirrel cage induction motor with synchronous speed not exceeding 2950 rpm with Class-F insulation, IP-55 to operate at 415 V+/- 10% 50 Hz+/- 3% 3 phase AC Supply, including supplying MS common base plate.C CMC Including cleaning of strainers, replacement of gaskets, vibration pads if required, Greasing at greasing points,replacement of seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Replacement of faulty pressure gauges, Vibration Pads when required.Any other minor repairs in all respects to make the equipment operationally available 24X7 Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.
Note:- Major repairs in Pump has to be undertaken by authorised/OEM of the Pump.
PUMPS MAKE: KIRLOSKAR,PUMP TYPE CPHM 25/26 A,PUMP NO. 1789317778,PUMP INPUT SIZE 7.840 KW 25x80mm,TOTAL HEAD-88m, DISCHARGE -10.800 M3/Hr,IAMP DIA MM BR/247/300
MAT CODE 43, PUMP RPM 2926rpm, MOTOR MAKE CG apex, KW & HP 11.0 & 15.0 hp RPM 2925, VOLT /AMP 415 ± 10%/19A,REF QKAM2607 BEARING DE/NDE,6209-2Z/ 6209-2Z GREASE SHAFT IEC 60034-1 E2half key balanced, FRAME ND 160 M, EFF & HZ 89.40% & 50 ± 5% PF & CONN DIAG 0.88 & 302 DUTY & IP,S1 & 55 | 1 | Job | 21,972.78 ₹21,972.78 Lowest |
| 2.04 | CMC for Terrace pumps (Quantity - 08 No's) (Comprehensive Maint. Contract includes) :-CMC Including cleaning of strainers,replacement of gaskets,vibration pads if required, Greasing at greasing points, replacement of seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.
PUMP MAKE KIRLOSKAR BROTHERS LTD, PUMP TYPE DB40/16, PUMP L COUPLING 024/8/27.3 , TOTAL HEAD -35 M, DISCHARGE -27 M3/HR, KW & HP 7.5 KW& 10 HP | 1 | Job | 14,160 ₹14,160 Lowest |
| 2.05 | CMC for Domestic water pumps (Quantity - 02 No's) (Comprehensive Maint. Contract includes) :- CMC Including cleaning of strainers,replacement of gaskets, vibration pads if required, Greasing at greasing points, replacement of Mechanical seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.
PUMP MAKE-KIRLOSKAR BROTHERS LTD, TOTAL HEAD 70 M DISCHARGE 67.600 M3/Hr, | 1 | Job | 21,240 ₹21,240 Lowest |
| 2.06 | CMC for UG Sump Submerisible Dewatering water pumps (Quantity - 01 No's) :- CMC Including cleaning of strainers, replacement of gaskets,vibration pads if required, Greasing at greasing points,replacement of seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.
PUMP MAKE KIRLOSKAR BROTHERS LTD, PUMP MODEL 750CW-HEAD REANG 4.5 TO 14 DIS REANG,6-1 DEL SIZE, 50MM PUMP TYPE, SUBMERSIBLE MOTOR KW/HP,0.75 /01 HP RPM 2900,AMP 1.63A,MAX SOLDE SIZE 20 MM, RPM 1450, 50HZ. | 1 | Job | 14,160 ₹14,160 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Aug 2026, 5:30 pmClosed
Director, HBCHRC, Visakhapatnam
Homi Bhabha Cancer Hospital Research Center, Visakhapatnam, Andhra Pradesh, 530053
Operation and Comprehensive Maintenance Contract (CMC) for various Fire Fighting Equipments at Homi Bhabha Cancer Hospital Research Center
2026_TMC_917523_1
HBCHRC/Mech/2026-27/NIT/01 dated 15/07/2026
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
365 days
Homi Bhabha Cancer Hospital Research Center
as per NIT
2 documents required · 2 mandatory
₹0
₹60,000
Homi Bhabha Cancer Hospital Research Center, Vis
1 Oct 2026
16 Jul 2026
26 Aug 2026
16 Jul 2026
19 Aug 2026
16 Jul 2026
16 Jul 2026 - 30 Jul 2026
23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1PART -A (Consisting of Manpower and scope of work for Comprehensive Maintenance) | |||||
| 1.01 | Manpower for Round the clock operation | - | - | - | - |
| 1.02 | Salaries for Semi Skilled Technicians: - Wages to be paid for engaging semi-skilled technicians engaged for round the clock Operation and Maintenance of all firefighting equipment in UG Sump and only maintenance of Firefighting equipment as mentioned in below BOQ during 365 days (24 Hours X 7days). The scope also covers operation of pumps valves and also initial assistance in defect rectification subjected to firefighting equipment. The contarctor scope also includes the below mentioned works :-
(a) The rates shall include deputation of technicians in each shift including Technicians for reliver.The rates shall also include all the charges i.e., ESI, EPF, bonus, GST or any other miscellaneous charges which shall be paid from the contractor to the Technician.
(c) The contractor should provide required number of Technicians after visiting the site assessing the BOQ and scope of work with the below mentioned qualifications. The eligibility criteria of technicians will be verified by this department prior to recruiting by the contractor.
(d) The manpower must have single point of contact for regular communication and scheduling of maintenance.
(i) Mechanical Technician with SSC (Full Time) plus 02 years of ITI (Mechanical Trade through NCVT and experience of 03 Years as Pumps, valve operation and maintenance, Fire & safety drills and procedure.
(ii) Electrician with SSC (Full Time) Plus ITI (Electrician through NCVT) 02-year full-time course from Government recognized Institute with 05 years’ experience in Electrical Maintenance works in Industry/Hospitals after ITI. The electrician should possess electrical wiremen certification.
(e) The Bidder should provide 02 pairs of uniform Set ( Tshirt/Shirt & Trouser /Cargo Pant)with imprint of “Fire Technician” on back of the T-Shirt/Shirt and “Company Logo” on Front side of Pocket and Cargo Pant with multiple pockets . The bidder should provide 01 pair of safety shoes per each year. The charges for 02 No's uniform Set and safety shoes should be considered in the manpower charges only.
(f) The Contractor should Liase/Co ordinate , with Andhra pradesh State Disaster Response & Fire Service Dept. for Renewal of Occupancy NOC of all 09 No's Blocks in Hospital Campus so as to comply with the observations raised during surprise visit ,inspections and rounds .The processing fees for renewal of NOC will be paid by HBCH&RC,Visakhapatnam | 1 | Job | - | - |
| 2Fire Fighting System: This CAMC includes Diesel Engine Driven Pump, Electrcal driven pump, Jockey pump, Domestic water pumps, Terrace Booster pumps, Dewatering pumps, Air cushion tank, Valves, Sprinklers, Guages, Flow switches, Pressure switches, Strainers, External Hydrants, Hose reels, Internal and external Fire hose boxes, Hose pipes, Branch pipes, Siamese connections, Fire Brigade Breaching Inlets, Air Cushion tank. | |||||
| 2.01 | CMC for Diesel driven Pump consisting of Pump and Diesel Engine ( 01 Set):- Including Maintenance of DG Set considering A-Check, B-Check & C- Check as recommended by the Engine Manufacturer , including all consumable and Non Consumable spares. Replacement of Batteries as and when required for staring of the engine , Repair /Replacment of Engine electronics, Safety switches , SMPS Switch.
Pump unit of Diesel Engine Driven Pump (Quantity - 01 No's) :- Centrifugal Horizontal split case fire fighting pump set having capacity of 2280 LPM at 88m head along with all accessories with Cl casing, standard fitting, bronze impeller, Stainless Steel shaft mechanical seal with water cooled heat exchanger diesel engine, having speed of 1500 rpm.CMC Including consumable and non consumable spares ,routine/scheduled maintenance cleaning of strainers, replacement of gaskets, vibration pads if required,alignment of engine with pump if required, Greasing at greasing points, replacement of seals and arrest any leaks from fittings and making operational for 24X7 operation in all respect Replacement of faulty pressure gauges Vibration Pads when required.Any other minor repairs in all respects to make the equipment operationally available 24X7 Maintenance of all associated pipelines for painting conosion Rubber Joint replacements, arresting of any type of leaks is also included.Note:- Major repairs in Pump has to be undertaken by authorised/OEM of the Pump.
PUMP MAKE KIRLOSKAR,PUMP TYPE DSM 100/36,CENTRIFUGAL PUMP, PUMP NO. 1723017352
QA NO. D10318A548/200 TOTAL HEAD-88M, DISCHARGE 136.800M3/HR,PUMP INPUT -44.459 KW,IMP DIA MM BR/365 SIZE & RPM 100 X 125 & 1500 MAT CODE 43,RECOMMENDED PRIME MOVER RATING -127 HP.
ENGINE Unit of Diesel Engine Driven Pump (Quantity - 01 No's) :- CMC Including consumable and non consumable spares ,routine/scheduled maintenance Supply of the charge of lubricants, fuel, distilled water for battery and other consumables related to Diesel Engine shall be included.CMC including Repair/Replacement of batteries, Strating Motor Dynamo, Air & Lub Oil Filters, replacement of rubber hose/bellows, Exhaust bellows, Silencer, Belts, Jubliee Clips.Any other minor repairs in all respects to make the equipment operationally available 24X7 Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included. Note:- CMC to be undertaken by authorised/OEM of the Engine and Diesel for running the engine will be provided from HBCH&RC,Visakhapatnam
ENGINE TYPE 6R1080T,RATING KW/HP 93.47/127 HP,RPM 1500,RATING &STD ISO& 3046 thick
GOVERNNG CLASS M2, ENGINE NO.6H.2410.10/1720022,(DISEL SPRIEYR )BOSCH F0002 A0Z 421/PES6A95D320RS3559,BOSH SL NO. 75809688,BATTRIES MAKE EXIDE CARE BATTRIES QTY -02 NOS,ENGINE AIR CLEANER F6.504.01.0.00 | 1 | Job | - | - |
| 2.02 | CMC for Main Fire fighting pump (Electrical driven) (Quantity - 01 No's) : Motor driven Centrifugal Horizontal,split case Fire fighting pump set along with all accessories capacity of 2280 LPM at 88m head with Cl casing, mechanical seal standard fittings, Stainless Steel shaft, bronze impeller, suitably rated electrical driven squirrel cage induction motor running at 1500 rpm (synchronous speed) with insulation, IP-55, suitable to operate 415 V +/- 10% 50 Hz +/- 3%, 3 phase AC supply, including supplying MS common base plate frame and foundation bolts, anti vibration pads complete with coupling guard & all other accessories etc. CMC Including cleaning of strainers,replacement of gaskets, vibration pads if required, Greasing at greasing points, replacement of seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Replacement of faulty pressure gauges, Vibration Pads when required Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.Any other minor repairs in all respects to make the equipment operationally available 24X7 Maintenance of all associated pipelines for painting conosion Rubber Joint replacements, arresting of any type of leaks is also included.
Note:- Major repairs in Pump has to be undertaken by authorised/OEM of the Pump.
PUMP MAKE: KIRLOSKAR PUMP
TYPE DSM/100/36, PUMP L CUPLING SW-276032
QA NO. D10318A548/100,TOTAL HEAD -88 M DISCHARGE, 136.800 M3/HR, PUMP INPUT,PUMP NO 44.303,1723017353 IMP DIA MM BR/362,SIZE & RPM 100 X 125 & 1480 MAT CODE 43 RECOMMENDED PRIME MOVER RATING-75 KW
MOTOR MAKE CG APEX,MACHINE NO. 75KE4, KW & HP -75.0 & 100.00 HP, VOLTS -415 +/- 10%, BRG DE/NDE 6318-C3/6318- C3,GREASE UNIREX N3IEC 60034-1: IE2, REF QLAM RELUB HRS 20643, 5800 RPM & AMP 1480 & 126A DELTA FRAME NO. 280S EFF, 94.00% GREASE QTY / SHAFT 120 grams, HALF KEY BALANCED | 1 | Job | - | - |
| 2.03 | CMC for Fire fighting Jockey pump (Quantity - 01 No's) :- Motor driven Centrifugal End suction top discharge Jockey pump set for fire fighting system of capacity of 180 LPM at 88m head along with all accessories, mechanical seal, Cl casing, Stainless Steel shaft, standard fittings, bronze impeller, electrical driven suitably rated squirrel cage induction motor with synchronous speed not exceeding 2950 rpm with Class-F insulation, IP-55 to operate at 415 V+/- 10% 50 Hz+/- 3% 3 phase AC Supply, including supplying MS common base plate.C CMC Including cleaning of strainers, replacement of gaskets, vibration pads if required, Greasing at greasing points,replacement of seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Replacement of faulty pressure gauges, Vibration Pads when required.Any other minor repairs in all respects to make the equipment operationally available 24X7 Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.
Note:- Major repairs in Pump has to be undertaken by authorised/OEM of the Pump.
PUMPS MAKE: KIRLOSKAR,PUMP TYPE CPHM 25/26 A,PUMP NO. 1789317778,PUMP INPUT SIZE 7.840 KW 25x80mm,TOTAL HEAD-88m, DISCHARGE -10.800 M3/Hr,IAMP DIA MM BR/247/300
MAT CODE 43, PUMP RPM 2926rpm, MOTOR MAKE CG apex, KW & HP 11.0 & 15.0 hp RPM 2925, VOLT /AMP 415 ± 10%/19A,REF QKAM2607 BEARING DE/NDE,6209-2Z/ 6209-2Z GREASE SHAFT IEC 60034-1 E2half key balanced, FRAME ND 160 M, EFF & HZ 89.40% & 50 ± 5% PF & CONN DIAG 0.88 & 302 DUTY & IP,S1 & 55 | 1 | Job | - | - |
| 2.04 | CMC for Terrace pumps (Quantity - 08 No's) (Comprehensive Maint. Contract includes) :-CMC Including cleaning of strainers,replacement of gaskets,vibration pads if required, Greasing at greasing points, replacement of seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.
PUMP MAKE KIRLOSKAR BROTHERS LTD, PUMP TYPE DB40/16, PUMP L COUPLING 024/8/27.3 , TOTAL HEAD -35 M, DISCHARGE -27 M3/HR, KW & HP 7.5 KW& 10 HP | 1 | Job | - | - |
| 2.05 | CMC for Domestic water pumps (Quantity - 02 No's) (Comprehensive Maint. Contract includes) :- CMC Including cleaning of strainers,replacement of gaskets, vibration pads if required, Greasing at greasing points, replacement of Mechanical seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.
PUMP MAKE-KIRLOSKAR BROTHERS LTD, TOTAL HEAD 70 M DISCHARGE 67.600 M3/Hr, | 1 | Job | - | - |
| 2.06 | CMC for UG Sump Submerisible Dewatering water pumps (Quantity - 01 No's) :- CMC Including cleaning of strainers, replacement of gaskets,vibration pads if required, Greasing at greasing points,replacement of seals and arrest any leaks from fittings and make operational for 24X7 operation in all respect. Maintenance of all associated pipelines for painting, corrosion, Rubber Joint replacements, arresting of any type of leaks is also included.
PUMP MAKE KIRLOSKAR BROTHERS LTD, PUMP MODEL 750CW-HEAD REANG 4.5 TO 14 DIS REANG,6-1 DEL SIZE, 50MM PUMP TYPE, SUBMERSIBLE MOTOR KW/HP,0.75 /01 HP RPM 2900,AMP 1.63A,MAX SOLDE SIZE 20 MM, RPM 1450, 50HZ. | 1 | Job | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.21 MB
SCC.pdf
Additional Documents • 0.74 MB
TenderDocument.pdf
Tender Documents • 2.14 MB
FormOfAgreement.pdf
Additional Documents • 0.51 MB
BOQ_964229.xls
BOQ • 0.37 MB
LetterOfTransmittal.pdf
Additional Documents • 0.63 MB
FORMSATOH.xls
Tender Documents • 0.06 MB
ScopeOfWork.pdf
Tender Documents • 0.59 MB
PreferredMake.pdf
Additional Documents • 0.44 MB
MaintenanceFormat.pdf
Additional Documents • 0.80 MB
Corrigendum01.pdf
PDF • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .