Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC VIKASH NAGAR GAUSHALA RAMGARH CANTT 829122 RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC QUOTED AMOUNT IS LOWEST AND RESONABLE | |
| 2 | L2₹31.0 L+₹45,099 (1.48%)Rejected-Finance | L2 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND RESONABLE | |
| 3 | L3₹32.3 L+₹1.7 L (5.72%)Rejected-Finance | L3 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND RESONABLE | |
| 4 | L4₹40.0 L+₹9.5 L (31.1%)Rejected-Finance 02 RUDIA BIT MESRA ROAD NEORI VIKAS RANCHI JHARKHAND 835217 | RANCHI | JHARKHAND | 835217 | L4 | Rejected-Finance QUOTED AMOUNT IS NOT LOWEST AND RESONABLE | |
| 5 | Rejected-Technical 1 HHBS AND CO PROTHRAPUR ANDAMAN AND NICOBER PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | - | Rejected-Technical Rejected due to adverse remarks in WLR |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
22 Apr 2024, 6:00 pmClosed
GARRISON ENGINEER
RAMGARH CANTT
Rep main to LT OH line UG cable panel bd with connected work centrifugal pump submersible pump floculator chemical dosing connected item deep freezer refg AC water cooler geyser ceiling fans exhaust fans air circulator desert cooler at Ramgarh Cantt
2024_MES_646219_1
8300/3231/E8
Open Tender
Civil Works
Item Rate
180 days
RAMGARH CANTT
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE RAMGARH CANTT
₹80,000
Yes
12 Jul 2024
13 Mar 2024
29 Apr 2024
13 Mar 2024
22 Apr 2024
8 Apr 2024
Amount
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations, shafts, well, cesspits, manholes etc.complete all as specified and directed.
Removal of surplus excavated spoil not exceeding 50 mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
Supply and spreading clean, dry, fine river sand for under ground electric cable in two layers (8cm thick before laying of cable & 15cm thick after laying cable to a total of 23cm) including gentle punning the sand upto 18cm (total thickness) and consolidated around cable for protection of UG cable complete all as specified and directed. NOTE:- For measurement purpose punned thickness shall be considered as per clause 19.75 of SSR Part-I.
Supplying and laying old size sub class “B” bricks kiln brunt, neatly laid adjacent to each other with axis of bricks perpendicular to the axis of cable for cable protection complete all as specified and directed.
M&L for plain cement concrete 1:2:4, type B-1 (using 20 mm graded crushed stone aggregates) as in kerb/benching/ copings including weathering, slightly rounded or chamfered angle and throating including use & waste of necessary form work etc complete all as specified and directed
M&L for plain cement concrete 1:3:6 ,type C-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M&L for plain cement concrete 1:4:8 ,type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete for fencing posts, foundation of pole ,struts & stay assembly etc complete all as specified and directed.
M & L for brick work using old size well burnt brick with subclass 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 25 Sq mm 4.0 core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including connecting & testing complete all as specified and directed by Engineer-in Charge. (Note: sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 35 Sq mm 3.5 core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including connecting& testing complete all as specified and directed by Engineer-in Charge. (Note: Sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 50 Sq mm 3.5 core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including connecting& testing complete all as specified and directed by Engineer-in Charge. (Note: Sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 70 Sq mm 3.5 core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including connecting& testing complete all as specified and directed by Engineer-in Charge. (Note: Sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Disconnecting & removing 1100 volt grade XLPE /PVC armoured electric power cable (heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 95Sq mm 3.5 core from the trenches ,pole,Panels,DBs etc carefully and relaying the same with same location without any damage to the cable by excavation in trenches carefully as per standard procedure including connecting& testing complete all as specified and directed by Engineer-in Charge. (Note: Sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 95 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 70 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 50 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 35 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 25 Sq mm 4 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sq mm 4 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 16 Sq mm 2 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.) (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 10 Sq mm 2 core including taking down old unserveciable cable complete all as specified and directed. (Note: Excavation ,earth work ,sand cushioning,bricks for cable protection,GI protection pipe shall be measured and paid separately under respective of BOQ.)
Supplying and fixing as in replacement MCCB four pole 100 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 125 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 160 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 200 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 250 amps 415 volt , 50 Hz breaking capacity not less than 25 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 315 amps 415 volt , 50 Hz breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 400 amps 415 volt , 50 Hz breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Supplying and fixing as in replacement MCCB four pole 630 amps 415 volt , 50 Hz breaking capacity not less than 36 KA with thermal magnetic release, adjustable thermal and adjustable magnetic setting with spreader links Ics=100 % of Icu complete all specified and directed by Engr-in-Charge.
Dismentling old and unserveciable stay assembly complete comprising of stay clamp, stay wire, stay insulator, stay grip, thimble, bow, stay rod 16 mm dia and stay plate etc including breaking of cement concrete complete all as specified and as directed.
M&L for stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps excavation and concrete measured separately), stay rod of size 20mm dia complete all specified and directed .
Supply and fixing in repairs loop type insulators, vitreous porcelain, white, brown or greeen of large size, with over all dimensions 90 mm X 140 mm, clearance of hole 25.5 mm complete all as specified and directed.
Dismantling old and unserveciable pre-stressed concrete poles/steel tubular poles of any type or any description including breaking cement concrete complete all as specified and directed.
Supply and erection of steel tubular pole swaged type 410-SP -37 (09.50 mtr long pole) complete conforming to IS: 2713 complete with mild steel base plate, finial taper plug pole cap, mild steel bolt, nuts and screws,painting of pole externally with one coat of black bituminous paint (upto planting depth) and remain exterior portion of the pole shall be painted with two coats of aluminium paint over a coat of primer with blue & white strip upto 1.20 m height above GL and all as specified and directed with two coat of aluminum paint over a coat of red oxide primer including preparation of surface including painting of 30 cm wide bands 5 Nos with yellow and black paint of radium/photosinthetic paint alternately on external surface above base / coping upto the height of 1.5mtr above plinth block,writing letter or figures (Block Roman) with thick synthetic enamel paint of approved shade not exceeding 5 cm height including numbering of pole, Painting coping with two coats of cement based paint etc complete all as specified and directed. NOTE : (i) All excavation and earthwork ,PCC shall be measured and paid separately under respective items of BOQ. (ii) Manufacture's test certificate for pole shall be produced before execution work.
M&L for painting to existing steel tubular/concrete LT poles, 8.5m/9m/9.5m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality dust proof and weather proof of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint of radium/photosinthetic paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete and writing pole numbers with bold letters with black and white paint after painting complete all as specific and as directed.
Supply and laying GI pipe 80 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.
Supply and laying GI pipe 50 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.
Supply and laying GI pipe 40 mm bore light grade with fitting for cable protection at road crossing/under concrete including taking down of old one complete all as specific and as directed.
Dismantling and removal of Aluminium conductor, steel reinforced (ACSR) conductor any size from the pole and labour for restringing the same with insulator including replacement of binding wire, aluminium jumper, etc chopping of trees branches (coming in the way/line) complete all as directed by Engr-in-Charge. Note : The unit rate quoted by bidder is deemed to be included the T&P cost like rope manila,ladders etc required at site
S & F in repair ACSR (Aluminium conductor, steel reinforced) conductor of (weasel) 6/1 X 2.59mm, streching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge
Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specific and as directed.
M & L for Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4mm dia complete all as specific and as directed.
S & F in repair Aluminium thimbles of size 16 Sq mm to 35 Sqmm of 3.5 core /4 core and including removing burnt thimbles from existing XLPE Cables & cable made to suitable for fixing new thimbles complete all as specified and directed.
S & F in repair Aluminium thimbles of size 50 Sq mm to 95 Sqmm of 3.5 core /4 core and including removing burnt thimbles from existing XLPE cables & cable made to suitable for fixing new thimbles complete all as specified and directed.
S & F in repair Aluminium thimbles of size 120 Sq mm to 185 Sqmm of 3.5core/4 core and including removing burnt thimbles from existing XLPE Cables & cable made to suitable for fixing new thimbles complete all as specified and directed.
M&L for Pin type Porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65 mm dia for 1100 volts grade including dismantling /disconnecting & taking down of existing insulaters of any size & capacity complete all as specified and directed.
M & L shackle type porcelain, vitreous, white, brown or green Two-in-series' assembly for tension with tension clamps for conductors, working pressure 1100 volts insulator 65 mm dia X 31 mm high X 20mm hole ball and socket type working pressure 1100 volts grade including dismantling /disconnecting & taking down of existing insulaters of any size & capacity complete all as specified and directed.
S & F in repair cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminum paint complete all as specified and directed.
Material and labour for Fibre LT over head line seperators suitable for 4 wires fixing on LT OH lines including dismantling of old damaged/ un-serviceable LT line spacers of any type complete all as specified and directed.
Material and labour for Fibre LT over head line seperators suitable for 2 wires fixing on LT OH lines including dismantling of old damaged/ un-serviceable LT line spacers of any typecomplete all as specified and directed.
Supply and fix in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with mild steel clamps, bolts and nuts of approved size 20 cm x 15cm for LT complele all as specified and as directed.
Cutting branches /plants / bushes obstructing (any size or any girth) at over head LT/HT lin including cleaning /levelling / cutting of undue surfaces & disposal of materials upto a distance not exceeding 50m complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth wire of size 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing testing point all as specified and directed including excavation and connected earth work in hard/dense soil, PCC 1:3:6 ,type C-1(using 20 mm graded crushed stone aggregate ) as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm dia bore GI light grade pipe as earth lead protection pipe, 50 mm thick pre-cast RCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate ) as in cover slab of size 300 mm x300 mm x 50mm as earth pit cover slab with & including 8 mm dia TMT bars @ 100 mm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing on completion includingdismantling/taking down of old unserveciable earthing complete all as specified and directed. Note- Unit rate quoted by bidder deemed to be included excavation and earth work in any type of soil with other arrangement complete all as directed.
M& Lfor Earthing complete with GI earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI earth strip of size 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to LT panel boards all as specified and directed including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1(using 20 mm graded crushed stone aggregate ) as in pit, 20mm dia GI pipe medium grade for watering pipe, 40 mm dia bore GI light grade as earth strip protection pipe, 50 mm thick pre-cast RCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate ) as in cover slab of size 300 mm x300 mm x 50mm as earth pit cover slab with & including 8 mm dia TMT bars @ 100 mm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing on completion includingdismantling/taking down of old unserveciable earthing complete all as specified and directed. Note- Unit rate quoted by bidder deemed to be included excavation and earth work in any type of soil with other arrangement complete all as directed.
Supply only 3.15 mm thick mild steel sheet alongwith one coat of red oxide primer with help of spary gun machine complete all as specfied and directed.
Supply only aluminium bus bar of different size and different capacity, as per site requirement and as directed by Engineer-in-Charge including PVC insulating materials and cutting, welding as required, making holes and fixed in position in replacementt (taking down old bus bar) complete all as specified and as directed.
Supply only post top insulators of 3 to 5 cm height for panel boards complete all as specified
Supply only digital Amps meter 0 to 600 Amps capacity 3 phase square type including suitable CT set of 3 old complete all as specified and as directed.
Supply only digital volt meter 3 Phase 415 volt square/round type range 0-500 volt complete all as specified and as directed.
Supply only LED indication Lamp (Red) complete all as specified and as directed.
Supply only LED indication Lamp (Yellow) complete all as specified and as directed.
Supply only LED indication Lamp (Blue) complete all as specified and as directed.
M & L for removing of damaged steel structure base frame of LT panel board and fabricating new steel structure base frame with size of existing frame equal angle of size 50 mm X 50 mm X 6 mm thick and screwing with existing panel board including two coat of synthetic enamel paint over a coat of red oxide primer with preparation of surface complete all as specified and directed.
Removing wild grass, vegetation, creeper etc around LT panel/ installations, climbing up towards poles and stay assembly including cleaning bottom surface of pole, stay assembly of area not less than 1m x 1m by surface dressing not exceeding 0.5 m deep in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Taking down centrifugal pump set from existing position for carrying out repair works,replacement of spare parts as & when required as directed by Engineer -in Charge and re-assembling, re-installing the pump set in original position for pump capacity 1.0 HP/1.5 HP/2.5 HP complete all as specified and directed.. Note: Spare parts, as & when required for renewal shall be measured and paid separately.
Taking down centrifugal pump set from existing position for carrying out repair works,replacement of spare parts as & when required as directed by Engineer -in Charge and re-assembling, re-installing the pump set in original position for pump capacity 60 HP/50 HP complete all as specified and directed.. Note: Spare parts, as & when required for renewal shall be measured and paid separately.
Dismantling and opening the motor from pump set in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding by carrying the motor to outside the cantonement area, reassambling and refixing the same with pump in original position for the 1.0HP/1.5HP/2.5 HP, 3 phase complete all as directed by Engr-in-Charge.
Dismantling and opening the motor from pump set in existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding by carrying the motor to outside the cantonement area, reassambling and refixing the same with pump in original position for the 60 HP/50 HP, 3 phase complete all as directed by Engr-in-Charge.
Following spares parts for centrifugal pump set :-
Supply only Impeller CI, spare part, for pump set including motor complete for 50 HP centrifugal pump, complete all as directed.
Supply only Pump shaft spare part for pump set including motor complete for 50 HP centrifugal pump, complete all as directed.
Supply only Neck ring spare part for pump set including motor complete for 50 HP centrifugal pump complete all as directed.
Supply only Shaft Sleeve spare part for pump set including motor complete for 50 HP centrifugal pump complete all as directed.
Supply only Bearings as per sample spare part for pump set including motor complete for 50 HP centrifugal pump, complete all as directed.
Dismantling of all electric & water connections ,lifting of submersible pump and motor including column pipe with the help of chain pulley block for pump capacity 15 HP opening of pump and motor, cleaning, servicing and replacement of spare parts where directed complete all as directed by Engr-in-Charge.
M & L for rewinding work for 3 phase submersible motor of capacity 15 HP with new PVC insulatedd super enammel copper wire of suitable gauge as per existing complete all as specified and as directed.
Supply only Impeller CI spare part for pump set including motor complete for 15 HP submersible pump set, complete all as directed.
Supply only Neck ring spare part for pump set including motor complete for 15 HP submersible pump, complete all as directed.
Supply only Bearing top as per sample spare part for pump set including motor complete for 15 HP submersible pump, complete all as directed.
S & F in repair for nut, bolt and wahers of suitable sizes for fixing in different parts of pump and motor, complete all as specified and as directed.
S & F in repair water proof un armoured multistranded copper cable 70 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.
S & F in repair water proof un armoured multistranded copper cable 50 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.
S & F in repair water proof un armoured multistranded copper cable 35 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.
S & F in repair water proof un armoured multistranded copper cable 25 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.
S & F in repair water proof un armoured multistranded copper cable 10 Sqmm, single core, 3 phase, 440 volts, complete all as specified and as directed.
S&F in repair tyre coupling of series F 80 suitable for 50HP/60 HP centrifugal pumping set complete all as specified and as directed.
S&F in repair tyre coupling of series F 90 suitable for 50HP/60 HP centrifugal pumping set complete all as specified and as directed.
S&F in repair tyre coupling of series F 100/F 110 suitable for 100 HP centrifugal pumping set complete all as specified and as directed.
S&F in repair Rubber star coupling of suitable sizes for fixing in pump, complete all as specified and as directed.
S&F Copper thimbles of size 25 Sqmm to 50 Sqmm of single core and including removing burnt thimbles from existing copper cables and cable make to suitable for fixing new thimbles complete all as specified and directed.
S & F in repair DOL Starter suitable for 3 HP suitable for 2.5/3HP monoblock centrifugal pumping set for cleaning compressor of Iron Removal Plant(IRP), complete all as specified and as directed.
M&L for spray painting to exposed surfaces of centrifugal pumping set of any capacity and size with a coat of synthetic enamel anti corrosive and dust free paint,(as per existing colour) including preparation of old painted surface by scraping of old paint, filling cavities with filler and writing MES/SM No. over painted, complete all as specified and directed.
M&L for spray painting to exposed surfaces of GI/CI pipe line of any size with one coat of synthetic enamel dust and weather proof paint of approve make,(as per existing colour) including preparation of old painted surfaces of pipes,by scraping & removal of rusting to the pipes, filling cavities with filler, complete all as specified and directed.
Taking out old burnt compressor and S & F new sealed /rotary compressor suitable for 1.5 tonne capacity of window/split type AC unit and connecting up suction and discharging pipe line with gas welding and duly charged with fresh refrigents gas connecting up all electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Make :Voltas/USHA/Shriram/ Blue Star/ Samsung / Hitachi/Vedeocon/LG /Carrier /General/Onida etc as per existing make at site.
Taking out old burnt compressor and S & F new sealed /rotary compressor suitable for 2.0 tonne capacity of window/split type AC unit and connecting up suction and discharging pipe line with gas welding and duly charged with fresh refrigents gas connecting up all electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Make :Voltas/USHA/Shriram/ Blue Star/ Samsung / Hitachi/Vedeocon/LG/Carrier/General/Onida etc as per existing make at site.
Material & Labour for replacement of rusted body portions of split type AC/Window type AC unit of 1.5 tonne /2.0 tonne capacity with same gauge / size materials like mild steel sheet, angle iron similar to the existing one by removing existing, foam pad and components and scraping out old paint on complete body, cleaning surface thoroughly, appling two coats of synthetic enamel paint of approved shade over a coat of red oxide primer including preparation of existing surface,fixing of new foam pad of not less than 3mm thick, refixing of all components, installation in original position, connecting up all electrical connections, testing and commissioning all as specified and directed.
S & F for condenser fan blade set for 1.5/2.0 Ton capacity of any type of ACs, suitable for existing makes and rotation in the casing testing including taking out the defective condenser fan blade complete all specified and directed.
M&L for Evoporator fan blower motor of suitable capacity duly ISI marked, double inlet, double width centrifugal type suitable for 1.5/2.0 Ton capacity split type AC including taking down the unserviceable damaged Evoporator fan blower motor complete all as specified and directed.
M&L for painting of split type AC and window type AC by applying two coats of approved synthetic enamel paint over a coat of red oxide primer for any capacity of ACs including preparation of old surface by scrapping and removing of old corroded paint complete all as specified and directed by Engineer-in-charge.
M&L for Single pole contactor for 1.5/2.0 ton capacity of split type ACs including taking down of existing contactor complete all as specified and directed.
M&L for replacement of thermal insulation for 1.5/2.0 Ton split type ACs complete all as specified and directed.
M&L for Themal over load relay for 1.5/2.0 Ton capacity of any type of ACs including taking down unserviceable thermal over load relay complete all as specified and directed.
M &L for Running capacitors of 35 mfd to 60 mfd suitable for 1.5/2.0 Ton Capacity split type AC/window type AC including taking down existing unserviceable running capacitors complete all as specified and directed.
M&L for Starting Capacitor of 80/100/120 MFD suitable for 1.5/2.0Ton Capacity split type AC/Window type AC including taking down old unserviceble staring capacitor complete all as specified and directed.
M & L in repairs for Drain connection and drain trap for 1.5/2.0 Ton capacity of split type ACs complete all as specified and directed.
M&L for capillary tube set suitable for 1 5/2.0 ton capacity of split type AC including taking down of existing unserviceable defective capillary tube set all as specified and directed.
M&L for replacement of rusted mild steel stand (size & shape of existing stand) suitable for mounting out door unit of split type AC over & including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for servicing carefully any type of AC of cap 1.5/2.0 TR from site and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, cleaning, servicing including chemical wash of cooling coil of indoor cooling unit and condenser coil of out door unit and cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas and re assembling the dismantled components and fixing to its original position complete all as specified and directed.
M&L for shifting of Split AC of 1.5/2.0 TR capacity including removing indoor cooling machine, copper piping, drain pipe and thermal sleeve, lifting angle with necessary re-fixing arrangement on wall surface, copper piping of suitable gauge for suction and delivery with insulation, including re-surfacing to disturbed surface and testing and commissioning all as specified. (Note: The copper pipe required will be measured against relevent items in this schedule)
M & L for gas charging with refrigerant gas R-22, R-34 & R-410 in new sealed/eixting unit of compressors ACs/Water cooler/Deep freezer/Refrigerator unit of any type and any size including testing, complete all as specified and as directed by Engineer-in-charge.
S & F new temperature sensor probes in the main circuit of split type AC including removal /taking down of existing temperature sensor probes complete all as specified and as specified.
S & F in repair Printed Circuit Board (PCB Board) for any type of AC units suitable for 1.5 TR to 2.0 TR, complete all as specified and as directed by Engineer-in-charge. Make : Voltas/ Videocon /LG/National aircon/Bluestar/Carrier as approved by GE
S & F in repair remote controller unit suitable for split type ACs/widow type AC unit of 1.5/2.0 Ton capacity complete all as specified and as directed.
S & F in repair for PVC drain pipe of 15mm/20 mm dia with suitable clamps on walls and ceiling all as specified and as directed.
S & F in repair cooling coil of 1.5/1/2 ton AC units including necessary welding/brazing of copper pipes line, testing of leakage, complete all as specified and as directed by Engineer-in-charge.
M & L for repairing of cooling coil,cooling fan ,out door motor ,out door condenser coil for walk in cooler complete all as specified and as directed. Note:Minor spares required for repairing is deemed to be included in the unit quoted rate.& not any claim entertained on this account at later stage.
S & F new air filter for AC of any size including removal /taking down of existing air filter complete all as specified and as directed by Engineer-in-Charge.
M & L for PVC cable 4 Sqmm, 3 core unsheathed multi stranded copper conductor including taking down of existing cable complete all as specified and as directed by Engineer-in-Charge.
S & F strainer filter for AC including removal /taking down of existing strainer filter complete all as specified and as directed by Engineer-in-Charge. Make : Voltas/LG/Godrej/Bluestar/Kirloskar/Carrier or equivalent as approved by GE.
S & F in repair copper pipe as per existing size/shape including necessary welding/brazing/making threading required length, complete all as specified and as directed by Engineer-in-charge.
S & F in repair air grill for split AC as existing size/shape/design & make, complete all as specified and as directed by Engineer-in-charge.
Taking down unserviceable water cooler from the site and transporting the same for repair,removing the unserviceable burnt sealed unit (compressor) from the water cooler and S&F factory overhauled compressor duly charged with compressor oil including welding in position and testing on required pressure and transporting the water cooler at site in its original location of capacity 40/80 ltr complete all as specified and as directed by Engineer-in-charge. .
S & F in replacement of running capacitor for water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-charge.
S & F in repair starting capacitor for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-charge.
S & F in replacement of starting relay 3 pin for water cooler 40/80 ltrs capacity complete all as specified and as directed by Engineer-in-charge.
Taking down old defective over load protector and S&F new over load protector of suitable capacity/size for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-charge.
Taking down rusted front and back body mild steel sheet cover and S&F new 2mm thick mild steel plate cover( existing size)of duly painted to match the existing of water cooler complete all as specified and as directed by Engineer-in-charge. .
S & F in replacement of unserviceable float valve with new polythelene ball suitable for 15mm dia of GI pipe complete all as specified and as directed by Engineer-in-Charge.
Taking out old unserviceable 15mm dia water tap and S&F new self closing chromium plated push cock of 15mm dia heavy duty complete all as specified and as directed by Engineer-in-Charge.
Taking out old unserviceable fan motor and S&F new fan motor suitable for water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-Charge.
M&L for cleaning of water cooler complete internally and externally including scraping and complete removing of existing treatment, scales and dirt etc.and applying of two coats of synthetic enamel tone paint over a coat red oxide primer all as specified and as directed.
Taking down unserviceable refrigerator of capacity 250 Ltr to 310 ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt sealed unit (compressor) and supply and fix factory overhauled compressor duly changed with compressor oil including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and directed by Engineer –in-Charge.
Taking down unserviceable refrigerator of capacity 165 Ltr to 190 ltr from the site and transporting the same to work shop for repair/removing unserviceable burnt sealed unit (compressor) and supply and fix factory overhauled compressor duly changed with compressor oil including welding in position and testing on required pressure and transporting back to its site and fix in original location complete all as specified and directed by Engineer –in-Charge.
S & F in replacement of unserviceable tray with new as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of fruit/vegetable tray as per original complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of ice chamber as per the existing complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of pgmy lamp (bulb) as per the existing complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of over load relay as per the existing complete all as specified and directed by Engineer -in-Charge..
Opening of regrigator of any capacity for servicing and refixing the same after flushing out and removal blockage, brazing replacement of liquid line filter and recharging the regrigation gas R-22 to obtain the desired cooling complete all as specified and directed by Engineer -in-Charge.
M&L for spray painting of refrigerator with synthetic enamel paint after preparation of old surface of refrigerator capacity 310/286/165 ltr of any make/model complete all as specified and directed by Engineer -in-Charge.
Taking out deep freezer of any capacity from the site for complete servicing of Deep freezer units by electically disconnecting the units and cleaning the compressor , condenser , piping suction/discharge suction, fan motor, cooling coils, cooler body and connected accessries with the help of blower unit , cleaning the same with water and caustic soda for condenser and piping unit , tighten all nuts , bolts, screws etc checking the door bedding , electrical controls of the cooling units rectify where necessary and refixing in its original site and testing comlete all as specified and directed by Engineer-in-charge
S & F new sealed unit compressor for deep freezer as per existing make and size & capacity as approved by GE complete all as specified and as directed by Engineer-in-charge.
S & F running capacitor 10 mfd including taking out capacitor complete all as specified and as directed by Engineer-in-charge.
S & F in repair fan motor for deep freezer complete all as specified and as directed by Engineer-in-Charge.
S & F in repair over load relay for deep freezer as per sample complete all as specified and as directed by Engineer-in-Charge.
M & L for body patching including denting at certain place of deep freezer and then spray painting with match of existing finishing complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Voltage stabiliser, copper wound of 5 KVA capacity digital display type having I/P Correction Range of 140 - 280 volt complete all as directed.
Disconnecting carefully water and electric connection from storage type water heater of 25/50 Ltr capacity of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by de-scaling with chemical compound including soldering, brazing the inner tank if required, re-assembling the geyser after cleaning & servicing including replacement of flexible cable of size 2.5 sqmm 3 core with copper conductor up to 1.5 mtr long and re-fixing in existing position complete all as specified and directed. Note:- The rate quoted is deemed to include cost of soldering/brazing work and glass wool superior quality if required at site.
S & F in repair heating element including rubber gasket & washer etc. of capacity 1.5 KW suitable for existing make and shape all as specified and directed.
S&F Thermostat including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 /35/ 50 ltrs including taking down existing unserviceable thermostat complete all as specified and as directed.
M&L for preparation of surface of geyser 25 Ltrs /35 Ltrs /50Ltrs capacity by scrapping and applying one coat of sythetic enamel paint of approved colour including tinkering and welding if required at site all as specified and directed.
S&F PVC connecting pipe 18" long with brass adopters for hot and cold water and connecting up with complete for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and directed.
S&F base assembly complete with inlet, out let, thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly complete all as specified and as directed.
S &F in replacement inner stainless steel dome of geyser of capacity 25 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge.
S & F in replacement inner stainless steel dome of geyser of capacity 35 Ltrs complete as per sample to match original patterns and shape complete all as specified and as directed by the Engineer -in Charge.
S&F indication lamp for 25/35/50 ltrs capacity Geysers including taking down existing unserviceable indication lamp complete all as specified and as directed.
S & F in repair Plug Top 15A, 230 Volt, AC complete all as specified and directed by Engineer-in-Charge.
Taking down carefully by disconnecting electrical connection of unserviceable ceiling fans/exhaust fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/overhauling and refixing/ re-installation of repaired/serviceable fans (taken from MES store yard) to the different locations in cantt area complete all as directed by Engineer-in-charge. Note : Transportation of ceiling fans/exhaust fans from site location to MES store yard & back( MES store yard to site location )shall be made through proper issue/receipt voucher duly mentioning by MES rep.
Servicing ceiling fans of 1200mm/1400mm/ any sweep and size for repairing/ overhauling by cleaning/greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) complete all as directed by Engineer-in-charge.
Supply only ball bearing SKF 6202/6201/equivalent suitable for 1200/1400 mm sweep ceiling fans complete all as specified.
Supply only Gun Metal bush suitable for 1200/1400 mm sweep ceiling fans complete all as specified.
Servicing exhaust fans of 450 mm /300 mm/225 mm /any sweep and size for repairing/overhauling by cleaning/greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after) complete all as directed by Engineer-in-charge.
M&L for cutting of existing winding of ceiling fans of 1200 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive.
M&L for cutting of existing winding of ceiling fans of 1400 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive.
M&L for cutting of existing winding of exhaust fans of 450 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge.
M&L for cutting of existing winding of exhaust fans of 300 mm/250 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge/concerned ground executive.
S &F in repair 2.5 mfd capacitor suitable for ceiling fans of 1200 mm/1400 mm sweep of approved make complete all as specified & directed by Engineer-in-charge.
S &F in repair 4 mfd/6 mfd capacitor suitable for exhaust fans of 300 mm to 450 mm sweep of approved make complete all as specified & directed by Engineer-in-charge
S &F in repair mild steel clamps of suitable size & shape with rubber reel, nut bolts with washer and including spliting pin suitable for 1200 mm/1400 mm sweep of ceiling fans complete all as specified & directed.
S &F in repair down rod for hanging of ceiling fan, fabricated /made out of 15mm dia heavy grade mild steel conduit (length of conduit not less than 550 mm long & wall thick ness not less than 1.6 mm) with suitable fan clamps duly painted with two coat of synthetic enamel (white shade) paint over a coat of primer complete all as specified & directed.
S &F in repair down rod for hanging of ceiling fan, fabricated /made out of 15mm dia heavy grade mild steel conduit (length of conduit not less than 1250 mm long & wall thick ness not less than 1.6 mm) with suitable fan clamps duly painted with two coat of synthetic enamel (white shade) paint over a coat of primer complete all as specified & directed.
S &F in repair mild steel hooks fabricated/made out of flat iron 50 mm x 6mm including nut, bolts (6-8 mm dia & 40 to 50 mm long with spring washer) duly painted complete all as specified & directed by Engineer-in-charge.
S &F in repair PVC flexible wire of size 23/.0076 Sqmm or 0.50 sqmm multi stranded, twin core, PVC sheathed copper conductor complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove only dust etc. and applying one coat of synthetic enamel (white shade) paint and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old rusted surface of exhaust fans of any sweep by cleaning to remove only dust etc. and applying one coat of synthetic enamel (brown shade) paint and marking MES number with non erasable marker pen with black colour all as directed by Engineer-in-charge.
S & F in repair stepped socket type electronic fan regulator flush type complete all as specified and as directed.
S&F louvers for Exhaust Fan of size 250 mm to 450mm sweep steel suitable for existing shape and size including taking down existing unserviceable /rusted louvers complete all as specified and as directed by Engineer in Charge.
S & F in repair blade set suitable for ceiling fan 1200 mm/1400 mm sweep of any make as per site requirement complete all as specified and as directed.
S & F in repair metal blades set suitable for exhaust fan 300 mm/450mm sweep any make as per site requirement complete all as specified and as directed.
S & F in repair PVC blades set suitable for exhaust fan 300 mm/450mm sweep any make as per site requirement complete all as specified and directed.
S & Fin repair for metal fan blades of best quality suitable for Desert Cooler of any make and size including taking out/ down unserviceable one, complete all as specified and as directed.
S&F for PVC fan blades of best quality suitable for Desert Cooler of any make and size including taking out/ down unserviceable one, complete all as specified and as directed.
S&F in repair for Front Grill Double Partition type of 20 SWG metal grill, best quality (as approved) of suitable size for Desert Cooler providing making Electric Connection to all accessories as required including taking out/ down unserviceable one, complete all as specified and as directed.
S & F in repair for motor suitable 1/7 HP, 180 watt, 3 speed for Desert Cooler, copper wounded complete and one set of lugs for mounting body including taking out/ down unserviceable one, complete all as specified and as directed.
S&F for 15 mm dia Plastic PVC distributor suitable size for Desert Cooler heavy duty with elbow, Tee, etc. fixed with bolts, nut & washers including taking out/down unserviceable one, complete all as specified and as directed.
S & F Plastic PVC Pipe( ISI mark) of 15mm bore suitable for Desert Cooler, heavy duty, including taking out/down unserviceable one, complete all as specified and as directed.
S&F running capacitor 2.5 mfd/4mfd/6mfd suitable for fan motor of Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed.
S&F Submersible water Pump suitable for Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed.
S & F for 3 Pin, 5/6 Amp Plug Top including taking out/ down unserviceable one, complete all as specified and as directed.
M&L for mild steel Desert Cooler Body fabricated/ made out of 20 SWG with powder coated including 03 Nos side shutters of fabricated/ made out of 22 SWG, (size 3 ft x 2 ft x 2ft), noise pollution control complete body including taking out/ down unserviceable one, complete all as specified and as directed. Note:If size is not available, then next higher size shall be brought by contractor at no extra cost to department and not any claim entertained on this account at later stage.
S & F in replacement cooler stand made out of equal angle iron (size 30 mm x30 mm x 3mm ) with 25 mm cross support between angle frame and both side of front and back stand legs for desert cooler with applying one coat of synthetic enamel paint over a coat of red oxide primer on exposed surface of stand complete all as specified and directed.
S&F Grass Wool Pad (as approved) suitable for Desert Cooler, heavy duty and best quality including taking out/ down unserviceable one, complete all as specified and as directed.
M&L preparing old surfaces of Desert Cooler Body by descaling, rubbing, brushing, cleaning and applying one coat of synthetic enamel paint (as approved) with spray gun machine of outer surface of cooler and inner side of tank with black bituminous paint complete all as specified and as directed.
upadhyay engineers and consultant
M/S SHAMBHU SHARAN SINGH
THE SUVASH AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .