Tender Value
Refer Docs
EMD Value
₹42,000
Closing Date
25 Nov 2022, 6:00 pmClosed
Major Sameer Wadekar
Holta Cantt Palampur
REPAIR MAINTENANCE AND IMPROVEMENT TO E AND M INSTALLATION REPAIR TO DG SETS PUMP MOTORS SECURITY LIGHTS AND MES INSTLALLATION FENCING AND DRAIN AT PALAMPUR MIL STN
2022_MES_560230_1
GEP-34/2022-23
Open Tender
Civil Works
Item Rate
180 days
Palampur Mil Stn
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Palampur
₹42,000
Yes
26 Dec 2022
28 Oct 2022
28 Nov 2022
28 Oct 2022
25 Nov 2022
11 Nov 2022
Amount
Labour only for checking the serviceability of the different spares / components / parts of security light fittings/post top lantern light fittings (LED, flood light/focus light etc, any wattage/capacity) of any description and fixed in any position, replacement of un-serviceable/damaged/ broken part(s) either in single or in combination, re-assembling the fittings and making the light fittings serviceable, fixing the fittings in position, connecting to electric supply and its testing on installation complete all as specified and directed. NOTES:- (i) Replacement of parts i.e LED driver for Flood light/ LED/Focus light fittings any wattage & capacity, if any required at site, shall be measured and paid for separately under appropriate item of Schedule `A'/BOQ as ‘supply only.
(ii) Necessary T&P i.e. ladder, tools etc required for checking and making the light fittings in serviceable conditions, its fixing in position and testing shall be arranged by the contractor at his own cost for checking and fixing of street light fittings/security light fittings of any description on poles / on walls / on pillars etc i.e. in any position at site. (iii) Required screws, insulating tapes, internal wiring wire and other minor items excluding the required spares parts for repairing and making the street light fittings/security light fittings in serviceable condition, will be arranged & supplied by the contractor and cost of which is deemed to be included in the rates quoted by the contractor in above respective item. (iv) Contractor shall be paid only one time the labour charges quoted above in Schedule `A' items for a particular fitting repaired irrespective of the number of times labour and resources arranged by him to check the serviceability of the fittings and replacement of unserviceable / defective parts in order to maintain the fittings in serviceable/working condition.
(v) Contractor’s quoted rates for is deemed to include for inspection/checking the serviceability of the fittings in position or by taking down as per site requirement, removing the damaged unserviceable / broken parts, fixing the new parts as required, fixing the fittings in same position or the other, connecting the fittings with electric source and testing of fittings as directed.
Disconnecting and taking out existing unserviceable light fitting of any description and in any position on poles and S&F 20W LED Post top lantern complete accessories to be fixed on pole/wall including connecting the fitting to control switch at the bottom of the pole with using 2.5 Sqmm two single core PVC insulated and unsheathed copper conductor copper conductor cable complete all as specified and directed . Make:- Bajaj Cat Part No- BGCT W4 LED WW/Crompton Cat NoL PTH-20 CDL/Havells Cat Part No RUBYPT25WLED830SSYMTOPC
Disconnecting and taking out existing Flood light fitting of any description and in any position on High mast 16.0/12.0 mtr hight poles and Supply, fixing & testing 200 W LED flood light with pressure die-cast aluminium housing, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. Make:- Philips Cat No BVP184 LED 196/197 /184 CW / NW / WW FG WB 200W PSU/Bajaj Cat part No BJFL 200W LED/Havells Cart No JETAIRISMAXFL200WLED757PWBLTG Note:- GI pipe bracket and clamps if required shall be measured and paid separately.
Disconnecting and taking out existing Street light fitting of any description and in any position on Street light poles and Supply, fixing & testing 45W LED street light fitting IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens embdded PC cover complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed.(Make- Philips Cat NoBRP031 LED45 CW / WW MR PSU GR DX Bajaj Cat Part No ENXT P 54L WH CR PC SD/Havells Cart Part No ENDURASUNDOWNSL45WLED765PASYBOTG Note : GI pipe bracket and clamps if required shall be measured and paid separately.
Disconnecting and taking out existing Street light fitting of any description and in any position on Street light poles and Supply, fixing & testing 60W LED street light fitting IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. Make:- Philips Cat No BRP032 LED60 CW / WW SLR GR PSU Bajaj Cat Part No ENXT P 72L WH CR PC SD/Havells Cat part No ENDURAPEARLNEOSL 60WLED757PASY TOPCAST Note:- GI pipe bracket and clamps if required shall be measured and paid separately.
Disconnecting and taking out existing Street light fitting of any description and in any position on Street light poles and Supply, fixing & testing 90W LED street light IP66 Powder coated pressure die cast aluminium High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arragement for mounting on existing MS frame bracket including connecting the fitting complete all as specified and directed. Make:- Crompton Cat No TRP-411-90-57-SL-GL-NSG / Bajaj Cart No BRTFG 90W LED CRor/ Havells cat part No ENDURAOMNIPLUSSL90WLED757SASY TOPC Note:- GI pipe bracket and clamps if required shall be measured and paid separately.
Supply only LED Driver suitable for street/flood light 45 to 48 Watt working on 230 volts AC supply, complete all as specified and directed.
Supply only LED Driver suitable for street/flood light 50 to 60 Watt working on 230 volts AC supply, complete all as specified and directed.
Supply only LED Driver suitable for street/flood light 70 to 90 Watt working on 230 volts AC supply, complete all as specified and directed.
Supply only LED Driver suitable for street/flood light 100 to 150 Watt working on 230 volts AC supply, complete all as specified and directed.
Taking down existing unserviceable bracket complete and S&F 32mm dia GI light grade pipe 2.0m long with bracket bent to shape by cutting & welding as required & directed and fixed to pole with two No's of FI clamps 40mm x 5mm to be tightened with bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F in repairs cable junction box made of thermoplastic, halogen free, weather proof with metric Knock outs for cable entry including four/five pole terminals and cable entry glands for incomming, out going and connection cable with protection grade IP-66/67 of size 205x255x112 mm and suitable for LT under ground cable any size/capacity including bracing clamp,bolts,nuts & washers. Make:- Hensel model No-KF2525B or Sintex or equivalent as approved.
M&L for replacement of steel wire rope of size 5mm dia (as per existing) with required nuts, bolts and hooks including taking down old unserviceable steel wire rope from different high mast towers.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
M&L old size brick class 'B' as in cable protection laid dry, flat, transversally along the length of cable on sand cushioning with width equal to length of the brick complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal etc. including necessary formwork and fair finishing to exposed surface without using extra cement complete all as specified and directed.
M&L for cement concrete (1:3:6) type C2 using 40mm graded crushed stone aggregates for foundation of poles / struts / stays / fencing post etc complete all as specified and directed.
S&F in replacement of steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolt, nut and screws as specified 410 SP-55 (9 mter long) including taking down old damaged pole of any type and size, including one coat of red-oxide zinc chrome primer and two coats aluminium paint on surfaces, exposed to view and making 30cm wide strips (Total 5 Nos) with yellow and black paint alternately on external surface, above PCC benching including with writing of pole No with letters/figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm after painting complete all as specified and directed.
Material and labour for prepration of old concrete surface of HT poles, 11 metres high including PCC coping, removing old paint particles and apply two coats of cement base paint on the surface of pole and PCC coping, applying two coat of aluminium paint on cross arms, bracing, supports, clamps, eye hooks, security light bracket clamp etc and marking black and white strips with synthetic enamel paint, 30 cm wide, alternatively upto 1.5 mtr above the coping of pole starting with black strip complete, all as specified and directed. Note. (i) The quoted rate shall include marking of numbers on each HT pole as per direction of Engr in-Charge. (ii) The quoted rates includes the cost of repairing of coping in cement mortar 1:3 finishing surfaces even and smooth without using extra cement.
Trimming of tree branches from LT overhead line to branch 2 mtr up to both side & re-stretching of ACSR conductor and earth wire of any size and type on LT poles including disconnecting and rebinding with insulators with suitable size of binding wire after restretching, connecting jumpers, adjusting line deviders and disposal tree branches as per direction by Engr-in-Charge complete including removing and refixing of UG cable /service wires to the ACSR conductor complete. Note:- Pole to pole length shall be measured and paid as one run
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 50sq.mm 3.5 core including taking out old unserviceable cable complete all as specified and directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 35 sq.mm 3.5 core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 25 sq.mm 3.5 core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 16 sq.mm 4 core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 10 sq.mm 4 core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 16 sq.mm 2 core including taking out old unserviceable cable complete all as directed.
Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated, armoured electric cable with aluminium conductor ,cross-sectional area 10 sq.mm 2 core including taking out old unserviceable cable complete all as directed.
S&F 50mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
M&L 25X20cm size HT danger notice plate of 1.60mm thick mild steel sheet,vitreous enamelled white,with letters,figures and conventional skull and bones in single red colour and fixed with M.S clamps,bolts and nuts including taking down existing rusted danger notice plate complete all as specified and directed.
Cutting and removing existing wild grass, vegetation, creepers, small plants / bushes etc clamping up towards the poles and stays etc including cleaning bottom surface area of pole & stay not less than 1m x 1m by surface dressing of earth outside and inside sub stations, perimeter fencing around pump house area, and in drains surrounding area from site complete all as specified and directed.
Supply and spreading graded crushed stone aggregate 40mm size around two pole/ four pole structure in 15 cm thickness after cleaning area by removing existing wild grass, vegetation, creepers, small plants/bushes etc complete all as specified and directed.
M&L for disconnecing, taking down and stacking the unserviceable /broken earth wire /strip of any size from the roof or from wall and removing the same from the site complete all as directed.
S&F in replacement air termination vertical type, single pointed made with 12mm dia 300mm long aluminium rod including necessary fixing arrangements with aluminium bolts, nuts, lead wasters etc. complete and incl provisin of GI tubing light grade 40mm dia, 300mm long embedded in PCC block (size 30cm x 30cm x 30cm) one end and other end fitted with air termination rod all as specified and directed.
S&F horizontal/down conductors aluminium strip of size 25mm x 3.15mm and including epoxy insulator bus bar type 40mm thick at an interwal of 60cm apart for lightening protection on roof and for down conductors, including all fixing arrangement sand aluminiun nut, bolt & washers complete all as per IS-2309-1989 and testing all as specified. Note:- Aluminium strip shall be jointed with rivets minimum 4 Nos.
S&F in replacement test point terminal block madeout and gun metal or phosphorus bronze of size 75mm x 75mm x 25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hexagonal head screw for fixing the same on wall as as directed at site.
S&F galvanised from strip of size 32mmx 6mm from earth pit to test point provided all around the bldg for lightening protection laid in trenches/fixed to walls on epoxy insulators with screws etc and connecting up complete all as directed..
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead strip 32mm x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc including taking out old un-serviceable earthing, complete all as directed.
Note:-(i) The concrete pit shall be of PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-I. (ii) Item includes the cost of GI pipe up to 7.5m GI for protection of earth strip. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
M&L monthly Inspection, maintenance and serviceing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed as specified for the following DG sets :- (a) 62.5 KVA Capacity, Make: Cummins, - 03 Nos (b) 40 KVA Capacity, Make: Cummins-03 Nos (i) Checking engine oil level and topping up as and when required. Note:-(i) Oil shall be measures and paid separately (ii) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid seperately. (iii)Checking of air filter element (iv) Checking of exhaust system for leakage (v) Draining of sediment from fuel filter and fuel tank (vi) Cleaning of air cleaner element (vii) Checking engine alternator coupling, mounting bolts and alignment (viii) Tighting all nuts, bolts, in altenator terminal block (ix) Checking of alternator carbon brush and connections in alternator (x) Checking and tighting of all connection in DC control wiring. For further Note please refer PS
Description all as per Srl item No. 43 above but DG set of capacity 75/82.5 KVA of any make.
Description all as per Srl item No. 43 above but DG set of capacity 140 KVA of any make.
Description all as per Srl item No. 43 above but DG set of capacity 250 KVA of any make.
M&L required for Inspection, maintenance and servicing of DG Sets of following Capacities including alternator, electric panel board connection to DG set for routine check (B - Check) of DG set for smooth functioning and carrying out maintanance complete all as directed and specified. Note:- (i) B-Check once in six month OR 250 Hrs running of DG set whichever is earlier. (ii) B- Check of all DG sets ones shall be paid as one Job. (iii) All spare parts required shall be measured and paid separately as supply only (a) The B check of different DG set capacity as mentioned in Srl item No. 43 to 46 are carried out in this items. NOTE :For further Note please refer PS
Supply only diesel filter (Primery & Secondary) suitable for 40 KVA DG Set
Supply only diesel filter (Primery & Secondary) suitable for 62.5 KVA DG Set
Supply only diesel filter (Primery & Secondary) suitable for 75 KVA DG Set
Supply only diesel filter (Primery & Secondary) suitable for 82.5 KVA DG Set
Supply only diesel filter (Primery & Secondary) suitable for 140 KVA DG Set
Supply only diesel filter (Primery & Secondary) suitable for 250 KVA DG Set
Supply only engine oil filter suitable for 40 KVA DG Set
Supply only engine oil filter suitable for 62.5 KVA DG Set
Supply only engine oil filter suitable for 75 KVA DG Set
Supply only engine oil filter suitable for 82.5 KVA DG Set
Supply only engine oil filter suitable for 140 KVA DG Set
Supply only engine oil filter suitable for 250 KVA DG Set
Supply only oil pressure switch of approved make for 40 to 250 KVA DG Set.
Supply only oil pressure gauge of approved make for 40 to 250 KVA DG Set.
Supply only water temperature gauge of approved make for 40 to 250 KVA DG Set.
Supply only ignition switch of approved make for 40 to 250 KVA DG Set.
Servicing and repair self starter 12 V for DG set incl replacement of parts such as corban brushes, solonaid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed. (40 to 62.5 KVA DG Set)
Servicing and repair self starter 12 V for DG set incl replacement of parts such as corban brushes, solonaid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed. (75 to 82.5 KVA DG Set)
Servicing and repair self starter 12 V for DG set incl replacement of parts such as corban brushes, solonaid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed. (140 KVA DG Set)
Servicing and repair self starter 12 V for DG set incl replacement of parts such as corban brushes, solonaid, rotor,washer, nut, bolts etc assembling the same and testing complete all as specified and directed. (250 KVA DG Set)
Dismantling the radiator and fan from the engine for cleaning of copper /aluminium tubes and cooling fins by using descaling solution (MAC solution) and soldering, patch work if required including repair of water pump assembly and replacement of defective parts of water pump and re-assembling,testing complete 62.5/40 KVA DG set complete all as specified and directed by Engineer in charge. Note:- Fan blade shall be measured seprately as supply only.
Dismantling the radiator and fan from the engine for cleaning of copper /aluminium tubes and cooling fins by using descaling solution (MAC solution) and soldering, patch work if required including repair of water pump assembly and replacement of defective parts of water pump and re-assembling,testing complete 75/82.5 KVA DG set complete all as specified and directed by Engineer in charge. Note:- Fan blade shall be measured seprately as supply only.
Dismantling the radiator and fan from the engine for cleaning of copper /aluminium tubes and cooling fins by using descaling solution (MAC solution) and soldering, patch work if required including repair of water pump assembly and replacement of defective parts of water pump and re-assembling,testing complete 140 KVA DG set complete all as specified and directed by Engineer in charge. Note:- Fan blade shall be measured seprately as supply only.
Dismantling the radiator and fan from the engine for cleaning of copper /aluminium tubes and cooling fins by using descaling solution (MAC solution) and soldering, patch work if required including repair of water pump assembly and replacement of defective parts of water pump and re-assembling,testing complete 250 KVA DG set complete all as specified and directed by Engineer in charge. Note:- Fan blade shall be measured seprately as supply only.
Supply & fix in replacement of unserviceable battery 12 V, 100 AH with maintenance free battery 12 volt initially charged. Make:- EXIDE / AMRON / LUMINOUS
Supply & fix in replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 volt initially charged. Make:- EXIDE / AMRON / LUMINOUS
Supply only battary charger of 12 V in AMF panel of approved make.
Supply only battary charger of 24 V in AMF panel of approved make.
Supply only battery terminal heavy duty of brass with nuts and bolts of approved make.
Supply only Distilled water of approved make.
Supply only coolant for raditor of approved make.
Supply only 20W 40 / 15 W 40 turbo synthetic superior quality engine oil Make:-Kirloskar/Catrol/Volvoline/servo /HP/IOC Note:- contractor has to supply engine oil of make as recommened by DG Set manufacturer
Supply only battery lead heavy duty, multi stranded copper conductor 35 Sqmm 2.50 metres long.
Supply only fan belt of suitable size for 40/62.5 KVA DG Set compete all as specified and directed.
Supply only fan belt of suitable size for 75/82.5 KVA DG Set compete all as specified and directed.
Supply only fan belt of suitable size for 140 KVA DG Set compete all as specified and directed.
Supply only fan belt of suitable size for 250 KVA DG Set compete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in natural ground , including taking out embedded portion and making good disturbed ground complete all as specified. Note:- the vertical height above GL shall be measured for the purpose of payment towards work done
Dismantling of chain link wire mesh of any type including removing of rusted unserviceable wire mesh, flat iton, round bar MS, nuts & bolts from work site all as directed.
Excavation in post holes (or similar holes) each n.exc 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n.exc 50m and making good surface (Soft/loose soil) complete all as specified and directed.
S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 (Gde-E-165) complete all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 (Gde E-165) complete all as specified and directed.
S&F framed steel work for framed and hung as gates (consist of MS angles, channels, flat, bars, MS plates etc.), including pintle hinges, stops, rolers, hand-made sliding bolts, etc. conforming to Fe 290Gde -E-165 complete all as specified in drg or directed.
S&F in repairs galvanised stranded, steel barbed wire 2.24mm dia barbed 100RM with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including , fencing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc as directed (Each line wire to be measured)
S&F for MS flat iron fillets for securing chainlink/wire mesh including all necessary drilling, bolting or riveting etc, conforming to Fe-290, Gde E-165.
S&F Mild steel rag or lewis bolts diameter of neck in 12 mm, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, n. exc 15cm long complete all as specified and directed.
M&L mild steel 10mm dia round bars and over cut to length bent to shape required including cranking, bending shooking ends binding with and including mild steel wire not less than 0.9mm dia confirming to IS 1786 complete all as specified and directed.
Supply only chain link MS Galvanised fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type of any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed.
M&L preparation of new steel and iron surfaces of any description n.exc 10 cm width or girth and applying two coats of synthatic enamel paint over one coat of red oxide primer complete all as specified.
M&L black bituminous paint on surfaces of steel exceeding 10cm in width or girth complete all as specified and directed.
M&L preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed .
Demolition brick work or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc. but excluding ashlar facings, dressed stonework and precast concrete articles including removing of demolished material from work site complete all as specified.
M&L brick work with fly ash bricks, old size, having compressive strength 75 Kg/Sqcm, straight or curved on plan exc 6m mean radius, using old size brick, build in CM 1:4, complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc. including removing of rubbished material from work site complete all as specified.
M&L rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15 cm thickness (below or above ground level), including removing of demolished material from work site at any distance outside MD land complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in coping and benching for drain wiith slightly chamferred or rounded angles including necessary form work if any, and finishing exposed surface even and smooth without using extra cement complete all as specified and directed.
Cleaning of blockage of storm water or surfaces water drains with necessary excavation inside the drains carefully not exceeding 1.50 m wide & not exc. 1.50m in depth and getting out all silt mixed with earth and other foreign materials from inside the drains complete all as directed.
Supply and fix in replacement MCCB,AC, 415volts, 63 to 100 Amp, 16KA, 4 pole,with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
Supply and fix in replacement MCCB,AC, 415volts, 125 Amp, 16KA, 4 pole,with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
Supply and fix in replacement MCCB, AC, 415volts, 160 Amp, 35/36KA,4 pole, with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
Supply and fix in replacement MCCB, AC, 415volts, 200 Amp, 35/36KA,4 pole, with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
Supply and fix in replacement MCCB, AC, 415volts, 250 Amp, 35/36KA,4 pole, with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
Repair/maintenance including complete servicing of mechanical laundry machine installed in MH Palampur with replacement of unserrviceable/defective parts like heating coils, dampner springs, drying tumbler, fan belts, thermostat switch, relay capacitor, over load protector, starting knobs etc. rewiring if required for the system, oiling, greasing including replacement of ball bearing to the motor for smooth functioning of the plant complete all as specified and directed.
S&F in replacement of unserviceable 12 Volts, 75 Ah dry type, maintenance free battery suitable for solar street lights including necessary welding work to battery box as required at site complete all as specified and directed. Make: Exide/Amaron/Luminous or any equivalent make as approved.
S&F in replacement of unserviceable 12 Volts, 150 Ah dry type, maintenance free battery suitable for solar street lights including necessary welding work to battery box as required at site complete all as specified and directed. Make: Exide/Amaron/Luminous or any equivalent make as approved by GE.
S&F in replacement of old unserviceable aluminium body Red Aviation Obstruction lights, double dome type suitable for RCC OH Reservoir with retrofit type LED lamp complete all as specified and directed. Make: Bajaj/Philips/Baliga or equivalent make as approved by GE.
S&F in replacement of old unserviceable aluminium body Red Aviation Obstruction lights, single dome type suitable for High mast structure with retrofit type LED lamp complete all as specified and directed. Make: Bajaj/Philips/Baliga or equivalent make as approved by GE.
M/s Sheetal Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .