Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC 01 203 FEACON PALACE JATIN CHANDRA ROAD RANCHI 834001 JHARKHAND INDIA | RANCHI | RANCHI | JHARKHAND | 834001 | L1 | Accepted-AOC Techno commercially accepted L1 bidder. | |
| 2 | L2₹2.7 L+₹3,640 (1.34%)Rejected-Finance BANGALI TOLA NEAR KALI MANDIR RAMGARH 829122 JHARKHAND INDIA | RAMGARH | RAMGARH | JHARKHAND | 829122 | L2 | Rejected-Finance Rejected since L2 bidder. | |
| 3 | L3₹2.8 L+₹12,740 (4.70%)Rejected-Finance BHURKUNDA BAZAR BIRSA CHOWK LAXMI TALKIES ROAD RAMGARH 829106 JHARKHAND INDIA | RAMGARH | JHARKHAND | 829106 | L3 | Rejected-Finance Rejected since L3 bidder. |
Tender Value
₹3.0 L
EMD Value
₹3,700
Closing Date
13 Mar 2024, 6:00 pmClosed
Staff Officer Excv
GM Office Argada Area
Repairing of Vacuum circuit breaker VCB and LVCR assly. and Repairing of tripping system work from operator cabin to field switch and Replacement of ELCB (Earth Leakage Protection Devices) of EKG-5A Shovel sl.no.HMB-582 of Gidi-A Project.
2024_CCL_303669_1
SO(X)(A)/e-NIT/96/23-24/294
Open Tender
Excavation Department Work
Item Rate
7 days
Gidi-A
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,700
27 Mar 2024
4 Mar 2024
14 Mar 2024
4 Mar 2024
13 Mar 2024
4 Mar 2024
4 Mar 2024 - 9 Mar 2024
Amount
Vacuum Bottle for VC
Auxiliary contact for VCKS 7A 29
Repairing and rewinding of 110V DC Coil of Both VCB
Earth leakage protection device (04 Pole, 63A, 300mA)
Repairing of ring for LVCR
Repairing of stud bolt & nut for LVCR
Repairing of carbon brush holders for LVCR
Replacement of carbon Brushes for LVCR
Bushing for LVCR
Insulator for LVCR
Skilled Worker 03 No x 01 Shift x 03 day
Unskilled Worker 03 No x 01 Shift x03
Semiskilled Worker 03 No x 01 Shift x03
Indicating Lamp with Holder
Aux. Contact – 551.029-6x5
Shunt Trip Coil 5 Jik 526.88
HRC Fuse 03 Amp
Moving Contact for 6.6KV 400Amp
Fixed Contact for 400A Rated
Push Button 1No+1NC
Push Button Element KE021-11
Ammeter 60/5
Voltmeter 6.6KV/110-M2100/4200
Single Core Wire 2.5sqmm
Associated Hardware (Nut/Bolt, Washer etc) 447-102
Aux. Transformer Circuit
Under Voltage Relay – OIIT-010411Y3
Diode Based Rectifier Complete (D-816T)
On/Off Mechanism
New fitting of ELCB 04 Pole, 63Amp, 300m
Skilled Worker - 01 No x 03 Days
Semiskilled Worker - 01 No x 03 Days
Unskilled Worker - 01 No x 03 Days
Total impact of GST for the purpose of CTC
BALAJI SALES
M/S HRIDAY & BROTHERS ENGG. WORKS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_314546.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .