Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAccepted-AOC 0 0 KAIMGANJ ROAD KUIYA SANT FARRUKHABAD UTTAR PRADESH 209745 | FARRUKHABAD | UTTAR PRADESH | 209745 | ₹5.3 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹5.3 Cr+₹25,825.93 (0.05%)Rejected-AOC | ₹5.3 Cr+₹25,825.93 (0.05%) | L2 | Rejected-AOC Higher |
| 3 | Not Admitted-Fee/PreQual/Technical AICHOLI PRO BHUWAN CHANDRA JOSHI NEW BHATKOTE PITHORAGARH | ALMORA | UTTARAKHAND | 263601 | - | - | Not Admitted-Fee/PreQual/Technical Others-As Attached |
Tender Value
₹5.3 Cr
EMD Value
₹10.6 L
Closing Date
6 Feb 2024, 6:00 pmClosed
Chief Engineer Kumaun, RWD Bhimtal Nainital
Chief Engineer Kumaun, RWD Bhimtal Nainital
Construction of Multi Level Parking at Gram-Chalori, Block Berinag, District Pithoragarh (Uttarakhand)
2024_RES_67882_1
letter no. 936 dated 19-01-2024
Open Tender
Civil Works
Item Rate
360 days
Berinag
Please refer tender document
5 documents required · 5 mandatory
₹5,900
tender fee Rs. 5000 D.H- 0515008000100
₹10.6 L
Bhimtal
13 Mar 2024
20 Jan 2024
7 Feb 2024
20 Jan 2024
6 Feb 2024
20 Jan 2024
20 Jan 2024 - 6 Feb 2024
24 Jan 2024
Amount
Excavation in soil in Hilly Area by mechanical means Without useinng Dozer including cutting and trimming of side slopes and disposing of excavated earth with a lift upto 1.5 m and a lead upto 20 m as per Technical Specification Clause 1603.1
Excavation in Hilly Areas in Ordinary Rock by mechanical means not requiring blasting (With out Dozer) Excavation in hilly area in ordinary rock not requiring blasting by mechanical means without using Dozer including cutting and trimming of slopes and disposal of cut material with a lift upto 1.5 m and lead upto 20 m as per Clause 1603.2.
Excavation in Hilly Areas in Hard Rock requiring blasting Excavation in hilly areas in hard rock requiring blasting, by mechanical means without using Dozer , lift upto 1.5 m and disposal of excavated rock upto a lead of 20 m as per Clause 1603.2.
Removal of Unsuitable Soil with Disposal upto 1000 m Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C grade M 20 Height upto 5m
PCC M15 Grade leveling course below approach slab complete as per drawing and Technical specification
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers . by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m for all Kinds of soil by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size)
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand). by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in Cement mortar 1:4 (1 cement : 4 coarse sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and laying cement concrete in plain window sills, fillets etc upto floor five level, excluding the cost of centring, shuttering and finishing 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting, ropping etc. and removal of form foundation,footing,bases of columns,etc.for mass concrete
Centring and shuttering including strutting,ropping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers . by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting,ropping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Centring and shuttering including strutting,ropping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases . by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
12 mm cement plaster of mix.1:6 (1 cement : 6 fine sand) by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Honey-comb brick work 10/11.4 cm thick with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand). by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete Fixed to steel windows by welding. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. by the direction in Engineer - in - charge work to be execuated as per specification a rate of above given item
Providing and fixing panelled or panelled and glazed shutters for d and clerestory windows including ISI marked black enamelled M.S necessary screws excluding panelling which will be paid for separa 30 mm thick shutters
S/F of glass paneswith putty & nails whereever necessary Float glass panes of thickness 4mm
windows using galvanised M.S. wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.63 mm.With 12 mm mild steel U beading. as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent or colour or shade with nuts and screws etc. complete.(i)250x16mm
Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete. (i) 300x10mm
Providing and fixing aluminium handles ISI marked anodised(anod less than grade AC10 as perIS:1868)transparent or dyed to req.125 mm
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Twin rubber stopper . as per directions of Engineer-in-charge work to be execuated as per specification a rate of above given item
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including priming coat of whiting to give an even shade. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : Light shade pigment using white cement
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st conforming to IS :15622 of approved make in all colours, shades, exceptquality laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement and matching pigments etc., complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 873 SUB HEAD : 12- ROOFING metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item (75 mm diameter )
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item (110 mm diameter )
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given item Coupler 110 mm
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved each design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4coarse sand) and making good the wall etc. complete. 110 mm. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing to the inlet mouth of rain water pipe each cast iron grating 15 cm diameter and weighing not less than 440 grams. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing ball valve (brass) of approved quality complete. High or low pressure with plastic floats. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given 20 mm nominal bore
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. as per direction of Engineer -in- charge, work to be execuated as per specification a rate of above given (Flexible pipe 32mm dia)
Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall -Iinternal work 15 mm dia. nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work) 20 mm dia. nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture 150 mm diameter as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded ) 150 mm diameter S.W, pipe as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and fixing square-mouth S.W. gully trap grade 'A'' complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size P type With F.P.S. Bricks class designation 75 as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement :3 coarsesand) 12mm thick finished with a floating coat of neat cement complete as per standard design : as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given (With F.P.S. bricks)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank as per direction of Engineer-in-charge, work to be execuated as per specification a rate of above given
Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG), plaster board conforming to IS: 2095: (part 3) 1996 (Board with BIS Certification marks)
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent
PL Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .