Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE South Tezpur
GE South Tezpur Mission Chariali
REPAIR/MAINTENANCE OF SUMMER APPLIANCES, WINDOW/SPLIT ACs, COLD STORAGE, PACKAGE PLANT WITH ALLIED WORKS UNDER GE (S) TEZPUR
2026_MES_794213_1
8204
Open Tender
Civil Works
Item Rate
210 days
GE South Tezpur
as per NIT
4 documents required · 4 mandatory
₹500
GE South Tezpur
₹90,000
Yes
15 Oct 2026
15 Oct 2026
6 Nov 2026
15 Oct 2026
4 Nov 2026
28 Oct 2026
15 Oct 2026 - 21 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and installation of AC Compressor of capacity 3 Phase, 5 TR package unit, Model No. ZR-72 , including compressor oil in existing position including new connections with all control lines with necessary copper fittings (which requires a welding set), copper lugs, copper cables etc with controlled unit for smooth running, complete all as specified and directed. | 6 | Each | - | - |
| 2 | Supply and installation of AC Compressor of capacity 3 Phase, 3 TR package unit, including compressor oil in existing position including new connections with all control lines with necessary copper fittings (which requires a welding set), copper lugs, copper cables etc with controlled unit for smooth running, complete all as specified and directed. | 7 | Each | - | - |
| 3 | Supply and fixing sub zero compressor controller for two compressor including connection and wiring at specified location and testing complete all as specified and directed. | 8 | Each | - | - |
| 4 | Supply and fixing sub zero compressor Timer for two compressor including connection and wiring at specified location and testing complete all as specified and directed. | 7 | Each | - | - |
| 5 | Supply and fixing in repair HP switch for 3/5 ton compressor for cold storage plant complete all as specified and directed. | 9 | Each | - | - |
| 6 | Supply and fixing in repair LP switch for 3/5 ton compressor for cold storage plant complete all as specified and directed. | 8 | Each | - | - |
| 7 | Supply and fixing in repair blower fan motor (indoor unit) for 5 ton compressor as per site complete all as specified and directed. | 11 | Each | - | - |
| 8 | Supply and fixing in repair fan motor (outdoor unit) for 5 ton compressor as per site complete all as specified and directed. | 6 | Each | - | - |
| 9 | Supply and fixing in repair blower fan motor (indoor unit) for 3 ton compressor as per site complete all as specified and directed. | 7 | Each | - | - |
| 10 | Supply and fixing in repair fan motor (outdoor unit) for 3 ton compressor as per site complete all as specified and directed. | 4 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
Tenderdocus.pdf
Tender Documents • 1.27 MB
BOQ_890740.xls
BOQ • 0.48 MB
Addldocus.pdf
Additional Documents • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .