Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC GOKUL APARTMENT PANJABIPARA DISTT JALPAIGURI SILIGURI 734401 WB | DARJEELING | WEST BENGAL | 734401 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND BEING L1 BIDDER | |
| 2 | L2₹27.8 L+₹6.2 L (28.7%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L2 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER | |
| 3 | L3₹28.1 L+₹6.5 L (30.0%)Rejected-Finance POST BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L3 | Rejected-Finance BEING OTHER THAN LOWEST BIDDER |
Tender Value
₹31.5 L
EMD Value
₹63,000
Closing Date
7 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE BINNAGURI
HQ CWE BINNAGURI, BINNAGURI CANTT, JALPAIGURI, WEST BENGAL, PIN-735232
ADDITION/ALTERATION AND SPL REPAIR TO CERTAIN OTM ACCN AT BINNAGURI MIL STN UNDER GE NORTH BINNAGURI
2024_MES_671545_1
8166/E8
Open Tender
Civil Works
Item Rate
180 days
GE NORTH BINNAGURI
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (N) BINNAGURI
₹63,000
Yes
7 Dec 2024
4 Sept 2024
8 Oct 2024
4 Sept 2024
7 Oct 2024
18 Sept 2024
Amount
Supply and install hi wall split units indoor/outdoor of 2.0 TR capacity complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity including necessary wall bracket for hanging of units, complete all as specified and directed by Engineer-in-charge.
Supply and install hi wall split units indoor/outdoor of 1.5 TR capacity complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity including necessary wall bracket for hanging of units, complete all as specified and directed by Engineer-in-charge.
M&L for sub main wiring two run of size 6 sqmm PVC insulated, ISI marked, FRLSH unsheathed, electric power cable (heavy duty) 1100 volts grade with stranded copper conductor with 6.0 sqmm PVC insulated stranded copper conductor earth wire in PVC conduit of suitable size (two run of 6 sqmm cable and one of 6.0 sqmm wire and one run of PVC conduit will be measured as one unit)including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge.
S&F of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240 Volt, complete all as specified and as directed by Engineer-in-charge.
Supply, fixing & testing of 35 Sqmm, 3.5 Core XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100Volt grade on walls with fixing accessories including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge. Note - Earthwork, sand cushioning, bricks, GI pipe, etc. shall be measured and paid separately.
Excavation in trenches n. exc 1.5m wide and n. exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n. exc 10 sqm on plan and n. exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in hard/dense soil, complete all as per specified and as directed by Engineer-in-charge.
Removing excavated Soil materials to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point, complete all as per specified and as directed by Engineer-in-charge.
M&L sand cushioning (dry) in trenches for protection of UG cables (below, above and around the cable laid in trenches) of 230mm spreding thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed by Engineer-in-charge. Note - Only punned thickness shall be measured and paid.
S&F GI tube 50 mm bore light grade for cable protection with all fitting, laid in trenches, complete all as specified and as directed by Engineer-in-charge.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting 50 to 80 mm bore GI pipe, Complete all as specifed and directed by Engineer-in-Charge. Note :- GI pipe Shall be measured and paid respective
Supply & Laying sub class B bricks of size 25cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat including taking down old unserviceable one, complete all as specified and as directed by Engineer-in-charge.
Supply and fix of sheet metal enclosure powder painted for MCB SPN 8 way double door DB, 240 Volts, 200 Amp with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed by Engineer-in-charge.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of TPN/FP 40 to 100 AMP and current carrying capacity in the DB complete with connection testing and commissioning, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP 6 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed by Engineer-in-charge.
S&F of SS Wall Mounted Chimney hood with SS Filter of size 15'(L)(180")L x 30"(W) x20" (H) SS grade-304, ISI mark to discharge out hot gases to the atmosphere, complete all as specified and as directed by Engineer-in-charge.
M&L for Hot air ducting made out with GI sheet of grade 18' with insulation for dichaging out exhaust gases from the chemney to the atmosphere, complete all as specified and as directed by Engineer-in-charge.
S&F of Exhaust Fan (18" dia) 1420 RPM, minimize noise with AC single phase 240V, 50 Hz suitable for above mention Chimney with all accessories complete, complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S SINHA ENTERPRISE (BID ID -3112475)
M/S East India Traders (BID ID -3131481)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .